Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Recent Advances in the Design of Ionenes: Toward Convergence with High–Performance Polymers

Ionenes, condensation polymers wherein the charge (typically cationic) lies directly within the polymer backbone, have been known for over 85 years. Historically, ionenes have been synthesized from 3° diamines and α,ω-dihaloalkanes, forming chains of ammonium cations tethered by flexible hydrocarbon linkages with “free” halide anions. However, the requisite building blocks of ionenes are by no means limited only to such molecules. In recent years, ionenes with more sophisticated backbone chemistries have been produced, with a trend toward the use of functionalities associated with classical “high-performance” condensation polymers such as polyimides and polyarylamides. The expansion of ionenes is also catalyzed by the rapid growth of research in imidazolium-based ionic liquids (ILs), wherein the combination of ionenes with ILs can yield unexpected behaviors. Furthermore, when considering the largely unexplored experimental space in anionic ionenes, the opportunities for new materials are virtually endless. Furthermore, this review primarily focuses on developments in ionenes published in the scientific literature since 2010, but also includes some older examples that may not have received sufficient attention at the time of their original publication yet can provide some key lessons for the future of ionene design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and characterization of an electromagnetic-resonant cavity microwave plasma reactor for atmospheric pressure carbon dioxide decomposition

Plasma processes are ideally suited for the conversion of renewable electricity into gas-phase reactivity, such as for the decomposition of carbon dioxide (CO 2 ). The design, development, and characterization of a microwave plasma reactor for atmospheric pressure undiluted carbon dioxide decomposition are presented. The reactor operates as an electromagnetic-resonant cavity in which the generated plasma forms a bulb attached to a converging-diverging nozzle and stabilized by streams of tangentially-injected processing gas. Electromagnetic wave confinement, residence time, and critical gas vorticity constitute fundamental reactor sizing and operation parameters. Experimental findings demonstrate that flow rate plays a dual role in plasma stabilization and process performance, whereas deposited power has a minor role in CO 2 decomposition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combinatorial-Hierarchical DNA Library Design Using the TeselaGen DESIGN Module with j5.

Modern DNA assembly techniques are known for their potential to link multiple large DNA fragments together into even larger constructs in single pot reactions that are easier to automate and work more reliably than traditional cloning methods. The simplicity of the chemistry is in contrast to the increased work needed to design optimal reactions that maximize DNA fragment reuse, minimize cost, and organize thousands of potential chemical reactions. Here we examine available DNA assembly methods and describe through example, the construction of a complex but not atypical combinatorial and hierarchical library using protocols that are generated automatically with the assistance of modern synthetic biology software.

Fero, Michael J↗

Design of superionic polymer electrolytes

Despite potential significant advantages of polymer based batteries, the poor ionic conductivity of dry polymer electrolytes at ambient and low temperatures has limited their application. This review describes the approach for improving conductivity by decoupling ionic transport from polymer segmental relaxation. It is emphasized that the decoupling approach is the key for design of superionic polymer electrolytes.

25 ENERGY STORAGE↗

System design of a 1 MW north-facing, solid particle receiver

Falling solid particle receivers (SPR) utilize small particles as a heat collecting medium within a cavity receiver structure. The components required to operate an SPR include the receiver (to heat the particles), bottom hopper (to catch the falling particles), particle lift elevator (to lift particles back to the top of the receiver), top hopper (to store particles before being dropped through the receiver), and ducting. In addition to the required components, there are additional features needed for an experimental system. These features include: a support structure to house all components, calibration panel to measure incident radiation, cooling loops, and sensors (flux gages, thermocouples, pressure gages). Each of these components had to be designed to withstand temperatures ranging from ambient to 700 °C. Thermal stresses from thermal expansion become a key factor in these types of high temperature systems. The SPR will be housing ~3000 kg of solid particles. The final system will be tested at the National Solar Thermal Test Facility in Albuquerque, NM.

14 SOLAR ENERGY↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗