Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Current measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Eddy current characterization of magnetic treatment of materials

Eddy current impedance measuring methods have been applied to study the effect that magnetically treated materials have on service life extension. Eddy current impedance measurements have been performed on Nickel 200 specimens that have been subjected to many mechanical and magnetic engineering processes: annealing, applied strain, magnetic field, shot peening, and magnetic field after peening. Experimental results have demonstrated a functional relationship between coil impedance, resistance and reactance, and specimens subjected to various engineering processes. It has shown that magnetic treatment does induce changes in a material's electromagnetic properties and does exhibit evidence of stress relief. However, further fundamental studies are necessary for a thorough understanding of the exact mechanism of the magnetic-field processing effect on machine tool service life.

Chern, E. James↗

Transparent, High‐Charge Capacity Metal Mesh Electrode for Reversible Metal Electrodeposition Dynamic Windows with Dark‐State Transmission <0.1%

Abstract Dynamic windows allow user control over light and heat flow to save energy and maximize comfort. Reversible metal electrodeposition (RME) dynamic windows can uniquely tint to a color‐neutral privacy state (0.1% visible light transmission). The design parameters of transparent metal mesh counter electrodes for high‐contrast RME dynamic windows: high transparency, charge capacity and surface area with low haze, sheet resistance and cost are discussed, concluding that woven metal meshes meet these design parameters. Electroplated current is measured on an indium tin oxide electrode and two meshes with different wire spacings, showing the meshes’ cylindrical geometry enable them to draw more current per square area. The mesh material composition is analyzed to ensure cycling durability in a CuBi electrolyte by developing a transparent mesh with an inert core (stainless steel, SS), a thin Au coating, and a high charge‐capacity (1.5 C cm −2 ) CuBi outer coating. The study demonstrates that the films maintain a consistent Cu:Bi ratio and optical properties after 250 privacy cycles or 1500 cycles to 10% transmission, showing that the Cu and Bi coating is effective in keeping the films from becoming Cu rich with cycling. Finally, a 100 cm 2 device with excellent uniformity and color neutrality is demonstrated.

Yeang, Andrew L.↗

First Measurement of Charged-Current Muon-Neutrino-Induced 𝐾 + Production on Argon Using the MicroBooNE Detector

The MicroBooNE experiment is an 85 tonne active mass liquid argon time projection chamber neutrino detector exposed to the on-axis Booster Neutrino Beam at Fermilab. One of MicroBooNE’s physics goals is the precise measurement of neutrino interactions on argon in the 1 GeV energy regime. Building on the capabilities of the MicroBooNE detector, this analysis identifies 𝐾 + mesons, a key signature for the study of strange particle production in neutrino interactions. This measurement is furthermore valuable for background estimation for future nucleon decay searches and for improved reconstruction and particle identification capabilities in experiments such as the Deep Underground Neutrino Experiment. In this Letter, we present the first-ever measurement of a flux-integrated cross section for charged-current muon neutrino induced 𝐾 + production on argon nuclei, determined to be 7.93 ± 3.22⁢(stat) ± 2.83⁢(syst)×10 −42 cm 2 /nucleon based on an analysis of 6.88 × 10 20 protons on target. This result was found to be consistent with model predictions from different neutrino event generators within the reported uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New constraint on the Np 237 ( n , γ ) Np 238 integral cross section using the Godiva-IV critical assembly

Accurate knowledge of the 237 Np(n, γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. Perform a model-independent measurement of the 237 Np(n, γ) 238 Np integral cross section using a well characterized fast neutron source and compare the result with previous measurements and current nuclear data evaluations. Provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np(n, γ) 238 Np reaction and an integral cross section of 342(11) mb was measured for the Godiva-IV neutron spectrum. Further, the 238 Np half-life has been measured with a result of 50.31(5) hours. The 237 Np(n, γ) 238 Np integral cross section measured in this work is in agreement with overlapping 1σ error bands to ENDF/B-VIII.0. However, the measured value is 3σ away from the calculated integral cross section using JENDL-5. This measurement offers a reliable benchmark for future 237 Np(n, γ) 238 Np cross section evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The dc arc characteristics in subsonic orifice nozzle flow

The cold air flow field for a 1/27 cm orifice nozzle was determined for subsonic flow velocities. In addition, d.c. arc voltage, current, and diameter measurements were made for a range of velocities and arc gaps. Average voltage gradients increased rapidly as an arc extinguishing velocity was approached. Measured values of current and diameter were used as an input for relaxation solution of an energy balance equation to compute radial temperature profiles. Calculated arc voltage gradients compare favorably with measured average voltage gradients.

Nagamatsu, H. T.↗

Coronal Polarimetry: Determining the Magnetic Origins of Coronal Mass Ejections

Synopsis: The mechanism for the release of stored magnetic energy in solar eruptions remains a major unsolved problem of Heliophysics. Choosing between triggers requires knowledge of pre-eruptive magnetic fields (B). Although linear polarization in visible/infrared (VIR) coronal emission lines reveals intriguing clues about coronal mass ejection (CME) precursor topology, small telescope apertures limit current capability for measuring vector field. Current coronal observations are insufficient to diagnose 3D coronal magnetic fields in CME precursors. Coronal cavities are the ideal candidates for CME precursor studies. BLOS in cavities is a direct measure of stored magnetic free energy, and the presence and location of topological X-points (reconnection locations) and O-points (circulation of B about axis) distinguish predictions of the flux rope-torus-instability and sheared-arcade-breakout CME models. - Finding: Coronal cavities are ubiquitous throughout the solar cycle, erupt as CMEs, and have coronal polarimetric signatures that distinguish between model predictions. - Recommendation: Coronal cavities should be targeted in a comprehensive multiwavelength study of CME precursors & associated eruption-driving mechanisms. Large ground-based VIR telescopes can measure both coronal magnetic field topology and strength through a combination of the saturated Hanle and BLOS -sensitive Zeeman effects. - Finding: The 4m Daniel K. Inouye Solar Telescope (DKIST) and proposed 1.5m Coronal Solar Magnetism Observatory Large Coronagraph (COSMO-LC) make a major leap forward in VIR coronal sensitivity, enabling measurement of vector B. - Recommendation: A dedicated coronal synoptic telescope with a large field-of-view (i.e., COSMO-LC) is needed to identify the dominant CME driving mechanisms, by measuring coronal magnetic fields from precursor state into eruption. In the UV, a new opportunity has arisen to make use of the strong H I Lyman-α coronal line, which obtains a measurement of B that is independent of the Zeeman effect. - Finding: Small-telescope spectropolarimetric capability in the unsaturated Hanle regime provides an independent and complementary coronal magnetic diagnostic to large ground-based telescope measurements. - Recommendation: The proposed 12-cm Coronal Lyman-α Resonance Observatory (CLARO) spectropolarimetric coronagraph demonstrates a path forward for space-based observations of the coronal magnetic field that should be incorporated into future missions away from the Sun-Earth line (e.g., COMPLETE).

magnetic energy↗

Scanning Tunneling Optical Resonance Microscopy

Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically < 10 Hz) that the feedback circuit could respond, then the voltage applied to the piezoelectric tip-height actuator could be measured by use of a lock-in amplifier locked to the modulation (chopping) signal. However, at a high modulation frequency (typically in the kilohertz range or higher), the feedback circuit would be unable to respond. In this case, the photoenhanced portion of the tunneling current could be measured directly. For this purpose, the tunneling current would be passed through a precise resistor and the voltage drop would be measured by use of the lock-in amplifier.

Bailey, Sheila↗

Lidar Monitoring of Clouds and Aerosols at the Facility for Atmospheric Remote Sensing

We report on findings from ongoing polarization lidar research at the University of Utah Facility for Atmospheric Remote Sensing (FARS). This facility was established in 1987, and the current total of lidar and radiometric measurements is approx. 2,900-h. Research at FARS has been applied to the climatological investigation of cirrus cloud properties for basic research and satellite measurement validation (currently in its 13th year), and studies of contrails, mixed phase clouds, and volcanic and Asian dust aerosols. Among the techniques utilized for monitoring cloud and aerosol properties are triple-wave length linear depolarization measurements, and high (1.5-m by 10-Hz) resolution scanning observations. The usefulness of extended time lidar studies for atmospheric and climate research is illustrated.

Sassen, Kenneth↗

Influence of physical and chemical hydrology on bioremediation of a U-contaminated aquifer informed by reactive transport modeling incorporating 238 U/ 235 U ratios

Microbially-catalyzed reductive immobilization of aqueous uranium (U) as a solid phase has been proposed as a U remediation technique. Both laboratory and field experiments have demonstrated that this reduction reaction alters the 238 U/ 235 U ratio, producing a 238 U-enriched U(IV) solid. In contrast, other major U reactive transport processes fractionate these isotopes much less. This suggests the potential to quantify the extent of bioreduction occurring in groundwater containing U using the 238 U/ 235 U ratio, which would substantially improve upon current practices largely relying on U concentration measurements alone. Current reactive transport models for uranium dynamics include only concentration measurements, which are strongly influenced by highly coupled reactive transformation and aqueous transport processes. The complex physical and chemical behavior of U potentially compromises such quantitative analysis of U storage and release. Here we report the first numerical reactive transport model which explicitly incorporates variations in the 238 U/ 235 U ratio of U and demonstrates improved interpretation of the principal chemical reactions and groundwater transport processes affecting the subsurface mobility and distribution of this widespread contaminant. Recent U bioreduction studies performed in a contaminated aquifer in Rifle, Colorado, USA applied Rayleigh distillation models to interpret U stable isotope fractionation observed as a result of acetate amendment. These simplified models were unable to resolve the spatiotemporal pattern of U isotope fractionation recorded in the aqueous solutes. Here, we employ the multi-component, isotope-enabled CrunchTope reactive transport software to interpret these measured U isotope ratios, and demonstrate accurate reproduction of observed trends in both geochemistry and 238 U/ 235 U ratios for two consecutive years of field experiments. Overall, our results indicate that accurately modeling both the U concentration and isotope ratio distributions greatly constrains the parameter space of the model. We find that the transport properties of U in the Rifle aquifer are governed by the presence of low-permeability regions, which the isotopes are uniquely sensitive to. When U reduction is spatially constrained by these low-permeability regions, the shift in the 238 U/ 235 U ratio becomes more muted. Accurate modeling of observed U isotope ratios thus provides a powerful means to better understand bioremediation, and the current study serves to advance the application of this novel method.

238U/235U↗

Measurement of Kinetic-Scale Current Filamentation Dynamics and Associated Magnetic Fields in Interpenetrating Plasmas

Here, we present the first local, quantitative measurements of ion current filamentation and magnetic field amplification in interpenetrating plasmas, characterizing the dynamics of the ion Weibel instability. The interaction of a pair of laser-generated, counterpropagating, collisionless, supersonic plasma flows is probed using optical Thomson scattering (TS). Analysis of the TS ion-feature revealed anticorrelated modulations in the density of the two ion streams at the spatial scale of the ion skin depth c/ω pi = 120 μm, and a correlated modulation in the plasma current. The inferred current profile implies a magnetic field amplitude ~30 ± 6 T , corresponding to ~1% of the flow kinetic energy, indicating that magnetic trapping is the dominant saturation mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gamma Spectrometry Examination of the AGR-3/4 Irradiation

The results from gamma spectrometry examination of the different components from the combined third and fourth U.S. Advanced Gas Reactor (AGR) TRISO-coated particle fuel irradiation tests (AGR-3/4) have been analyzed. This experiment was designed to provide information about in-pile fission product migration. In each of the 12 capsules, a single stack of four compacts with designed-to-fail (DTF) particles surrounded by inner and outer graphite and/or graphitic matrix rings and a graphite sink ring were irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). Gamma spectrometry has been used to evaluate the gamma-emitting fission product inventory of compacts from the irradiation and evaluate the burnup of these compacts based on the activity of the radioactive cesium isotopes (i.e., Cs-134 and Cs-137) in the compacts. Burnup from gamma spectrometry compares well with predicted burnup from simulations. The inner and outer rings were also examined by gamma spectrometry to evaluate the total fission product inventory of the rings, and gamma emission computed tomography (GECT) was used to investigate the spatial distribution of gamma-emitting fission products within the rings. This report focuses on results obtained via the Precision Gamma Scanner (PGS) for the compacts and inner and outer rings. These non-destructive gamma measurements are currently being compared to recent destructive measurements of spatial fission product distributions in the rings and to predictions made via mathematical modeling. A separate report discusses the entire AGR-3/4 fission product mass balance for all irradiation capsule components including the inner and outer rings, graphite sink rings, capsule spacers, capsule foils, through tubes, and felts. This report is similar to the conference proceedings: Harp, J.M., Demkowicz, P.A., and Stempien, J.D., “Initial gamma spectrometry examination of the AGR-3/4 irradiation,” International Topical Meeting High Temperature Reactor Technology (HTR 2016), Las Vegas, NV, USA, November 2016, Paper HTR2016-18593, but it has been updated to reflect all the data that has been collected on AGR-3/4 using PGS. The Appendices contain extensive data from the collected gamma spectra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lidar: A laser technique for remote sensing

Experimental airborne lidar systems proved to be useful for shallow water bathymetric measurements, and detection and identification of oil slicks and algae. Dye fluorescence applications using organic dyes was studied. The possibility of remotely inducing dye flourescence by means of pulsed lasers opens up several hydrospheric applications for measuring water currents, water temperature, and salinity. Aerosol measurements by lidar are also discussed.

Wilkerson, T. D.↗

High temperature properties of GaAlAs/GaAs heteroface solar cells

The properties of p-GaAlAs/p-GaAs/n-GaAs heteroface solar cells were determined in the temperature range from 25 C to 350 C. Illumination air mass zero (AM0) current-voltage measurements show that the short circuit current increases as a function of temperature up to 210 C and then decreases up to 350 C. The open circuit voltage and fill factor decrease linearly with increasing temperature. The spectral response shifts toward higher wavelengths with increasing temperature.

Walker, G. H.↗

Electrodynamics payloads for small rockets

Totally integrated design facilitates electrical cleanliness and light weight, which are necessary in subsonic parachute-borne payloads for electrodynamics investigations. 'Blunt' probes measure ion conductivity, as do Gerdien condensers. Recent finite-element computer analyses combining flow and electrodynamics have resolved problems in determining ion densities and mobilities from Gerdien data. Three-axis electric fields are measured with deployable boom-mounted electrodes from dc through VLF. Splitting the cylindrical payload with an insulator and measuring the current between halves has provided a vertical Maxwell current detector mechanically rigid enough to measure, at ELF, energy related to coupling. A nose tip 'Smith' probe turbulence measurement is usually performed on ascent. Other instrumentation, such as photo-ionization sources and X-ray detectors, can also be included. These electrodynamic measurement payloads are about one meter in length and have a mass of about 9 kg. They can be launched with an Orion-class or smaller vehicle.

Croskey, C. L.↗

Internal Plasma Properties and Enhanced Performance of an 8 cm Ion Thruster Discharge

There is a need for a lightweight, low power ion thruster for space science missions. Such an ion thruster is under development at NASA Glenn Research Center. In an effort to better understand the discharge performance of this thruster. a version of this thruster with an anode containing electrically isolated electrodes at the cusps was fabricated and tested. Discharge characteristics of this ring cusp ion thruster were measured without ion beam extraction. Discharge current was measured at collection electrodes located at the cusps and at the anode body itself. Discharge performance and plasma properties were measured as a function of discharge power, which was varied between 20 and 50 W. It was found that ion production costs decreased by as much as 20 percent when the two most downstream cusp electrodes were allowed to float. Floating the electrodes did not give rise to a significant increase in discharge power even though the plasma density increased markedly. The improved performance is attributed to enhanced electron containment.

Foster, John E.↗

Enhanced Discharge Performance in a Ring Cusp Plasma Source

There is a need for a lightweight, low power ion thruster for space science missions. Such an ion thruster is under development at NASA Glenn Research Center. In an effort to better understand the discharge performance of this thruster, a thruster discharge chamber with an anode containing electrically isolated electrodes at the cusps was fabricated and tested. Characteristics of this ring cusp ion discharge were measured without ion beam extraction. Discharge current was measured at collection electrodes located at the magnetic cusps and at the anode body itself. Discharge performance and plasma properties were measured as a function of power, which was varied between 20 and 50 W. It was found that ion production costs decreased by as much as 20 percent when the two most downstream cusp electrodes were allowed to float. Floating the electrodes did not give rise to a significant increase in discharge power even though the plasma density increased markedly. The improved performance is attributed to enhanced electron containment.

Foster, John E.↗

Plasma Interaction with International Space Station High Voltage Solar Arrays

The International Space Station (ISS) is presently being assembled in low-earth orbit (LEO) operating high voltage solar arrays (-160 V max, -140 V typical with respect to the ambient atmosphere). At the station's present altitude, there exists substantial ambient plasma that can interact with the solar arrays. The biasing of an object to an electric potential immersed in plasma creates a plasma "sheath" or non-equilibrium plasma around the object to mask out the electric fields. A positively biased object can collect electrons from the plasma sheath and the sheath will draw a current from the surrounding plasma. This parasitic current can enter the solar cells and effectively "short out" the potential across the cells, reducing the power that can be generated by the panels. Predictions of collected current based on previous high voltage experiments (SAMPIE (Solar Array Module Plasma Interactions Experiment), PASP+ (Photovoltaic Array Space Power) were on the order of amperes of current. However, present measurements of parasitic current are on the order of several milliamperes, and the current collection mainly occurs during an "eclipse exit" event, i.e., when the space station comes out of darkness. This collection also has a time scale, t approx. 1000 s, that is much slower than any known plasma interaction time scales. The reason for the discrepancy between predictions and present electron collection is not understood and is under investigation by the PCU (Plasma Contactor Unit) "Tiger" team. This paper will examine the potential structure within and around the solar arrays, and the possible causes and reasons for the electron collection of the array.

John W. Heard↗