Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Simple Heat Transfer Model for Film Cooling Applications

This report describes the development of a simple engineering model for film cooling. This model is used to derive a relationship between local wall temperature variations and key cooling performance parameters like local heat transfer coefficients and film effectiveness. This relation and method new and different from previously published models. The scope of this report includes the derivation of regression model equations for a flat plate with and without film cooling. The model equation for a flat plate without film cooling can be used to estimate local heat transfer coefficients using surface temperatures measured from infrared thermography. The model equation for the flat plate with film cooling can be used to estimate film cooling effectiveness, $η_f$, and heat transfer augmentation from the film cooling jet(s).

42 ENGINEERING↗

Psychrometric Bin Analysis for Alternative Cooling Strategies in Data Centers

Data centers are significant energy users and require continuous cooling to maintain high levels of computing performance. The majority of data centers have direct-expansion cooling which typically accounts for approximately 50% of the energy usage of data centers. However, using typical meteorological year 3 (TMY3) weather data and a simple psychometric bin analysis, alternative cooling strategies using a combination of economizer, evaporative, and supplemental DX cooling have been shown to be applicable in all climate zones in the United States. Average data center cooling energy savings across the U.S. was approximately 80%. Analysis of cooling energy savings is presented for various ASHRAE climate zones. The psychometric bin analysis is conducted for the ASHRAE recommended and allowable operating environment zones, as well as, a modified allowable operating environment. Control strategies are discussed. Finally, examples of energy efficient data centers using alternative cooling strategies are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A coherent description of thermal radiative devices and its application on the near-field negative electroluminescent cooling

Using the transmissivity between two thermal reservoirs and the generalized Planck distributions, we describe the devices that use radiative energy transfer between thermal reservoirs in a unified formalism. In this work, four types of devices are distinguished. For power generators that use the temperature difference between reservoirs, photovoltaic (PV) and thermoradiative (TR) devices respectively use the low temperature photovoltaic cell and high-temperature thermoradiative cell to generate electricity. For active cooling, the electroluminescent (EL) cooling devices apply a forward bias voltage on the object we want to cool, whereas the negative EL cooling devices apply a reverse bias voltage to the heat sink. The relationship among these four devices is explicated. The performance of the negative EL cooling is analyzed, both in the Shockley-Queisser (blackbody spectrum and radiative recombination) framework and the near-field enhancement. The “impedance match” condition derived for PV systems is applied to the negative EL devices. One advantageous feature of the negative EL cooling is that it does not apply the voltage to the target object which we want to cool, and the near-field enhancement can apply to various target materials that support the surface resonant modes.

42 ENGINEERING↗

Molecular dynamics simulation of the effect of cooling rate on the structure and properties of lithium disilicate glass

The effects of cooling rate on the structure and properties of lithium disilicate (LS2) glass are investigated using molecular dynamics (MD) computer simulations. The evolution of structural features such as pair distribution function, bond angle distribution, and Li coordination distribution are determined, and correlated with dynamic and static properties to elucidate the effects of cooling rate. The density, elastic moduli, and diffusion coefficient are found to be highly sensitive to cooling rate, whereas the Si pair distribution function and bond angle distribution are weakly affected by the cooling rate. Additionally, the changes of Si-O-Si bond angle and Li coordination number suggest the formation of Li cluster at lower cooling rates. Furthermore, by comparing results from other simulations and reported experiments, we confirm that the increase of cooling rate leads to an increase of conductivity and a decrease of density. Finally, at very high cooling rates, we find that all the atoms in LS2-glass do not relax simultaneously, but do so in two distinct configurations.

36 MATERIALS SCIENCE↗

Study of thermosiphon cooling scheme for the production solenoid of the Mu2e experiment at Fermilab

A thermosiphon cooling scheme is envisioned for the Production Solenoid of the Mu2e experiment at Fermi National Accelerator Laboratory. The thermosiphon cooling is achieved by indirect cooling with helium at 4.7 K. The siphon tubes are welded to the solenoid outer structure. The anticipated heat loads in the solenoid is presented as well as the cooling scheme design. A thermal model using ANSYS to simulate the temperature gradient is presented. The thermal analysis also makes provisions for including the heat load generated in the coils and structures by the secondary radiation simulated using the MARS 15 code. The impact of the heat loads from supports on the solenoid cooling is studied. The thermosiphon cooling scheme is also validated using pertinent correlations to study flow reversals and the cooling regime.

43 PARTICLE ACCELERATORS↗

Flow distribution analysis on the cooling tube network of ITER thermal shield

Thermal shield (TS) is to be installed between the vacuum vessel or the cryostat and the magnets in ITER tokamak to reduce the thermal radiation load to the magnets operating at 4.2K. The TS is cooled by pressurized helium gas at the inlet temperature of 80K. The cooling tube is welded on the TS panel surface and the composed flow network of the TS cooling tubes is complex. The flow rate in each panel should be matched to the thermal design value for effective radiation shielding. This paper presents one dimensional analysis on the flow distribution of cooling tube network for the ITER TS. The hydraulic cooling tube network is modeled by an electrical analogy. Only the cooling tube on the TS surface and its connecting pipe from the manifold are considered in the analysis model. Considering the frictional factor and the local loss in the cooling tube, the hydraulic resistance is expressed as a linear function with respect to mass flow rate. Sub-circuits in the TS are analyzed separately because each circuit is controlled by its own control valve independently. It is found that flow rates in some panels are insufficient compared with the design values. In order to improve the flow distribution, two kinds of design modifications are proposed. The first one is to connect the tubes of the adjacent panels. This will increase the resistance of the tube on the panel where the flow rate is excessive. The other design suggestion is that an orifice is installed at the exit of tube routing where the flow rate is to be reduced. The analysis for the design suggestions shows that the flow mal-distribution is improved significantly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of cooling rate on the properties of high density polyethylene/multi-walled carbon nanotube composites

High density polyethylene (HDPE)/multi-walled carbon nanotube (MWCNT) nanocomposites were prepared by melt mixing using twin-screw extrusion. The extruded pellets were compression moulded at 200°C for 5min followed by cooling at different cooling rates (20°C/min and 300°C/min respectively) to produce sheets for characterization. Scanning electron microscopy (SEM) shows that the MWCNTs are uniformly dispersed in the HDPE. At 4 wt% addition of MWCNTs composite modulus increased by over 110% compared with the unfilled HDPE (regardless of the cooling rate). The yield strength of both unfilled and filled HDPE decreased after rapid cooling by about 10% due to a lower crystallinity and imperfect crystallites. The electrical percolation threshold of composites, irrespective of the cooling rate, is between a MWCNT concentration of 1∼2 wt%. Interestingly, the electrical resistivity of the rapidly cooled composite with 2 wt% MWCNTs is lower than that of the slowly cooled composites with the same MWCNT loading. This may be due to the lower crystallinity and smaller crystallites facilitating the formation of conductive pathways. This result may have significant implications for both process control and the tailoring of electrical conductivity in the manufacture of conductive HDPE/MWCNT nanocomposites.

36 MATERIALS SCIENCE↗

Cooling field tuned magnetic phase transition and exchange bias-like effect in Y{sub 0.9}Pr{sub 0.1}CrO{sub 3}

Cooling magnetic field dependence of magnetic phase transition has been observed in Y{sub 0.9}Pr{sub 0.1}CrO{sub 3}. G{sub z}F{sub x} order (spin structure of PrCrO{sub 3}) is dominant after zero field cooling (ZFC), whereas G{sub x}F{sub z} order (spin structure of YCrO{sub 3}) is dominant after cooling under a field higher than 100 Oe. Positive/negative exchange bias-like effect, with large vertical shift and small horizontal shift, has been observed after FC/ZFC process. The vertical shift can be attributed to the frozen ordered Pr{sup 3+} and Cr{sup 3+} spins in magnetic domains, because of the strong coupling between Pr{sup 3+} and Cr{sup 3+} sublattices; while the horizontal shift is a result of the pinning of spins at the interfaces. The frozen structure is generated by the field used for the measurement of the initial magnetization curve of M(H) for the ZFC cooled sample, while it is generated by the cooling field for the sample cooled under a cooling field higher than 100 Oe.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-molecule electronics: Cooling individual vibrational modes by the tunneling current

Electronic devices composed of single molecules constitute the ultimate limit in the continued downscaling of electronic components. A key challenge for single-molecule electronics is to control the temperature of these junctions. Controlling heating and cooling effects in individual vibrational modes can, in principle, be utilized to increase stability of single-molecule junctions under bias, to pump energy into particular vibrational modes to perform current-induced reactions, or to increase the resolution in inelastic electron tunneling spectroscopy by controlling the life-times of phonons in a molecule by suppressing absorption and external dissipation processes. Under bias the current and the molecule exchange energy, which typically results in heating of the molecule. However, the opposite process is also possible, where energy is extracted from the molecule by the tunneling current. Designing a molecular “heat sink” where a particular vibrational mode funnels heat out of the molecule and into the leads would be very desirable. It is even possible to imagine how the vibrational energy of the other vibrational modes could be funneled into the “cooling mode,” given the right molecular design. Previous efforts to understand heating and cooling mechanisms in single molecule junctions have primarily been concerned with small models, where it is unclear which molecular systems they correspond to. In this paper, our focus is on suppressing heating and obtaining current-induced cooling in certain vibrational modes. Strategies for cooling vibrational modes in single-molecule junctions are presented, together with atomistic calculations based on those strategies. Cooling and reduced heating are observed for two different cooling schemes in calculations of atomistic single-molecule junctions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser cooling of electron – ion plasma in the case of optimal scanning of the laser frequency

Laser cooling of ions of electron – ion plasma is studied under the action of spontaneous radiation pressure forces. It is shown that the use of a constant detuning of the laser frequency from the quantum transition frequency w0 in ions significantly limits the conditions under which the ions are cooled. To extend the range of initial temperatures of possible cooling of ions and to increase the cooling efficiency we suggest scanning the laser frequency detuning so that the cooling rate remained maximal in the process of changing the temperature of ions. In the case of an optimal detuning, we have found an asymptotic expression for the cooling rate and identified intervals of electron concentrations and temperatures, where cooling of ions is possible. (interaction of laser radiation with matter. laser plasma)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A CHANDRA X-RAY ANALYSIS OF ABELL 1664: COOLING, FEEDBACK, AND STAR FORMATION IN THE CENTRAL CLUSTER GALAXY

The brightest cluster galaxy (BCG) in the Abell 1664 cluster is unusually blue and is forming stars at a rate of {approx} 23 M {sub sun} yr{sup -1}. The BCG is located within 5 kpc of the X-ray peak, where the cooling time of 3.5 x 10{sup 8} yr and entropy of 10.4 keV cm{sup 2} are consistent with other star-forming BCGs in cooling flow clusters. The center of A1664 has an elongated, 'barlike' X-ray structure whose mass is comparable to the mass of molecular hydrogen, {approx}10{sup 10} M {sub sun} in the BCG. We show that this gas is unlikely to have been stripped from interloping galaxies. The cooling rate in this region is roughly consistent with the star formation rate, suggesting that the hot gas is condensing onto the BCG. We use the scaling relations of BIrzan et al. to show that the active galactic nucleus (AGN) is underpowered compared to the central X-ray cooling luminosity by roughly a factor of three. We suggest that A1664 is experiencing rapid cooling and star formation during a low state of an AGN feedback cycle that regulates the rates of cooling and star formation. Modeling the emission as a single-temperature plasma, we find that the metallicity peaks 100 kpc from the X-ray center, resulting in a central metallicity dip. However, a multi-temperature cooling flow model improves the fit to the X-ray emission and is able to recover the expected, centrally peaked metallicity profile.

79 ASTRONOMY AND ASTROPHYSICS↗

MEASURING THE EVOLUTIONARY RATE OF COOLING OF ZZ Ceti

We have finally measured the evolutionary rate of cooling of the pulsating hydrogen atmosphere (DA) white dwarf ZZ Ceti (Ross 548), as reflected by the drift rate of the 213.13260694 s period. Using 41 yr of time-series photometry from 1970 November to 2012 January, we determine the rate of change of this period with time to be dP/dt = (5.2 {+-} 1.4) Multiplication-Sign 10{sup -15} s s{sup -1} employing the O - C method and (5.45 {+-} 0.79) Multiplication-Sign 10{sup -15} s s{sup -1} using a direct nonlinear least squares fit to the entire lightcurve. We adopt the dP/dt obtained from the nonlinear least squares program as our final determination, but augment the corresponding uncertainty to a more realistic value, ultimately arriving at the measurement of dP/dt = (5.5 {+-} 1.0) Multiplication-Sign 10{sup -15} s s{sup -1}. After correcting for proper motion, the evolutionary rate of cooling of ZZ Ceti is computed to be (3.3 {+-} 1.1) Multiplication-Sign 10{sup -15} s s{sup -1}. This value is consistent within uncertainties with the measurement of (4.19 {+-} 0.73) Multiplication-Sign 10{sup -15} s s{sup -1} for another similar pulsating DA white dwarf, G 117-B15A. Measuring the cooling rate of ZZ Ceti helps us refine our stellar structure and evolutionary models, as cooling depends mainly on the core composition and stellar mass. Calibrating white dwarf cooling curves with this measurement will reduce the theoretical uncertainties involved in white dwarf cosmochronometry. Should the 213.13 s period be trapped in the hydrogen envelope, then our determination of its drift rate compared to the expected evolutionary rate suggests an additional source of stellar cooling. Attributing the excess cooling to the emission of axions imposes a constraint on the mass of the hypothetical axion particle.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron cooling in a young radio supernova: SN 2012aw

We present the radio observations and modeling of an optically bright Type II-P supernova (SN), SN 2012aw which exploded in the nearby galaxy Messier 95 (M95) at a distance of 10 Mpc. The spectral index values calculated using C, X, and K bands are smaller than the expected values for the optically thin regime. During this time, the optical bolometric light curve stays in the plateau phase. We interpret the low spectral-index values to be a result of electron cooling. On the basis of comparison between the Compton cooling timescale and the synchrotron cooling timescale, we find that the inverse Compton cooling process dominates over the synchrotron cooling process. We therefore model the radio emission as synchrotron emission from a relativistic electron population with a high energy cutoff. The cutoff is determined by comparing the electron cooling timescale, t {sub cool}, and the acceleration timescale, t-tilde {sub acc}. We constrain the mass-loss rate in the wind ( M-dot ∼1.9×10{sup −6} M{sub ⊙} yr{sup −1}) and the equipartition factor between relativistic electrons and the magnetic field ( α-tilde =ϵ{sub e}/ϵ{sub B}∼1.12×10{sup 2}) through our modeling of radio emission. Although the time of explosion is fairly well constrained by optical observations within about two days, we explore the effect of varying the time of explosion to best fit the radio light curves. The best fit is obtained for the explosion date as 2012 March 15.3 UT.

79 ASTRONOMY AND ASTROPHYSICS↗

DUST COOLING IN SUPERNOVA REMNANTS IN THE LARGE MAGELLANIC CLOUD

The infrared-to-X-ray (IRX) flux ratio traces the relative importance of dust cooling to gas cooling in astrophysical plasma such as supernova remnants (SNRs). We derive IRX ratios of SNRs in the LMC using Spitzer and Chandra SNR survey data and compare them with those of Galactic SNRs. IRX ratios of all the SNRs in the sample are found to be moderately greater than unity, indicating that dust grains are a more efficient coolant than gas although gas cooling may not be negligible. The IRX ratios of the LMC SNRs are systematically lower than those of the Galactic SNRs. As both dust cooling and gas cooling pertain to the properties of the interstellar medium, the lower IRX ratios of the LMC SNRs may reflect the characteristics of the LMC, and the lower dust-to-gas ratio (a quarter of the Galactic value) is likely to be the most significant factor. The observed IRX ratios are compared with theoretical predictions that yield IRX ratios an order of magnitude larger. This discrepancy may originate from the dearth of dust in the remnants due to either the local variation of the dust abundance in the preshock medium with respect to the canonical abundance or the dust destruction in the postshock medium. The non-equilibrium ionization cooling of hot gas, in particular for young SNRs, may also cause the discrepancy. Finally, we discuss implications for the dominant cooling mechanism of SNRs in low-metallicity galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

ION-BY-ION COOLING EFFICIENCIES

We present ion-by-ion cooling efficiencies for low-density gas. We use Cloudy (version 10.00) to estimate the cooling efficiencies for each ion of the first 30 elements (H-Zn) individually. We present results for gas temperatures between 10{sup 4} and 10{sup 8} K, assuming low densities and optically thin conditions. When nonequilibrium ionization plays a significant role the ionization states deviate from those that obtain in collisional ionization equilibrium (CIE), and the local cooling efficiency at any given temperature depends on specific nonequilibrium ion fractions. The results presented here allow for an efficient estimate of the total cooling efficiency for any ionic composition. We also list the elemental cooling efficiencies assuming CIE conditions. These can be used to construct CIE cooling efficiencies for non-solar abundance ratios or to estimate the cooling due to elements not included in any nonequilibrium computation. All the computational results are listed in convenient online tables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optomechanical approach to cooling of small polarizable particles in a strongly pumped ring cavity

Cavity cooling of an atom works best on a cyclic optical transition in the strong coupling regime near resonance, where small-cavity photon numbers suffice for trapping and cooling. A straightforward application to the cooling of the translational motion of other polarizable particles without sharply defined two-level transitions (such as molecules) fails as optical pumping transfers the particle into uncoupled states. An alternative operation in the far-off-resonant regime generates only very slow cooling due to the reduced field-particle coupling. We suggest one can overcome this by using a strongly driven ring cavity operated in the sideband cooling regime. The dynamics can be mapped onto the optomechanics setup with a movable mirror and allows one to take advantage of a collectively enhanced field-particle coupling by large photon numbers. A linearized analytical treatment confirmed by full numerical quantum simulations predicts fast cooling despite the off-resonant small single-particle-single-photon coupling. Even ground-state translational cooling (in the external potential) can be obtained by tuning the cavity field close to the Anti-stokes sideband for sufficiently high trapping frequency. Numerical simulations show quantum jumps of the particle between the lowest two trapping levels, which can be directly and continuously monitored via scattered light intensity detection.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effects of Downstream Vortex Generators on Film Cooling a Flat Plate Fed by Crossflow

Counter-rotating vortices, formed by the interaction of film-cooling jets and the hot gas flow, adversely affect the performance of conventional film-cooling designs. Downstream vortex generators have been shown to improve cooling effectiveness by mitigating the effects of the counter-rotating vortices and by deflecting the cooling jet laterally. In this study, computational and experimental methods were used to examine how cylindrical film-cooling holes (D = 3.2 mm, L/D = 6, p/D = 3, α = 30 deg) with and without downstream vortex generators perform when the coolant supply channel is perpendicular to the direction of the hot gas. For this study, the hot gas had a temperature of 650 K and an average Mach number of 0.23. Here, the hot-gas-to-coolant temperature ratio was 1.9, and two blowing ratios (0.75 and 1.0) were studied. Results from the computational fluid dynamics study show how crossflow affects the interaction between the film-cooling jet and hot gas flow with and without downstream vortex generators. The experimental measurements were based on infrared thermography in a conjugate heat transfer environment. Results were obtained for film-cooling performance in terms of overall effectiveness, film effectiveness, and local heat transfer coefficients. The downstream vortex generators can increase the laterally averaged effectiveness by a factor of 1.5 relative to cylindrical holes, but this higher performance is restricted to low crossflow velocities and higher blowing ratios.

17 WIND ENERGY↗

Injection and stability of high-intensity ion beams in synchrotrons with electron cooling

The electron cooling-stacking injection is one of the most widely used injection methods applied in forming high-intensity cooled ion beams in the synchrotrons. The maximum available ion intensity in the synchrotron is determined by the lifetime of ions and the cooling-stacking efficiency. The formation of cooled high-intensity beams is constrained by instability, leading to a strong reduction in the ion lifetime. The results of experimental investigations and simulations of the cooling-stacking injection and stability of high-intensity cooled ion beams in synchrotrons with electron cooling are discussed.

43 PARTICLE ACCELERATORS↗