Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

A Comparison of PV Resource Modeling for Sizing Microgrid Components

Microgrid systems are being deployed with increased frequency to meet critical building loads during unplanned power outages. Determining the appropriate type and size of components that make up a microgrid can greatly affect its ability to meet this need. This paper presents a new tool to appropriately size PV, battery, and generator capacities to meet all site loads, given a resilience goal. It uses a statistical model to simulate microgrid behavior under a large range of solar resource conditions, providing resilience planners with confidence that critical loads will be met even under extreme weather conditions. We compare this model with one that uses typical weather data for sizing microgrids, and quantify the resilience effects of using these different methods. Our method produces more conservative generator capacities and fuel requirements in an outage, predicting up to 30% more fuel required in the most extreme case. Microgrid systems that are designed using more conservative estimates are more likely to continue to serve load during emergency outages under a large range of conditions.

Newman, Sarah F.↗

Comparison of total emitted solar-induced chlorophyll fluorescence (SIF) and top-of-canopy (TOC) SIF in estimating photosynthesis

We report many studies have shown that solar-induced fluorescence (SIF) has a good potential to predict gross primary production (GPP) of vegetation. What we measured by remote sensing or near-surface platforms is top-of-canopy (TOC) SIF (SIF toc ), which is not necessarily equal or proportional to total emitted SIF (SIF tot ) from the entire canopy due to the (re)absorption and scattering effects. However, photosynthesis, the process that plants use to fix carbon from the atmosphere, occurs at the entire vertical canopy. Here, by using the recollision theory, we calculated SIF tot at 760 nm from the measured SIF toc , hyperspectral reflectance (R), canopy interception (i) and leaf albedo (ω l ). Among them, both SIF toc and R can be obtained from concurrent TOC spectral measurements; i and ω l in the near-infrared region can be estimated from the open access datasets with a good accuracy. Our result confirms that the measured SIF toc only accounts for a small fraction of SIF tot : the above-the-canopy sensor can only “see” on average 22.9% of SIF tot at Harvard Forest. SIF tot has the following advantages over SIF toc in estimating GPP: (1) SIF tot improves the diurnal estimate of canopy GPP, especially capable to capture the midday depression of photosynthesis which may cause the large discrepancies between SIF toc and GPP on a diurnal basis, (2) SIF tot produces a stronger correlation with GPP from plants with complex canopy structure or under sky conditions with more diffuse irradiance, and (3) the SIF tot -GPP relationship shows a stronger resilience to environmental stresses. The fluorescence escape ratio (f esc ), the ratio between SIF toc multiplied by π and SIF tot , is mostly determined by the sun-canopy-sensor geometry and leaf inclination distribution. The effect of LAI and the leaf chlorophyll concentration on f esc is marginal at the 760 nm wavelength. Our results suggest that converting SIF toc into SIF tot provides a better tool to understand and estimate GPP.

54 ENVIRONMENTAL SCIENCES↗

A global urban heat island intensity dataset: Generation, comparison, and analysis

The urban heat island (UHI) effect, a phenomenon of local warming over urban areas, is the most well-known impact of urbanization on climate. Globally consistent estimates of the UHI intensity (UHII) are crucial for examining this phenomenon across time and space. However, publicly available UHII datasets are limited and have several constraints: (1) they are for clear-sky surface UHII, not all-sky surface UHII and canopy (air temperature) UHII; (2) the estimation methods often neglect anthropogenic disturbance, introducing uncertainties in the estimated UHII. To address these issues, this study proposes a new dynamic equal-area (DEA) method that can minimize the influence of various confounding factors on UHII estimates through a dynamic cyclic process. Utilizing the DEA method and leveraging various gridded temperature data, we develop a global-scale (>10,000 cities), long-term (over 20 years by month), and multi-faceted (clear-sky surface, all-sky surface, and canopy) UHII dataset. Further, based on these estimates, we provide a comprehensive analysis of the UHII and its trends in global cities. The UHII is found to be greater than zero in >80% of cities, with global annual average magnitudes around 1.0 °C (day) and 0.8 °C (night) for surface UHII, and close to 0.5 °C for canopy UHII. Furthermore, an interannual upward trend in UHII is observed in >60% of cities, with global annual average trends exceeding 0.1 °C/decade (day) and over 0.06 °C/decade (night) for surface UHII, and slightly surpassing 0.03 °C/decade for canopy UHII. Notably, there exists a positive correlation between the magnitude and trend of UHII, suggesting that cities with stronger UHII tend to experience faster growth in UHII. Additionally, discrepancies in UHII are found between different temperature data, stemming not only from distinctions in data types (surface or air temperature) but also from differences in data acquisition times (Terra or Aqua), weather conditions (clear-sky or all-sky), and processing methodologies (with or without gap filling). Overall, our proposed method, dataset, and analysis results have the potential to provide valuable insights for future urban climate studies. The UHII dataset is publicly available at https://doi.org/10.6084/m9.figshare.24821538.

54 ENVIRONMENTAL SCIENCES↗

The impact of sampling scale: A comparison of methods for estimating external contaminant exposure in free-ranging wildlife

The impacts of contaminants on wildlife are dose dependent, and thus being able to track or predict exposure following contamination events is important for monitoring ecosystem health. However, the ability to track exposure in free-ranging wildlife is often severely limited. Consequently, researchers have predominantly relied on simple methods for estimating contaminant exposures in wildlife with little regard for spatial contaminant heterogeneity or an animal’s use of diverse habitats. We evaluated the influence sampling scale (i.e., how finely contaminant distribution and organism’s spatial use of the landscape is mapped) has on (1) realism and (2) conservativeness of exposure estimates. To do this, we monitored the actual exposure of wild boar (Sus scrofa) in Fukushima, Japan to radioactive contamination using GPS27 coupled contaminant monitors placed on individual animals. We compared empirical exposures to estimates generated by combining varying amounts of information about an individual boar’s location and/or movement, with the distribution of contamination on the landscape. Here we found that the most realistic exposure estimates were produced when finer-scale contaminant distribution surveys (e.g., airborne surveys) were combined with more accurate estimates of an individual’s space use (e.g., home ranges or core areas). Importantly, estimates of exposure based on single point surveys at a trap site (a simple method commonly used in the literature), did not correlate with actual exposure rates, suggesting dose-effects studies using this method may result in spurious conclusions. These results suggest that researchers seeking realistic estimates of exposure, such as in dose-effect studies, should ensure they have adequately accounted for fine-scale contaminant distribution patterns and areas of higher use by study organisms. However, conservative estimates of exposure i.e., intentionally over-predicting exposure as is done in initial tiers of ecological risk analyses) were not as scale sensitive and could be achieved with a single known location and coarse contaminant distribution maps.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Effect of seasonal anoxia on geochemical cycling in a stratified pond: Comparison to cooler pond conditions 40 years ago

Seasonal stratification in temperate lakes deeper than a few meters creates favorable conditions for pronounced vertical redox zones, often resulting in anaerobic hypolimnions and significant geochemical changes. Here, this study examined thermocline formation and trace element behavior in a seasonally stratified pond amid rising air temperatures. Over two years, data were collected from Pond B at the US Department of Energy Savannah River Site in Aiken, South Carolina. Pond B, a man-made monomictic reservoir, received cooling water from a nuclear reactor from 1961 to 1964. Strong thermal stratification forms a distinct thermocline in May and progresses downward until November. Compared to the 1980s, this study shows a delayed onset and extended duration of stratification. The prolonged summer stratification reduces deep water oxygen replenishment, extending hypoxic conditions. Trace and major elements sampled in the water column revealed strong correlations between As, Fe, and Mn profiles, with concentrations increasing by 1–2 orders of magnitude in the anaerobic hypolimnion. This period captured the seasonal transition from winter mixing to summer stratification to fall overturn. Under anoxic conditions, Fe(III) reduces to Fe(II) in the sediment, releasing dissolved iron into the water column. The extended anoxic periods likely promoted arsenic release from sediments. Prolonged anoxia may enhance arsenic mobilization and solubility in the lake. This study illustrates how climate-induced changes in seasonal stratification of contaminated waters can convert contaminant sinks into sources, offering insights into the cycling of arsenic and other dissolved ions in stratified lakes and their implications for water quality management.

Anoxic conditions↗

A regional comparison of sub-daily flow variability in regulated and unregulated rivers in the United States

Regulating rivers for hydropower or other purposes can dramatically alter river flow patterns, including creating substantial changes in flow over short, minutes-to-hours-long timespans known as sub-daily flow variability (SDFV). The impacts of flexible hydropower production on flow and aquatic organisms are increasingly documented in research. However, the degree to which flow alteration relates to different hydropower operational modes in distinct geographical regions and seasons is not well understood. This study offers a methodology for regional- and species-appropriate evaluations of potential impacts of flow on fish based on sub-daily flow characteristics of hydropower operational modes. We analyzed 15-min discharge data between 2018 and 2021 from 69 USGS stream gages to compare SDFV in hydropeaking, run-of-river, and unregulated systems in the US Southeast and Pacific Northwest. Regulated systems exhibited significant SDFV downstream from hydropower facilities relative to unregulated systems, but specific impacts differed between regions. Regulated systems in the Southeast were characterized by high flow coefficients of variation and ratios (hydropeaking only) and extended durations of daily upramping flow phases. Regulated systems in the Pacific Northwest were characterized by many short flow phases per day and large portions of the day spent upramping. Pacific Northwest unregulated systems displayed the strongest seasonal flow patterns while Southeastern hydropeaking systems displayed the greatest SDFV. Given that SDFV impacts multiple dimensions of fish ecology, region-specific sub-daily flow signatures have important implications for understanding and mitigating potential community-, species-, and age-specific effects on fish in different parts of the country.

Fish↗

System benefits of industrial battery storage: A comparison of grid and facility control and dispatch

Customer-owned, distributed battery installations are being incentivized by utilities to increase installed battery capacity. In many of these incentive agreements, the battery owner relinquishes battery control to the utility in exchange for incentive money. The industrial sector has lagged in storage installation when compared to the residential and commercial sectors. This study compares the economic advantages to utilities and industrial facilities in different dispatch control situations. The study presents a novel framework for the optimization of multiple systems using load profiles from the industrial, residential, and commercial sectors. Case studies are presented to illustrate different dispatch scenarios. Further, the simulations showed more fiscal benefit for the industrial facilities to dispatch the battery for electrical demand reduction than utility dispatch. In the case studies, facility dispatch control resulted in an increase of facility savings by a factor of about 8.7 when compared to utility dispatch. Battery size plays a significant factor on the impact of the grid’s generating costs, showing that larger batteries can provide significant benefit even if dispatched by the facility. Future policies concerning industrial battery installations should consider overall economic benefits to utility and facility in the form of rate structures and incentive participation based on battery size.

25 ENERGY STORAGE↗

State-by-State comparison of combined heat and power to photovoltaic installations at manufacturing facilities with heat and power loads

Manufacturing facilities with large electricity and steam loads commonly meet those loads with a grid and boiler (GB) system configuration. In this study, two alternatives, a natural gas turbine cycle driven combined heat and power (CHP) system configuration and a grid boiler system augmented with photovoltaics (GB-PV), are investigated sustainable manufacturing in reference to the GB system configuration. For this purpose, their discounted payback period (DPP), carbon dioxide (CO 2 ) and nitrogen oxides (NO x ) emission reductions, and primary fossil energy impacts are calculated. The major contribution of this study is that it directly compares the application of both CHP and PV technologies at an assumed manufacturing facility in all 50 states of the United States. This highlights the location-specific impacts of the facility. The examined manufacturing facility utility requirements are 5 MW of power and over 12,000 kg/h of 250 kPa and 400 K saturated steam. A DPP of less than 25 years, the technology lifetime, is found in 44 states for the CHP system configuration and 6 states for the GB-PV system configuration. GB-PV and CHP cost-effectively reduce CO 2 in 44 and 38 states, respectively. CHP is better for NO x reduction, whereas GB-PV is better for primary fossil energy reduction.

14 SOLAR ENERGY↗

Molten salt electrolysis and room temperature ionic liquid electrochemical processes for refining rare earth metals: Environmental and economic performance comparison

Circularizing end of life products such as electronic waste can open a new source for rare earth elements (REEs) that will decrease the demand pressure on conventional virgin production. The last step to produce REEs consists of a refining process to convert rare earth oxide (REO) to REE metal. One promising technology is processing REO via a room temperature ionic liquid, which is characterized by low energy requirements in contrast to existing REEs extraction processes. In this work, life cycle and techno-economic assessments are performed and compared against molten salt electrolysis. Here, the results show that both processes have advantages and disadvantages in terms of environmental performance, and that they are similarly competitive in terms of economic performance. A breakeven analysis suggests that future research should focus on coupling the production of REOs with the refining processes to attempt to lower REO cost and make them economically feasible in the U.S.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental comparison of pyranometer, reflectometer, and spectrophotometer methods for the measurement of roofing product albedo

Albedo (solar reflectance) can be measured outdoors with a pyranometer or indoors with a hemispherical reflectometer or a spectrophotometer. The current study evaluates these methods and their applicability to roofing materials by measuring and comparing the ASTM E1918 (pyranometer), non-ASTM E1918A (alternative pyranometer), ASTM C1549 (reflectometer), and E903 (spectrophotometer) albedos of 10 roofing products, including three single-ply membranes, one asphalt shingle, three roofing aggregates, and three high-profile tiles. It uses full-size (4 m × 4 m) assemblies in the E1918 and E1918A trials; corrects the E1918 albedos to remove shadow and background errors; and evaluates C1549 and E903 albedos with two different irradiance spectra, one global horizontal and the other beam normal. E1918A albedos matched E1918 corrected (E1918_cor) albedos to within 0.036. Furthermore, agreement between C1549 air mass 1 global horizontal (C1549_G1) albedo and E1918_cor albedo was within 0.015 for membrane and shingle coupons, and within 0.031 for aggregates, though the uncertainty in the latter agreement was up to 0.043. After minor corrections, C1549_G1 albedos of flat or slightly convex tile chips were 0.032–0.052 higher than the E1918_cor albedos of their corresponding high-profile tile assemblies because high-profile surfaces have concavities. Switching to the beam-normal albedo C1549_1.5E increased the C1549 albedos of the 10 tested products by 0.004–0.054, with the largest increases (C1549_1.5E – C1549_G1) accruing to spectrally selective cool colors. Using C1549_1.5E albedo to characterize a chip of a cool-colored tile compounded the error induced by representing a high-profile surface by a flat or slightly convex specimen.

14 SOLAR ENERGY↗

Techno-economic comparison of sCO 2 cycles for particle-based CSP at design-point conditions

In this work, we compare the techno-economic performance of supercritical carbon dioxide power cycles integrated in a particle CSP system. We model four core cycle configurations: simple (with optional bypass), recompression (with optional bypass), partial cooling, and turbine split flow, which each demonstrate different benefits in a CSP system, such as high efficiency, low cost, or large HTF temperature differences. We parametrically sweep cycle design variables for each configuration. The set of power cycle performance results are then combined with a design point particle CSP system model which calculates the system specific cost. The simple cycle and turbine split flow cycles have the best performance in the baseline results, with system specific costs of 5,912 and 5,899 $\$$/kWe respectively. In addition to the baseline set of results, we also vary key parameters and costs in a sensitivity study. The cycle designs with the best system performance limit their efficiency to ~45 %, despite demonstrating higher maximum efficiencies, due to the rapid increase in cost of recuperation as efficiencies rise. The simple cycle has strong performance in the analysis and is on average only 1.4 % worse than the optimal configuration. Lowered turbine inlet temperatures from the sensitivity study improve performance by reducing the PHX and turbine cost. Decreasing the inlet temperature from 700 to 625°C results in an >8 % decrease in system specific cost. Future work should expand sensitivity analyses to colder turbine inlet temperatures and calculate system performance by simulating annual performance with off-design solar and cycle component models.

14 SOLAR ENERGY↗

A comparison of model validation approaches for echo state networks using climate model replicates

As global temperatures continue to rise, climate mitigation strategies such as stratospheric aerosol injections (SAI) are increasingly discussed, but the downstream effects of these strategies are not well understood. As such, there is interest in developing statistical methods to quantify the evolution of climate variable relationships during the time period surrounding an SAI. Feature importance applied to echo state network (ESN) models has been proposed as a way to understand the effects of SAI using a data-driven model. This approach depends on the ESN fitting the data well. If not, the feature importance may place importance on features that are not representative of the underlying relationships. Typically, time series prediction models such as ESNs are assessed using out-of-sample performance metrics that divide the times series into separate training and testing sets. However, this model assessment approach is geared towards forecasting applications and not scenarios such as the motivating SAI example where the objective is using a data driven model to capture variable relationships. Here, in this paper, we demonstrate a novel use of climate model replicates to investigate the applicability of the commonly used repeated hold-out model assessment approach for the SAI application. Simulations of an SAI are generated using a simplified climate model, and different initialization conditions are used to provide independent training and testing sets containing the same SAI event. The climate model replicates enable out-of-sample measures of model performance, which are compared to the single time series hold-out validation approach. For our case study, it is found that the repeated hold-out sample performance is comparable, but conservative, to the replicate out-of-sample performance when the training set contains enough time after the aerosol injection.

54 ENVIRONMENTAL SCIENCES↗