THz time-domain characterization of amplifying quantum-cascade metasurface

An amplifying quantum-cascade (QC) metasurface, the key component of the QC vertical-external-cavity surface-emitting-laser (VECSEL), is studied as a function of injected current density using reflection-mode terahertz time domain spectroscopy. Nearly perfect absorption is measured at zero bias, which is associated with the transition from the weak to strong coupling condition between the metasurface resonance and an intersubband transition within the QC material. An increase in reflectance is observed as the device is biased, both due to reduction in intersubband loss and the presence of intersubband gain. Significant phase modulation associated with the metasurface resonance is observed via electrical control, which may be useful for electrical tuning of QC-VECSEL. These results provide insight into the interaction between the intersubband QC-gain material and the metasurface and modify the design rules for QC-VECSELs for both biased and unbiased regions.

42 ENGINEERING↗

Conflation: a new type of accelerated expansion

In the framework of scalar-tensor theories of gravity, we construct a new kind of cosmological model that conflates inflation and ekpyrosis. During a phase of conflation, the universe undergoes accelerated expansion, but with crucial differences compared to ordinary inflation. In particular, the potential energy is negative, which is of interest for supergravity and string theory where both negative potentials and the required scalar-tensor couplings are rather natural. A distinguishing feature of the model is that, for a large parameter range, it does not significantly amplify adiabatic scalar and tensor fluctuations, and in particular does not lead to eternal inflation and the associated infinities. We also show how density fluctuations in accord with current observations may be generated by adding a second scalar field to the model. Conflation may be viewed as complementary to the recently proposed anamorphic universe of Ijjas and Steinhardt.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of SOL profiles and turbulence in ICRF-heated plasmas in EAST

Scrape-off layer (SOL) profiles and turbulence in ion cyclotron range of frequency (ICRF)-heated plasmas are investigated by the reciprocating probe diagnostic system (FRPs) and gas puff imaging (GPI) diagnostic in EAST. A radio-frequency (RF) sheath potential reaching up to 100 V is identified proximate to the ICRF antennas. Notably, the amplitude of this RF sheath potential escalates in response to rising ICRF power and inversely with plasma density. When a RF sheath is present in the far SOL, a pronounced density ‘shoulder’ forms in front of the ICRF antennas, while the ‘shoulder’ fade away as the antenna and associated RF sheath shift outwards. A strong E r shear is revealed by measurements from both FRPs and GPI. Analysis of the poloidal wave number-frequency spectrum reveals suppression of high-frequency turbulence in the far SOL due to the RF sheath. This effect is manifested in the reduced autocorrelation time τ c and reduced average blob size δ blob of the SOL plasma. Intriguingly, the poloidal propagation direction of the low-frequency turbulence reverses from the electron to the ion diamagnetic drift direction at the RF sheath location. A surge of tungsten impurity is potentially attributed to the heightened interaction between the SOL plasmas and the wall material. Shifting the ICRF antennas outward, to alleviate heat spots, results in the relocation of the RF sheath to the shaded region of the main limiter. This shift amplifies the radial velocity of blobs in the far SOL and concurrently diminishes the SOL density when compared to conditions without ICRF injection. The properties of ion saturation current fluctuations are consistent with the stochastic model predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical and experimental study of the space-charge oscillations in the electron-optical system of a relativistic gyrotron

A theoretical and experimental study of the oscillations of a space-charge cloud in a magnetron-injection gun of a powerful relativistic gyrotron has been performed. The charge storage occurs via electron-beam magnetic compression of the reflection of a part of the electrons having the highest transverse velocities from a magnetic mirror. It has been established that at high values of the compression coefficient the beam loses its stability that finally leads to the appearance of the beam current modulation at the frequency of the longitudinal oscillations of an electron beam in an adiabatic trap. According to the numerical simulations, the energy spread in the formed beam under these conditions reaches 4.6%, which is higher by an order of magnitude than that due to the space-charge effect in the beam transported along the metal tube.

43 PARTICLE ACCELERATORS↗

Noncontacting method for measuring angular deflection

An apparatus is described for indicating the instantaneous angular deflection of an object about a selected axis without mechanical contact with the object. Light from a light source is transmitted through a flat refractor to a converging lens which focuses the light through another flat refractor onto a differential photocell. The first flat refractor is attached to the object such that when the object is deflected about the selected axis the refractor is also deflected about that axis. The two flat refractors are identical and they are placed an equal distance from the converging lens as are the light source and the photocell. The output of the photocell which is a function of image displacement is fed to a high gain amplifier that drives a galvanometer which rotates the second flat refractor. The second refractor is rotated so that the image displacement is very nearly zero making the galvanometer current a measure of the deflection of the object about the selected axis.

Bryant, E. L.↗

Positive water vapour feedback in climate models confirmed by satellite data

It has recently been suggested that GCMs used to evaluate climate change overestimate the greenhouse effect due to increased concentrations of trace gases in the atmosphere. Here, new satellite-generated water vapor data are used to compare summer and winter moisture values in regions of the middle and upper troposphere that have previously been difficult to observe with confidence. It is found that, as the hemispheres warm, increased convection leads to increased water vapor above 500 mbar in approximate quantitative agreement with results from current climate models. The same conclusion is reached by comparing the tropical western and eastern Pacific regions. Thus, water vapor feedback is not overestimated in models and should amplify the climate response to increased trace-gas concentrations.

Rind, D.↗

Reverse Energy Cascade in Turbulent Weakly Ionized Plasmas

For systems far from equilibrium, the neglect of a role for viscous effects in turbulence may be generally inappropriate when the relaxation time for the molecular process approaches the local flow time (Orou et al. (1996)). Furthermore, for stationary collisional plasmas, the conventional Reynolds number is irrelevant under circumstances where the standard features of turbulence in ordinary gases are observed in the plasma (Johnson et al. (1987)). The current theoretical understanding of these turbulent phenomenon is particularly inadequate for turbulence associated with ionizing shock waves; generally speaking, thermodynamic, acoustic and pressure fluctuations are all seen as amplified across the shock wave followed by a dramatic decay (relaminarization) usually attributed to a lack of importance of viscosity in the turbulent regions. This decay would be accelerated when the flow speed is also reduced due to the importance usually given to the conventional Reynolds number (which is directly proportional to velocity) as a quality of turbulence index. However, evidence supporting this consensus is lacking. By contrast, recent evidence of vanishing triple correlations form De Silva et al. (1996) provides strong support for early theoretical speculation of inherently molecular effects in macroscopic turbulence in Tsuge (1974). This specifically suggests that the role of compressive effects ordinarily associated with the shock wave could be significantly muted by the existence of a strongly turbulent local environment. There is also more recent theoretical speculation (Frisch et al. (1984)) of an inherently and previously unsuspected non-dissipative nature to turbulence, with energy conservation being nurtured by reverse energy cascades in the turbulent fluctuation spectra. Furthermore, the role which might be played by fluctuations on quantum mechanical phenomena and variations in molecular parameters is completely unknown, especially of the sort which might be found in optical spectra. A determination of the role which changing turbulent parameters might play on optical signatures behind a reflected shock wave should therefore provide a useful tool for the evolution of theoretical models for turbulence.

Williams, Kyron↗

Off-Design Performance of a Multi-Stage Supersonic Turbine

The drive towards high-work turbines has led to designs which can be compact, transonic, supersonic, counter rotating, or use a dense drive gas. These aggressive designs can lead to strong unsteady secondary flows and flow separation. The amplitude and extent of these unsteady flow phenomena can be amplified at off-design operating conditions. Pre-test off-design predictions have been performed for a new two-stage supersonic turbine design that is currently being tested in air. The simulations were performed using a three-dimensional unsteady Navier-Stokes analysis, and the predicted results have been compared with solutions from a validated meanline analysis.

Dorney, Daniel J.↗

Characterization of Transducers and Resonators under High Drive Levels

In many applications, piezoelectric transducers are driven at AC voltage levels well beyond the level for which the material was nominally characterized. In this paper we describe an experimental setup that allows for the determination of the main transducer or resonator properties under large AC drive. A sinusoidal voltage from a waveform generator is amplified and applied across the transducer/resonator in series with a known high power resistor. The amplitude of applied voltage and the amplitude and the relative phase of the current through the resistor are monitored on a digital scope. The frequency of the applied signal is swept through resonance and the voltage/current signals are recorded. After corrections for the series resistance and parasitic elements the technique allows for the determination of the complex impedance spectra of the sample as a function of frequency. In addition, access to the current signal allows for the direct investigation of non-linear effects through the application of Fourier transform techniques on the current signal. Our results indicate that care is required when interpreting impedance data at high drive level due to the frequency dependence of the dissipated power. Although the transducer/resonator at a single frequency and after many cycles may reach thermal equilibrium, the spectra as a whole cannot be considered an isothermal measurement due to the temperature change with frequency. Methods to correct for this effect will be discussed. Results determined from resonators of both soft and hard PZT and a ultrasonic horn transducer are presented.

transducers↗

Precision bridge circuit using a temperature sensor

A precision bridge measurement circuit connected to a current source providing a linear output voltage versus resistance change of a variable resistance (resistance temperature transducer) including a voltage follower in one branch of the bridge so that the zero setting of the transducer resistance does not depend upon the current source or upon an excitation voltage. The zero setting depends only on the precision and stability of the three resistances. By connecting the output of an instrumentation amplifier to a feedback resistor and then to the output of the voltage follower, minor nonlinearities in the resistance-vs-temperature output of a resistance-temperature transducer, such as a platinum temperature sensor, may be corrected. Sensors which have nonlinearity opposite in polarity to platinum, such as nickel-iron sensors, may be linearized by inserting an inverting amplifier into the feedback loop.

Mount, Bruce E.↗

Systematic Destruction of Electronic Parts for Aid in Electronic Failure Analysis

NASA analyzes electrical, electronic, and electromechanical (EEE) parts used in space vehicles to understand failure modes of these components. Operational amplifiers and transistors are two examples of EEE parts critical to NASA missions that can fail due to electrical overstress (EOS). EOS is the result of voltage or current over time conditions that exceeds a component s specification limit. The objective of this study was to provide known voltage pulses over well-defined time intervals to determine the type and extent of damage imparted to the device. The amount of current was not controlled but measured so that pulse energy was determined. The damage was ascertained electrically using curve trace plots and optically using various metallographic techniques. The resulting data can be used to build a database of physical evidence to compare to damaged components removed from flight avionics. The comparison will provide the avionics failure analyst necessary information about voltage and times that caused flight or test failures when no other electrical data is available.

Decker, S. E.↗

Imaging by time-tagging photons with the multi-anode microchannel array detector system

The capability and initial use of the Multi-Anode Microchannel Array (MAMA) detector in the time-tag mode is reported. The detector hardware currently in use consists of a visible-light detector tube with a semitransparent photocathode proximity-focused to a high-gain curved-channel microchannel plate MCP. The photoevents are detected by a (256 x 1024)-pixel coincidence-anode array with pixel dimensions of 25 x 25 microns connected to charge-sensitive amplifiers and event-detection circuitry. In the time-lag mode, the detector delivers the pixel address and the time of arrival for each detected photon to an accuracy of 10 microns. The maximum count rate is limited by the speed of data-acquisition hardware. The MAMA detector in the time-lag mode is currently being evaluated in programs of astrometry and speckle imaging.

Timothy, J. G.↗

Diode Laser Velocity Measurements by Modulated Filtered Rayleigh Scattering

The ability of solid-state lasers to be tuned in operating frequency at MHz rates by input current modulation, while maintaining a relatively narrow line-width, has made them useful for spectroscopic measurements. Their other advantages include low cost, reliability, durability, compact size, and modest power requirements, making them a good choice for a laser source in micro-gravity experiments in drop-towers and in flight. For their size, they are also very bright. In a filtered Rayleigh scattering (FRS) experiment, a diode laser can be used to scan across an atomic or molecular absorption line, generating large changes in transmission at the resonances for very small changes in frequency. The hyperfine structure components of atomic lines of alkali metal vapors are closely spaced and very strong, which makes such atomic filters excellent candidates for sensitive Doppler shift detection and therefore for high-resolution velocimetry. In the work we describe here we use a Rubidium vapor filter, and work with the strong D(sub 2) transitions at 780 nm that are conveniently accessed by near infrared diode lasers. The low power output of infrared laser diodes is their primary drawback relative to other laser systems commonly used for velocimetry. However, the capability to modulate the laser frequency rapidly and continuously helps mitigate this. Using modulation spectroscopy and a heterodyne detection scheme with a lock-in amplifier, one can extract sub-microvolt signals occurring at a specific frequency from a background that is orders of magnitude stronger. The diode laser modulation is simply achieved by adding a small current modulation to the laser bias current. It may also be swept repetitively in wavelength using an additional lower frequency current ramp.

Mach, J. J.↗

High-Efficiency Microwave Power Amplifier

A high-efficiency power amplifier that operates in the S band (frequencies of the order of a few gigahertz) utilizes transistors operating under class-D bias and excitation conditions. Class-D operation has been utilized at lower frequencies, but, until now, has not been exploited in the S band. Nominally, in class D operation, a transistor is switched rapidly between "on" and "off" states so that at any given instant, it sustains either high current or high voltage, but not both at the same time. In the ideal case of zero "on" resistance, infinite "off" resistance, zero inductance and capacitance, and perfect switching, the output signal would be a perfect square wave. Relative to the traditional classes A, B, and C of amplifier operation, class D offers the potential to achieve greater power efficiency. In addition, relative to class-A amplifiers, class-D amplifiers are less likely to go into oscillation. In order to design this amplifier, it was necessary to derive mathematical models of microwave power transistors for incorporation into a larger mathematical model for computational simulation of the operation of a class-D microwave amplifier. The design incorporates state-of-the-art switching techniques applicable only in the microwave frequency range. Another major novel feature is a transmission-line power splitter/combiner designed with the help of phasing techniques to enable an approximation of a square-wave signal (which is inherently a wideband signal) to propagate through what would, if designed in a more traditional manner, behave as a more severely band-limited device (see figure). The amplifier includes an input, a driver, and a final stage. Each stage contains a pair of GaAs-based field-effect transistors biased in class D. The input signal can range from -10 to +10 dBm into a 50-ohm load. The table summarizes the performances of the three stages

Sims, Williams H.↗

Toward Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ): Initial fabrication and characterization

Purpose We present the first prototype Scintillator High‐Gain Avalanche Rushing Photoconductor Active Matrix Flat Panel Imager ( SHARP ‐ AMFPI ). This detector includes a layer of avalanche amorphous Selenium (a‐Se) ( HARP ) as the photoconductor in an indirect detector to amplify the signal and reduce the effects of electronic noise to obtain quantum noise‐limited images for low‐dose applications. It is the first time avalanche a‐Se has been used in a solid‐state imaging device and poses as a possible solution to eliminate the effects of electronic noise, which is crucial for low‐dose imaging performance of AMFPI . Methods We successfully deposited a solid‐state HARP structure onto a 24 × 30 cm 2 array of thin‐film transistors ( TFT array) with a pixel pitch of 85 μm. The HARP layer consists of 16 μm of a‐Se with a hole‐blocking and electron‐blocking layer to prevent charge injection from the high‐voltage bias and pixel electrodes, respectively. An electric field ( E S e ) up to 105 V μm −1 was applied across the a‐Se layer without breakdown. A 150 μm thick‐structured CsI:Tl scintillator was used to form SHARP ‐ AMFPI . The x‐ray imaging performance is characterized using a 30 kV p Mo/Mo beam. We evaluate the spatial resolution, noise power, and detective quantum efficiency at zero frequency of the system with and without avalanche gain. The results are analyzed using cascaded linear system model ( CLSM ). Results An avalanche gain of 76 ± 5 was measured at E S e = 105 V μm −1 . We demonstrate that avalanche gain can amplify the signal to overcome electronic noise. As avalanche gain is increased, image quality improves for a constant (0.76 mR ) exposure until electronic noise is overcome. Our system is currently limited by poor optical transparency of our high‐voltage electrode and long integrating time which results in dark current noise. These two effects cause high‐spatial frequency noise to dominate imaging performance. Conclusions We demonstrate the feasibility of a solid‐state HARP x‐ray imager and have fabricated the largest active area HARP sensor to date. Procedures to reduce secondary quantum and dark noise are outlined. Future work will improve optical coupling and charge transport which will allow for frequency DQE and temporal metrics to be obtained.

Scheuermann, James R.↗

Boreal–Arctic wetland methane emissions modulated by warming and vegetation activity

Abstract Wetland methane (CH 4 ) emissions over the Boreal–Arctic region are vulnerable to climate change and linked to climate feedbacks, yet understanding of their long-term dynamics remains uncertain. Here, we upscaled and analysed two decades (2002–2021) of Boreal–Arctic wetland CH 4 emissions, representing an unprecedented compilation of eddy covariance and chamber observations. We found a robust increasing trend of CH 4 emissions (+8.9%) with strong inter-annual variability. The majority of emission increases occurred in early summer (June and July) and were mainly driven by warming (52.3%) and ecosystem productivity (40.7%). Moreover, a 2 °C temperature anomaly in 2016 led to the highest recorded annual CH 4 emissions (22.3 Tg CH 4 yr −1 ) over this region, driven primarily by high emissions over Western Siberian lowlands. However, current-generation models from the Global Carbon Project failed to capture the emission magnitude and trend, and may bias the estimates in future wetland CH 4 emission driven by amplified Boreal–Arctic warming and greening.

54 ENVIRONMENTAL SCIENCES↗

Free-electron laser driven by the LBNL laser-plasma accelerator

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by a high-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source ({approx}10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (> or approx.10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10{sup 13} photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

43 PARTICLE ACCELERATORS↗

Coherent Stacking Scheme for Inverse-Compton Scattering at MHz Repetition Rates

An experiment to produce 1-MeV gamma rays via Compton back-scattering of infrared photons on 250-MeV electron bunches is currently in preparation at the Fermilab Accelerator Science & Technology (FAST) facility. To increase the gamma-ray flux the energy of the infrared laser pulses are planned to be amplified within the interaction region using a resonant cavity. This passive amplifier composed of a Fabry-Perot cavity will allow the laser pulse bunches to coherently and constructively stack. Our estimates, based on theoretical models, show that the laser pulse energy can be increased from approximately 1-2 mJ at the exit of the last active amplifier to 5 -10 mJ at the interaction point when the laser repetition rate is set at the nominal value of 3 MHz. This paper details the cavity design option(s) and associated wave-optic simulations.