Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAPACITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Decreased Soil Organic Matter in a Long-Term Soil Warming Experiment Lowers Soil Water Holding Capacity and Affects Soil Thermal and Hydrological Buffering

Long-term soil warming can decrease soil organic matter (SOM), resulting in self-reinforcing feedback to the global climate system. We investigated additional consequences of SOM reduction for soil water holding capacity (WHC) and soil thermal and hydrological buffering. At a long-term soil warming experiment in a temperate forest in the northeastern United States, we suspended the warming treatment for 104 days during the summer of 2017. The formerly heated plot remained warmer (+0.39 °C) and drier (-0.024 cm 3 H 2 O cm -3 soil) than the control plot throughout the suspension. We measured decreased SOM content (-0.184 g SOM g -1 for O horizon soil, -0.010 g SOM g -1 for A horizon soil) and WHC (-0.82 g H 2 O g -1 for O horizon soil, -0.18 g H2O g -1 for A horizon soil) in the formerly heated plot relative to the control plot. Reduced SOM content accounted for 62% of the WHC reduction in the O horizon and 22% in the A horizon. We investigated differences in SOM composition as a possible explanation for the remaining reductions with Fourier transform infrared (FTIR) spectra. We found FTIR spectra that correlated more strongly with WHC than SOM, but those particular spectra did not differ between the heated and control plots, suggesting that SOM composition affects WHC but does not explain treatment differences in this study. We conclude that SOM reductions due to soil warming can reduce WHC and hydrological and thermal buffering, further warming soil and decreasing SOM. This feedback may operate in parallel, and perhaps synergistically, with carbon cycle feedbacks to climate change.

54 ENVIRONMENTAL SCIENCES↗

Dual Impacts of Space Heating Electrification and Climate Change Increase Uncertainties in Peak Load Behavior and Grid Capacity Requirements in Texas

Around 60% of households in Texas currently rely on electricity for space heating. As decarbonization efforts increase, non‐electrified households could adopt electric heat pumps, significantly increasing peak (highest) electricity demand in winter. Simultaneously, anthropogenic climate change is expected to increase temperatures, the potential for summer heat waves, and associated electricity demand for cooling. Uncertainty regarding the timing and magnitude of these concurrent changes raises questions about how they will jointly affect the seasonality of peak demand, firm capacity requirements, and grid reliability. This study investigates the net effects of residential space heating electrification and climate change on long‐term demand patterns and load shedding potential, using climate change projections, a predictive load model, and a direct current optimal power flow (DCOPF) model of the Texas grid. Results show that full electrification of residential space heating by replacing existing fossil fuel use with higher efficiency heat pumps could significantly improve reliability under hotter futures. Less efficient heat pumps may result in more severe winter peaking events and increased reliability risks. As heating electrification intensifies, system planners will need to balance the potential for greater resource adequacy risk caused by shifts in seasonal peaking behavior alongside the benefits (improved efficiency and reductions in emissions).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of COVID-19 staged alert systems to ensure healthcare capacity with minimal closures

Community mitigation strategies to combat COVID-19, ranging from healthy hygiene to shelter-in-place orders, exact substantial socioeconomic costs. Judicious implementation and relaxation of restrictions amplify their public health benefits while reducing costs. We derive optimal strategies for toggling between mitigation stages using daily COVID-19 hospital admissions. With public compliance, the policy triggers ensure adequate intensive care unit capacity with high probability while minimizing the duration of strict mitigation measures. In comparison, we show that other sensible COVID-19 staging policies, including France’s ICU-based thresholds and a widely adopted indicator for reopening schools and businesses, require overly restrictive measures or trigger strict stages too late to avert catastrophic surges. As proof-of-concept, we describe the optimization and maintenance of the staged alert system that has guided COVID-19 policy in a large US city (Austin, Texas) since May 2020. As cities worldwide face future pandemic waves, our findings provide a robust strategy for tracking COVID-19 hospital admissions as an early indicator of hospital surges and enacting staged measures to ensure integrity of the health system, safety of the health workforce, and public confidence.

60 APPLIED LIFE SCIENCES↗

Realizing high-capacity all-solid-state lithium-sulfur batteries using a low-density inorganic solid-state electrolyte

Abstract Lithium-sulfur all-solid-state batteries using inorganic solid-state electrolytes are considered promising electrochemical energy storage technologies. However, developing positive electrodes with high sulfur content, adequate sulfur utilization, and high mass loading is challenging. Here, to address these concerns, we propose using a liquid-phase-synthesized Li 3 PS 4 -2LiBH 4 glass-ceramic solid electrolyte with a low density (1.491 g cm −3 ), small primary particle size (~500 nm) and bulk ionic conductivity of 6.0 mS cm −1 at 25 °C for fabricating lithium-sulfur all-solid-state batteries. When tested in a Swagelok cell configuration with a Li-In negative electrode and a 60 wt% S positive electrode applying an average stack pressure of ~55 MPa, the all-solid-state battery delivered a high discharge capacity of about 1144.6 mAh g −1 at 167.5 mA g −1 and 60 °C. We further demonstrate that the use of the low-density solid electrolyte increases the electrolyte volume ratio in the cathode, reduces inactive bulky sulfur, and improves the content uniformity of the sulfur-based positive electrode, thus providing sufficient ion conduction pathways for battery performance improvement.

25 ENERGY STORAGE↗

Five-volt-class high-capacity all-solid-state lithium batteries

Advances in battery technology have been impeded by the voltage constraints of electrolytes. Here, in this study, we present a high-energy all-solid-state battery design featuring >5 V operation and an ultrahigh areal capacity of 35.3 mAh cm −2 ; these attributes were enabled by a highly conductive and ultrahigh-voltage stable fluoride solid electrolyte, LiCl–4Li 2 TiF 6 (1.7 × 10 −5 S cm −1 at 30 °C). LiCl–4Li 2 TiF 6 shields high-voltage spinel oxide cathodes, achieving 106 mAh g −1 at 2C with 75.2% retention over 500 cycles for LiNi 0.5 Mn 1.5 O 4 , sharply contrasting with the conventional LiNbO 3 counterpart, which decomposes and fails to prevent detrimental interfacial degradation. The efficacy of LiCl–4Li 2 TiF 6 is validated across various systems, including LiCoMnO 4 , LiFe 0.5 Mn 1.5 O 4 and pouch-type LiNi 0.5 Mn 1.5 O 4 ||Li (or Ag–C) all-solid-state batteries, and further demonstrated by operability down to 2.3 V with 258 mAh g −1 and ultrathick 1.8-mm electrodes. This shielding layer with >5 V stability introduces a transformative design paradigm by revisiting the previously forbidden high-voltage cathodes.

36 MATERIALS SCIENCE↗

A large molecular cluster with high proton release capacity

We present a single molecular polyoxometalate cluster (K-41[(P2W12Nb6O62)(6){Mn-3(OH)(3)(H2O)(6)}(4){Mn3Na(H2O)(16)}]center dot 26H(2)O) with controllable release of a large number of protons (similar to 40 per molecule) in its aqueous solution upon addition of a base. The deprotonation/protonation process is reversible with the clusters remaining intact. This molecule can also absorb up to 11 protons per cluster when an acid, HCl, was added to its original aqueous solution. To the best of our knowledge, such large proton absorption/release capacity along with excellent stability is unprecedented.

Zhang, Dongdi↗

Lithium vanadium oxide (Li 1.1 V 3 O 8 ) thick porous electrodes with high rate capacity: utilization and evolution upon extended cycling elucidated via operando energy dispersive X-ray diffraction and continuum simulation

The phase distribution of lithiated LVO in thick (~500 μm) porous electrodes (TPEs) designed to facilitate both ion and electron transport was determined using synchrotron-based operando energy dispersive X-ray diffraction (EDXRD). Probing 3 positions in the TPE while cycling at a 1C rate revealed a homogeneous phase transition across the thickness of the electrode at the 1st and 95th cycles. Additionally, continuum modelling indicated uniform lithiation across the TPE in agreement with the EDXRD results and ascribed decreasing accessible active material to be the cause of loss in delivered capacity between the 1st and 95th cycles. The model was supported by the observation of significant particle fracture by SEM consistent with loss of electrical contact. Overall, the combination of operando EDXRD, continuum modeling, and ex situ measurements enabled a deeper understanding of lithium vanadium oxide transport properties under high rate extended cycling within a thick highly porous electrode architecture.

25 ENERGY STORAGE↗

An Na/TM-site Mg substituted P2-Na 2/3 [Fe 1/3 Mg 1/12 Mn 7/12 ]O 2 cathode with extremely high capacity for sodium-ion batteries

The anionic redox reaction (ARR) has become a hot topic in battery research due to its ability to provide high energy density. Nevertheless, there are still many issues in Na-based layered oxides with the ARR, such as large voltage hysteresis, lattice oxygen loss, irreversible structural changes, and cation migration in the TM layer, resulting in structural collapse and poor electrochemical performance. Herein, a series of Na 2/3 [Fe 1/3 Mg x Mn 2/3–x ]O 2 cathodes are synthesized using a traditional solid-state reaction method. The effectiveness of Mg substitution amounts and site occupancy in regulating the reversibility of the ARR has been explored using various experimental techniques. Surprisingly, the well-designed Na/TM-site Mg substituted P2-Na 2/3 [Fe 1/3 Mg 1/12 Mn 7/12 ]O 2 exhibits an extremely high initial reversible capacity of ~253.21 mA h g –1 , equivalent to ~0.94 e – transfer, which is contributed by both cationic and anionic redox reactions as confirmed by hard X-ray absorption spectroscopy (hXAS) and soft X-ray absorption spectroscopy (sXAS) analyses. In addition, the improved cycling and high-rate performance of the P2-Na 2/3 [Fe 1/3 Mg 1/12 Mn 7/12 ]O 2 are achieved by a well-maintained crystal structure and the highly reversible anionic redox reaction of O 2– /O n– . Finally, these in-depth studies provide crucial knowledge for the development and understanding of cathode materials with a highly reversible ARR for low-cost and high-energy sodium-ion batteries.

36 MATERIALS SCIENCE↗

K–Co–Mo–S x chalcogel: high-capacity removal of Pb 2+ and Ag + and the underlying mechanisms

Chalcogenide-based aerogels, known as chalcogels, represent a novel class of nanoparticle-based porous amorphous materials characterized by high surface polarizability and Lewis base properties, exhibiting promising applications in clean energy and separation science. This work presents a K–Co–Mo–S x (KCMS) chalcogel as a highly efficient sorbent for heavy metal ions and details its sorption mechanisms. Its incoherent structure comprises Mo 2 V (S 2 ) 6 and Mo 3 IV S(S 6 ) 2 anion-like clusters with four- and six-coordinated Co–S polyhedra, forming a Co–Mo–S covalent network that hosts K + ions through electrostatic attraction. The interactions of KCMS with heavy metal ions, particularly Pb 2+ and Ag + , reveal that KCMS is exceptionally effective in removing these ions from ppm concentrations down to trace levels (≤5 ppb). KCMS rapidly removes Ag + (≈81.7%) and Pb 2+ (≈99.5%) within five minutes, achieving >99.9% removal within an hour, with a distribution constant K d ≥10 8 mL g -1 . KCMS exhibits an impressive removal capacity of 1378 mg g -1 for Ag + and 1146 mg g -1 for Pb 2+ , establishing it as one of the most effective materials known to date for heavy metal removal. This material is also effective for the removal of Ag + and Pb 2+ along with Hg 2+ , Ni 2+ , Cu 2+ , and Cd 2+ from various water sources even in the presence of highly concentrated and chemically diverse cations, anions, and organic species. Analysis of the post-interacted KCMS by synchrotron X-ray pair distribution function (PDF), X-ray photoelectron spectroscopy (XPS) and energy dispersive X-ray spectroscopy (EDS) revealed that the sorption of Pb 2+ , Ag + , and Hg 2+ mainly occurs by the exchange of K + and Co 2+ . Despite being amorphous, this material exhibits unprecedented ion-exchange mechanisms both for the ionically and covalently bound K + and Co 2+ , respectively. In conclusion, this discovery advances our knowledge of amorphous gels and guides material synthesis principles for the highly selective and efficient removal of heavy metal ions from water.

54 ENVIRONMENTAL SCIENCES↗

Capacity-weighted figures-of-merit for battery transport metrics

Fast-charging materials are necessary for a battery-centric future. Ionic and electronic transport crucially determine performance where their capacity-weighted figures-of-merit account for performance across all states-of-charge.

Sturgill, CJ [Department of Chemistry and Biochemi↗

Tuning CO 2 uptake capacity in covalent organic frameworks via metal doping

Covalent organic framework (COF) structures have been synthesized and doped with Cu 2+ , Mn 2+ , and Zn 2+ . Incorporation of a phenol moiety increases metal doping capacity by 2–5% by mass, and results in increased CO 2 adsorption by as much as 40%, compared to undoped structures. Interestingly, gas uptake is improved even though the incorporation of cations in the pore lowers the overall surface area of the structures.

Root, Harrison Duane [Sandia National Laboratories↗

Improving photovoltaic hosting capacity of distribution networks with coordinated inverter control: A case study of the EPRI J1 feeder

Abstract Adding photovoltaic (PV) systems in distribution networks, while desirable for reducing the carbon footprint, can lead to voltage violations under high solar‐low load conditions. The inability of traditional volt‐VAr control in eliminating all the violations is also well‐known. This article presents a novel coordinated inverter control methodology that leverages system‐wide situational awareness to significantly improve hosting capacity (HC). The methodology employs a real‐time voltage‐reactive power (VQ) sensitivity matrix in an iterative linear optimizer to calculate the minimum reactive power intervention from PV inverters needed for mitigating over‐voltage without resorting to active power curtailing or requiring step voltage regulator setting changes. The algorithm is validated using the EPRI J1 feeder under an extensive set of realistic use cases and is shown to provide 3x improvement in HC under all scenarios.

Dalal, Dhaval [School of Electrical, Computer, and↗

Capacity Design Method for Integrated Convective/Radiant Terminals to Guarantee Overall and Local Environment

To achieve energy efficiency in the operation of heating devices and ensure thermal comfort in indoor environments, the integrated convective/radiant terminals have become an important development direction for heating systems. This study selected a 14 m 2 bedroom hot summer and cold winter region in China as a case study. Computational Fluid Dynamics (CFD) methodology was used to investigate the design of integrated convective/radiant terminals to ensure thermal comfort for both the entire room and partial space. The results indicate that focusing on partial space during the steady-state stage can achieve energy savings of 31.1% compared to guaranteeing the entire room. Additionally, during the start-up stage, there is a significant reduction of convective unit capacity by 17.6% when the start-up time is 15 minutes. These findings provide data support for the design and engineering applications of products of integrated convective/radiant terminals. Besides, the excess convection ratios for the entire room and partial space are specified as 0.69 to 0.80 and 0.73 to 0.83, respectively.

Chi, Junjie↗

Wide bandwidth frequency-domain thermoreflectance: Volumetric heat capacity, anisotropic thermal conductivity, and thickness measurements

A frequency-domain thermoreflectance (FDTR) system with a frequency range of 1 Hz to 75 MHz is presented. The wide bandwidth of pump modulation frequency enables enhanced simultaneous thermophysical property characterization of bulk and thin-film materials. The wide bandwidth FDTR system is demonstrated with simultaneous measurements of in-plane and cross-plane thermal conductivities of sapphire and muscovite mica, thickness and thermal conductivity of gold/titanium thin films, and isotropic thermal conductivity and volumetric heat capacity of lithium niobate and silicon. Thermophysical properties measured with FDTR are compared to literature values or independent measurements for verification. Finally, at low frequencies, a negligible error was achieved in the numerical integration of the heat diffusion equation with a Gauss–Legendre quadrature method solved with 400 integration points and an upper integration limit of 16weff, where weff is the effective pump–probe 1/e2 radius.

Ziade, Elbara (ORCID:0000000249020497)↗