Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bypass Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer

This device is a biasable, submillimeter-wave, balanced mixer fabricated using JPL s monolithic membrane process a simplified version of planar membrane technology. The primary target application is instrumentation used for analysis of atmospheric constituents, pressure, temperature, winds, and other physical and chemical properties of the atmospheres of planets and comets. Other applications include high-sensitivity gas detection and analysis. This innovation uses a balanced configuration of two diodes allowing the radio frequency (RF) signal and local oscillator (LO) inputs to be separated. This removes the need for external diplexers that are inherently narrowband, bulky, and require mechanical tuning to change frequency. Additionally, this mixer uses DC bias-ability to improve its performance and versatility. In order to solve problems relating to circuit size, the GaAs membrane process was created. As much of the circuitry as possible is fabricated on-chip, making the circuit monolithic. The remainder of the circuitry is precision-machined into a waveguide block that holds the GaAs circuit. The most critical alignments are performed using micron-scale semiconductor technology, enabling wide bandwidth and high operating frequencies. The balanced mixer gets superior performance with less than 2 mW of LO power. This can be provided by a simple two-stage multiplier chain following an amplifier at around 90 GHz. Further, the diodes are arranged so that they can be biased. Biasing pushes the diodes closer to their switching voltage, so that less LO power is required to switch the diodes on and off. In the photo, the diodes are at the right end of the circuit. The LO comes from the waveguide at the right into a reduced-height section containing the diodes. Because the diodes are in series to the LO signal, they are both turned on and off simultaneously once per LO cycle. Conversely, the RF signal is picked up from the RF waveguide by the probe at the left, and flows rightward to the diodes. Because the RF is in a quasi- TEM (suspended, microstrip-like) mode, it impinges on the diodes in an anti-parallel mode that does not couple to the waveguide mode. This isolates the LO and RF signals. This operation is similar to a cross-bar mixer used at low frequencies, except the RF signal enters through the back-short end of the waveguide rather than through the side. The RF probe also conveys the down-converted intermediate frequency (IF) signal out to an off-chip circuit board through a simple LC low-pass filter to the left as indicated. The bias is brought to the diodes through a bypass capacitor at the top.

Siegel, Peter↗

Modeling supercritical CO2 injection induced rupture of a minor fault embedded in a poroelastic layered reservoir-caprock system

CO2 injection for geologic carbon sequestration involves hydromechanical processes that lead to changes in fluid pressure and stresses that can activate existing faults. This paper presents a new method and workflow of modeling fault activation considering more complex three-dimensional geometry of natural faults using the TOUGH-FLAC multiphase fluid flow and geomechanical simulator. In this method and workflow, FLAC3D mechanical interfaces and TOUGH3 finite volume elements are discretized using computer aided design and gridding software along with a tailored mesh translation routine. The method and workflow are demonstrated with a model of a curved minor fault embedded in a poro-elastic layered reservoir-caprock system. The model is used for a comprehensive sensitivity analysis of fault responses to fault length, injection mass rate, injection schedule, well-fault distance, and well locations versus fault location. Four metrics (CO2 plume, shear state of fault, pressure and stress path at fault monitoring points) are selected to assess CO2 migration, pressure change, and the reactivation of faults. The results reveal that CO2 can bypass around the tip of the minor impermeable fault, building up pressure and poro-elastic stress on both sides that tends to impede fault rupture. Our study shows the benefit of carefully designing the injection to achieve the targeted final storage volume, starting at a relatively low rate for considerable time, and then ramping up the injection rate to the full rate of injection. The initial low injection has two distinct benefits: (1) it allows for the formation of an extensive CO2 plume with a much higher mobility through a low viscosity that will result in a lower pressure for a given injection rate, and (2) it allows for gradual build-up of horizontal poro-elastic stress within the reservoir that will tend to impede activation of steeply dipping faults. The injection scenario starting at a low injection rate, denoted here as conservative injection, can significantly reduce the risk of fault activation as high fluid mobility and reservoir strengthening poro-elastic stress has been established long before reaching the peak injection rates. Moreover, simultaneous injection in two injection wells on both sides of fault can provide further reservoir strengthening through poro-elastic stress buildup acting on a fault under normal faulting stress regime. The findings presented in the paper can provide practical and effective guidance on long-term, safe, and reliable geological CO2 storage.

Cao, Meng↗

Demonstration of Wavelet Techniques in the Spectral Analysis of Bypass Transition Data

A number of wavelet-based techniques for the analysis of experimental data are developed and illustrated. A multiscale analysis based on the Mexican hat wavelet is demonstrated as a tool for acquiring physical and quantitative information not obtainable by standard signal analysis methods. Experimental data for the analysis came from simultaneous hot-wire velocity traces in a bypass transition of the boundary layer on a heated flat plate. A pair of traces (two components of velocity) at one location was excerpted. A number of ensemble and conditional statistics related to dominant time scales for energy and momentum transport were calculated. The analysis revealed a lack of energy-dominant time scales inside turbulent spots but identified transport-dominant scales inside spots that account for the largest part of the Reynolds stress. Momentum transport was much more intermittent than were energetic fluctuations. This work is the first step in a continuing study of the spatial evolution of these scale-related statistics, the goal being to apply the multiscale analysis results to improve the modeling of transitional and turbulent industrial flows.

Lewalle, Jacques↗

Developmental design, fabrication, and test of acoustic suppressors for fans of high bypass turbofan engines

An analysis procedure was developed for design of acoustically treated nacelles for high bypass turbofan engines. The plan was applied to the conceptual design of a nacelle for the quiet engine typical of a 707/DC-8 airplane installation. The resultant design was modified to a test nacelle design for the NASA Lewis quiet fan. The acoustic design goal was a 10 db reduction in effective perceived fan noise levels during takoff and approach. Detailed nacelle designs were subsequently developed for both the quiet engine and the quiet fan. The acoustic design goal for each nacelle was 15 db reductions in perceived fan noise levels from the inlet and fan duct. Acoustically treated nacelles were fabricated for the quiet engine and quiet fan for testing. Performance of selected inlet and fan duct lining configurations was experimentally evaluated in a flow duct. Results of the tests show that the linings perform as designed.

Tucker, R. H.↗

Diagnosing Noise Features Of Internally Mixed, External Plug Exhaust Systems

In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.

Noise prediction, supersonic, jet noise↗

Diagnosing Noise Features Of Internally Mixed, External Plug Exhaust Systems

In internally mixed exhaust systems, a lobed or forced mixer is employed to mix the core and bypass streams before they exit the common nozzle. For moderate bypass-ratio engines this marginally improves thrust, and provides a significant acoustic benefit. Indeed, it has been thought that a fully mixed jet creates the lowest noise you can get from a two-stream engine. Typically, the forced mixer system produces a bit more noise than a fully mixed equivalent jet, noise that has been called “excess noise”. In recent testing, this excess noise seemed to be amplified when an external plug was employed in the exhaust system to reduce boattail drag. Identifying the mechanism of this excess noise and mitigating it is key to creating commercial supersonic vehicles that are acoustically acceptable around airports. This paper adds to that investigation, analyzing results from recent tests where far-field acoustic data were acquired on two sets of flows with matched fully mixed flow conditions. One set of flows had a heated core stream, making it a dual-stream jet. The other set had both streams heated to the same temperature, making a single-stream jet that matched the fully mixed temperature and velocity of the dual-stream jet. These flows were tested in two lobed-mixer exhaust systems with internal and external plugs. Analysis of flow and noise data from the nozzles with combinations of single- and dual-stream flows, and with and without flight streams, gives insight into how and why the noise of the dual-stream and single-stream jet differ. One additive source, present in nozzles both with and without external plugs, comes from inside the nozzle, likely the internal shear layer coming off the lobed mixer. This noise source is not impacted by a change in flight stream and has a distinctive spectral directivity that is amplified by the presence of the external plug. Finding the exact source mechanism of this new source will be key to making the internally mixed exhaust systems reach their lowest possible sound level.

Noise prediction↗

Progression of creep deformation from grain boundaries to grain interior in Al-Cu-Mn-Zr alloys

Creep mechanisms are studied in θ'-Al 2 Cu-strengthened Al-Cu-Mn-Zr alloys at 300 and 350°C for (i) ACMZ, a base alloy without further alloying elements and (ii) RR350, a commercial alloy with additions of Ni and Co forming distinct grain-boundary precipitates. At high stresses, creep is dominated by dislocations bypassing θ' precipitates within grains via the Orowan mechanism, as evidenced by (i) very high stress exponent (n~20-25) and (ii) α-Al and θ' lattice strains (measured via in-situ neutron diffraction) evolving during creep in a manner consistent with load transfer from the plastically-deforming α-Al matrix to elastically-deforming θ' precipitates. At intermediate stresses, both alloys exhibit a n~3 regime, where α-Al and θ' lattice strains scale near-linearly with applied stress while remaining largely unaffected by strain accumulation, indicating that Orowan looping or dislocation pile-up around θ' is now inactive within the grains. Rather, dislocation motion occurs solely in θ'-precipitate-free zones (θ'-PFZ) where high dislocation densities are observed via TEM after creep deformation. Plastic flow at θ'-PFZ and/or localized pipe diffusion are expected to enable grain-boundary sliding (GBS), which is proposed as the rate-limiting mechanism in the n~3 regime. Ni/Co-rich precipitates at RR350 grain-boundaries, with negligible θ'-PFZ around them, share load (as determined via neutron diffraction) with the α-Al matrix more effectively than θ-Al 2 Cu precipitates at ACMZ grain-boundaries, with wide surrounding θ'-PFZ. So, high creep resistance in the n~3 GBS regime of RR350 is enabled by coarsening-resistant grain-boundary precipitates, forming without concomitant development of weak θ'-PFZ, which effectively share load with the grains.

36 MATERIALS SCIENCE↗

Feedback Control of a Morphing Chevron for Takeoff and Cruise Noise Reduction

Noise from commercial high-bypass ratio turbofan engines is generated by turbulent mixing of the hot jet exhaust, fan stream, and ambient air. Serrated aerodynamic devices, known as chevrons, along the trailing edges of a jet engine primary and secondary exhaust nozzle have been shown to reduce jet noise at takeoff and shock-cell noise at cruise conditions. Their optimum shape is a finely tuned compromise between noise-benefit and thrust-loss. The design of a full scale Variable Geometry Chevron (VGC) fan-nozzle incorporating Shape Memory Alloy (SMA) actuators is described in a companion paper. This paper describes the development and testing of a proportional-integral control system that regulates the heating of the SMA actuators to control the VGC s tip immersion. The VGC and control system were tested under representative flow conditions in Boeing s Nozzle Test Facility (NTF). Results from the NTF test which demonstrate controllable immersion of the VGC are described. The paper also describes the correlation between strains and temperatures on the chevron with a photogrammetric measurement of the chevron's tip immersion.

Cabell, Randolph H.↗

Conceptual Design of Propulsors for the SUSAN Electrofan Transport Aircraft

Conceptual designs of the propulsor modules for the SUSAN electro-fan aircraft are sought after. Shaft power requirement is reduced by using boundary layer ingesting propulsion technology. There are several obstacles to designing feasible BLI propulsion systems such as inlet distortion, flow blockage from ingesting low-momentum flow, strong coupling between airframe and propulsion systems. Thus, the high fidelity CFD tool is indispensable to assess the performance of the propulsion systems and evaluate the inlet profiles during the design process. Consequently, the CFD data is used to update the inputs for the NPSS model from the initial stage of the system design. Hence, the inlet sizing, fan design, and estimation of the power saving are carried out. Various installation concepts of the mail-slot nacelle, such as under-/over-wing and trailing edge configurations, are investigated for the wing-mounted turbo-electric distributed propulsor module, and their power-saving is evaluated. As for the tail-mounted turbofan engine, the fan diameter and inlet captured area is determined based on the CFD profiles. An appropriate area ratio of the bypass and core ducts is derived from meeting the target bypass ratio from the system design. The baseline fan stage is analyzed by full annulus URANS CFD to assess the efficiency penalty due to the ingested pressure and swirl distortions.

SUSAN Electro-Fan Aircraft↗

Conceptual Design of Propulsors for the SUSAN Electrofan Transport Aircrafts

Conceptual designs of the propulsor modules for the SUSAN electro-fan aircraft are sought after. Shaft power requirement is reduced by using boundary layer ingesting propulsion technology. There are several obstacles to designing feasible BLI propulsion systems such as inlet distortion, flow blockage from ingesting low-momentum flow, strong coupling between airframe and propulsion systems. Thus, the high fidelity CFD tool is indispensable to assess the performance of the propulsion systems and evaluate the inlet profiles during the design process. Consequently, the CFD data is used to update the inputs for the NPSS model from the initial stage of the system design. Hence, the inlet sizing, fan design, and estimation of the power saving are carried out. Various installation concepts of the mail-slot nacelle, such as under-/over-wing and trailing edge configurations, are investigated for the wing-mounted turbo-electric distributed propulsor module, and their power-saving is evaluated. As for the tail-mounted turbofan engine, the fan diameter and inlet captured area is determined based on the CFD profiles. An appropriate area ratio of the bypass and core ducts is derived from meeting the target bypass ratio from the system design. The baseline fan stage is analyzed by full annulus URANS CFD to assess the efficiency penalty due to the ingested pressure and swirl distortions.

Electric Aircraft↗

Double-Balloon-Assisted n-Butyl-2-Cyanoacrylate Embolization of Intrahepatic Arterioportal Shunt Prior to Chemoembolization of Hepatocellular Carcinoma

A case of multiple hepatocellular carcinomas with a severe intrahepatic arterioportal shunt that was successfully embolized with n-butyl-2-cyanoacrylate with coaxial double-balloon occlusion prior to transcatheter arterial chemoembolization is presented. A proximal balloon positioned at the proper hepatic artery was used for flow control, and a coaxial microballoon, positioned in the closest of three arterial feeding branches to the arterioportal shunt, was used to control the delivery of n-butyl-2-cyanoacrylate. This coaxial double-balloon technique can prevent proximal embolization and distal migration of n-butyl-2-cyanoacrylate and enable precise control of the distribution of n-butyl-2-cyanoacrylate. It could also be applicable to n-butyl-2-cyanoacrylate embolization for other than intrahepatic arterioportal shunt.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Turbulence Measurements and Computations for the Predication of Broadband Noise in High Bypass Ratio Fans

Work was performed under this grant with a view to providing the experimental and computational results needed to improve the prediction of broadband stator noise in large bypass ratio aircraft engines. The central hypothesis of our study was that a large fraction of this noise was generated by the fan tip leakage vortices. More specifically, that these vortices are a significant component of the fan wake turbulence and they contain turbulent eddies of a type that can produce significant broadband noise. To test this hypothesis we originally proposed experimental work and computations with the following objectives: (1) to build a large scale two-dimensional cascade with a tip gap and a stationary endwall that, as far as possible, simulates the fan tip geometry, (2) to build a moving endwall for use with the large scale cascade, (3) to measure, in detail, the turbulence structure and spectrum generated by the blade wake and tip leakage vortex, for both endwall configurations, (4) to use the CFD to compute the flow and turbulence distributions for both the experimental configurations and the ADP fan, (5) to provide the experimental and CFD results for the cascades and the physical understanding gained from their study as a basis for improving the broadband noise prediction method. In large part these objectives have been achieved. The most important achievements and findings of our experimental and computational efforts are summarized below. The bibliography at the end of this report includes a list of all publications produced to date under this project. Note that this list is necessarily incomplete the task of publication (particularly in journal papers) continues.

Devenport, William J.↗

Validation Ice Crystal Icing Engine Test in the Propulsion Systems Laboratory at NASA Glenn Research Center

The Propulsion Systems Laboratory (PSL) is an existing altitude simulation jet engine test facility located at NASA Glenn Research Center in Clevleand, OH. It was modified in 2012 with the integration of an ice crystal cloud generation system. This paper documents the inaugural ice crystal cloud test in PSLthe first ever full scale, high altitude ice crystal cloud turbofan engine test to be conducted in a ground based facility. The test article was a Lycoming ALF502-R5 high bypass turbofan engine, serial number LF01. The objectives of the test were to validate the PSL ice crystal cloud calibration and engine testing methodologies by demonstrating the capability to calibrate and duplicate known flight test events that occurred on the same LF01 engine and to generate engine data to support fundamental and computational research to investigate and better understand the physics of ice crystal icing in a turbofan engine environment while duplicating known revenue service events and conducting test points while varying facility and engine parameters. During PSL calibration testing it was discovered than heated probes installed through tunnel sidewalls experienced ice buildup aft of their location due to ice crystals impinging upon them, melting and running back. Filtered city water was used in the cloud generation nozzle system to provide ice crystal nucleation sites. This resulted in mineralization forming on flow path hardware that led to a chronic degradation of performance during the month long test. Lacking internal flow path cameras, the response of thermocouples along the flow path was interpreted as ice building up. Using this interpretation, a strong correlation between total water content (TWC) and a weaker correlation between median volumetric diameter (MVD) of the ice crystal cloud and the rate of ice buildup along the instrumented flow path was identified. For this test article the engine anti-ice system was required to be turned on before ice crystal icing would occur. The ice crystal icing event, an uncommanded reduction in thrust, was able to be turned on and off by manipulating cloud TWC. A flight test point where no ice crystal icing event occurred was also duplicated in PSL. Physics based computational tools were successfully used to predict tunnel settings to induce ice buildup along the low pressure compression system flow path for several test points at incrementally lower altitudes, demonstrating that development of ice crystal icing scaling laws is potentially feasible. Analysis of PSL test data showed that uncommanded reduction in thrust occurs during ice crystal cloud on operation prior to fan speed reduction. This supports previous findings that the reduction of thrust for this test article is due to ice buildup leading to a restricted airflow from either physical or aerodynamic blockage in the engine core flow path.

Ice Crystal Icing↗

Validation Ice Crystal Icing Engine Test in the Propulsion Systems Laboratory at NASA Glenn Research Center

The Propulsion Systems Laboratory (PSL) is an existing altitude simulation jet engine test facility located at NASA Glenn Research Center in Cleveland, OH. It was modified in 2012 with the integration of an ice crystal cloud generation system. This paper documents the inaugural ice crystal cloud test in PSL--the first ever full scale, high altitude ice crystal cloud turbofan engine test to be conducted in a ground based facility. The test article was a Lycoming ALF502-R5 high bypass turbofan engine, serial number LF01. The objectives of the test were to validate the PSL ice crystal cloud calibration and engine testing methodologies by demonstrating the capability to calibrate and duplicate known flight test events that occurred on the same LF01 engine and to generate engine data to support fundamental and computational research to investigate and better understand the physics of ice crystal icing in a turbofan engine environment while duplicating known revenue service events and conducting test points while varying facility and engine parameters. During PSL calibration testing it was discovered than heated probes installed through tunnel sidewalls experienced ice buildup aft of their location due to ice crystals impinging upon them, melting and running back. Filtered city water was used in the cloud generation nozzle system to provide ice crystal nucleation sites. This resulted in mineralization forming on flow path hardware that led to a chronic degradation of performance during the month long test. Lacking internal flow path cameras, the response of thermocouples along the flow path was interpreted as ice building up. Using this interpretation, a strong correlation between total water content (TWC) and a weaker correlation between median volumetric diameter (MVD) of the ice crystal cloud and the rate of ice buildup along the instrumented flow path was identified. For this test article the engine anti-ice system was required to be turned on before ice crystal icing would occur. The ice crystal icing event, an uncommanded reduction in thrust, was able to be turned on and off by manipulating cloud TWC. A flight test point where no ice crystal icing event occurred was also duplicated in PSL. Physics based computational tools were successfully used to predict tunnel settings to induce ice buildup along the low pressure compression system flow path for several test points at incrementally lower altitudes, demonstrating that development of ice crystal icing scaling laws is potentially feasible. Analysis of PSL test data showed that uncommanded reduction in thrust occurs during ice crystal cloud on operation prior to fan speed reduction. This supports previous findings that the reduction of thrust for this test article is due to ice buildup leading to a restricted airflow from either physical or aerodynamic blockage in the engine core flow path.

Turbofan Engine↗

Development of the ANL Plant Dynamics Code and Control Strategies for the Supercritical Carbon Dioxide Brayton Cycle and Code Validation with Data from the Sandia Small-Scale Supercritical Carbon Dioxide Brayton Cycle Test Loop

Significant progress has been made in the ongoing development of the Argonne National Laboratory (ANL) Plant Dynamics Code (PDC), the ongoing investigation and development of control strategies, and the analysis of system transient behavior for supercritical carbon dioxide (S-CO 2 ) Brayton cycles. Several code modifications have been introduced during FY2011 to extend the range of applicability of the PDC and to improve its calculational stability and speed. A new and innovative approach was developed to couple the Plant Dynamics Code for S-CO 2 cycle calculations with SAS4A/SASSYS-1 Liquid Metal Reactor Code System calculations for the transient system level behavior on the reactor side of a Sodium-Cooled Fast Reactor (SFR) or Lead-Cooled Fast Reactor (LFR). The new code system allows use of the full capabilities of both codes such that whole-plant transients can now be simulated without additional user interaction. Several other code modifications, including the introduction of compressor surge control, a new approach for determining the solution time step for efficient computational speed, an updated treatment of S-CO 2 cycle flow mergers and splits, a modified enthalpy equation to improve the treatment of negative flow, and a revised solution of the reactor heat exchanger (RHX) equations coupling the S-CO 2 cycle to the reactor, were introduced to the PDC in FY2011. All of these modifications have improved the code computational stability and computational speed, while not significantly affecting the results of transient calculations. The improved PDC was used to continue the investigation of S-CO 2 cycle control and transient behavior. The coupled PDC-SAS4A/SASSYS-1 code capability was used to study the dynamic characteristics of a S-CO 2 cycle coupled to a SFR plant. Cycle control was investigated in terms of the ability of the cycle to respond to a linear reduction in the electrical grid demand from 100% to 0% at a rate of 5%/minute. It was determined that utilization of turbine throttling control below 50% load improves the cycle efficiency significantly. Consequently, the cycle control strategy has been updated to include turbine throttle valve control. The new control strategy still relies on inventory control in the 50%-90% load range and turbine bypass for fine and fast generator output adjustments, but it now also includes turbine throttling control in the 0%-50% load range. In an attempt to investigate the feasibility of using the S-CO 2 cycle for normal decay heat removal from the reactor, the cycle control study was extended beyond the investigation of normal load following. It was shown that such operation is possible with the extension of the inventory and the turbine throttling controls. However, the cycle operation in this range is calculated to be so inefficient that energy would need to be supplied from the electrical grid assuming that the generator could be capable of being operated in a motoring mode with an input electrical energy from the grid having a magnitude of about 20% of the nominal plant output electrical power level in order to maintain circulation of the CO 2 in the cycle. The work on investigation of cycle operation at low power level will be continued in the future. In addition to the cycle control study, the coupled PDC-SAS4A/SASSYS-1 code system was also used to simulate thermal transients in the sodium-to-CO 2 heat exchanger. Several possible conditions with the potential to introduce significant changes to the heat exchanger temperatures were identified and simulated. The conditions range from reactor scram and primary sodium pump failure or intermediate sodium pump failure on the reactor side to pipe breaks and valve malfunctions on the S-CO 2 side. It was found that the maximum possible rate of the heat exchanger wall temperature change for the particular heat exchanger design assumed is limited to ±7 C/s for less than 10 seconds. Modeling in the Plant Dynamics Code has been compared with available data from the Sandia National Laboratories (SNL) small-scale S-CO 2 Brayton cycle demonstration that is being assembled in a phased approach currently at Barber-Nichols Inc. and at SNL in the future. The available data was obtained with an earlier configuration of the S-CO 2 loop involving only a single-turbo-alternator-compressor (TAC) instead of two TACs, a single low temperature recuperator (LTR) instead of both a LTR and a high temperature recuperator (HTR), and fewer than the later to be installed full set of electric heaters. Due to the absence of the full heating capability as well as the lack of a high temperature recuperator providing additional recuperation, the temperature conditions obtained with the loop are too low for the loop conditions to be prototypical of the S-CO 2 cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of Potential Leakage Pathways and Mineralization within Caprocks for Geologic Storage of CO 2

We used a multifaceted approach to investigate the nature of caprocks above, and the interface between, reservoir-quality rocks that might serve as targets for carbon storage. Fieldwork in southeastern Utah examined the regional- to m-scale nature of faults and fractures across the sedimentiological interfaces. We also used microscopic analyses and mechanical modeling to examine the question as to how the contacts between units interact, and how fractures may allow fluids to move from reservoirs to caprock. Regional-­scale analyses using ASTER data enabled us to identify location of alteration, which led to site-­specific studies of deformation and fluid flow. In the Jurassic Carmel Formation, a seal for the Navajo Sandstone, we evaluated mesoscale variability in fracture density and morphology and variability in elastic moduli in the Jurassic Carmel Formation, a proposed seal to the underlying Navajo Sandstone for CO 2 geosequestration. By combining mechano-stratigraphic outcrop observations with elastic moduli derived from wireline log data, we characterize the variability in fracture pattern and morphology with the observed variability in rock strength within this heterolithic top seal. Outcrop inventories of discontinuities show fracture densities decrease as bed thickness increases and fracture propagation morphology across lithologic interfaces vary with changing interface type. Dynamic elastic moduli, calculated from wireline log data, show that Young’s modulus varies by up to 40 GPa across depositional interfaces, and by an average of 3 GPa across the reservoir/seal interface. We expect that the mesoscale changes in rock strength will affect the distributions of localized stress and thereby influence fracture propagation and fluid flow behavior within the seal. These data provide a means to closely tie outcrop observations to those derived from subsurface data and estimates of subsurface rock strength. We also studied damage zones associated normal faults in the Permian Cedar Mesa Sandstone, southeastern Utah. These faults are characterized by a single slip surfaces and damage zones containing deformation bands, veins, and joints. Field observations include crosscutting relationships, permeability increase, rock strength decrease, and ultraviolet light induced mineral fluorescence within the damage zone. These field observations combined with the interpreted paragenetic sequence from petrographic analysis, suggests a deformation history of reactivation and several mineralization events in an otherwise low-permeability fault. All deformation bands and veins fluoresce under ultraviolet light, suggesting connectivity and a shared mineralization history. Pre-­existing deformation features act as loci for younger deformation and mineralization events, this fault and its damage zone illustrate the importance of the fault damage zone to subsurface fluid flow. We model a simplified stress history in order to understand the importance of rock properties and magnitude of tectonic stress on the deformation features within the damage zone. The moderate confining pressures, possible variations in pore pressure, and the porous, fine-­grained nature of the Cedar Mesa Sandstone results in a fault damage zone characterized by enhanced permeability, subsurface fluid flow, and mineralization. Structural setting greatly influences fracture spacing and orientation. Three structural settings were examined and include fault proximity, a fold limb of constant dip, and a setting proximal to the syncline hinge. Fracture spacing and dominant fracture orientation vary at each setting and distinctions between regional and local paleo-stress directions can be made. Joints on the fold limb strike normal to the fold axis/bedding and are interpreted to be sub-parallel to the maximum regional paleo-stress direction as there is no fold related strain. Joints proximal to faults and the syncline hinge may have formed under local stress conditions associated with folding and faulting, and in some cases, are perpendicular to the maximum regional paleo-stress direction. Macroscale analyses of the Iron Wash fault, which cuts most of the stratigraphy of the reservoir- seal analogs, reveals that seal bypass occurs along faults with mixed lithologic composition. While portions of the fault may be effective seals, when modeled as a whole the fault zone cannot support a high CO 2 column. We adapted oil-field methods to calculate column heights and sealing capacities. Examination of the burial and tectonic histories of the rocks, coupled with field- and micro-­scale studies, allow us to examine the potential for seal failure using basic rock mechanics failure analyses. These studies reveal that the sealing lithologies experienced multiple episodes of deformation that resulted in numerous fractures and small faults. In a stress state based on burial history and overburden loads, we show that most of the seals could fail with normal to slightly excess pore pressures.

58 GEOSCIENCES↗

Brigham City Hydro Generation Project

Brigham City owns and operates its own municipal power system which currently includes several hydroelectric facilities. This project was to update the efficiency and capacity of current hydro production due to increased water flow demands that could pass through existing generation facilities. During 2006-2012, this project completed efficiency evaluation as it related to its main objective by completing a feasibility study, undergoing necessary City Council approvals and required federal environmental reviews. As a result of Phase 1 of the project, a feasibility study was conducted to determine feasibility of hydro and solar portions of the original proposal. The results indicated that the existing Hydro plant which was constructed in the 1960’s was running at approximately 77% efficiency or less. Brigham City proposes that the efficiency calculations be refined to determine the economic feasibility of improving or replacing the existing equipment with new high efficiency equipment design specifically for the site. Brigham City completed the Feasibility Assessment of this project, and determined that the Upper Hydro that supplies the main culinary water to the city was feasible to continue with. Brigham City Council provided their approval of feasibility assessment’s results. The Upper Hydro Project include removal of the existing powerhouse equipment and controls and demolition of a section of concrete encased penstock, replacement of penstock just upstream of the turbine inlet, turbine bypass, turbine shut-off and bypass valves, turbine and generator package, control equipment, assembly, start-up, commissioning, Supervisory Control And Data Acquisition (SCADA), and the replacement of a section of conductors to the step-up transformer. Brigham City increased the existing 575 KW turbine and generator with an 825 KW turbine and generator. Following the results of the feasibility assessment Brigham City pursued required environmental reviews with the DOE and the U.S. Fish and Wildlife Services (USFWS) concurring with the National Environmental Policy Act of 1969 (NEPA) It was determined that Brigham City’s Upper Hydroelectric Power Plant upgrade would have no effect to federally listed or candidate species. However Brigham City has contributed a onetime lump sum towards Bonneville cutthroat trout conservation in the Northern Bonneville Geographic Management Unit with the intention to offset any impacts from the Upper Hydro Project needed to move forward with design and construction and is sufficient for NEPA compliance. No work was done in the river or river bank. During construction, the penstock was disconnected and water was diverted through and existing system around the powerhouse and back into the water system. The penstock, which is currently a 30-inch steel pipe, would be removed and replaced with a new section of 30-inch pipe. Brigham City worked with the DOE and was awarded a new modification and the permission to proceed with Phase III of our Hydro Project in Dec. 2013; with the exception to the modification of the award for the construction phase. Brigham City developed and issued a Request for Proposal for Engineer and Design vendor. Sunrise Engineering was selected for the Design and throughout the Construction Phase of the Upper Hydroelectric Power Plant. Brigham City conducted a Kickoff Meeting with Sunrise June 28, 2013 and received a Scope of Work Brigham City along with engineering firm sent out a RFP for Turbine, Generator and Equipment for Upper Hydro. We select Turbine/Generator Equipment from Canyon Industries located in Deming, WA. DOE awarded Brigham City a new modification and the permission to proceed with Phase III Construction of our Hydro Project. Brigham City Crews removed existing turbine/generator and old equipment alone with feeder wires coming into the building basically giving Caribou Construction an empty shell to begin demolition. Brigham City contracted with Caribou Construction from Jerome, Idaho for the Upper Power Plant construction. A kickoff meeting was June 24, 2014 and demolition was immediately started on building. Because of a delivery delay of Turbine, Generator and Equipment from Canyon Brigham City had to request another extension for the final date of completion. DOE awarded modification (.007) to Brigham City with a new completion date of August 1, 2015. The Turbine has had a few adjustments to help with efficiency; but the Generator had a slight vibration when generator got hot so Canyon Industries had U S Motor’s that manufactured the generator come to check out the issue. The other Equipment seems to be running normal. Brigham City, Sunrise Engineering and Canyon Industries met to determine what the vibration in the generator was and how to solve the issue Us Motor’s found some welds that failed: they have been repaired. U S Motor’s delivered the repaired generator Feb. 17, 2015. Canyon Industries arranged for a crane to installed generator in Power Plant. U S Motor’s balanced and wired generator. Plant Operators put the generator back on line. Canyon Industries returned and gave their approval to keep Hydro online. After Hydro was put back into operations it kept going off line because of overheating issues. Canyon Industries returned and replaced sensors and adjusted them to the proper settings for normal operations. Brigham City added additional steel screens to windows to increase air flow in Power Plant Building. After construction phase of the Upper Hydro Plant some landscaping has been restored around the building additional gravel brought in and leveled out and the road that was cut through for conduits to run wires. A retaining wall was installed to protect penstock. The Upper Hydro Plant is complete and in full operations. The final reimbursement was submitted.

13 HYDRO ENERGY↗

Thermal Modeling of a Dual-Stage Sodium Thermal-Electrochemical Converter (Na-TEC)

The sodium thermal electrochemical converter (Na-TEC) is a heat engine that generates electricity through the isothermal expansion of sodium ions through a beta”-alumina solid-electrolyte. The Na-TEC is a closed system that can theoretically achieve conversion efficiencies above 45% when operating between thermal reservoirs at 1150 K and 550 K. However, thermal designs have confined previous single-stage devices to thermal efficiencies below 20%. To mitigate some of these limitations, we consider dividing the isothermal expansion into two stages; one at the evaporator temperature (1150 K) and another at an intermediate temperature (550 K – 950 K). This dual-stage Na-TEC takes advantage of regeneration and reheating, and could be amenable to better thermal management through a reduction of parasitic losses. These losses are comprised of (i) the heat input that does not participate in power production but simply bypasses the thermo-electrochemical process and is transferred to the condenser, and (ii) heat that is lost from the device directly to the surroundings due to poor insulation. Heat loss to the surroundings occurs from a lower average hot-side temperature given that a fraction of the power conversion occurs at an intermediate stage. Also, the condenser now directly interacts with the lower temperature of the intermediate stage, thereby reducing radiation loss. A simplified geometry is developed for this device to help guide its design from a heat transfer perspective. All thermal contact and boundary conditions are discussed, including the evaporation and condensation of sodium vapor, thermal leakage through the housing, and the thermal contact between the beta”-alumina and the housing. A ray tracing method assuming gray, diffuse surfaces is used to account for the internal radiation heat transfer within the device. Liquid sodium flows in a capillary wick between the condenser and the evaporator with Pe << 1, so only conduction heat transfer is considered within this liquid return path. For simplicity, natural convection between the sodium vapor and the device housing is neglected. A numerical linear resistance model (<5% error when compared to a finite element model) is used to determine the expected conversion temperatures of each stage for a range of candidate materials. Furthermore, a numerical model (<2% error) is developed to find the factor of increase in the thermal resistance for several designs of corrugated features for the device housing. By using an iterative scheme, efficiency vs. power curves are created for a number of material and size combinations. Finally, the fundamental tradeoff between the power and efficiency is explored in conjunction with the total system size.

14 SOLAR ENERGY↗