Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Convincing Clients to Make Zero a Reality: Preprint

As buildings are the largest end-users of carbon-intensive energy in the United States, it is critical that design and construction professionals implement energy-efficient and sustainable building designs and systems. Building owners seeking building energy performance improvements, either with new construction or retrofit of existing facilities, usually need the expertise of design and construction professionals to guide them through the process. These "trusted advisers" make the design decisions that ultimately result in the energy performance of the building. Members of the design and construction community have identified that clients' perception of cost associated with such designs and building upgrades have posed the most significant barrier to increased adoption. If solved, this would enable design and construction firms to better engage as trusted advisors along the lines of energy and carbon reduction of the built environment. NREL has developed a resource that helps design and construction professionals and their clients match their projects with financial incentives. A newly developed cohort of design and construction professionals, as part of the U.S. Department of Energy's Better Buildings Initiative, has brought real-world project experiences to the development process, contributing meaningful insights that have been critical to evaluating the successes of and providing direction to this much needed financial guide.

Better Buildings↗

Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Final Report: Cooling Seasonal Energy and Peak Demand Impacts of Improved Duct Insulation on Fixed-Capacity (SEER 13) and Variable-Capacity (SEER 22) Heat Pumps

A new generation of full variable-capacity, central, ducted air-conditioning (AC) and heat pump units has come on the market, and they promise to deliver increased cooling (and heating) efficiency. They are controlled differently than standard single-capacity (fixed-capacity) systems. Instead of cycling on at full capacity and then cycling off when the thermostat is satisfied, they can vary their capacity over a wide range (approximately 40% to 118% of nominal full capacity), thus staying “on” for up to twice as many hours per day compared to fixed-capacity systems of the same nominal capacity. The heating and cooling capacity is varied by adjusting the indoor fan air flow rate, compressor, and refrigerant flow rate as well as the outdoor unit fan air flow rate. Note that two-stage AC or heat pump systems were not evaluated in this research effort. The term dwell is used to refer to the amount of time distributed air spends inside ductwork during space-conditioning cycles. Longer run times mean greater dwell time and therefore greater exposure to conductive gains and losses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online Verification of Transactive Control for Commercial Buildings

Commercial buildings account for a significant portion of electrical energy demand in the United States. Thus, they serve as an ideal target for energy efficiency improvements, which can reduce congestion on the electrical grid and result in lower payments for building owners. One of the proposed approaches to improving energy efficiency in commercial buildings is transactive control, which allows system components to negotiate for resources within a market. The market is designed so that the control objective is met when components consume their allocation of energy. In this paper, a method is proposed to verify that the consumption of market participants matches their allocation. The method regards energy allocations at the beginning of market periods as predictions. Using collected measurements, actual consumption is then estimated at the end of the market period. Agreement between the predicted and estimated use indicates that the system component is behaving as expected. Initial results from the deployment of this verification method in a commercial building are reported, demonstrating the practicality and utility of the method.

Follum, James D.↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

Rapid deployment of residential photovoltaic (PV) systems helps decarbonize our electricity supplies, but under certain circumstances, high-penetration PV may pose challenges to the electrical distribution grid. In a project funded by the U.S. Department of Energy's Solar Energy Technologies Office and Building Technologies Office, the National Renewable Energy Laboratory and its partners studied how flexible building loads and battery storage, when coordinated at home-level and community-level scales, can be used to address those challenges and enhance grid resilience. In this webinar, we will discuss the methodology, simulation and field pilot results, insights from partners, and lessons learned from the project.

artificial intelligence↗

Direct measurement of building transient and residual drift using an optical sensor system

Interstory drift (ID) is a key response parameter for buildings subjected to lateral loads and is used to define performance-based limit states, allowable deformations and damage states in a number of seismic design codes and standards. Here, an ability to rapidly and accurately measure both transient and residual ID during an earthquake would provide important observables for understanding the seismic demands and post-earthquake condition of a building. Accurate retrieval of ID from accelerometer-based instrumentation systems can be very challenging, if not impossible, as a result of instrumentation limitations and the post-processing associated with strong motion accelerometer data. This is particularly true for the case in which residual drifts occur during inelastic building response. In the study presented herein, a newly developed optical sensor system, designed specifically for directly measuring both transient and residual ID, was experimentally evaluated through shake table testing and computational simulations. The ability of the sensor to accurately measure ID is demonstrated and key operational considerations for sensor system deployment are examined through a model-based investigation.

42 ENGINEERING↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗

Water Resource Assessment of Geothermal Resources and Water Use in Geopressured Geothermal Systems (Rev.1)

With a potential threefold increase in geothermal electricity generation by 2035, geothermal energy is increasingly recognized for its potential to reduce carbon emissions (EIA 2011a). Energy and environmental analyses are critical to developing a robust set of geothermal energy technologies that meet future demand. Previous work has summarized what is currently known about the life-cycle freshwater requirements of geothermal power-generating systems and the water quality of geothermal waters. This report builds upon that work, presenting an assessment of freshwater demand for future growth in utility-scale geothermal power generation and an analysis of freshwater use in low-temperature geopressured geothermal power generation systems. This is part of a larger effort to compare the life-cycle impacts of geothermal electricity generation with other power generation technologies. This report is organized with an introduction followed by two primary analysis sections. The introduction gives the background of the project and its purpose and summarizes the geothermal electricity generation technologies evaluated in this study. These technologies include conventional hydrothermal flash and binary systems, enhanced geothermal systems (EGS), and geopressured geothermal systems.

15 GEOTHERMAL ENERGY↗

Practical challenges of model predictive control (MPC) for grid interactive small and medium commercial buildings

To the urgent call for mitigating climate change, substantial initiatives have been undertaken to deploy grid-interactive heating, ventilation, and air-conditioning (HVAC) controls, such as model predictive control (MPC) for buildings. These efforts typically aim to curtail peak energy demand, shift load and enhance overall energy efficiency. With the recent development of low-cost MPC technologies that don’t require extensive instrumentation or manual modeling, small and medium commercial buildings (SMCBs), which rarely utilize advanced HVAC control systems, have become candidates for grid-interactive efficient buildings (GEBs). However, despite the potential benefits and maturity of the technology itself, several practical challenges remain in real-world implementation. In this paper, we share the practical challenges that we have encountered in implementing and testing three types of MPC solutions (ON/OFF unit, dualfuel, and VRF systems) on multiple SMCB sites. We describe the MPC deployment process and discuss the lessons learned. The site selection, eligibility, and retrofit availability (e.g., utility price structure, thermostat communications, etc.) are the main discussion points at the beginning of the project. Also, the modeling automation and the best practices for interacting with endusers and handling erroneous situations are presented for successful operations.

woo Ham, Sang↗

Optimizing mixed cool thermal storage systems across a connected community

A high level of electric demand flexibility must be integrated into our building infrastructure to enable greater renewable energy penetration in the grid. In the U.S., 9% of electricity generated is used to cool buildings in a periodic manner, making this end-use an ideal target for active management through cool thermal energy storage (CTES) technologies. Historic uses for CTES are designed around central chilled water plants, but these systems cool less than 25% of U.S. commercial floorspace. Emerging technologies are under development to serve the many smaller distributed cooling systems, such as rooftop units (RTUs), and have the potential to add CTES to an additional 66% of cooled commercial floorspace. However, these unitary thermal storage systems (UTSS) lack the modeling and analysis tools to evaluate them in the future interactive grid context. Here, this study develops the modeling and optimization tools necessary to simultaneously examine central and distributed ice storage systems within the multi-building, connected community context. An integrated simulation-optimization workflow is created to allow for rapid customized analysis. Results demonstrate the energy and flexibility tradeoffs of various implementations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

All-temperature zinc batteries with high-entropy aqueous electrolyte

Electrification of transportation and rising demand for grid energy storage continue to build momentum around batteries across the globe. However, the supply chain of Li-ion batteries is exposed to the increasing challenges of resourcing essential and scarce materials. Therefore, incentives to develop more sustainable battery chemistries are growing. Here, in this paper, we show an aqueous ZnCl 2 electrolyte with introduced LiCl as supporting salt. Once the electrolyte is optimized to Li 2 ZnCl 4 ∙9H 2 O, the assembled Zn–air battery can sustain stable cycling over the course of 800 hours at a current density of 0.4 mA cm -2 between -60 °C and +80 °C, with 100% Coulombic efficiency for Zn stripping/plating. Even at -60 °C, >80% of room-temperature power density can be retained. Advanced characterization and theoretical calculations reveal a high-entropy solvation structure that is responsible for the excellent performance. The strong acidity allows ZnCl 2 to accept donated Cl - ions to form ZnCl 4 2- anions, while water molecules remain within the free solvent network at low salt concentration or coordinate with Li ions. Our work suggests an effective strategy for the rational design of electrolytes that could enable next-generation Zn batteries.

25 ENERGY STORAGE↗

Conceptual Architecture of Building Energy Management Open Source Software (BEMOSS)

The objective of this paper is to present a conceptual architecture of a Building Energy Management Open Source Software (BEMOSS) platform. The proposed BEMOSS platform is expected to improve sensing and control of equipment in small- and medium-sized buildings, reduce energy consumption and help implement demand response (DR). It aims to offer: scalability, robustness, plug and play, open protocol, interoperability, cost-effectiveness, as well as local and remote monitoring. In this paper, four essential layers of BEMOSS software architecture -- namely User Interface, Application and Data Management, Operating System and Framework, and Connectivity layers -- are presented. A laboratory test bed to demonstrate the functionality of BEMOSS located at the Advanced Research Institute of Virginia Tech is also briefly described.

agents↗

Automated Measurement and Signaling Systems for the Transactional Network

The Transactional Network Project is a multi-lab activity funded by the US Department of Energy's Building Technologies Office. The project team included staff from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory and Oak Ridge National Laboratory. The team designed, prototyped and tested a transactional network (TN) platform to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). PNNL was responsible for the development of the TN platform, with agents for this platform developed by each of the three labs. LBNL contributed applications to measure the whole-building electric load response to various changes in building operations, particularly energy efficiency improvements and demand response events. We also provide a demand response signaling agent and an agent for cost savings analysis. LBNL and PNNL demonstrated actual transactions between packaged rooftop units and the electric grid using the platform and selected agents. This document describes the agents and applications developed by the LBNL team, and associated tests of the applications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2011 Wind Technologies Market Report

The U.S. wind power industry is facing uncertain times. With 2011 capacity additions having risen from 2010 levels and with a further sizable increase expected in 2012, there are – on the surface – grounds for optimism. Key factors driving growth in 2011 included continued state and federal incentives for wind energy, recent improvements in the cost and performance of wind power technology, and the need to meet an end-of-year construction start deadline in order to qualify for the Section 1603 Treasury grant program. At the same time, the currently-slated expiration of key federal tax incentives for wind energy at the end of 2012 – in concert with continued low natural gas prices and modest electricity demand growth – threatens to dramatically slow new builds in 2013.

17 WIND ENERGY↗

Technical Advisor to the American Indian Research and Education Initiatives (AIREI).

The American Indian Research & Education Initiative (AIREI) is a pilot program that started in 2011 and is funded by the US Department of Energy (DOE) Economic Impact & Diversity and National Nuclear Security Administration in partnership with the American Indian Higher Education Consortium (AIHEC) and the American Indian Science and Engineering Society. AIREI brings science, technology, engineering, and mathematics (STEM) research and education funding to Tribal Colleges and Universities (TCU) and other US universities. AIREI has funded eight schools, including four pairs of tribal colleges and mainstream universities, in order for student and faculty research teams to bring energy projects to tribal lands. The research team from Southwest Indian Polytechnic Institute (SIPI) and Northern Arizona University (NAU) has performed a student-centric research and analysis feasibility study of a potential utility-scale solar power plant on the Jemez Pueblo reservation trust land. The research team from Navajo Technical University (NTU) and Arizona State University (ASU) has assessed the effectiveness of solar photovoltaic (PV) system designs in meeting the electricity demands of Navajo Tribal homes and public buildings in addition to the development of a solar technology curriculum that incorporates the outcomes of this study, helping to advance PV system design and installations on local Tribal lands. The Little Big Horn College (LBHC) and Montana State University-Bozeman (MSUB) team has developed fast growing strains of nitrogen-fixing cyanobacteria to help advance carbon capture and sequestration (CCS) technologies. The research supported the Crow Nation reservation as it evaluates opportunities for coal-to-liquid fuel and CCS projects. The Sinte Gleska University (SGU) and South Dakota School of Mines (SDSM) team developed computer modeling and simulation technologies to evaluate the feasibility of oil and gas development from the Niobrara Formation on the Rosebud Sioux reservation. Through this project, the students developed skills in applied energy-related research involving computer simulation, chemistry, geology, and petroleum engineering. AIREI supports collaboration between these universities and connects the teams with the technological expertise and mentorship opportunities provided through Sandia National Laboratories (Sandia). AIHEC consists of 37 American Indian tribally controlled colleges around the nation and provides technical assistance through professional development workshops, strategic planning meetings, and information sharing strategies.

99 GENERAL AND MISCELLANEOUS↗

Development of a Testing Protocol for C7 Carbon Fiber Core Conductors

To avoid the high costs and environmental and regulatory challenges of building new lines to meet the power demand, utilities are searching for ways to increase power transmission capacity on existing lines and thereby. This could involve upgrading the network lines with conductors capable of transmitting greater capacity. In recent years, conductor manufacturers have begun producing new conductors that can operate at higher temperatures without violating present electrical clearances to ground and other objects. One new conductor technology is a carbon composite core with PPS polymer matrix and PEEK capping layer composite conductor, manufactured by Southwire Inc. The conductor uses new materials, which have not previously been used for overhead lines. The project made an initial characterization of the composite core to define the material used in the manufacture of the composite. Several analytical procedures were then conducted to evaluate the physical-chemical impacts on the composite as a result of thermal exposure. These procedures included thermogravimetry, dynamic mechanical analysis, thermal mechanical analyses, and optical microscopy. Mechanical three-point flexural tests, tensile tests, creep tests, and dynamic vibration tests were then performed to estimate the potential degradation after thermal aging. The report provides the basis to develop a qualification testing protocol for the carbon composite core at targeted service environments. The work covers the design of the qualification testing protocol and the follow-on validation testing to support the proposed methods. The research includes the following approaches: initial characterization, performance of thermal aging, characterization of the aged material, comparison of aged properties or characteristics to the original, and concluding by the findings through the developed qualification procedures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Status of NASA SCaN's Efforts to Integrate Commercial Satellite Communication Service Providers Into the Near Space Network

The National Aeronautics and Space Administration’s (NASA) Space Communication and Navigation (SCaN) program intends to deliver operationally ready commercial space-based communications relay services to missions by 2031. The high-throughput, demand-responsive networks that commercial providers are building and operating will remove long-standing network constraints, enhancing mission capability and data-return.

Near Space Network↗

Where and When Does Solar Plus Storage Make Sense for Commercial Buildings?

As the capital cost of battery energy storage systems (BESS) declines, opportunities for commercial buildings to achieve net savings through peak demand management and energy arbitrage are emerging. National Renewable Energy Laboratory researchers modeled energy storage project economics - with and without accompanying solar photovoltaic systems - using local utility rates, ASHRAE climate zones, and solar intensity data to identify regions where these systems deliver life cycle savings now and in future cost scenarios.

battery energy storage systems↗