Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BASE PRESSURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Supersonic pressure measurements and comparison of theory to experiment for an arrow-wing configuration

A wind tunnel test of an arrow-wing-body configuration consisting of flat and twisted wings, as well as leading- and trailing-edge control surface deflections, was conducted at Mach numbers from 1.54 to 2.50 to provide an experimental pressure data base for comparison with theoretical methods. Theory-to-experiment comparisons of detailed pressure distributions were made using a state-of-the-art inviscid flow, constant-pressure-panel method. Emphasis was on conditions under which this theory is valid for both flat and twisted wings.

Manro, M. E.↗

Thoracic Pressure Does Not Impact CSF Pressure via Compartment Compliance

Space acquired neuro-ocular syndrome (SANS) remains a difficult risk to characterize due to the complex multi-factorial etiology related to physiological responses to the spaceflight environment. Fluid shift and the resultant change on the Cardiovascular (CV) and cerebral spinal fluid systems (CSF) in the absence of gravity continue to be considered a contributing factor to the progression of SANS. In this study, we utilize a computational model of the CSF and CV interface to establish the sensitivity that intracranial pressure, and subsequently the optic nerve sheath pressure, exhibits due to variations in thoracic pressure, assuming the cranial perfusion pressure, i.e. mean arterial pressure (MAP) to central venous pressure (CVP), is known. Methods: The GRC Cross cutting computational modeling project created as model of the CSF and CV interaction within the cranial vault by extending the work of Stevens et al. [1] by modifying the representative anatomy to include a separate venous sinus, jugular veins, secondary veins and extra jugular pathways [2-3] to more adequately represent the vascular drainage pathways from the cranial vault (Figure 1). Assuming the MAP, CVP and thoracic pressure are known, we initiated this enhanced computational model assuming a supine positon and utilized a linear ramp to vary the thoracic pressure from the assumed supine state to the target pressure corresponding to set MAP and CVP values. The model generates the time based CSF pressure values (Figure2). Results and Conclusions: Following this analysis, CSF pressure shows significant independence from thoracic pressure changes (16 mmHg in thoracic pressure produces < 1mmHg change in CSF pressure), being mostly dependent on perfusion pressure. Similarly fluid redistribution is not predicted to be impacted over a level of 1mL. We note that this simulation represents an acute changes (order of 10's of minutes) and does not represent the long term effects.

Munster, Drayton W.↗

A fast, matrix-based method to perform omnidirectional pressure integration

Abstract Experimentally-measured pressure fields play an important role in understanding many fluid dynamics problems. Unfortunately, pressure fields are difficult to measure directly with non-invasive, spatially resolved diagnostics, and calculations of pressure from velocity have proven sensitive to error in the data. Omnidirectional line integration methods are usually more accurate and robust to these effects as compared to implicit Poisson equations, but have seen slower uptake due to the higher computational and memory costs, particularly in 3D domains. This paper demonstrates how omnidirectional line integration approaches can be converted to a matrix inversion problem. This novel formulation uses an iterative approach so that the boundary conditions are updated each step, preserving the convergence behavior of omnidirectional schemes while also keeping the computational efficiency of Poisson solvers. This method is implemented in Matlab and also as a GPU-accelerated code in CUDA-C++. The behavior of the new method is demonstrated on 2D and 3D synthetic and experimental data. Three-dimensional grid sizes of up to 125 million grid points are tractable with this method, opening exciting opportunities to perform volumetric pressure field estimation from 3D PIV measurements.

42 ENGINEERING↗

Statistical characteristic in time-domain of direct current corona-generated audible noise from conductor in corona cage

The corona-generated audible noise (AN) has become one of decisive factors in the design of high voltage direct current (HVDC) transmission lines. The AN from transmission lines can be attributed to sound pressure pulses which are generated by the multiple corona sources formed on the conductor, i.e., transmission lines. In this paper, a detailed time-domain characteristics of the sound pressure pulses, which are generated by the DC corona discharges formed over the surfaces of a stranded conductors, are investigated systematically in a laboratory settings using a corona cage structure. The amplitude of sound pressure pulse and its time intervals are extracted by observing a direct correlation between corona current pulses and corona-generated sound pressure pulses. Based on the statistical characteristics, a stochastic model is presented for simulating the sound pressure pulses due to DC corona discharges occurring on conductors. The proposed stochastic model is validated by comparing the calculated and measured A-weighted sound pressure level (SPL). The proposed model is then used to analyze the influence of the pulse amplitudes and pulse rate on the SPL. Furthermore, a mathematical relationship is found between the SPL and conductor diameter, electric field, and radial distance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CERES Monthly Gridded Single Satellite Fluxes and Clouds (FSW) in HDF (CER_FSW_Terra-FM1-MODIS_Edition2C)

The Monthly Gridded Radiative Fluxes and Clouds (FSW) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The FSW is also produced for combinations of scanner instruments. All instantaneous fluxes from the CERES CRS product for a month are sorted by 1-degree spatial regions and by the Universal Time (UT) hour of observation. The mean of the instantaneous fluxes for a given region-hour bin is determined and recorded on the FSW along with other flux statistics and scene information. The mean adjusted fluxes at the four atmospheric levels defined by CRS are also included for both clear-sky and total-sky scenes. In addition, four cloud height categories are defined by dividing the atmosphere into four intervals with boundaries at the surface, 700-, 500-, 300-hPa, and the Top-of-the-Atmosphere (TOA). The cloud layers from CRS are put into one of the cloud height categories and averaged over the region. The cloud properties are also column averaged and included on the FSW. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2005-12-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Latitude_Resolution=1 degree; Longitude_Resolution=1 degree; Horizontal_Resolution_Range=100 km - < 250 km or approximately 1 degree - < 2.5 degrees; Temporal_Resolution=1 month; Temporal_Resolution_Range=Monthly - < Annual].

NET FLUX↗

Development of an automated high-temperature valveless injection system for online gas chromatography

A reliable method of sample introduction is presented for online gas chromatography with a special application to in situ field portable atmospheric sampling instruments. A traditional multi-port valve is replaced with a valveless sample introduction interface that offers the advantage of long-term reliability and stable sample transfer efficiency. An engineering design model is presented and tested that allows customizing this pressure-switching-based device for other applications. Flow model accuracy is within measurement accuracy (1%) when parameters are tuned for an ambient-pressure detector and 15% accurate when applied to a vacuum-based detector. Laboratory comparisons made between the two methods of sample introduction using a thermal desorption aerosol gas chromatograph (TAG) show that the new interface has approximately 3 times greater reproducibility maintained over the equivalent of a week of continuous sampling. Field performance results for two versions of the valveless interface used in the in situ instrument demonstrate typically less than 2% week -1 response trending and a zero failure rate during field deployments ranging up to 4 weeks of continuous sampling. Extension of the valveless interface to dual collection cells is presented with less than 3% cell-to-cell carryover.

Kreisberg, N. M.↗

CERES Monthly Gridded Single Satellite TOA and Surfaces/Clouds (SFC) data in HDF (CER_SFC_TRMM-PFM-VIRS_Beta4)

The Monthly Gridded TOA/Surface Fluxes and Clouds (SFC) product contains a month of space and time averaged Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The SFC is also produced for combinations of scanner instruments. All instantaneous shortwave, longwave, and window fluxes at the Top-of-the-Atmosphere (TOA) and surface from the CERES SSF product for a month are sorted by 1-degree spatial regions and by the local hour of observation. The mean of the instantaneous fluxes for a given region-hour bin is determined and recorded on the SFC along with other flux statistics and scene information. These average fluxes are given for both clear-sky and total-sky scenes. The regional cloud properties are column averaged and are included on the SFC. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2000-03-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=100] [Data_Resolution: Latitude_Resolution=1 degree; Longitude_Resolution=1 degree; Horizontal_Resolution_Range=100 km - < 250 km or approximately 1 degree - < 2.5 degrees; Temporal_Resolution=1 hour; Temporal_Resolution_Range=Hourly - < Daily].

NET FLUX↗

A versatile photoelectron spectrometer for pressures up to 30 mbar

High-pressure photoelectron spectroscopy is a rapidly developing technique with applications in a wide range of fields ranging from fundamental surface science and catalysis to energy materials, environmental science, and biology. At present the majority of the high-pressure photoelectron spectrometers are situated at synchrotron end stations, but recently a small number of laboratory-based setups have also emerged. In this paper we discuss the design and performance of a new laboratory based high pressure photoelectron spectrometer equipped with an Al Kα X-ray anode and a hemispherical electron energy analyzer combined with a differentially pumped electrostatic lens. The instrument is demonstrated to be capable of measuring core level spectra at pressures up to 30 mbar. Moreover, valence band spectra of a silver sample as well as a carbon-coated surface (graphene) recorded under a 2 mbar nitrogen atmosphere are presented, demonstrating the versatility of this laboratory-based spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the capillary pressure function in porous media based on relative permeabilities of two immiscible fluids: Application of capillary bundle models and validation using experimental data

The objective of this paper is to extend the theoretical approach and an analytical solution, which was proposed by Babchin and Faybishenko (2014), for the evaluation of a capillary pressure (P c ) curve in porous media based on the apparent specific surface area, using an explicit combination of the relative permeability functions for the wetting and nonwetting phases. Specifically, in the current paper, the authors extended this approach by the application of two types of capillary bundle models with different formulations of effective capillary radius formulae. The application of the new models allowed the authors to improve the results of calculations of the effective average contact angle given in the paper by Babchin and Faybishenko (2014). The validation of the new models for calculations of the P c curve is also given in this paper using the results of a specifically designed core experiment, which was originally conducted by Ayub and Bentsen (2001).

58 GEOSCIENCES↗

Revealing CO 2 dissociation pathways at vicinal copper (997) interfaces

Size- and shape-tailored copper (Cu) nanocrystals can offer vicinal planes for facile carbon dioxide (CO 2 ) activation. Despite extensive reactivity benchmarks, a correlation between CO 2 conversion and morphology structure has not yet been established at vicinal Cu interfaces. Herein, ambient pressure scanning tunneling microscopy reveals step-broken Cu nanocluster evolutions on the Cu(997) surface under 1 mbar CO 2 (g). The CO 2 dissociation reaction produces carbon monoxide (CO) adsorbate and atomic oxygen (O) at Cu step-edges, inducing complicated restructuring of the Cu atoms to compensate for increased surface chemical potential energy at ambient pressure. The CO molecules bound at under-coordinated Cu atoms contribute to the reversible Cu clustering with the pressure gap effect, whereas the dissociated oxygen leads to irreversible Cu faceting geometries. Synchrotron-based ambient pressure X-ray photoelectron spectroscopy identifies the chemical binding energy changes in CO-Cu complexes, which proves the characterized real-space evidence for the step-broken Cu nanoclusters under CO(g) environments. Our in situ surface observations provide a more realistic insight into Cu nanocatalyst designs for efficient CO 2 conversion to renewable energy sources during C 1 chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CERES Clouds and Radiative Swath (CRS) data in HDF. (CER_CRS_Terra-FM2-MODIS_Edition2B)

The Clouds and Radiative Swath (CRS) product contains one hour of instantaneous Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The CRS contains all of the CERES SSF product data. For each CERES footprint on the SSF the CRS also contains vertical flux profiles evaluated at four levels in the atmosphere: the surface, 500-, 70-, and 1-hPa. The CRS fluxes and cloud parameters are adjusted for consistency with a radiative transfer model and adjusted fluxes are evaluated at the four atmospheric levels for both clear-sky and total-sky. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2001-10-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 hour; Temporal_Resolution_Range=Hourly - < Daily].

SHORTWAVE UNFILTERED RADIANCE↗

In Situ Studies of Methanol Decomposition Over Cu(111) and Cu2O/Cu(111): Effects of Reactant Pressure, Surface Morphology, and Hot Spots of Active Sites

The dissociative adsorption of methanol was investigated on Cu(111) and ultrathin Cu 2 O films. We employed synchrotron-based Ambient Pressure X-ray Photoelectron Spectroscopy (AP-XPS) and Scanning Tunneling Microscopy (STM) to study the dynamics of gas–solid interactions, and calculations based on Density Functional Theory (DFT) were used to examine the reaction path. C 1s XPS spectra revealed that methanol underwent dissociative adsorption on plain Cu(111) to form methoxy (CH 3 O), formaldehyde (H 2 CO), and formate (HCOO) at a pressure range of 0.5–10 mTorr, with these species remaining on the surface after evacuation. This was accompanied by the appearance of a low coverage (~0.05 ML) of O ads in the O 1s which can be considered a highly active site for methanol activation. The high activity is apparent by a coverage of 0.8 ML of methoxy at room temperature. STM was unable to image these species at room temperature as they were highly mobile on metallic copper. In contrast, for CH 3 OH on Cu 2 O/Cu(111), STM showed clear hot spots for reaction and a complex array of adsorption structures. On the oxide substrate, there was decomposition of methanol to H 2 CO, CH 3 O, HCOO, and hydrocarbon species (CH x ) due to the subsequent interactions of methanol with lattice oxygen. Cu(111) remained entirely saturated with decomposition products under 10 mTorr of methanol (θ ≈ 0.97 ML), whereas the Cu 2 O overlayer was saturated at a much lower coverage (θ ≈ 0.30 ML). STM revealed rows and step edges of Cu 2 O decorated with decomposition products and metallic Cu islands ~5 nm in size. The difference in activity between Cu(111) and Cu 2 O/Cu(111) is attributed to the significant amount of O present on the oxide surface. Additionally, Density Functional theory (DFT) calculations described the XPS measurements well, showing a likely methanol dissociation to *CH 3 O and therefore a surface reduction. More importantly, the DFT results revealed that it was the chemisorbed oxygen on Cu 2 O/Cu(111) which oxidized the dissociated *CH 3 O to *HCOO and eventually CO 2 , while the reaction only involving upper oxygen on the Cu 2 O hexagonal ring led to the formation of H 2 CO.

36 MATERIALS SCIENCE↗

LiPF 6 under pressure: a symmetry-mode-based structural analysis

The lithium salt LiPF 6 is a key component in commercial lithium-ion battery (LIB) electrolytes. However, its structural properties under pressure remain unexplored, despite increasing interest in the effect of pressure on electrolyte behaviour, and a growing interest in high pressure synthesis of new Li-hexafluoride cathode materials. Here, we present the first high pressure neutron diffraction study of solid LiPF 6 up to 7.4 GPa. Refinements reveal that the ambient rhombohedral structure (space group R$\overline{3}$) remains stable throughout, with pressure accommodated primarily by tilting of the corner-shared LiF 6 and PF 6 octahedra and contraction of the LiF 6 units. In conclusion, this study establishes a foundation for understanding the phase behaviour of Li-based hexafluorides under extreme conditions.

25 ENERGY STORAGE↗

CERES Clouds and Radiative Swath (CRS) data in HDF (CER_CRS_TRMM-PFM-VIRS_Edition2C)

The Clouds and Radiative Swath (CRS) product contains one hour of instantaneous Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The CRS contains all of the CERES SSF product data. For each CERES footprint on the SSF the CRS also contains vertical flux profiles evaluated at four levels in the atmosphere: the surface, 500-, 70-, and 1-hPa. The CRS fluxes and cloud parameters are adjusted for consistency with a radiative transfer model and adjusted fluxes are evaluated at the four atmospheric levels for both clear-sky and total-sky. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2000-03-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 hour; Temporal_Resolution_Range=Hourly - < Daily].

ICE PARTICLE DIAMETER↗

CERES Single Scanner Satellite Footprint, TOA, Surface Fluxes and Clouds (SSF) data in HDF (CER_SSF_Terra-FM2-MODIS_Edition2A)

The Single Scanner Footprint TOA/Surface Fluxes and Clouds (SSF) product contains one hour of instantaneous Clouds and the Earth's Radiant Energy System (CERES) data for a single scanner instrument. The SSF combines instantaneous CERES data with scene information from a higher-resolution imager such as Visible/Infrared Scanner (VIRS) on TRMM or Moderate-Resolution Imaging Spectroradiometer (MODIS) on Terra and Aqua. Scene identification and cloud properties are defined at the higher imager resolution and these data are averaged over the larger CERES footprint. For each CERES footprint, the SSF contains the number of cloud layers and for each layer the cloud amount, height, temperature, pressure, optical depth, emissivity, ice and liquid water path, and water particle size. The SSF also contains the CERES filtered radiances for the total, shortwave (SW), and window (WN) channels and the unfiltered SW, longwave (LW), and WN radiances. The SW, LW, and WN radiances at spacecraft altitude are converted to Top-of-the-Atmosphere (TOA) fluxes based on the imager defined scene. These TOA fluxes are used to estimate surface fluxes. Only footprints with adequate imager coverage are included on CER_SSF_TRMM-PFM-VIRS_Subset_Edition1the SSF which is much less than the full set of footprints on the CERES ES-8 product. The following CERES SSF data sets are currently available: CER_SSF_TRMM-PFM-VIRS_Edition1 CER_SSF_TRMM-PFM-VIRS_Subset_Edition1 CER_SSF_TRMM-PFM-VIRS_Edition2A CER_SSF_TRMM-SIM-VIRS_Edition2_VIRSonly CER_SSF_TRMM-PFM-VIRS_Edition2A-TransOps CER_SSF_TRMM-PFM-VIRS_Edition2B-TransOps CER_SSF_TRMM-PFM-VIRS_Edition2B CER_SSF_Terra-FM1-MODIS_Edition1A CER_SSF_Terra-FM1-MODIS_Edition1A CER_SSF_Terra-FM1-MODIS_Edition2A CER_SSF_Terra-FM2-MODIS_Edition2A CER_SSF_Terra-FM1-MODIS_Edition2B CER_SSF_Terra-FM2-MODIS_Edition2B CER_SSF_Aqua-FM4-MODIS_Beta1 CER_SSF_Aqua-FM3-MODIS_Beta2 CER_SSF_Aqua-FM4-MODIS_Beta2. [Location=GLOBAL] [Temporal_Coverage: Start_Date=1998-01-01; Stop_Date=2003-12-31] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180] [Data_Resolution: Temporal_Resolution=1 hour; Temporal_Resolution_Range=Hourly - < Daily].

SURFACE (RADIATIVE) FLUX↗

Development Plan for Ultrasonic Pressure Sensors [Slides]

Current light water reactors (LWRs) utilize differential pressure cells, based on strain gauges, which are remotely located from the reactor vessel via impulse lines. These pressure sensors are used to measure liquid level within the vessel and to give a general indication of system health with regard to leaks and flow system fouling. The advanced reactor types currently under development generally operate at higher temperatures than light-water reactors and utilize coolants that may be highly corrosive (i.e., liquid metals). They will use pressure measurements for varied measurands, such as level and flow rate, as well as indications of accident conditions or off-normal operating conditions. More robust pressure sensors are needed to address these more challenging conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗