Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Analytic Minkowski functionals of the cosmic microwave background: Second-order non-Gaussianity with bispectrum and trispectrum

Analytic formulas of Minkowski functionals in two-dimensional random fields are derived, including effects of second-order non-Gaussianity in the presence of both the bispectrum and trispectrum. The set of formulas provides a promising method to constrain the primordial non-Gaussianity of the universe by temperature fluctuations in the cosmic microwave background radiation. In a case of local-type non-Gaussianity, the Minkowski functionals are analytically given by powers of quadratic and cubic parameters, f{sub NL} and g{sub NL} (and {tau}{sub NL}). Our formulas are not restricted to this particular model, and applicable to a wide class of non-Gaussian models. The analytic formulas are compared to numerical evaluations from non-Gaussian realizations of temperature maps, showing very good agreement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraints on cosmological models and reconstructing the acceleration history of the Universe with gamma-ray burst distance indicators

Gamma-ray bursts (GRBs) have been regarded as standard candles at very high redshift for cosmology research. We have proposed a new method to calibrate GRB distance indicators with Type Ia supernova (SNe Ia) data in a completely cosmology-independent way to avoid the circularity problem that had limited the direct use of GRBs to probe cosmology [N. Liang, W. K. Xiao, Y. Liu, and S. N. Zhang, Astrophys. J. 685, 354 (2008).]. In this paper, a simple method is provided to combine GRB data into the joint observational data analysis to constrain cosmological models; in this method those SNe Ia data points used for calibrating the GRB data are not used to avoid any correlation between them. We find that the {Lambda}CDM model is consistent with the joint data in the 1-{sigma} confidence region, using the GRB data at high redshift calibrated with the interpolating method, the Constitution set of SNe Ia, the cosmic microwave background radiation from Wilkinson Microwave Anisotropy Probe five year observation, the baryonic acoustic oscillation from the spectroscopic Sloan Digital Sky Survey Data Release 7 galaxy sample, the x-ray baryon mass fraction in clusters of galaxies, and the observational Hubble parameter versus redshift data. Comparing to the joint constraints with GRBs and without GRBs, we find that the contribution of GRBs to the joint cosmological constraints is a slight shift in the confidence regions of cosmological parameters to better enclose the {Lambda}CDM model. Finally, we reconstruct the acceleration history of the Universe up to z>6 with the distance moduli of SNe Ia and GRBs and find some features that deviate from the {Lambda}CDM model and seem to favor oscillatory cosmology models; however, further investigations are needed to better understand the situation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Circles-in-the-sky searches and observable cosmic topology in a flat universe

In a universe with a detectable nontrivial spatial topology, the last scattering surface contains pairs of matching circles with the same distribution of temperature fluctuations--the so-called circles-in-the-sky. Searches for nearly antipodal circles-in-the-sky in maps of cosmic microwave background radiation have so far been unsuccessful. This negative outcome, along with recent theoretical results concerning the detectability of nearly flat compact topologies, is sufficient to exclude a detectable nontrivial topology for most observers in very nearly flat positively and negatively curved universes, whose total matter-energy density satisfies 0<|{Omega}{sub tot}-1| < or approx. 10{sup -5}. Here, we investigate the consequences of these searches for observable nontrivial topologies if the Universe turns out to be exactly flat ({Omega}{sub tot}=1). We demonstrate that in this case, the conclusions deduced from such searches can be radically different. We show that, although there is no characteristic topological scale in the flat manifolds, for all multiply-connected orientable flat manifolds, it is possible to directly study the action of the holonomies in order to obtain a general upper bound on the angle that characterizes the deviation from antipodicity of pairs of matching circles associated with the shortest closed geodesic. This bound is valid for all observers and all possible values of the compactification length parameters. We also show that in a flat universe, there are observers for whom the circles-in-the-sky searches already undertaken are insufficient to exclude the possibility of a detectable nontrivial spatial topology. It is remarkable how such small variations in the spatial curvature of the Universe, which are effectively indistinguishable geometrically, can have such a drastic effect on the detectability of cosmic topology. Another important outcome of our results is that they offer a framework with which to make statistical inferences from future circles-in-the-sky searches on whether the Universe is exactly flat.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Testing general relativity with current cosmological data

Deviations from general relativity, such as could be responsible for the cosmic acceleration, would influence the growth of large-scale structure and the deflection of light by that structure. We clarify the relations between several different model-independent approaches to deviations from general relativity appearing in the literature, devising a translation table. We examine current constraints on such deviations, using weak gravitational lensing data of the CFHTLS and COSMOS surveys, cosmic microwave background radiation data of WMAP5, and supernova distance data of Union2. A Markov chain Monte Carlo likelihood analysis of the parameters over various redshift ranges yields consistency with general relativity at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Strongly scale-dependent non-Gaussianity

We discuss models of primordial density perturbations where the non-Gaussianity is strongly scale dependent. In particular, the non-Gaussianity may have a sharp cutoff and be very suppressed on large cosmological scales, but sizable on small scales. This may have an impact on probes of non-Gaussianity in the large-scale structure and in the cosmic microwave background radiation anisotropies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inflation in string theory: A graceful exit to the real world

The most important criteria for a successful inflation are: explaining the observed temperature anisotropy in the cosmic microwave background radiation, and exiting inflation in a vacuum where it can excite the standard model quarks and leptons required for the success of big bang nucleosynthesis. In this paper, we provide the first ever closed-string model of inflation where the inflaton couplings to hidden sector, moduli sector, and visible sector fields can be computed, showing that inflation can lead to reheating the standard model degrees of freedom before the electro-weak scale.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

POLARBEAR constraints on cosmic birefringence and primordial magnetic fields

Here, we constrain anisotropic cosmic birefringence using four-point correlations of even-parity E-mode and odd-parity B-mode polarization in the cosmic microwave background measurements made by the POLARization of the Background Radiation (POLARBEAR) experiment in its first season of observations. We find that the anisotropic cosmic birefringence signal from any parity-violating processes is consistent with zero. The Faraday rotation from anisotropic cosmic birefringence can be compared with the equivalent quantity generated by primordial magnetic fields if they existed. The POLARBEAR nondetection translates into a 95% confidence level (C.L.) upper limit of 93 nanogauss (nG) on the amplitude of an equivalent primordial magnetic field inclusive of systematic uncertainties. This four-point correlation constraint on Faraday rotation is about 15 times tighter than the upper limit of 1380 nG inferred from constraining the contribution of Faraday rotation to two-point correlations of B-modes measured by Planck in 2015. Metric perturbations sourced by primordial magnetic fields would also contribute to the B-mode power spectrum. Using the POLARBEAR measurements of the B-mode power spectrum (two-point correlation), we set a 95% C.L. upper limit of 3.9 nG on primordial magnetic fields assuming a flat prior on the field amplitude. This limit is comparable to what was found in the Planck 2015 two-point correlation analysis with both temperature and polarization. Finally, we perform a set of systematic error tests and find no evidence for contamination. This work marks the first time that anisotropic cosmic birefringence or primordial magnetic fields have been constrained from the ground at subdegree scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

γ -ray Constraints on Decaying Dark Matter and Implications for IceCube

Utilizing the Fermi measurement of the γ -ray spectrum toward the Inner Galaxy, we derive some of the strongest constraints to date on the dark matter (DM) lifetime in the mass range from hundreds of MeV to above an EeV. Our profile-likelihood-based analysis relies on 413 weeks of Fermi Pass 8 data from 200 MeV to 2 TeV, along with up-to-date models for diffuse γ -ray emission within the Milky Way. We model Galactic and extragalactic DM decay and include contributions to the DM-induced γ -ray flux resulting from both primary emission and inverse-Compton scattering of primary electrons and positrons. For the extragalactic flux, we also calculate the spectrum associated with cascades of high-energy γ rays scattering off of the cosmic background radiation. We argue that a decaying DM interpretation for the 10 TeV–1 PeV neutrino flux observed by IceCube is disfavored by our constraints. Our results also challenge a decaying DM explanation of the AMS-02 positron flux. In conclusion, we interpret the results in terms of individual final states and in the context of simplified scenarios such as a hidden sector glueball model.

79 ASTRONOMY AND ASTROPHYSICS↗

Unlocking New Regimes in Fractional Quantum Hall Effect with Quaternions

We demonstrate that formulating the composite-fermion theory of the fractional quantum Hall (FQH) effect in terms of quaternions greatly expands its reach and opens the door into many interesting issues that were previously not amenable to quantitative theoretical investigation. As an illustration, we explore the possibility of a nematic or a charge-density wave instability of the composite-fermion Fermi sea at half-filled Landau level and of the nearby FQH states by looking for a gap closing instability of the neutral magneto-roton excitation. As a result, our quaternion formulation of the FQH effect has been inspired by mathematical developments in the theoretical analyses of gravitational wave modes and cosmic microwave background radiation, where an important role is played by spin-weighted spherical harmonics that are nothing but monopole harmonics appearing in the spherical geometry for the FQH effect.

Composite fermions↗

Testing sTGC with small angle wire edges for the ATLAS new small wheel muon detector upgrade

The LHC upgrade scheduled for 2018 is expected to significantly increase the accelerator's luminosity, and as a result the radiation background rates in the ATLAS Muon Spectrometer will increase too. Some of its components will have to be replaced in order to cope with these high rates. Newly designed small-strip Thin Gap chambers (sTGC) will replace them at the small wheel region. One of the differences between the sTGC and the currently used TGC is the alignment of the wires along the azimuthal direction. As a result, the outermost wires approach the detector's edge with a small angle. Such a configuration may be a cause for various problems. Two small dedicated chambers were built and tested in order to study possible edge effects that may arise from the new configuration. The sTGC appears to be stable and no spark have been observed, yet some differences in the detector response near the edge is seen and further studies should be carried out. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on ANL/KICP bolometers for SPTpol.

We present progress on Argonne/KICP TES bolometers fabricated at Argonne National Labs. These detectors will be used to measure the polarization of the Cosmic Microwave Background radiation with SPTpol. The sensors are bolometers consisting of a Mo/Au transition edge sensors (TES) suspended on silicon nitride with a gold bar absorber to couple radiation to the device. We present optical measurements and thermal characterizations of prototype devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MaGe-a Geant4-Based Monte Carlo Application Framework for Low-Background Germanium Experiments

We describe a physics simulation software framework, MAGE, that is based on the GEANT4 simulation toolkit. MAGE is used to simulate the response of ultra-low radioactive background radiation detectors to ionizing radiation, specifically the MAJ ORANA and GE RDA neutrinoless double-beta decay experiments. MAJ ORANA and GERDA use high-purity germanium technology to search for the neutrinoless double-beta decay of the 76 Ge isotope, and MAGE is jointly developed between these two collaborations. The MAGE framework contains simulated geometries of common objects, prototypes, test stands, and the actual experiments. It also implements customized event generators, GE ANT 4 physics lists, and output formats. All of these features are available as class libraries that are typically compiled into a single executable. The user selects the particular experimental setup implementation at run-time via macros. The combination of all these common classes into one framework reduces duplication of efforts, eases comparison between simulated data and experiment, and simplifies the addition of new detectors to be simulated. This paper focuses on the software framework, custom event generators, and physics list.

97 MATHEMATICS AND COMPUTING↗

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter↗

The development of non destructive remote measurement method of concrete contamination

In the frame of the decommissioning of nuclear power plants or laboratories, the penetration depth of the contamination in concrete surfaces: walls, floor, is unknown. Its knowledge requires sample analysis, that is time consuming and expensive. The main goal of the work is to define and evaluate a non-destructive measurement technique for the evaluation of the contamination depth in concrete. Estimation of accuracy of measurements for different contamination levels, time of measurement, value of natural radionuclides (NRN) concentration in concrete and background radiation dose were carried out. The type of relevant detector depends of selected limiting sensitivity, the weight and sizes of the device. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

EBL effect on the observation of multi-TeV flaring of 2009 from Markarian 501

Markarian 501 is a high-peaked BL Lacertae object and has undergone many major outbursts since its discovery in 1996. As a part of the multiwavelength campaign, in the year 2009 this blazar was observed for 4.5 months from March 9 to August 1 and during the period April 17 to May 5 it was observed by both space and ground based observatories covering the entire electromagnetic spectrum. A very strong high energy γ-ray flare was observed on May 1 by Whipple telescope in the energy range 317 GeV to 5 TeV and the flux was about 10 times higher than the average baseline flux. Previously during 1997 Markarian 501 had undergone another long outburst, which was observed by HEGRA telescopes and the energy spectrum was well beyond 10 TeV. The photohadronic model complemented by the extragalactic background radiation (EBL) correction fits well with the flares data observed by both Whipple and HEGRA. Our model predicts a steeper slope of the energy spectrum beyond 10 TeV, which is compatible with the improved analysis of the HEGRA data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Identification of Low-level Point Radioactive Sources using a sensor network

Identification of a low-level point radioactive source amidst background radiation is achieved by a network of radiation sensors using a two-step approach. Based on measurements from three or more sensors, a geometric difference triangulation method or an N-sensor localization method is used to estimate the location and strength of the source. Then a sequential probability ratio test based on current measurements and estimated parameters is employed to finally decide: (1) the presence of a source with the estimated parameters, or (2) the absence of the source, or (3) the insufficiency of measurements to make a decision. This method achieves specified levels of false alarm and missed detection probabilities, while ensuring a close-to-minimal number of measurements for reaching a decision. This method minimizes the ghost-source problem of current estimation methods, and achieves a lower false alarm rate compared with current detection methods. This method is tested and demonstrated using: (1) simulations, and (2) a test-bed that utilizes the scaling properties of point radioactive sources to emulate high intensity ones that cannot be easily and safely handled in laboratory experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗