An interpretation of Jupiter's decametric radiation and the terrestrial kilometric radiation as direct amplified gyroemission

Direct amplified gyroemission due to an anisotropic distribution of suprathermal electrons is proposed as the most plausible emission mechanism for Jupiter's decametric radiation (DAM) and the terrestrial auroral kilometric radiation (AKR). It is suggested that the required electron distribution could be produced by electrons, initially with small pitch angles, precipitating from the magnetosphere. A quasi-linear treatment of the proposed mechanism is outlined, including satisfaction of the Doppler condition, calculation of the growth rate, conditions for quasi-linear relaxation, and generation of the anisotropy. The mechanism is applied to the Jovian DAM, emphasizing the growth rate, the power radiated, and the elliptical polarization of the radiation. It is found that the theory can account for the gross features of the DAM, provided the number density in the precipitating electron streams exceeds 20 per cu cm. Application of the theory to the AKR shows that the requirements concerning the properties of the precipitating electrons appear to be satisfied by the observed properties of those inverted V events which correlate with the emission of AKR.

Melrose, D. B.↗

Bidirectional Amplifier

Two-stage transformer-coupled device amplifies incoming and outgoing signals of different frequencies being propagated in both directions along single line.

Holley, L. D.↗

Radiographic amplifier screens: Fabrication process and characteristics

The fabrication process and transfer characteristics for solid state radiographic image transducers (radiographic amplifier screens) is described. These screens were developed for use in real time nondestructive evaluation procedures that require large format radiographic images with contrast and resolution capabilities unavailable with conventional fluoroscopic screens. This work was directed toward screens usable for inmotion, on-line radiographic inspection by means of closed circuit television.

Szepesi, Z. P.↗

Amplifying ribbon extensometer

A self-contained, nonelectrical strain gage capable of amplifying strain inputs and preserving the maximum strain measurement for later observance is presented.

Alley, V. L., Jr.↗

Compound hydraulic shear-modulated vortex amplifiers

A novel two-stage shear-modulated hydraulic vortex amplifier (U.S. patent 3,520,317) has been fabricated and put through preliminary steady-state testing at the 1000 psi supply pressure level with flows up to 15 gpm. The invention comprises a conventional fluidic vortex power stage and a shear-modulated pilot stage. In the absence of any mechanical moving parts, water may be used as the hydraulic medium thus opening the way to many underseas applications. At blocked load, a control input from 0 to 150 psi was required to achieve an output from 0 to 900 psi; at wide-open load, a control input of 0 to 120 psi was needed to achieve an output from 0 to 15 gpm. The power stage has been found unsuitable for the proportional control mode because of its nonlinear performance in the intermediate load range and because of strong pressure fluctuations (plus or minus 150 psi) in the intermediate control range. The addition of the shear-modulated pilot stage improves intermediate load linearity.

Goldschmied, F. R.↗

Fabrication and characteristics of experimental radiographic amplifier screens

The fabrication process and transfer characteristics for solid state radiographic image transducers (radiographic amplifier screens) are described. These screens are for use in realtime nondestructive evaluation procedures that require large format radiographic images with contrast and resolution capabilities unavailable with conventional fluoroscopic screens. The screens are suitable for in-motion, on-line radiographic inspection by means of closed circuit television. Experimental effort was made to improve image quality and response to low energy (5 kV and up) X-rays.

Szepesi, Z.↗

Analysis and design of optically pumped far infrared oscillators and amplifiers

A waveguide laser oscillator was designed and experimental measurements made of relationships among output power, pressure, pump power, pump frequency, cavity tuning, output beam pattern, and cavity mirror properties for various active gases. A waveguide regenerative amplifier was designed and gain measurements were made for various active gases. An external Fabry-Perot interferometer was fabricated and used for accurate wavelength determination and for measurements of the refractive indices of solids transparent in the far infrared. An electronic system was designed and constructed to provide an appropriate error signal for use in feedback control of pump frequency. Pump feedback from the FIR laser was decoupled using a vibrating mirror to phase modulate the pump signal.

Galantowicz, T. A.↗

Low-common-mode differential amplifier

Outputs of differential amplifier are excellently matched in phase and amplitude over wide range of frequencies. Common mode feedback loop offsets differences between two signal paths. Possible applications of circuit are in oscilloscopes, integrated circuit logic tester, and other self contained instruments.

Morrison, S.↗

Stable S-band power amplifier

Relatively linear amplifier with automatic level control (ALC) preserves modulation characteristics of phase-shift-key (PSK) moculated S-band transmitter.

Hermesmeyer, C. E.↗

Limiting amplifier for microwaves

Limiting amplifier, using gallium arsenide field effect transistor (FET), delivers constant-amplitude drive signal to KU-band traveling wave tube (TWT) thus preventing distortion in output from TWT.

Owens, J. N.↗

Rise-time control in saturated amplifiers

Inductor in transistor emitter circuit controls output rise time of saturated amplifier thereby reducing radiated noise and distortion in subsequent circuits. Device also improves current balancing in push/pull transformer circuits. Resulting circuits are self compensating for temperature.

Theall, C. E.↗

Gyrotron: A high-frequency microwave amplifier

A proposed microwave amplifier mechanism for future generations of millimeter high power uplinks to spacecraft and planetary radar transmitters is introduced. Basic electron-electromagnetic field interaction theory for RF power gain is explained. The starting point for general analytical methods leading to detailed design results is presented.

Kupiszewski, A.↗

Analytical investigation of efficiency and performance limits in klystron amplifiers using multidimensional computer programs; multi-stage depressed collectors; and thermionic cathode life studies

An extensive parametric investigation was performed of the extraction of energy in output gaps of klystron amplifiers, using 3-D computer programs. Due to complexity of the program which used a hydrodynamic, axially and radially deformable disk ring model and the resulting long computing time, the investigation was limited to the output gap, by far the most important and difficult part of the klystron interaction. Results show that, for a confined flow focused beam throughout the penultimate cavity, radial velocities remain very small and the beam is highly laminar. It was, therefore, concluded that possible errors resulting from treating only the output cavity in 3-D would remain small.

Kosmahl, H. G.↗

A four-way distribution amplifier for reference signal distribution

A four way distribution amplifier with up to 100 dB isolation and with low phase noise of -140 dBc in a 1 Hz bandwidth 10 Hz from a 100 MHz signal was developed. It is to be used in the stabilized optical fiber distribution system to provide multiple outputs.

Lo, Y. V.↗

Low current linearization of magnetic amplifier for dc transducer

A magnetic amplifier having two saturable reactor cores with a separate excitation winding on each connected in series opposition, a common control winding, and a common output winding, is adapted for use as a low level signal transducer. The separate excitation windings are excited in push-pull mode through a center tapped transformer, and at least one diode is included in series with a load resistor connected to the output winding. A resistor in series with the output winding and load resistor is connected between the center tap of the excitation transformer and the connection between the two excitation windings of the saturable cores. This series resistor provides a return current path for the output winding and allows the excitation windings of the saturable cores to operate as primary windings of transformers.

Nagano, S.↗