Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Advanced Transportation System Studies. Technical Area 3: Alternate Propulsion Subsystems Concepts: Program Cost Estimates - Volume 3

The objective of this contract was to provide definition of alternate propulsion systems for both earth-to-orbit (ETO) and in-space vehicles (upper stages and space transfer vehicles). For such propulsion systems, technical data to describe performance, weight, dimensions, etc. was provided along with programmatic information such as cost, schedule, needed facilities, etc. Advanced technology and advanced development needs were determined and provided. This volume separately presents the various program cost estimates that were generated under three tasks: the F- IA Restart Task, the J-2S Restart Task, and the SSME Upper Stage Use Task. The conclusions, technical results , and the program cost estimates are described in more detail in Volume I - Executive Summary and in individual Final Task Reports.

Levack, Daniel J. H.↗

Dose-Volume Analysis of Predictors for Gastrointestinal Toxicity After Concurrent Full-Dose Gemcitabine and Radiotherapy for Locally Advanced Pancreatic Adenocarcinoma

Purpose: To identify dosimetric predictors for the development of gastrointestinal (GI) toxicity in patients with locally advanced pancreatic adenocarcinoma (LAPC) treated with concurrent full-dose gemcitabine and radiotherapy (GemRT). Methods and Materials: From June 2002 to June 2009, 46 LAPC patients treated with definitive GemRT were retrospectively analyzed. The stomach and duodenum were retrospectively contoured separately to determine their dose-volume histogram (DVH) parameters. GI toxicity was defined as Grade 3 or higher GI toxicity. The follow-up time was calculated from the start of RT to the date of death or last contact. Univariate analysis (UVA) and multivariate analysis (MVA) using Kaplan-Meier and Cox regression models were performed to identify risk factors associated with GI toxicity. The receiver operating characteristic curve and the area under the receiver operating characteristic curve (AUC) were used to determine the best DVH parameter to predict for GI toxicity. Results: Of the patients, 28 (61%) received concurrent gemcitabine alone, and 18 (39%) had concurrent gemcitabine with daily erlotinib. On UVA, only the V{sub 20Gy} to V{sub 35Gy} of duodenum were significantly associated with GI toxicity (all p {<=} 0.05). On MVA, the V{sub 25Gy} of duodenum and the use of erlotinib were independent risk factors for GI toxicity (p = 0.006 and 0.02, respectively). For the entire cohort, the V{sub 25Gy} of duodenum is the best predictor for GI toxicity (AUC = 0.717), and the 12-month GI toxicity rate was 8% vs. 48% for V{sub 25Gy} {<=} 45% and V{sub 25Gy} > 45%, respectively (p = 0.03). However, excluding the erlotinib group, the V{sub 35Gy} is the best predictor (AUC = 0.725), and the 12-month GI toxicity rate was 0% vs. 41% for V{sub 35Gy} {<=} 20% and V{sub 35Gy} > 20%, respectively (p = 0.04). Conclusions: DVH parameters of duodenum may predict Grade 3 GI toxicity after GemRT for LAPC. Concurrent use of erlotinib during GemRT may increase GI toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic recombination rate determination through heat-transfer measurement.

A theoretical and experimental demonstration is presented which shows that under suitable conditions the volume recombination coefficient can be determined by measuring the heat transfer rate into the wall of a cylinder through which a dissociated stream is passing. The experimental results obtained are in agreement with those of other investigators.

Park, C.↗

The correlation function of flux-limited X-ray clusters

We show that the spatial correlation function of a flux-limited sample of X-ray-selected clusters of galaxies will exhibit a correlation scale that is smaller than the correlation scale of a volume-limited, richness-limited sample of comparable apparent spatial density. The flux-limited sample contains clusters of different richnesses at different distances: poor groups are found nearby and rich clusters at greater distances. Since the cluster correlation strength is known to increase with richness, the flux-limited sample averages over the correlations of poor and rich clusters. On the other hand, a volume-limited, richness-limited sample has a minimum richness threshold, and a constant mixture of richnesses with redshift. Using the observed correlation scale for rich (R greater than or equal to 1) clusters, r(sub 0)(R greater than or equal to 1) = 21 +/- 2 Mpc/h, that was determined from previous volume-limited studies, we derive for the Roentgen Satellite (ROSAT) flux-limited X-ray cluster sample r(sub 0) (flux-limited) approximately equals 14 Mpc/h, in agreement with the recently observed value of 13.7 +/- 2.3 Mpc/h.

Bahcall, Neta A.↗

Effects of pressure- or volume-overload hypertrophy on passive stiffness in isolated adult cardiac muscle cells

It has been hypothesized that the changes in myocardial stiffness induced by chronic hemodynamic overloading are dependent on changes in the passive stiffness of the cardiac muscle cell (cardiocyte). However, no previous studies have examined the passive constitutive properties of cardiocytes isolated from animals with myocardial hypertrophy. Accordingly, changes in relative passive stiffness of cardiocytes isolated from animals with chronic pressure- or volume-overload hypertrophy were determined by examining the effects of anisosmotic stress on cardiocyte size. Anisosmotic stress was produced by altering superfusate osmolarity. Hypertrophied cardiocytes were enzymatically isolated from 16 adult cats with right ventricular (RV) pressure-overload hypertrophy induced by pulmonary artery banding (PAB) and from 6 adult cats with RV volume-overload hypertrophy induced by creating an atrial septal defect (ASD). Left ventricular (LV) cardiocytes from each cat served as nonhypertrophied, normally loaded, same-animal controls. Superfusate osmolarity was decreased from 305 +/- 3 to 135 +/- 5 mosM and increased to 645 +/- 4 mosM. During anisosmotic stress, there were no significant differences between hypertrophied RV and normal LV cardiocytes in pressure overload PAB cats with respect to percent change in cardiocyte area (47 +/- 2% in RV vs. 48 +/- 2% in LV), diameter (46 +/- 3% in RV vs. 48 +/- 2% in LV), or length (2.4 +/- 0.2% in RV vs. 2.0 +/- 0.3% in LV), or sarcomere length (1.5 +/- 0.1% in RV vs. 1.3 +/- 0.3% in LV). Likewise, there were no significant differences in cardiocyte strain between hypertrophied RV and normal LV cardiocytes from ASD cats. In conclusion, chronic pressure-overload hypertrophy and chronic volume-overload hypertrophy did not alter the cardiocyte response to anisosmotic stress. Thus chronic overload hypertrophy did not alter relative passive cardiocyte stiffness.

Non-NASA Center↗

MPCV Exercise Operational Volume Analysis

In order to minimize the loss of bone and muscle mass during spaceflight, the Multi-purpose Crew Vehicle (MPCV) will include an exercise device and enough free space within the cabin for astronauts to use the device effectively. The NASA Digital Astronaut Project (DAP) has been tasked with using computational modeling to aid in determining whether or not the available operational volume is sufficient for in-flight exercise.Motion capture data was acquired using a 12-camera Smart DX system (BTS Bioengineering, Brooklyn, NY), while exercisers performed 9 resistive exercises without volume restrictions in a 1g environment. Data were collected from two male subjects, one being in the 99th percentile of height and the other in the 50th percentile of height, using between 25 and 60 motion capture markers. Motion capture data was also recorded as a third subject, also near the 50th percentile in height, performed aerobic rowing during a parabolic flight. A motion capture system and algorithms developed previously and presented at last years HRP-IWS were utilized to collect and process the data from the parabolic flight [1]. These motions were applied to a scaled version of a biomechanical model within the biomechanical modeling software OpenSim [2], and the volume sweeps of the motions were visually assessed against an imported CAD model of the operational volume. Further numerical analysis was performed using Matlab (Mathworks, Natick, MA) and the OpenSim API. This analysis determined the location of every marker in space over the duration of the exercise motion, and the distance of each marker to the nearest surface of the volume. Containment of the exercise motions within the operational volume was determined on a per-exercise and per-subject basis. The orientation of the exerciser and the angle of the footplate were two important factors upon which containment was dependent. Regions where the exercise motion exceeds the bounds of the operational volume have been identified by determining which markers from the motion capture exceed the operational volume and by how much. A credibility assessment of this analysis was performed in accordance with NASA-STD-7009 prior to delivery to the MPCV program.

mathematical models↗

Power system disturbance localization using recurrence quantification analysis and minimum-volume-enclosing ellipsoid

A method for determining a location of a disturbance in a power system is provided. The method includes receiving data from a plurality of sensors distributed across the power system; performing a recurrence quantification analysis on the received data to identify a predetermined number of sensors, from the plurality of sensors, that are closest to the disturbance; constructing a plurality of minimum-volume-enclosing ellipsoids based on and enclosing the data received from the identified sensors; extracting one or more parameters from the plurality of minimum-volume-enclosing ellipsoids; inputting the one or more parameters into a multivariate-random-forest regression algorithm to determine the location of the disturbance and a power mismatch corresponding to the disturbance; and presenting, on one or more display units, the determined location of the disturbance and the determined power mismatch.

Cui, Yi↗

Optimal carbon capture and storage contracts using historical CO 2 emissions levels

In an effort to reduce carbon dioxide (CO 2 ) emissions to the atmosphere, carbon capture and storage (CCS) technology has been developed to collect CO 2 from emissions generators and store it underground. Recent proposed legislation would limit the volume of emissions generated from power sources, effectively requiring some sources to participate in CCS. Both emissions sources and storage operators require incentives to enter into contracts to capture excess emissions at the source, and transport and store the CO 2 underground. As the level of emissions from power plants is stochastic and carryover into future time periods is expensive, we develop a newsvendor model to determine the optimal price and volume of these contracts to maximize the expected profit of the storage operator and encourage the participation of multiple emissions sources. Because the storage operator has a limit on the amount of CO 2 that can be injected each month, this limit affects the allocation of the optimal contract amounts between the emitters. Furthermore, the distribution of emissions and relative costs of transportation also influence the optimal policy. In addition to analytical solutions, we present data-driven methods for using correlated emissions data to determine the optimal price and volume of these contracts.

42 ENGINEERING↗

Development of a beam ion velocity detector for the heavy ion beam probe

In an axisymmetric plasma, the conservation of canonical angular momentum constrains heavy ion beam probe (HIBP) trajectories such that measurement of the toroidal velocity component of secondary ions provides a localized determination of the poloidal flux at the volume where they originated. We have developed a prototype detector which is designed to determine the beam angle in one dimension through the detection of ion current landing on two parallel planes of detecting elements. A set of apertures creates a pattern of ion current on wires in the first plane and solid metal plates behind them; the relative amounts detected by the wires and plates determine the angle which beam ions enter the detector, which is used to infer the toroidal velocity component. The design evolved from a series of simulations within which we modeled ion beam velocity changes due to equilibrium and fluctuating magnetic fields, along with the ion beam profile and velocity dispersion, and studied how these and characteristics such as the size, cross section, and spacing of the detector elements affect performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation

The aim of this study is to evaluate the impact of the patient dose due to the kilovoltage cone beam computed tomography (kV-CBCT) in a prostate intensity-modulated radiation therapy (IMRT). The dose distributions for the five prostate IMRTs were calculated using the Pinnacle3 treatment planning system. To calculate the patient dose from CBCT, phase-space beams of a CBCT head based on the ELEKTA x-ray volume imaging system were generated using the Monte Carlo BEAMnrc code for 100, 120, 130, and 140 kVp energies. An in-house graphical user interface called DOSCTP (DOSXYZnrc-based) developed using MATLAB was used to calculate the dose distributions due to a 360 deg. photon arc from the CBCT beam with the same patient CT image sets as used in Pinnacle3. The two calculated dose distributions were added together by setting the CBCT doses equal to 1%, 1.5%, 2%, and 2.5% of the prescription dose of the prostate IMRT. The prostate plan and the summed dose distributions were then processed in the CERR platform to determine the dose-volume histograms (DVHs) of the regions of interest. Moreover, dose profiles along the x- and y-axes crossing the isocenter with and without addition of the CBCT dose were determined. It was found that the added doses due to CBCT are most significant at the femur heads. Higher doses were found at the bones for a relatively low energy CBCT beam such as 100 kVp. Apart from the bones, the CBCT dose was observed to be most concentrated on the anterior and posterior side of the patient anatomy. Analysis of the DVHs for the prostate and other critical tissues showed that they vary only slightly with the added CBCT dose at different beam energies. On the other hand, the changes of the DVHs for the femur heads due to the CBCT dose and beam energy were more significant than those of rectal and bladder wall. By analyzing the vertical and horizontal dose profiles crossing the femur heads and isocenter, with and without the CBCT dose equal to 2% of the prescribed dose, it was found that there is about a 5% increase of dose at the femur head. Still, such an increase in the femur head dose is well below the dose limit of the bone in our IMRT plans. Therefore, under these dose fractionation conditions, it is concluded that, though CBCT causes a higher dose deposited at the bones, there may be no significant effect in the DVHs of critical tissues in the prostate IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factors Impacting Habitable Volume Requirements: Results from the 2011 Habitable Volume Workshop

This report documents the results of the Habitable Volume Workshop held April 18-21, 2011 in Houston, TX at the Center for Advanced Space Studies-Universities Space Research Association. The workshop was convened by NASA to examine the factors that feed into understanding minimum habitable volume requirements for long duration space missions. While there have been confinement studies and analogs that have provided the basis for the guidance found in current habitability standards, determining the adequacy of the volume for future long duration exploration missions is a more complicated endeavor. It was determined that an improved understanding of the relationship between behavioral and psychosocial stressors, available habitable and net habitable volume, and interior layouts was needed to judge the adequacy of long duration habitat designs. The workshop brought together a multi-disciplinary group of experts from the medical and behavioral sciences, spaceflight, human habitability disciplines and design professionals. These subject matter experts identified the most salient design-related stressors anticipated for a long duration exploration mission. The selected stressors were based on scientific evidence, as well as personal experiences from spaceflight and analogs. They were organized into eight major categories: allocation of space; workspace; general and individual control of environment; sensory deprivation; social monotony; crew composition; physical and medical issues; and contingency readiness. Mitigation strategies for the identified stressors and their subsequent impact to habitat design were identified. Recommendations for future research to address the stressors and mitigating design impacts are presented.

Simon, M.↗

Cloud Microphysics in Hurricane Outflows: Observations in 'Bonnie' (1998) at 12 km Altitude

The water balance of a hurricane is controlled by boundary layer inflow, near vertical motion in the eyewall causing coalescence precipitation at above and residual ice precipitation at below freezing temperatures, and cirrus outflow at below -40 C aloft. In this paper we address the question of efficiency of water removal by this cirrus outflow which is important for the release of latent heat at high altitudes and its role in the dynamic flow at that level. During NASA's 1998 Convection and Moisture Experiment campaign we acquired microphysical outflow data in order to (1) determine the release and redistribution of latent heat near the top of hurricanes, (2) aid in TRMM algorithm development for remote sensing of precipitation, and (3) determine the optical/radiative characteristics of hurricane outflow. The data were acquired with Particle Measuring Systems two dimensional imaging spectrometers. On 23 August and again during the hurricane's landfall on 26 August, 1998, the NASA DC-8 aircraft penetrated hurricane 'Bonnie' four times each near 200 hPa pressure altitude. The eye crossing times were determined by (1) zero counts of cloud particles, (2) approximately 5 C increases in static and potential temperatures, and (3) minima in speeds and changes of direction of horizontal winds. The vertical winds showed shear between -6 m per second and +4 m per second and tangential winds approached 30 m per second in the eyewall. The particle volumes in the eyewall (determined by the pixels the particles shadowed in the direction of flight [x-direction] and normally to it by the number of diodes that they shadowed [y-direction]) ranged between 0.5 and 5.0 cubic centimeters per cubic meter. With a particle density near 0.2 g per cubic centimeter (determined from in situ melting and evaporation on a surface collector), the 1.0 g per meter corresponding mass of cloud ice ranged between 0.27 and 2.7 g per kilograms yielding horizontal fluxes between 8.1 and 81 g per square meters per second. The outflow ice was concentrated in crystals of a modal size of 190 micrometers. The particle size distributions were heavily skewed toward sizes with 98% of all cirrus particles smaller than the modal size comprising, however, only 20% of the mass. Thus the smaller than modal size particles dominantly affected the optical/radiative characteristics of the cloud, whereas the larger than modal size crystals determined the ice mass, hence dominated latent heating. Questions to be addressed relate to the origin of individual ice particles as the hurricane evolved and the likelihood of pristine and aggregate particle formation under the complicated conditions of rotation and outflow in the eyewall.

Pueschel, Rudolf F.↗

Mechanisms of boron fiber strengthening by thermal treatment

The fracture strain for boron on tungsten fibers can be improved by heat treatment under vacuum or argon environments. The mechanical basis for this improvement is thermally-induced axial contraction of the entire fiber, whereby strength-controlling core flaws are compressed and fiber fracture strain increased by the value of the contraction strain. By highly sensitive measurements of fiber density and volume, the physical mechanisms responsible for contraction under both environments was identified as boron atom diffusion out of the fiber sheath. The fiber contracts because the average volume of the resulting microvoid was determined to be only 0.26 + or - 0.09 the average atomic volume of the removed atom. The basic and practical implications of these results are discussed with particular emphasis on the theory, use, and limitations of heat-induced contraction as a simple cost-effective secondary processing method.

Dicarlo, J. A.↗

Non-invasive method and apparatus for monitoring intracranial pressure and pressure volume index in humans

Non-invasive measuring devices responsive to changes in a patient's intracranial pressure (ICP) can be accurately calibrated for monitoring purposes by providing known changes in ICP by non-invasive methods, such as placing the patient on a tilting bed and calculating a change in ICP from the tilt angle and the length of the patient's cerebrospinal column, or by placing a pressurized skull cap on the patient and measuring the inflation pressure. Absolute values for the patient's pressure-volume index (PVI) and the steady state ICP can then be determined by inducing two known changes in the volume of cerebrospinal fluid while recording the corresponding changes in ICP by means of the calibrated measuring device. The two pairs of data for pressure change and volume change are entered into an equation developed from an equation describing the relationship between ICP and cerebrospinal fluid volume. PVI and steady state ICP are then determined by solving the equation. Methods for inducing known changes in cerebrospinal fluid volume are described.

Cantrell, John H.↗

Non-invasive method and apparatus for monitoring intracranial pressure and pressure volume index in humans

Non-invasive measuring devices responsive to changes in a patient's intracranial pressure (ICP) can be accurately calibrated for monitoring purposes by providing known changes in ICP by non-invasive methods, such as placing the patient on a tilting bed and calculating a change in ICP from the tilt angle and the length of the patient's cerebrospinal column, or by placing a pressurized skull cap on the patient and measuring the inflation pressure. Absolute values for the patient's pressure-volume index (PVI) and the steady state ICP can then be determined by inducing two known changes in the volume of cerebrospinal fluid while recording the corresponding changes in ICP by means of the calibrated measuring device. The two pairs of data for pressure change and volume change are entered into an equation developed from an equation describing the relationship between ICP and cerebrospinal fluid volume. PVI and steady state ICP are then determined by solving the equation. Methods for inducing known changes in cerebrospinal fluid volume are described.

Yost, William T.↗

Experimental investigation of multi-scale strain-field heterogeneity in rocks

Rocks have inherently heterogeneous micro-structures. The mechanical response of these heterogeneous micro-structures primarily governs the overall macroscopic behavior of intact rocks, as these features cause heterogeneity in the distribution of stress and strain within a rock volume. These attributes have generally been studied through numerical tools, but in this study, the stress-induced multi-scale spatial heterogeneity in the strain-field of three types of rocks was analyzed experimentally. The full-field non-contact strain measurement approach of 2D Digital Image Correlation (DIC) was employed for real-time evaluation of the progression of strain-field heterogeneity across the surface of the rock specimens when subjected to uniaxial compression. The results show that the strain-field heterogeneity is a characteristic of the inherent heterogeneity of the rock specimens, and that it amplifies with the magnitude of stress applied on the rock specimens. The changes in the strain-field heterogeneity with loading were consistent with established microcrack evolution processes in the rock specimens. The statistical fluctuation in the strain-field heterogeneity of the three rocks at varying gauge lengths (GL) was then analyzed for the determination of the Representative Volume Element (RVE) length-scale at increasing load levels. The evolution of the RVE length-scale with loading facilitates an objective way of determination of the stress at which the strain-field heterogeneity increases and begins to influence the overall global response of the material. The RVE length-scale variation with loading showed that at the RVE length-scale reaches the specimen-scale at load levels well below the peak strength.

2D-digital image correlation↗

A new theory of simple classical fluids

The paper presents a unified structural and thermodynamic theory of simple classical fluids in which the interactions between the particles can be represented by spherically symmetric pairwise potentials. Both the excess entropy and the gross features of the radial distribution function are determined mainly by excluded volume effects, which are in turn governed by a hard-core property intrinsic to any pair potential. The potential beyond this effective hard core is considered relatively weak and can be treated as a perturbation. It is also considered essential to sum all subclasses of diagrams to infinite order. The basic form of a diagrammatic scheme which allows both summation and the determination of the structure and excess entropy is presented, and a statement of universality is derived. The statement has been confirmed within the accuracy of present-day computer simulations, and a possible procedure for calculating both the structure and thermodynamics of every physically conceivable pair potential is presented.

Rosenfeld, Y.↗

A study to determine the flight characteristics and handling qualities of variable geometry spacecraft. Volume 2: Medium L/D concept with switch-blade wings

Flight characteristics and wing deployment transients for a variable geometry logistics spacecraft concept having a hypersonic lift-drag ratio near 2.0, and employing switch-blade wings for deployment at high subsonic speeds have been determined. These characteristics are based on detailed static wind tunnel results and estimated weight and inertial characteristics of a 9-man logistics lifting entry vehicle. In all instances, unpowered flight is assumed. The present volume is the second of a four volume series encompassing hypersonic lift-drag ratio vehicles from 1 to 3, and including several forms of deployable lifting surfaces. For Volumes 1 and 3, see N70-25699 and N72-15779 respectively.

Kuchta, B. J.↗