Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “variable conductance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Differential Organic Carbon Mineralization Responses to Soil Moisture in Three Different Soil Orders Under Mixed Forested System

Soil microbial respiration is one of the largest sources of carbon (C) emissions to the atmosphere in terrestrial ecosystems, which is strongly dependent on multiple environmental variables including soil moisture. Soil moisture content is strongly dependent on soil texture, and the combined effects of texture and moisture on microbial respiration are complex and less explored. Therefore, this study examines the effects of soil moisture on the mineralization of soil organic C Soil organic carbon in three different soils, Ultisol, Alfisol and Vertisol, collected from mixed forests of Georgia, Missouri, and Texas, United States , respectively. A laboratory microcosm experiment was conducted for 90 days under different moisture regimes. Soil respiration was measured weekly, and destructive harvests were conducted at 1, 15, 60, and 90 days after incubation to determine extractable organic C (EOC), phospholipid fatty acid based microbial community, and C-acquiring hydrolytic extracellular enzyme activities (EEA). The highest cumulative respiration in Ultisol was observed at 50% water holding capacity (WHC), in Alfisol at 100% water holding capacity, and in Vertisol at 175% WHC. The trends in Extractable Organic Carbon were opposite to that of cumulative microbial respiration as the moisture levels showing the highest respiration showed the lowest EOC concentration in all soil types. Also, extracellular enzyme activities increased with increase in soil moisture in all soils, however, respiration and EEA showed a decoupled relationship in Ultisol and Alfisol soils. Soil moisture differences did not influence microbial community composition.

54 ENVIRONMENTAL SCIENCES↗

Polarization and variability of compact sources measured in Planck time-ordered data

This paper introduces a new Planck Catalog of Polarized and Variable Compact Sources (PCCS-PV) comprising 153 sources, the majority of which are extragalactic. The data include both the total flux density and linear polarization measured by Planck with frequency coverage from 30 to 353 GHz, and temporal spacing ranging from days to years. We classify most sources as beamed, extragalactic radio sources; the catalog also includes several radio galaxies, Seyfert galaxies, and Galactic and Magellanic Cloud sources, including H II regions and planetary nebulae. An advanced extraction method applied directly to the multifrequency Planck time-ordered data, rather than the mission sky maps, was developed to allow an assessment of the variability of polarized sources. Our analysis of the time-ordered data from the Planck mission, tod2flux, allowed us to catalog the time-varying emission and polarization properties for these sources at the full range of polarized frequencies employed by Planck, 30-353 GHz. PCCS-PV provides the time-and frequency-dependent, polarized flux densities for all 153 sources. To illustrate some potential applications of the PCCS-PV, we conducted preliminary comparisons of our measurements of selected sources with published data from other astronomical instruments. In summary, we find general agreement between the Planck and the Institut de Radioastronomie Millimétrique (IRAM) polarization measurements as well as with the Metsähovi 37 GHz values at closely similar epochs. Here, these combined measurements also show the value of PCCS-PV results and the PCCS2 catalog for filling in missing spectral (or temporal) coverage and helping to define the spectral energy distributions of extragalactic sources. In turn, these results provide useful clues as to the physical properties of the sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Discovering vanishing objects in POSS I red images using the Virtual Observatory

ABSTRACT In this paper, we report a search for vanishing sources in POSS I red images using virtual observatory (VO) archives, tools, and services. The search, conducted in the framework of the VASCO project, aims at finding POSS I (red) sources not present in recent catalogues like Pan-STARRS DR2 (limiting magnitude r = 21.4) or Gaia EDR3 (limiting magnitude G = 21). We found 298 165 sources visible only in POSS I plates, out of which 288 770 had a cross-match within 5 arcsec in other archives (mainly in the infrared), 189 were classified as asteroids, 35 as variable objects, 3592 as artefacts from the comparison to a second digitization (Supercosmos), and 180 as high proper motion objects without information on proper motion in Gaia EDR3. The remaining unidentified transients (5399) as well as the 172 163 sources not detected in the optical but identified in the infrared regime are available from a VO compliant archive and can be of interest in searches for strong M-dwarf flares, high-redshift supernovae, asteroids, or other categories of unidentified red transients. No point sources were detected by both POSS-I and POSS-II before vanishing, setting the rate of failed supernovae in the Milky Way during 70 yr to less than one in one billion.

Solano, Enrique↗

Time-series machine-learning error models for approximate solutions to parameterized dynamical systems

This work proposes a machine-learning framework for modeling the error incurred by approximate solutions to parameterized dynamical systems. In particular, we extend the machine-learning error models (MLEM) framework proposed in Ref. Freno and Carlberg (2019) to dynamical systems. The proposed Time-Series Machine-Learning Error Modeling (T-MLEM) method constructs a regression model that maps features – which comprise error indicators that are derived from standard a posteriori error-quantification techniques – to a random variable for the approximate-solution error at each time instance. The proposed framework considers a wide range of candidate features, regression methods, and additive noise models. We consider primarily recursive regression techniques developed for time-series modeling, including both classical time-series models (e.g., autoregressive models) and recurrent neural networks (RNNs), but also analyze standard non-recursive regression techniques (e.g., feed-forward neural networks) for comparative purposes. Finally, numerical experiments conducted on multiple benchmark problems illustrate that the long short-term memory (LSTM) neural network, which is a type of RNN, outperforms other methods and yields substantial improvements in error predictions over traditional approaches.

42 ENGINEERING↗

Effects of ambient temperature on electric vehicle range considering battery Performance, powertrain Efficiency, and HVAC load

Here, this study investigates the impact of ambient temperature on the range of electric vehicles (EVs) by analyzing its effects on usable battery energy (UBE), heating, ventilation, and air conditioning (HVAC) energy consumption, and powertrain energy losses. Chassis dynamometer tests within a thermal chamber were conducted under various temperature conditions to investigate these impacts. The results indicate that lower temperatures lead to a decrease in UBE for lithium-ion batteries in EVs. At −18 °C, the UBE exhibited reductions of 4---8 % compared to the UBE at 22 °C. Battery thermal management strategies significantly affected the UBE loss, with different strategies resulting in distinct UBE reductions. HVAC energy consumption, especially for interior heating, proved to be the most dominant variable affecting EV driving range. Larger discrepancies between the HVAC target temperature (22 °C) and the ambient temperature increased HVAC energy usage. The type of HVAC system also influenced energy consumption, where EVs equipped with heat pumps demonstrated lower energy consumption for heating compared to those relying solely on resistance heaters. Ambient temperature also influenced motor energy consumption due to increased frictions, powertrain losses and tire rolling resistance at lower temperatures; consequently, regenerative braking energy decreased in cold conditions. Combining these effects influenced the overall energy consumption and driving range of EVs. At −18 °C, the driving range saw a substantial decrease of up to 60 % compared to 22 °C, while a slight decrease was observed at 35 °C.

Ambient Temperature↗

2000-2001 California Statewide Household Travel Survey

The 2000-2001 California Statewide Household Travel Survey, conducted under the auspices of the California Department of Transportation, was conducted between October 2000 and December 2001 among households located in each of California's 58 counties. The purpose of the study was to update the statewide database of household socioeconomic and travel information and helped to refine travel estimates, models, and forecasts throughout California. The survey was an essential element in determining statewide and regional travel patterns. A total of 17,040 households participated in the survey, contributing household socioeconomic and travel data. Travel variables collected include trip times, mode, activity at location, origin and destination, and vehicle occupancy, among other travel-related data from 134,173 trips. Residents completed diary records of their daily travel over a 24-hour (weekday) or 48-hour period (Friday/Saturday or Sunday/Monday pair).

1Hz data↗

Birefringent Color Filter by Layered Metal‐Organic Chalcogenides: In‐Plane Anisotropy and Odd/Even Effect

Anisotropic 2D materials are gaining interest recently as building blocks for angular‐dependent optical/electrical devices. However, the fundamental understanding of their structure‐property‐relationship is limited, which hinders further modulation of their unique characteristics via structure tailoring. Here the in‐plane structural anisotropy and the tunable optical/electrical properties of a series of radiation‐sensitive (X‐ray, e‐beam) metal‐organic chalcogenide (MOC) single crystals are comprehensively revealed with ligands of variable length/parity. Their monoclinic crystallography is determined at atomic resolution by a simple method that couples X‐ray/electron diffraction with first‐principles calculations. The in‐plane inorganic backbone of the MOCs exhibits a strong lattice anisotropy with odd/even alternations, which originates from that of the out‐of‐plane organic motifs via organic/inorganic accommodation. Such structural anisotropy is implied mechanically by the preferred orientation of crystal cleavage. It triggers a maximum ≈8 × distinction of in‐plane electrical conductivity of the semiconducting MOCs, plus a distinct birefringence (maximum Δn ≈ 0.03) with a dispersive orientation of dielectric axes, which rotate up to 25.7° from UV to visible‐light regime, inspiring an emerging pathway for color filtering via single crystal rotation. Such in‐plane optical characteristics also exhibit odd/even alternation and can be flexibly tuned by the designable out‐of‐plane ligands.

birefringence↗

Enhancing the cooling performance of thermocouples: a power-constrained topology optimization procedure

Abstract Heat pumping through thermoelectric devices has many advantages over traditional cooling. However, their current efficiency is a limiting factor in their implementation. In this paper, we approach the non-convex topology optimization of thermoelectrical elements for cooling applications through the method of moving asymptotes (MMA) to improve their cooling capabilities per watt usage. The optimization problem is defined for a given power budget, aiming for the minimum temperature with a known heat pumping need. The introduction of power as a constraint justifies the introduction of the voltage gradient across the thermocouple as a design variable to maintain the thermoelectrical device in its optimum power-to-heat extraction ratio. To better understand the convergence of this non-convex problem, we present a two-variable analytical thermoelectric optimization model. This example provides information on how to select the penalty parameters used to scale the three material coefficients involved in the problem to obtain lower objective values and better convergence using MMA. The analytical model shows the non-convexity of the problem and provides the recommendation to use penalization coefficients of the form $$p_k=p_{\sigma }>p_{\alpha }=1$$ p k = p σ > p α = 1 for the thermal conductivity, electrical conductivity, and Seebeck coefficients. We tested these penalization coefficients through optimizations of a model based on the 1MC10-031 commercial thermoelectric-cooler (TEC) using the finite element method (FEM). These penalization coefficients provided local minima without the need for volume constraints. With this procedure, we found designs that provided temperatures close to 10 degrees lower using 60% less semiconductor material volume compared to the initial design.

Gutiérrez, G. Reales↗

Chronological changes in soil biogeochemical properties of the glacier foreland of Midtre Lovénbreen, Svalbard, attributed to soil-forming factors

We report that Glacier forelands provide an excellent opportunity to investigate vegetation succession and soil development along the chronosequence; however, there are few studies on soil biogeochemical changes from environmental factors, aside from time. This study aimed to investigate soil development and biogeochemical changes in the glacier foreland of Midtre Lovenbreen, Svalbard, by considering various factors, including time. Eighteen vegetation and soil variables were measured at 38 different sampling sites of varying soil age, depth, and glacio-fluvial activity. Soil organic matter (SOM) was quantitatively measured, and the compositional changes in SOM were determined following size-density fractionation. In the topsoil, the soil organic carbon (SOC) and total nitrogen (N) content was found to increase along the soil chronosequence and were highly correlated with vegetation-associated variables. These findings suggest that plant-derived material was the main driver of the light fraction of SOM accumulation in the topsoil. The heavy fractions of SOM were composed of microbially transformed organic compounds, eventually contributing to SOM stabilization within short 90-yr deglaciation under harsh climatic conditions. In addition to time, the soil vertical profiles showed that other environmental parameters, also affected the soil biogeochemical properties. The high total phosphorous (P) content and electrical conductivity in the topsoil were attributed to unweathered subglacial materials and a considerable amount of inorganic ions from subglacial meltwater. The high P and magnesium content in the subsoil were attributed to parent materials, while the high sodium and potassium content in the surface soil were a result of sea-salt deposition. Glacio-fluvial runoff hampered ecosystem development by inhibiting vegetation development and SOM accumulation. This study emphasizes the importance of considering various soil-forming factors, including parent/subglacial materials, aeolian deposition, and glacio-fluvial runoff, as well as soil age, to obtain a comprehensive understanding of the ecosystem development in glacier forelands.

glacio-fluvial runoff↗

Building a Simplistic Automatic Extruder: Instrument Development Opportunities for the Laboratory

This work presents an automatic extruder as a research experience for undergraduate students. The system offers a user-friendly approach to preparing vesicles, such as liposomes or polymersomes, with a defined size and polydispersity properties crucial for research in biology and macromolecules. It comprises two syringe pumps connected by a membrane filter. The setup is controlled by software. Compared to manual extrusion, this automated system provides advantages, such as precisely controlled variables. The project describes a tool to enhance undergraduate learning in science and engineering laboratories. Building an automatic extruder serves as a simplified model of a complex industrial process. It offers a clear advantage: automating a well-understood manual extrusion process. To make this project accessible, it is broken down into three manageable tasks: software development, hardware assembly, and testing procedures. This breakdown describes the software created, the hardware components used, and the testing procedures conducted for this project. All project data, including software code, testing data, and procedures, are freely available online. This allows undergraduate students to not only begin their own projects but also contribute to this educational instrument’s ongoing development.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving Dynamic Wireless Charging System Performance For Electric Vehicles Through Variable Speed Limit Control Integration

Electric Vehicle (EV) charging has been a significant barrier to the widespread use of EVs. Traditional EV charging methods depend on cables, and there are concerns about safety, accessibility, convenience, and weather. A recent development, dynamic (or in-motion) wireless charging, enables EVs to charge wirelessly by incorporating charging infrastructure into roadways, allowing EVs to charge while moving. However, the energy transferred relies heavily on vehicle speed and time spent in the charging lane. This paper proposes an innovative solution that combines dynamic wire-less charging with Variable Speed Limit (VSL) control. This dynamic traffic control strategy adjusts speed limits based on real-time traffic, weather, and incidents. This integration of dynamic wireless charging and VSL has two potential benefits. First, it can motivate driver compliance with VSL through the incentive of charging. Second, it can promote smoother traffic flow and improve traffic safety by implementing lower speed limits at certain times. To verify these benefits, microscopic traffic simulations in SUMO were conducted under different EV penetration rates and VSL compliance rates. Simulation results reveal that the proposed approach can enhance dynamic wireless charging system performance while improving traffic flow and safety.

Xu, Guanhao [ORNL] (ORCID:0000000214326357)↗

Opportunities for Using the Industrial Assessment Center Database for Industrial Water Use Analysis

The manufacturing sector accounted for approximately 5–6% of total U.S. water use in 2015. Of that amount, 75–80% is self supplied withdrawal from surface-water and groundwater sources and the remainder is from public water supplies. Although manufacturing facilities commonly locate in water-scarce areas, water scarcity still poses a great risk to the manufacturing sector. Reliable water is necessary for any facility that relies on it for process and comfort cooling, cleaning, employee use, and steam generation. One of these barriers to water efficiency is the lack of reliable data on overall U.S. industrial water use—how it is used and the quantities required for each sector. If a facility cannot be easily compared with a facility of similar size and sector, knowing if it is effectively using water conservation best practices is difficult. One potential source of industrial water use data is the U.S. Department of Energy (DOE)–sponsored Industrial Assessment Centers (IACs). IACs are university-based organizations that provide free audits to small- and medium-sized manufacturing facilities to identify productivity improvement and waste and energy reduction opportunities. The IACs also maintain a database of all the audits conducted, which currently holds more than 19,267 assessments and 145,000 recommendations (as of July 24, 2020). This database also contains energy utility (electricity, natural gas, and other fuels) and water utility data, making it a potential data source for industrial water use. This report attempts to create regression models to predict a small- or medium-sized industrial facility’s annual water use or cost based on its industrial subsector and several possible relevant variables. Using data collected by IAC assessments, models for several industrial subsectors were generated via stepwise regression techniques to determine which variables (annual sales, number of employees, facility/plant area, annual production hours, and a water stress metric) are relevant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of HolosGen Sub-Scale Simulator with Plant Dynamics Code

The Subcritical Power Module Sub-scale Simulator (SPM-SS) has been designed and constructed by HolosGen LLC under the ARPA-E MEITNER program to simulate the thermal-hydraulic and heat transfer behavior of the full-scale Holos-Quad Subcritical Power Modules (SPMs). Four coupled SPMs, each rated at 5.5MW, form the Holos-Quad gas-cooled microreactor design. The SPM-SS represents a substantially scaled-down system with a power rating less than 40 kW, equipped with an electrically heated fuel cartridge heat exchanger, an electrically heated compressor heat exchanger, and a valve actuated turbine heat exchanger, in addition to a recuperator and a cooler heat exchanger. The fuel cartridge represents a portion of the full-scale SPM core, the compressor heat exchanger mimics the temperature changes resulting from the compressor’s turbomachinery inefficiencies, the turbine heat exchanger mimics the expansion process normally occurring through the turbine, while the recuperator and cooler heat exchangers complete the subscale simulator loop. The heaters equipping the fuel cartridge and the compressor heat exchangers are electronically controlled to simulate normal and off-normal SPM operating conditions. The full-scale Holos-Quad SPM design eliminates the traditional balance of plant and executes thermal-to-electric energy conversion by means of an intercooled Brayton cycle with decoupled compressor-turbine turbomachinery. The Holos-Quad full-scale design is equipped with a multi-stage axial Low- and High-Pressure compressor, and a multistage axial turbine. The SPM-SS is designed for testing and validation of selected components which are instead coupled by a traditional balance of plant. The SPMSS is not equipped with turbo-machinery (compressor and turbine) as the development of these components were excluded from the scope of work under the ARPA-E MEITNER funding program. The SPM-SS balance of plant enables modifications, replacement and testing of individual components with different working fluids and is designed to include the turbo-machinery components that will be developed in future research . The SPM-SS can be operated with different gases, variable mass-flow-rates, pressures, and temperatures to obtain test data for selected components, whose performance can be scaled to validate the computer model of the full-scale SPM at various conditions (e.g., start-up, transients conditions). The SPM-SS can operate at the maximum Holos-Quad design pressure of 7 MPa, and a maximum temperature limited to 650 °C by the electrical heaters. Several SPM-SS tests have been conducted and analyzed with the Plant Dynamics Code (PDC) developed at the Argonne National Laboratory (ANL). These tests aimed at validating the PDC modeled predictions of the full-scale Holos-Quad design with data from selected SPM-SS components. In order to address SPM-SS specific characteristics, such as components heat losses and absence of turbomachinery components, some modifications to the PDC have been implemented to factor the design differences from the full-scale Holos-Quad SPM to the SPM-SS. As the PDC offers capabilities to analyze systems with different working fluids, air, nitrogen, and helium were utilized as the SPM-SS working fluids. Air was utilized to fine-tune the SPM-SS Systems Structures and Components (SSCs), nitrogen was utilized to pressure test the SPM-SS loop at the SPMs design maximum pressure of 7MPa. Helium was utilized as the working fluid circulating through the SPM-SS SSCs for specific tests to validate the PDC predictions of the fuel cartridge heat exchanger. SPM-SS tests data were also analyzed with both the steady-state and transient analysis capabilities offered by the PDC. This report describes the PDC analysis of the SPM-SS tests data, including the necessary code modifications and comparison of the code results with the experimental data. Based on the results, a discussion is presented on how the analysis supports design and transient calculations of the full-scale Holos-Quad microreactor. Also based on the results of this work, recommendations are made for future optimizations of the SPM-SS components and PDC model development needs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

Assessment of InSAR Seasonal Movements at Bayou Choctaw SPR Site

Ground deformation is important to monitor for the ongoing safety and stability of underground caverns. Implementing InSAR technology to monitor site-wide surface deformation at the Strategic Petroleum Reserve has revealed seasonal ground movements at Bayou Choctaw in Louisiana. The cyclic, seasonal pattern shows soil shrinkage during the spring and summer months and soil expansion during the fall and winter months. Prior to this report, no in-depth investigation was conducted to explain this seasonal phenomenon. However, the ground movement is believed to be near-surface and not geological due to the relatively insignificant movement between years. To better understand seasonality movements, soil properties, land cover, and climatic conditions are assessed to relate near-surface water and soil interactions. The soil, land, and climatic properties all contribute to seasonal ground movement, and vegetation cover and the soil's water capacity contribute to the spatial variability of InSAR seasonal measurements at Bayou Choctaw.

02 PETROLEUM↗

Physical Compact Model for Three-Terminal SONOS Synaptic Circuit Element

A well-posed physics-based compact model for a three-terminal silicon–oxide–nitride–oxide–silicon (SONOS) synaptic circuit element is presented for use by neuromorphic circuit/system engineers. Based on technology computer aided design (TCAD) simulations of a SONOS device, the model contains a nonvolatile memristor with the state variable QM representing the memristor charge under the gate of the three-terminal element. By incorporating the exponential dependence of the memristance on QM and the applied bias V for the gate, the compact model agrees quantitatively with the results from TCAD simulations as well as experimental measurements for the drain current. The compact model is implemented through VerilogA in the circuit simulation package Cadence Spectre and reproduces the experimental training behavior for the source–drain conductance of a SONOS device after applying writing pulses ranging from –12 V to +11 V, with an accuracy higher than 90%.

42 ENGINEERING↗

An experimental study of the behavior of a high efficiency residential heat pump in cooling mode with common installation faults imposed

Faults are believed to be common in split system air-conditioner and heat pump systems, due to operating degradation or installation problems. Common faults include improper refrigerant charge, reduced evaporator airflow, liquid line restrictions, and the presence of non-condensable gas. Laboratory tests were used to quantify fault impacts on performance of a heat pump system, and impacts on indicator variables such as refrigerant temperatures and pressures. This paper describes a large set of laboratory tests implemented on a high efficiency heat pump operating in cooling mode. This system uses R-410A refrigerant and has a rotary compressor, TXV, two accumulators, and a compensator. A small number of previous experimental studies have been done previously to study the effects of some operating faults, but none has examined a modern system with these components. The tests were conducted with a range of fault intensities and driving conditions. The results are compared to previous researchers’ experimental results. The system’s performance was found to be quite robust in the presence of faults. The TXV, accumulators, and compensator significantly reduce sensitivity to refrigerant charge and liquid line restriction faults, and other faults to a lesser extent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Knowledge of lactation amenorrhea method among postpartum women in Ethiopia: a facility-based cross-sectional study

While the importance of knowledge about contraceptives in improving their utilization and thereby reducing the risk of unintended pregnancies is well documented, there are limited studies documented about the Lactational Amenorrhea Method (LAM). Thus, understanding the knowledge of postpartum mothers about LAM is essential for designing tailored interventions. This study assessed the level of knowledge about LAM and its associated factors among postpartum mothers in Ethiopia. A facility-based cross-sectional study was conducted among 3148 randomly selected postpartum participants. The study utilized multistage sampling approach in hospitals located across five regions and one city administration in Ethiopia. Data were collected using face-to-face interviews at discharge. A participant was categorized as having knowledge of LAM if she correctly answered the three LAM criteria: amenorrhea, the first 6 months, and exclusive breast feeding. A binary logistic regression model was used to identify factors associated with knowledge of LAM. Variables with p < 0.25 in the binary logistic regression were included in the multiple logistic regression. Then, associations were described using the adjusted odds ratio (AOR) along with the 95% confidence interval (CI), and statistical significance was declared at p < 0.05. Only four in 10 participants (40.6%; 95% CI 38.9–42.3) had knowledge of LAM. Participants who attended college or above educational level (AOR = 2.1, 95% CI 1.5–2.8), those with parity of two (AOR = 2.3; 95% CI 1.6–3.6) or more than two (AOR = 2.4; 95% CI 1.5–4.0), those who expressed a desire for further fertility (AOR = 1.3; 95% CI 1.1–1.5), individuals who received counselling on LAM (AOR = 3.0; 95% CI 2.6–3.7), and those who gave birth in hospital (AOR = 2.6; 95% CI 1.4–2.6) had higher odds of knowledge about LAM, compared to their counter parts. In contrary, participants resided far away from health facilities had 30% lower odd of knowledge about LAM compared to those resided near the health facilities (AOR = 0.70; 95% CI 0.6–0.8). The proportion of participants who had knowledge of LAM was low. Strengthening counseling about LAM during antenatal care and delivery with due attention to women with limited access to health facilities should be considered for increasing their level of knowledge on LAM.

60 APPLIED LIFE SCIENCES↗