Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “uncertainty relation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Precision luminosity measurement in proton–proton collisions at $\sqrt{s}$ = 13 TeV in 2015 and 2016 at CMS

The measurement of the luminosity recorded by the CMS detector installed at LHC interaction point 5, using proton–proton collisions at √s = 13 TeV in 2015 and 2016, is reported. The absolute luminosity scale is measured for individual bunch crossings using beam-separation scans (the van der Meer method), with a relative precision of 1.3 and 1.0% in 2015 and 2016, respectively. The dominant sources of uncertainty are related to residual differences between the measured beam positions and the ones provided by the operational settings of the LHC magnets, the factorizability of the proton bunch spatial density functions in the coordinates transverse to the beam direction, and the modeling of the effect of electromagnetic interactions among protons in the colliding bunches. When applying the van der Meer calibration to the entire run periods, the integrated luminosities when CMS was fully operational are 2.27 and 36.3 fb -1 in 2015 and 2016, with a relative precision of 1.6 and 1.2%, respectively. These are among the most precise luminosity measurements at bunched-beam hadron colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simultaneous XAFS measurements of multiple samples

A four-channel ionization chamber has been designed, constructed and tested. This ionization chamber allows X-ray absorption spectra to be collected in transmission from up to four samples simultaneously. This results in spectra that are free of systematic uncertainty in relative energy alignment introduced by scan-to-scan stability of the monochromator or of numerical uncertainty associated with a post-processing alignment algorithm, allowing, in a single shot, an absolute measure of edge shift between four samples of different valence. As four samples can be measured in parallel, the time expended over the course of an experiment to cycle the measurement environment between its rest state and the measurement condition is substantially reduced. The ionization chamber is simple in design and could be implemented at virtually any XAFS beamline with a horizontal fan of radiation such as that provided by a bend magnet or wiggler.

47 OTHER INSTRUMENTATION↗

Phase space analysis of inclusive charged current proton production in MicroBooNE

Using the full ve-dimensional phase space, measuring the relative fraction of charged current events containing a proton in the nal state originates from quasielastic, 2p2h, resonance, and deep inelastic sub-nuclear scattering processes within the context of the GENIE cross section model. These studies indicate that the data support the picture that charged current scattering is dominated by a relatively small number of incoherent nucleon-level processes. GENIE successfully predicts, within the estimated experimental uncertainties, the relative contributions of each subnuclear process. This analysis of MicroBooNE data establishes the presence of a 2p2h contribution to the cross section to a significance of 7:3 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of wind and moisture gradients on the arbitrary assignment of cloud motions to a vertical coordinate system in two Sesame cases

Satellite-derived cloud motion 'wind' vectors (CMV) are increasingly used in mesoscale and in global analyses, and questions have been raised regarding the uncertainty of the level assignment for the CMV. One of two major problems in selecting a level for the CMV is related to uncertainties in assigning the motion vector to either the cloud top or base. The second problem is related to the inability to transfer the 'wind' derived from the CMV at individually specified heights to a standard coordinated surface. The present investigation has the objective to determine if the arbitrary level assignment represents a serious obstacle to the use of cloud motion wind vectors in the mesoscale analysis of a severe storm environment.

Peslen, C. A.↗

Comparing evapotranspiration from Eddy covariance measurements, water budgets, remote sensing, and land surface models over Canada a, b

Here, this study compares six evapotranspiration ET products for Canada's landmass, namely, eddy covariance EC measurements; surface water budget ET; remote sensing ET from MODIS; and land surface model (LSM) ET from the Community Land Model (CLM), the Ecological Assimilation of Land and Climate Observations (EALCO) model, and the Variable Infiltration Capacity model (VIC). The ET climatology over the Canadian landmass is characterized and the advantages and limitations of the datasets are discussed. The EC measurements have limited spatial coverage, making it difficult for model validations at the national scale. Water budget ET has the largest uncertainty because of data quality issues with precipitation in mountainous regions and in the north. MODIS ET shows relatively large uncertainty in cold seasons and sparsely vegetated regions. The LSM products cover the entire landmass and exhibit small differences in ET among them. Annual ET from the LSMs ranges from small negative values to over 600 mm across the landmass, with a countrywide average of 256 ± 15 mm. Seasonally, the countrywide average monthly ET varies from a low of about 3 mm in four winter months (November-February) to 67 ± 7 mm in July. The ET uncertainty is scale dependent. Larger regions tend to have smaller uncertainties because of the offset of positive and negative biases within the region. More observation networks and better quality controls are critical to improving ET estimates. Future techniques should also consider a hybrid approach that integrates strengths of the various ET products to help reduce uncertainties in ET estimation.

54 ENVIRONMENTAL SCIENCES↗

Discovering the nature of neutrinos: How nuclear theory will advance this grand endeavor. Final report

Why is there more matter than antimatter in the visible universe? Are neutrinos their own antiparticles? These are some of the most profound questions in science. The detection of a (0vββ) neutrinoless doublebeta decay and the measurement of its half-life is one of the most important experimental endeavors in science because it will answer these questions. Paramount to these measurements are accurate predictions with quantified uncertainties of the 0vββ-decay nuclear transitions, especially for the germanium-76 and xeon-136 nuclei, two candidate materials for building the next generation of DOE funded 0vββ-decay experiments. These predictions will guide the Office of Science’s down selection of experiments as well as aid in determining how much material is needed by these experiments. We studied a specific difficult to assess source of uncertainty that will impact coming microscopic predictions, uncertainty which arises from an incomplete yet systematically improvable model of interactions between nucleons and of nucleons with the other particles involved in decay process, referred to as the theory uncertainty. We employed a surrogate model of the germanium-76 nucleus, and its decay products, just detailed enough to adequately mimic the decaying nucleons need for a reasonable measure of this uncertainty and nothing more, avoiding the immense computational expense required in quantifying uncertainties of the full calculation. We found that microscopic calculations of this process can be expected to achieve relative theory uncertainties around 30%, including an unconstrained contribution that had the potential to spoil microscopic calculations. This results in a nearly order of magnitude on previously estimated uncertainties for this rare decay process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Satellite and correlative measurements of the stratospheric aerosol. III - Comparison of measurements by SAM II, SAGE, dustsondes, filters, impactors and lidar

The SAM II and SAGE satellite sensors, dustsondes, impactors, a filter collector and an airborne lidar were used in a large satellite validation experiment on July 16-19, 1979, at Poker Flat, Alaska. Independent measurements of extinction profiles by SAM II and SAGE are noted to agree with each other and with those derived from the other instruments (within combined uncertainties). The wire impactor-derived results, while also consistent with the others, are coarse due to the relatively large uncertainties in impactor-derived mass, extinction, and number of particles/unit volume whose radius is greater than x microns.

Russell, P. B.↗

Estimating Uncertainties in the Multi-Instrument SBUV Profile Ozone Merged Data Set

The MOD data set is uniquely qualified for use in long-term ozone analysis because of its long record, high spatial coverage, and consistent instrument design and algorithm. The estimated MOD uncertainty term significantly increases the uncertainty over the statistical error alone. Trends in the post-2000 period are generally positive in the upper stratosphere, but only significant at 1-1.6 hPa. Remaining uncertainties not yet included in the Monte Carlo model are Smoothing Error ( 1 from 10 to 1 hPa) Relative calibration uncertainty between N11 and N17Seasonal cycle differences between SBUV records.

Uncertainties↗

Invited Article: A precise instrument to determine the Planck constant, and the future kilogram

A precise instrument, called a watt balance, compares mechanical power measured in terms of the meter, the second, and the kilogram to electrical power measured in terms of the volt and the ohm. A direct link between mechanical action and the Planck constant is established by the practical realization of the electrical units derived from the Josephson and the quantum Hall effects. We describe in this paper the fourth-generation watt balance at the National Institute of Standards and Technology (NIST), and report our initial determination of the Planck constant obtained from data taken in late 2015 and the beginning of 2016. A comprehensive analysis of the data and the associated uncertainties led to the SI value of the Planck constant, h = 6.626 069 83(22) × 10{sup −34} J s. The relative standard uncertainty associated with this result is 34 × 10{sup −9}.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

SU-E-T-107: An Investigation Into Attenuation Effects On the Energy Spectrum for {sup 137}Cs Using Monte Carlo Techniques

Purpose: The calibration of radiation protection instrumentation including ionization chambers, scintillators, and Geiger Mueller (GM) counters used as survey meters are often done using {sup 137}Cs irradiators. During calibration, irradiators use a combination of attenuators with various thicknesses to modulate the beam to a known air-kerma rate. The variations in energy spectra as a result of these attenuators are not accounted for and may play a role in the energy-dependent response of survey meters. This study uses an experimentally validated irradiator geometry modeled in the MCNP5 transport code to characterize the effects of attenuation on the energy spectrum. Methods: A Hopewell Designs G-10 {sup 137}Cs irradiator with lead attenuators of thicknesses of 0.635, 1.22, 2.22, and 4.32 cm, was used in this study. The irradiator geometry was modeled in MCNP5 and validated by comparing measured and simulated percent depth dose (PDD) and cross-field profiles. Variations in MCNP5 simulated spectra with increasing amounts of attenuation were characterized using the relative intensity of the 662 keV peak and the average energy. Results: Simulated and measured PDDs and profiles agreed within the associated uncertainty. The relative intensity of the 662 keV peak for simulated spectra normalized to the intensity of the unattenuated spectra ranged from 0.16% to 100% based on attenuation thickness. The average energy for simulated spectra for attenuators ranged from 582 keV with no attenuation to 653 keV with 5.54 cm of attenuation. Statistical uncertainty for MCNP5 simulations ranged from 0.11% to 3.69%. Conclusion: This study successfully used MCNP5 to validate a {sup 137}Cs irradiator geometry and characterize variations in energy spectra between different amounts of attenuation. Variations in the average energy of up to 12% were determined through simulations, and future work will aim to determine the effects of these differences on survey meter response and calibration.

07 ISOTOPE AND RADIATION SOURCES↗

SYSTEMATIC CONTINUUM ERRORS IN THE Ly{alpha} FOREST AND THE MEASURED TEMPERATURE-DENSITY RELATION

Continuum fitting uncertainties are a major source of error in estimates of the temperature-density relation (usually parameterized as a power-law, T {proportional_to} {Delta}{sup {gamma}-1}) of the intergalactic medium through the flux probability distribution function (PDF) of the Ly{alpha} forest. Using a simple order-of-magnitude calculation, we show that few percent-level systematic errors in the placement of the quasar continuum due to, e.g., a uniform low-absorption Gunn-Peterson component could lead to errors in {gamma} of the order of unity. This is quantified further using a simple semi-analytic model of the Ly{alpha} forest flux PDF. We find that under(over)estimates in the continuum level can lead to a lower (higher) measured value of {gamma}. By fitting models to mock data realizations generated with current observational errors, we find that continuum errors can cause a systematic bias in the estimated temperature-density relation of ({delta}({gamma})) Almost-Equal-To -0.1, while the error is increased to {sigma}{sub {gamma}} Almost-Equal-To 0.2 compared to {sigma}{sub {gamma}} Almost-Equal-To 0.1 in the absence of continuum errors.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-Causal Controller Approximation Methodology Augmented with Model Reference Control – Robust Design

This paper describes the development of a new control design methodology based on a non-causal controller structure and its approximation. The non-causal controller design is based on a loop shaping approach. Partial fraction decomposition is used, along with derivative approximations, to derive a proper transfer function design for a causal control structure. The premise for this non-causal control methodology is that the phase delay as a function of frequency ideally remains within approximately -90o, which tends to make the system robustly stable to uncertainties in the plant dynamics. To have a predictable control system response in lieu of the tolerance of this methodology to relatively large uncertainty in the plant dynamics, the approach is augmented with model reference control. The addition of model reference control can potentially further enhance the robustness of the design. A control system design example is presented in this paper, along with simulation results, to demonstrate the high degree of robustness of this non-causal methodology and its augmentation.

Control Systems↗

Annealing a Follow-up Program: Improvement of the Dark Energy Figure of Merit for Optical Galaxy Cluster Surveys

The precision of cosmological parameters derived from galaxy cluster surveys is limited by uncertainty in relating observable signals to cluster mass. We demonstrate that a small mass-calibration follow-up program can significantly reduce this uncertainty and improve parameter constraints, particularly when the follow-up targets are judiciously chosen. To this end, we apply a simulated annealing algorithm to maximize the dark energy information at fixed observational cost, and find that optimal follow-up strategies can reduce the observational cost required to achieve a specified precision by up to an order of magnitude. Considering clusters selected from optical imaging in the Dark Energy Survey, we find that approximately 200 low-redshift X-ray clusters or massive Sunyaev-Zel'dovich clusters can improve the dark energy figure of merit by 50%, provided that the follow-up mass measurements involve no systematic error. In practice, the actual improvement depends on (1) the uncertainty in the systematic error in follow-up mass measurements, which needs to be controlled at the 5% level to avoid severe degradation of the results; and (2) the scatter in the optical richness-mass distribution, which needs to be made as tight as possible to improve the efficacy of follow-up observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Catalytic resonance theory for parametric uncertainty of programmable catalysis

Microkinetic models are useful tools for screening catalytic materials; however, errors in their input parameters can lead to significant uncertainty in model predictions of catalyst performance. Here, in this work, we investigate the impact of linear scaling and Brønsted-Evans-Polanyi relation parametric uncertainty on microkinetic predictions of programmable-catalyst performance. Two case studies are considered: a generic A-to-B prototype reaction and the oxygen evolution reaction (OER). The results show that error-unaware models can accurately predict trends and, for the prototype reaction, values of optimal waveform parameters. The specific model parameters driving output uncertainty are identified via variance-based global sensitivity analysis. However, predictions of dynamic rate enhancement can decrease when uncertainty is propagated into the models. In both cases, we identify operating conditions where the programmable catalyst achieves a rate enhancement of at least one order of magnitude despite parametric uncertainty in the model, supporting programmable catalysis as a viable strategy for exceeding the Sabatier limit.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technique for Targeting Arteriovenous Malformations Using Frameless Image-Guided Robotic Radiosurgery

Purpose: To integrate three-dimensional (3D) digital rotation angiography (DRA) and two-dimensional (2D) digital subtraction angiography (DSA) imaging into a targeting methodology enabling comprehensive image-guided robotic radiosurgery of arteriovenous malformations (AVMs). Methods and Materials: DRA geometric integrity was evaluated by imaging a phantom with embedded markers. Dedicated DSA acquisition modes with preset C-arm positions were configured. The geometric reproducibility of the presets was determined, and its impact on localization accuracy was evaluated. An imaging protocol composed of anterior-posterior and lateral DSA series in combination with a DRA run without couch displacement between acquisitions was introduced. Software was developed for registration of DSA and DRA (2D-3D) images to correct for: (a) small misalignments of the C-arm with respect to the estimated geometry of the set positions and (b) potential patient motion between image series. Within the software, correlated navigation of registered DRA and DSA images was incorporated to localize AVMs within a 3D image coordinate space. Subsequent treatment planning and delivery followed a standard image-guided robotic radiosurgery process. Results: DRA spatial distortions were typically smaller than 0.3 mm throughout a 145-mm x 145-mm x 145-mm volume. With 2D-3D image registration, localization uncertainties resulting from the achievable reproducibility of the C-arm set positions could be reduced to about 0.2 mm. Overall system-related localization uncertainty within the DRA coordinate space was 0.4 mm. Image-guided frameless robotic radiosurgical treatments with this technique were initiated. Conclusions: The integration of DRA and DSA into the process of nidus localization increases the confidence with which radiosurgical ablation of AVMs can be performed when using only an image-guided technique. Such an approach can increase patient comfort, decrease time pressure on clinical and technical staff, and possibly reduce the number of cerebral angiograms needed for a particular patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation testing of the Canberra mobile Feed Roll Assay system - 15404

Japanese farmers grow various grasses as feed for cattle. These are rolled up and sealed for future use. Canberra has created a special truck to monitor these Feed Rolls, called 'Feed Roll Assay System [FRAS]'. On the bed of the truck is the shield containing a large NaI detector. The detector is 3x5x16'' in size, the same size as used in the Canberra FastScan Whole Body Counter. The detector is also LED-stabilized, to keep the gain constant under the wide range of temperature variations expected for this outdoor measurement instrument. The Canberra Osprey digital MCA is connected to the detector. The detector and the MCA are housed in a water proof box, which is surrounded on the bottom and all sides by a 15 cm thick steel shield. A portion of the shield at the top is open where the detector can view the Feed Rolls placed there. A single ethernet cable goes to a laptop PC which provides power to the MCA and detector, and also transmits the signal to the PC. The system was calibrated using MCNP for a variety of different densities, and Feed Roll sizes. The Japanese version of the Canberra Genie software is used to analyze the spectra and compute the Bq/kg concentration of the Feed Roll. The shielding is sufficient so that at a 5 uSv/hr background dose rate, no Cs-137 or Cs-134 peaks were detected in a 1 hour count. Measurements were performed in 0.2 uSv/hr dose rate, using uncontaminated Feed Rolls at various counting times. The MDA for Cs-137 was 11.9 Bq/kg at 30 seconds, 8.2 Bq/kg for 60 seconds, and 1.1 Bq/kg at 3600 seconds count time. The relative measurement uncertainty of the FRAS measurements was 9.4 to 13%, as compared to assays of samples extracted [30-45%] and in-situ Ge measurements [6.0 - 7.1%]. The FRAS measurement results have considerably better precision than measurements of samples extracted from the Feed Rolls, and are much faster than the in-situ Ge measurements and have just about the same uncertainty. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling uncertainties in greenhouse gas (GHG) emission factors related to switchgrass-based biofuel production

This study investigates uncertainties in greenhouse gas (GHG) emission factors related to switchgrass-based biofuel production in Michigan. Using three life cycle assessment (LCA) databases— US lifecycle inventory database (USLCI), GREET, and Ecoinvent—each with multiple versions, we recalculated the global warming intensity (GWI) and GHG mitigation potential in a static calculation. Employing Monte Carlo simulations along with local and global sensitivity analyses, we assess uncertainties and pinpoint key parameters influencing GWI.

greenhouse ga emmission↗

Understanding Material Strength Variabilities and Uncertainties for Component Qualification (2020 LDRD Final Report)

At its core, material specification and materials qualification require an understanding of the uncertainties in relation to a given performance metric. When simulations are used to inform the design and evaluation of these metrics, it is essential to understand the uncertainties in the underlying models and parameters that feed into those simulations. In this work, we have created a statistical framework to address uncertainties in the materials strength modeling used in integrated simulations. The framework is based on the Bayesian methodology, which allows for uncertainties to be updated as new data become available. The results of this work show how model parameters and their uncertainties can be updated as new and different types of strength data are added, as well as methods for determining which future experiment has the greatest potential to reduce the uncertainty. The statistical framework developed in this project will be utilized to assess and propagate the uncertainties in the strength models used in the programmatic simulations and to create a way to formally update those uncertainties as new data become available.

36 MATERIALS SCIENCE↗