Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Assessment of Interfraction Patient Setup for Head-and-Neck Cancer Intensity Modulated Radiation Therapy Using Multiple Computed Tomography-Based Image Guidance

Purpose: Various image guidance systems are commonly used in conjunction with intensity modulated radiation therapy (IMRT) in head-and-neck cancer irradiation. The purpose of this study was to assess interfraction patient setup variations for 3 computed tomography (CT)-based on-board image guided radiation therapy (IGRT) modalities. Methods and Materials: A total of 3302 CT scans for 117 patients, including 53 patients receiving megavoltage cone-beam CT (MVCBCT), 29 receiving kilovoltage cone-beam CT (KVCBCT), and 35 receiving megavoltage fan-beam CT (MVFBCT), were retrospectively analyzed. The daily variations in the mediolateral (ML), craniocaudal (CC), and anteroposterior (AP) dimensions were measured. The clinical target volume-to-planned target volume (CTV-to-PTV) margins were calculated using 2.5Σ + 0.7 σ, where Σ and σ were systematic and random positioning errors, respectively. Various patient characteristics for the MVCBCT group, including weight, weight loss, tumor location, and initial body mass index, were analyzed to determine their possible correlation with daily patient setup. Results: The average interfraction displacements (± standard deviation) in the ML, CC, and AP directions were 0.5 ± 1.5, −0.3 ± 2.0, and 0.3 ± 1.7 mm (KVCBCT); 0.2 ± 1.9, −0.2 ± 2.4, and 0.0 ± 1.7 mm (MVFBCT); and 0.0 ± 1.8, 0.5 ± 1.7, and 0.8 ± 3.0 mm (MVCBCT). The day-to-day random errors for KVCBCT, MVFBCT, and MVCBCT were 1.4-1.6, 1.7, and 2.0-2.1 mm. The interobserver variations were 0.8, 1.1, and 0.7 mm (MVCBCT); 0.5, 0.4, and 0.8 mm (MVFBCT); and 0.5, 0.4, and 0.6 mm (KVCBCT) in the ML, CC, and AP directions, respectively. The maximal calculated uniform CTV-to-PTV margins were 5.6, 6.9, and 8.9 mm for KVCBCT, MVFBCT, and MVCBCT, respectively. For the evaluated patient characteristics, the calculated margins for different patient parameters appeared to differ; analysis of variance (ANOVA) and/or t test analysis found no statistically significant setup difference in any direction. Conclusions: Daily random setup errors and CTV-to-PTV margins for treatment of head-and-neck cancer were affected by imaging quality. Our data indicated that larger margins were associated with MVFBCT and MVCBCT, compared with smaller margins for KVCBCT. IGRT modalities with better image quality are encouraged in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison study of the partial-breast irradiation techniques: Dosimetric analysis of three-dimensional conformal radiation therapy, electron beam therapy, and helical tomotherapy depending on various tumor locations

The partial-breast irradiation (PBI) technique, an alternative to whole-breast irradiation, is a beam delivery method that uses a limited range of treatment volume. The present study was designed to determine the optimal PBI treatment modalities for 8 different tumor locations. Treatment planning was performed on computed tomography (CT) data sets of 6 patients who had received lumpectomy treatments. Tumor locations were classified into 8 subsections according to breast quadrant and depth. Three-dimensional conformal radiation therapy (3D-CRT), electron beam therapy (ET), and helical tomotherapy (H-TOMO) were utilized to evaluate the dosimetric effect for each tumor location. Conformation number (CN), radical dose homogeneity index (rDHI), and dose delivered to healthy tissue were estimated. The Kruskal-Wallis, Mann-Whitney U, and Bonferroni tests were used for statistical analysis. The ET approach showed good sparing effects and acceptable target coverage for the lower inner quadrant—superficial (LIQ-S) and lower inner quadrant—deep (LIQ-D) locations. The H-TOMO method was the least effective technique as no evaluation index achieved superiority for all tumor locations except CN. The ET method is advisable for treating LIQ-S and LIQ-D tumors, as opposed to 3D-CRT or H-TOMO, because of acceptable target coverage and much lower dose applied to surrounding tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of tumor location on the intensity-modulated radiation therapy plan of helical tomotherapy

Given the design of the Helical TomoTherapy device, the patient's central axis is routinely aligned with the machine's rotational axis to prevent the patient's body from colliding with the machine walls. However, for treatment of tumors located away from the patient's central axis, this position may not be optimal as the adequate radiation dose may not reach the affected site. Our study aimed to investigate the influence of tumor location on dose quality and delivery efficiency of tomotherapy plans. A phantom and 15 patients were selected for this study. Two plans, A and B, were implemented for each case. In plan A, the patient's central axis was aligned with the machine's rotational axis, whereas in plan B, the center of the planning target volume (PTV) was aligned with the machine's rotational axis. Both plans were optimized with the same planning parameters, and the dose quality of the plans was evaluated using dosimetrics. The delivery efficiency was determined from delivery time and monitor units (MUs). A paired t-test or nonparametric Wilcoxon signed-rank test was performed for statistical comparison. In the phantom study, the median delivery times were 358 and 336 seconds for plans A and B, respectively, and this difference was significant (p = 0.005). In the patient study, the median delivery times were 348 and 317 seconds for plans A and B, respectively, and this difference was also significant (p = 0.001). The dose qualities of both plans for each patient were nearly identical. No significant differences were found in the conformal index, heterogeneity index, and mean dose delivered to normal tissue between the plans. Both phantom and patient studies showed that for normal-sized patients, the delivery time reduced as the distance between the PTV and the patient's central axis increased when the PTV center was aligned with the machine axis. In conclusion, aligning the PTV center with the machine's rotational axis by shifting the patient during tomotherapy reduces the delivery time without compromising the dose quality of intensity-modulated radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving ChemCam LIBS long-distance elemental compositions using empirical abundance trends

The ChemCam instrument on the Curiosity rover provides chemical compositions of Martian rocks and soils using remote laser-induced breakdown spectroscopy (LIBS). The elemental calibration is stable as a function of distance for Ti, Fe, Mg, and Ca. The calibration shows small, systematically increasing abundance trends as a function of distance for Al, Na, K, and to some extent, Si. The distance effect is known to be due to a dependence with distance on the relative strengths of atomic transition lines. Emission lines representing transitions from relatively low energy levels remain intense at longer distances while emission lines representing transitions from higher energy levels decrease in intensity more rapidly as a function of distance. The multivariate algorithms used to determine elemental compositions rely on a large number of emission lines in many cases, so rather than trying to correct all emission lines, a study was made of the predicted compositions as a function of distance, in order to determine an empirical correction. Abundance trends can be well approximated by a linear trend with distance within the ranges of abundances and distances observed up to ~6 m. Data from 11 distinct geological members and data groups of the Murray formation in Gale crater, Mars, were used to form the model, selecting the members and data groups yielding the best statistics. The model was tested using data from several targets observed from two different distances, and using data from the Kimberley formation, the composition of which is significantly different from the Murray formation, showing that the model works on other compositions beyond those used to build the model. For long-distance observations up to ~6 m, corrections can be made back to an equivalent composition at the median distance of ChemCam observations (2.6 m). Finally, the model has been validated up to 6.2 m, although ChemCam is able to observe bedrock targets to >7 m, and iron meteorites to distances of >9 m.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time Matters: A Survival Analysis of Public Electric Vehicle Charging Infrastructure Utilization

The rapid adoption of plug-in electric vehicles (PEVs) places significant demands on public charging infrastructure, making it critical to understand and optimize charger utilization. This study provides one of the most comprehensive analyses of charging behavior to date by applying a survival analysis to a dataset of nearly 16 million level 2 (L2) and direct current (DC) fast charger sessions across the United States from 2017 to 2022. Using Kaplan-Meier curves and log rank tests, our analysis reveals statistically significant and distinct duration patterns influenced by charger type, time of day, and day of the week. We find that L2 charging sessions exhibit high variability tied to venue type, whereas DC sessions are more uniform, typically lasting 30-45 min. This study introduces the operational efficiency score (OES), a metric for standardizing the performance evaluation of charging stations. Our findings offer actionable insights for optimizing charger deployment, developing dynamic pricing strategies to reduce vehicle dwell time, and improving load management for grid operators, ultimately enhancing the efficiency and availability of public charging infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Batch Scale Production of 3D Printed Extraction Sorbents Using a Low-Cost Modification to a Desktop Printer

This study reports a simple modification to a commercial resin 3D printer that significantly reduces the amount of prepolymer material needed for the production of extraction sorbents. Here, the modified printing platform is demonstrated in the printing of two imidazolium-based ionic liquid (IL) monomers. Two geometries resembling a blade-type polymeric ionic liquid (PIL) sorbent used in thin-film microextraction and a fiber-type sorbent used in solid-phase microextraction (SPME) were printed. The SPME PIL sorbents were used to extract 10 organic contaminants, including plasticizers, antimicrobial agents, UV filters, and pesticides, from water followed by high-performance liquid chromatographic (HPLC) analysis. To compare the extraction performance of the SPME sorbents, seven fibers printed with the same prepolymer composition from the same printing batch as well as different batches were evaluated. The results revealed highly reproducible extraction efficiencies for all tested sorbents with no statistical difference in their extraction performance. Method validation showed acceptable linearity ($R$ 2 > 0.92) for all analytes with limits of detection and limits of quantification ranging from 0.13 to 45 μg L –1 and 0.43 to 150 μg L –1 , respectively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerated Fill‐Up of the Arbuckle Group Aquifer and Links to U.S. Midcontinent Seismicity

The Arbuckle Group aquifer is the principal disposal zone for oil and gas field brines and hazardous/nonhazardous wastewater across the U.S. midcontinent and is traditionally viewed as an infinite capacity aquifer. Thousands of wells annually dispose hundreds of millions of barrels of wastewater into the aquifer across Kansas and Oklahoma, but direct links between injection and recent increases in seismicity have been hindered by a lack of pressure data for the Arbuckle Group. Here we present a newly compiled data set for 49 wells across Kansas that provides a unique perspective on the aquifer's performance over two decades. Statistical analysis of falloff test pressures, static fluid levels, and injection volumes shows that Arbuckle pressures and fluid levels are rising, recently at faster rates, likely associated with increased wastewater injection. The new data also suggest that the pressure diffusion, the primary driver of induced seismicity, can reach distances up to 25 km from an injection point and is connected to static fluid level rises. The compiled dataset explains the recent surge in midcontinent seismicity. The data set also suggests that the Arbuckle has finite storage capacity and that wastewater disposal across parts of the midcontinent may soon require alternatives.

58 GEOSCIENCES↗

Lattice Calculations of Nucleon Form Factors

We present recent results of calculation of the isovector electromagnetic and axial form factors of the nucleon using lattice QCD with three different lattice actions and pion masses down to m{sub {pi}} > or approx. 300 MeV. Because of the precision of our high-statistics calculations, we can test predictions of baryon chiral perturbation theory for the charge and axial radii of the nucleon. We find that currently available baryon ChPT calculations disagree with our data, indicating that the corresponding effective theory approximations are not valid above m{sub {pi}{approx_equal}3}00 MeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electromigration kinetics and critical current of Pb-free interconnects

Electromigration kinetics of Pb-free solder bump interconnects have been studied using a single bump parameter sweep technique. By removing bump to bump variations in structure, texture, and composition, the single bump sweep technique has provided both activation energy and power exponents that reflect atomic migration and interface reactions with fewer samples, shorter stress time, and better statistics than standard failure testing procedures. Contact metallurgies based on Cu and Ni have been studied. Critical current, which corresponds to the Blech limit, was found to exist in the Ni metallurgy, but not in the Cu metallurgy. A temperature dependence of critical current was also observed.

36 MATERIALS SCIENCE↗

A fast exact simulation method for a class of Markov jump processes

A new method of the stochastic simulation algorithm (SSA), named the Hashing-Leaping method (HLM), for exact simulations of a class of Markov jump processes, is presented in this paper. The HLM has a conditional constant computational cost per event, which is independent of the number of exponential clocks in the Markov process. The main idea of the HLM is to repeatedly implement a hash-table-like bucket sort algorithm for all times of occurrence covered by a time step with length τ. This paper serves as an introduction to this new SSA method. We introduce the method, demonstrate its implementation, analyze its properties, and compare its performance with three other commonly used SSA methods in four examples. Our performance tests and CPU operation statistics show certain advantages of the HLM for large scale problems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of the accuracy of coupled cluster perturbation theory for open-shell systems. I. Triples expansions

The accuracy at which total energies of open-shell atoms and organic radicals may be calculated is assessed for selected coupled cluster perturbative triples expansions, all of which augment the coupled cluster singles and doubles (CCSD) energy by a non-iterative correction for the effect of triple excitations. Namely, the second- through sixth-order models of the recently proposed CCSD(T–n) triples series [J. J. Eriksen et al., J. Chem. Phys. 140, 064108 (2014)] are compared to the acclaimed CCSD(T) model for both unrestricted as well as restricted open-shell Hartree-Fock (UHF/ROHF) reference determinants. By comparing UHF- and ROHF-based statistical results for a test set of 18 modest-sized open-shell species with comparable RHF-based results, no behavioral differences are observed for the higher-order models of the CCSD(T–n) series in their correlated descriptions of closed- and open-shell species. In particular, we find that the convergence rate throughout the series towards the coupled cluster singles, doubles, and triples (CCSDT) solution is identical for the two cases. For the CCSD(T) model, on the other hand, not only its numerical consistency, but also its established, yet fortuitous cancellation of errors breaks down in the transition from closed- to open-shell systems. The higher-order CCSD(T–n) models (orders n > 3) thus offer a consistent and significant improvement in accuracy relative to CCSDT over the CCSD(T) model, equally for RHF, UHF, and ROHF reference determinants, albeit at an increased computational cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tests for, origins of, and corrections to non-Gaussian statistics. The dipole-flip model

Linear response approximations are central to our understanding and simulations of nonequilibrium statistical mechanics. Despite the success of these approaches in predicting nonequilibrium dynamics, open questions remain. Laird and Thompson [J. Chem. Phys. 126, 211104 (2007)] previously formalized, in the context of solvation dynamics, the connection between the static linear-response approximation and the assumption of Gaussian statistics. The Gaussian statistics perspective is useful in understanding why linear response approximations are still accurate for perturbations much larger than thermal energies. In this study, we use this approach to address three outstanding issues in the context of the “dipole-flip” model, which is known to exhibit nonlinear response. First, we demonstrate how non-Gaussian statistics can be predicted from purely equilibrium molecular dynamics (MD) simulations (i.e., without resort to a full nonequilibrium MD as is the current practice). Second, we show that the Gaussian statistics approximation may also be used to identify the physical origins of nonlinear response residing in a small number of coordinates. Third, we explore an approach for correcting the Gaussian statistics approximation for nonlinear response effects using the same equilibrium simulation. Finally, the results are discussed in the context of several other examples of nonlinear responses throughout the literature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting the viscoplastic response of a crystallizing fluoropolymer using transient network theory

We employ a molecular theory of dynamic polymer networks to describe the viscoplastic response of rubbery FK-800, a thermoplastic copolymer of chlorotrifluoroethylene and vinylidene fluoride, over a broad range of thermal histories. The kinetics of crystallization at different annealing temperatures was modeled using a modified Avrami equation, whose parameters were found to evolve through simple relationships over the full temperature range of the rubbery state. By fitting experimental compression data, we discovered predictable trends for the physical parameters in our mechanical model over its full range of crystallinities (up to ≈20%) and provided insights based on molecular-level physics to justify them. Using this, an end-to-end model was developed to predict the yielding and post-yield behavior of rubbery FK-800 for arbitrary thermal histories. The model successfully predicted the highly nonlinear evolution of characteristic mechanical signatures (stiffness, yield point, post-yield drop) throughout the crystallization process. A statistical analysis of variance test was employed to determine that the measured variations in the mechanical behavior of rubbery FK-800 are primarily dictated by its fractional crystallinity, regardless of its exact thermal history.

36 MATERIALS SCIENCE↗

Assessment of Lignite Quality Variables: A Practical Approach with Sequential Gaussian Simulation

Traditional mine planning methods based on block models built with interpolation techniques such as inverse distance and kriging are inadequate in assessing the uncertainty associated with the technological parameters of coal deposit variables, which are modeled for short-range mine planning because of smoothing effects. However, simulation methods aim at reproducing in situ quality variability and spatial continuity of the attributes of interest. This study outlines the spatial distribution and uncertainty of quality variables at the Tufanbeyli (Adana-Turkey) lignite deposit using a probabilistic approach. A practical approach was based on geostatistical sequential Gaussian simulation (SGS) used to yield a series of conditional images characterized by equally probable spatial distributions of the quality parameters across the deposit. Post processing of many simulations allowed the mapping of maximum/minimum limits for quality values and provided a model for the uncertainty in the spatial distribution of the quality parameters. SGS was validated by a number of tests such as descriptive statistics, histogram, and variogram reproductions. The advantages of SGS were practically illustrated through the case study. The simulated models can be incorporated into mine planning and scheduling.

01 COAL, LIGNITE, AND PEAT↗

OB ASSOCIATIONS AT THE UPPER END OF THE MILKY WAY LUMINOSITY FUNCTION

The Milky Way's most luminous, young, and massive (M {approx}> 10{sup 4} M{sub Sun }) star clusters and OB associations have largely evaded detection despite knowledge of their surrounding H II regions. We search for these clusters and associations within the 40 star-forming complexes from Rahman and Murray in the 13 most luminous Wilkinson Microwave Anisotropy Probe (WMAP) free-free emission sources of the Galaxy. Selecting for objects with the dust-reddened colors of OB stars, we identify new candidate associations using the Two Micron All Sky Survey point-source catalog. In 40 star-forming complexes searched, 22 contain cluster/association candidates with sizes and masses in the range of 3'-26' and 10{sup 2.3}-10{sup 5} M{sub Sun }. Of the 22 candidates, at least seven have estimated masses {approx}> 10{sup 4} M{sub Sun }, doubling the number of such massive clusters known in the Galaxy. Only one of the searched WMAP sources remains without a candidate. Applying our method to a statistically similar set of test locations, we estimate that 3.0 {+-} 0.6 of our 22 candidate associations are unrelated to the star-forming complexes. In addition, the apparent extinctions of our candidate associations correlate well with the predictions from a Galactic model. These facts, along with the clear detection of a known OB association and the previous spectral verification of one cluster found by this method, validate our method. In eight of the most luminous WMAP sources, the candidate associations can account for the observed free-free flux. With our new compilation, the Galactic census of young, massive stellar associations may now be about half complete.

79 ASTRONOMY AND ASTROPHYSICS↗

Angular correlation of cosmic neutrinos with ultrahigh-energy cosmic rays and implications for their sources

Cosmic neutrino events detected by the IceCube Neutrino Observatory with energy 0∼> 3 TeV have poor angular resolutions to reveal their origin. Ultrahigh-energy cosmic rays (UHECRs), with better angular resolutions at 0>6 EeV energies, can be used to check if the same astrophysical sources are responsible for producing both neutrinos and UHECRs. We test this hypothesis, with statistical methods which emphasize invariant quantities, by using data from the Pierre Auger Observatory, Telescope Array and past cosmic-ray experiments. We find that the arrival directions of the cosmic neutrinos are correlated with 0≥ 10 EeV UHECR arrival directions at confidence level ≈ 90%. The strength of the correlation decreases with decreasing UHECR energy and no correlation exists at energy 0∼ 6 EeV . A search in astrophysical databases within 3{sup o} of the arrival directions of UHECRs with energy 0≥ 10 EeV, that are correlated with the IceCube cosmic neutrinos, resulted in 18 sources from the Swift-BAT X-ray catalog with redshift z≤ 0.06. We also found 3 objects in the Kühr catalog of radio sources using the same criteria. The sources are dominantly Seyfert galaxies with Cygnus A being the most prominent member. We calculate the required neutrino and UHECR fluxes to produce the observed correlated events, and estimate the corresponding neutrino luminosity (25 TeV–2.2 PeV) and cosmic-ray luminosity (500 TeV–180 EeV), assuming the sources are the ones we found in the Swift-BAT and Kühr catalogs. We compare these luminosities with the X-ray luminosity of the corresponding sources and discuss possibilities of accelerating protons to 0∼> 10 EeV and produce neutrinos in these sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Modelling the impact of host galaxy dust on type Ia supernova distance measurements

Type Ia Supernovae (SNe Ia) are a critical tool in measuring the accelerating expansion of the universe. Recent efforts to improve these standard candles have focused on incorporating the effects of dust on distance measurements with SNe Ia. In this paper, we use the state-of-the-art Dark Energy Survey 5 year sample to evaluate two different families of dust models: empirical extinction models derived from SNe Ia data and physical attenuation models from the spectra of galaxies. In this work, we use realistic simulations of SNe Ia to forward-model different models of dust and compare summary statistics in order to test different assumptions and impacts on SNe Ia data. Among the SNe Ia-derived models, we find that a logistic function of the total-to-selective extinction R V best recreates the correlations between supernova distance measurements and host galaxy properties, though an additional 0.02 mag of grey scatter is needed to fully explain the scatter in SNIa brightness in all cases. These empirically derived extinction distributions are highly incompatible with the physical attenuation models from galactic spectral measurements. From these results, we conclude that SNe Ia must either preferentially select extreme ends of galactic dust distributions, or that the characterization of dust along the SNe Ia line-of-sight is incompatible with that of galactic dust distributions.

79 ASTRONOMY AND ASTROPHYSICS↗