Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “technology modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Physics-informed machine learning for fault-leakage reduced-order modeling

Geologic carbon storage (GCS) is a promising technology for mitigating CO 2 emissions. The overall success of GCS depends on safe operations that are informed by risk assessment and have proper mitigation plans in place. Performing quantitative probabilistic risk assessment for a GCS site using traditional reservoir simulators can be challenging due to the high computational costs. To overcome this challenge, the US Department of Energy’s National Risk Assessment Partnership (NRAP) project has developed an integrated assessment modeling approach that utilizes computationally efficient reduced-order models (ROM) for simulating various parts of a GCS storage site to quantify uncertainty. Here, in this study, we develop a reduced-order model for fault leakage risk assessment. We use a deep learning approach to build the reduced-order model. We perform a sensitivity analysis and find that the deep learning model yields high accuracy with a much smaller computational cost than full-physics simulation. We also evaluate the performance of the model in scenarios where simulations are not possible to run, providing analysis not previously performed in fault-leakage ROM analyses. Based on a sensitivity analysis of the model, we suggest a simplified conceptual model for fault leakage and site monitoring.

58 GEOSCIENCES↗

Assessing the behavioral realism of energy system models in light of the consumer adoption literature

Effective policymaking to achieve net zero greenhouse gas emissions demands an understanding of the complex drivers of, and barriers to, consumer adoption behavior via behaviorally realistic energy system models. Existing models tend to oversimplify by focusing on homogenized financial factors while neglecting consumer heterogeneity and non-monetary influences. This study develops and applies a comprehensive framework for evaluating the behavioral realism of consumer adoption models, informed by the adoption literature. It introduces a typology for factors influencing low-carbon technology adoption decisions: monetary and non-monetary factors relating to household characteristics, psychology, technological attributes, and contextual conditions. Next, reviews of the consumer adoption and decision-making literature identify the most influential adoption factor categories for distributed solar photovoltaics, electric vehicles, and air-source heat pumps. Finally, the extent to which a selection of energy system models accounts for these adoption factors is assessed. Existing models predominantly emphasize the economic aspects of technology, which are generally identified as the most important factors. Where the models fall short — in considering moderately important factor categories — sector-specific and agent-based models can offer more behaviorally realistic insights. This study sheds light on which types of factors are most important for consumer adoption decisions and investigates how well current models rise to the challenge of behavioral realism. The end-to-end analysis presented enables internally consistent comparisons across models and energy technologies. This research advances timely conversations on consumer adoption. It could inform more behaviorally realistic energy system modeling, and thereby more effective decarbonization policymaking.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic assessment of emerging CO 2 electrolysis technologies

Recycling of waste CO 2 to bulk chemicals has a tremendous potential for the decarbonization of the chemical industry. Quantitative analysis of the prospects of this technology is hindered by the lack of flexible techno-economic assessment (TEA) models that enable evaluation of the processing costs under different deployment scenarios. In this protocol, we explain how to convert literature data into metrics useful for evaluation of the emerging electrolysis technologies, derive TEA models, and illustrate their use with a CO 2 -to-ethylene example. For complete details on the use and execution of this protocol, please refer to Barecka et al. (2021a).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preconceptual Designs of Coupled Power Delivery between a 4-Loop PWR and 100-500 MWe HTSE Plants

This study develops a preconceptual design for the integration between a large-scale high-temperature electrolysis facility and a NPP. Two hydrogen facility sizes are considered: 100 MWnom and 500 MWnom. Both steam supply designs use cold reheat steam extraction as a heat source. A reboiler inside the protected area of the power plant transfers steam heat to the demineralized water supply for the hydrogen plant. After the heat transfer, the extracted steam condenses and returns to the condenser while the process steam routes out of the protected area to the electrolyzers. Electrical power is tapped off from the high voltage side of the GSU transformer, where it is then transported via a 345-kV transmission line to the hydrogen facility. Circuit breakers and disconnects are located at both ends of the transmission line. Step down transformers and miscellaneous switchgear/buses are located at the end of the transmission line inside the HTEF boundary. Control capabilities for the steam interfacing equipment and electrical dispatch are accessible from the Main Control Room, and protective relays for the transmission line are located inside the Relay Room. Computer modeling was performed for the thermal and electrical designs. PEPSE analysis provided the steady-state parameters for thermal extraction from the turbine cycle. These parameters were used to inform transients and size equipment in combination with Applied Flow Technology (AFT) Arrow and AFT Fathom modeling for steam and water piping, respectively. Electrical transients were analyzed using PSCAD. An ETAP model was used to evaluate power flow and short circuit, which enabled the sizing of transformers and protective equipment. A cost estimate was developed for both integration designs when considering plant separation distances of 250 m and 500 m. From these estimates, the modifications for thermal and electrical interfacing of a first-of-a-kind nuclear-integrated hydrogen facility are anticipated to cost between $60–250/kWnom., where the subscript “nom” refers to the nominal size of the hydrogen plant. On a thermal power basis, the thermal power has a cost of approximately $8/MWth for a 500 MWnom high temperature electrolysis plant located 500 m distant from the NPP. That value decreases to approximately $7.5/MWth for a 250 m separation distance between the hydrogen plant and the NPP. This value is lower than previous estimates of the cost of heat extracted from NPPs primarily because in this work the steam is extracted from cold reheat instead of the main steam line, which reduces the cost of the dispatched steam by approximately $3.5/MWth. Nuclear steam extraction can provide a profit avenue for many plants and is not restricted to hydrogen production. Ammonia production, oil refining, and paper production, among other industrial processes all require thermal energy, which can be provided by NPPs. Future work should look further at the details of thermal extraction for a variety of use cases. This can include increased levels of extraction and multiple simultaneous users. Additionally, site-specific studies should be performed to develop industry experience and improve cost accuracy.

08 HYDROGEN↗

Integrated Data Analysis to Improve Te and Zeff Measurement on NSTX-U

The multi-energy soft x-ray (ME-SXR) camera is a new concept for a fusion plasma diagnostic based on a pixelated detector with adjustable photon cutoff thresholds. It is a single, compact, solid-state detector which combines spatial and spectral sensitivity and can be configured remotely at run time, making it ideal for a fusion environment. The detector can be configured for application to a wide range of physics problems including impurity transport, electron temperature profiles, and non-thermal effects. The detector has been installed on the Madison Symmetric Torus (MST) as part of a collaboration between Princeton Plasma Physics Laboratory and the University of Wisconsin–Madison to develop the technology and analysis techniques. A full diagnostic forward model of the ME-SXR diagnostic has been developed to enable analysis of the raw photon count data. This model incorporates the atomic physics underlying the plasma emission, diagnostic geometry, and detector response characteristics. Employing this model, a Bayesian analysis approach is used to extract electron temperature from the raw data. This analysis approach uses all available information, clearly quantifies prior information, and handles uncertainties transparently. The ME-SXR camera is being used to study the 3D (helical, stellarator-like) state that forms in the MST device. This helical core structure has improved energy confinement. The transition to the helical state is accompanied by a rise in electron temperature in the central part of the helical structure, but then this enhancement fluctuates. The characteristics of this fluctuation are being compared to a magneto-hydrodynamics model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Simulation Modeling Approach to Optimizing Nuclear Waste Dispositioning

The dispositioning of nuclear waste generated at facilities across the country is an ongoing battle that affects us all. National laboratories and research centers dealing in medical research, clean energy, and other nuclear activities such as the Department of Energy (DOE) facilities face the need to properly manage and dispose of nuclear waste. A dynamic modeling solution would enable the DOE and others to make decisions on waste disposal and technological options. In doing so, this research explores modeling techniques using available data to address these situations. The focus being on developing an initial robust and adaptable discrete event model using the ExtendSim tool. This modeling effort will target the dispositioning of transuranic waste at the Savannah River National Laboratory (SRNL) which can be expanded to represent the current state of disposition process for waste generated at other DOE facilities. The model aims to assess resource allocation and waste processing options to stabilize productivity and cut the backlog of nuclear waste. By assessing the results of different scenarios, this research aims to provide actionable insights for the DOE. This approach has the potential to significantly improve the management of radioactive waste, offering the capability of evaluating options for optimizing the process for nuclear waste disposal. The findings of this study can serve as a valuable resource for decision-makers and other national laboratories, or research entities engaged in nuclear operations by enabling them to make more informed choices.

Andaverde, Alexis↗

The Use of Machine Learning Models for Predicting the Dielectric Strength of Gases

Technological advancements in high voltage systems have pushed sulfur hexafluoride (SF6) to its operational limits. Furthermore, this gas has other drawbacks including a high liquefaction temperature and a high global warming potential. Therefore, there has been an urgent need to find alternative gases with high dielectric strength (DS). In this work, density functional theory (DFT) is used to calculate molecular descriptors that are fed into an artificial neural network (ANN) and a random forest (RF). These machine learning (ML) models are then used to predict the DS for hundreds of molecules. A finite element model (FEM) is also used to calculate the electric field profile of multiple simple electrode geometries as the applied voltage to the system is increased. Results indicate that the random forest model has better generalization to unseen data than the neural network. The highest DS value predicted by the RF was 2.16 relative to the experimental DS of SF6. The results also demonstrate how choosing a gas with a higher DS and a geometry with minimal edges and corners can significantly increase the operating voltage of an electrical system. Due to its superior generalization, the RF represents the most promising path toward an accurate DS predictor once sufficient experimental data are available.

Mileski, Matthew [AFIT]↗

BSM (Bioenergy Scenario Model) 2023 FKA: Biomass Scenario Model [SWR-09-09]

The U.S. Department of Energy's (DOE's) Bioenergy Technologies Office and the National Renewable Energy Laboratory (NREL) developed the BSM (Bioenergy Scenario model) to explore the development of a U.S. biofuels industry. The BSM is a system dynamics model built on the STELLA software platform. The model represents the dynamic interactions of the major sectors of the biofuels industry—feedstock production, feedstock logistics, biomass to biofuels conversion, and biofuels end use, including fuels inventory, dispensing, distribution, fuel use, and the vehicle fleet. The BSM represents contextual aspects of the developing biofuels industry, including investment in new biomass to biofuel conversion technologies, competition from petroleum fuels, vehicle demand for biofuels, and various government policies, using all of these to simulate the development of the industry. The purpose of the BSM is to generate and explore plausible scenarios for the evolution of a biofuels industry in the United States, and as a high-level system model it is not designed for precise, quantitative forecasting. Instead, it is best used to (1) analyze and evaluate alternate policies; (2) generate scenarios; (3) identify high-impact levers and bottlenecks to system evolution; and (4) seed focused discussion among policymakers, analysts, and stakeholders.

Bush, Brian↗

Prevention of resistive wall tearing mode major disruptions with feedback

Resistive wall tearing modes (RWTMs) can cause major disruptions. A signature of RWTMs is that the rational surface is sufficiently close to the wall to interact with it. For (m,n) = (2,1) modes, a RWTM requires normalized minor radius of the rational surface ρ q2 ≥ 0.75, which can also be expressed as q 75 ≤ 2. Major disruptions can occur when the criterion is satisfied. This is confirmed in simulations and theory and in a DIII-D locked mode disruption database. The q 75 < 2 criterion is valid at high β as well as at low β. A very important feature of RWTMs is that they can be feedback stabilized. If the ρ q2 criterion is not satisfied, or if the wall is ideally conducting, then the mode does not produce a major disruption, although it can produce a minor disruption. Feedback, or rotation of the mode at the wall by complex feedback, can emulate an ideal wall, preventing major disruptions. The ρ q2 criterion depends weakly on the wall radius. A simple geometric model of its dependence on wall radius is given.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Canadian Oil Sands Extraction and Upgrading: A Synthesis of the Data on Energy Consumption, CO 2 Emissions, and Supply Costs

As Canadian crude bitumen production from oil sands has increased in recent decades, the nation’s oil and gas industry has become a significant contributor to national greenhouse gas emissions. Canada has developed carbon emission reduction targets to meet its Nationally Determined Contributions and Mid-Century Strategy goals. A detailed profile of energy consumption pathways in the oil sands industry is necessary to identify potential areas of improvement and to monitor progress toward meeting emissions reduction targets. Much of the existing literature for oil sands modeling provides input assumptions with different technological boundaries. For a set of oil sands extraction and upgrading technologies, this study first reviews the literature and then quantifies energy input requirements, CO 2 emissions, and operating costs for a set of consistent technological boundaries and energy units. Summary results refer to requirements and costs at the production facility, excluding transportation and blending costs. An energy system diagram of oil sands production that matches these boundaries is provided, which can be used by integrated assessment models, oil sands companies, and government ministries to evaluate the present and future energy consumption and emissions pathways of the oil sands industry.

02 PETROLEUM↗

Fleet-Level Energy and Emissions Analysis of the US Off-Road Sector with VISION: Off-Road

In the United States (US), the off-road sector (i.e., agriculture, construction, etc.) contributes to approximately 10% of the country’s transportation greenhouse gas (GHG) emissions, similar to the aviation sector. The off-road sector is extremely diverse; as the EPA MOVES model classifies it into 11 sub-sectors, which include 85 different types of equipment. These equipment types have horsepower ranging from 1 to greater than 3000 and have very different utilization, which makes decarbonization a complex endeavor. To address this, Argonne’s on-road vehicle fleet model, VISION, has been expanded to the off-road sector. The GHG emission factors for several energy carriers (biofuels, electricity, and hydrogen) have been incorporated from Argonne’s GREET model for a sector-wide well-to-wheel (WTW) GHG emissions analysis of the present and future fleet. Several technology adoption and energy decarbonization scenarios were modeled to better understand the appropriate actions required to drive towards net-zero emissions of the off-road sector. Results show that WTW decarbonization up to 67% can be achieved from 2023 to 2050 in a business-as-usual scenario. But with aggressive sales increases of electric and hydrogen powertrains, WTW decarbonization up to 77% can be achieved, which can further increase to 85% if electricity production is aggressively decarbonized by 2035.

lifecycle↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Evaluating the potential of plastic waste upcycling using thermochemical technologies: A case study in Spain

A plastic waste upcycling value chain model has been applied to assess the potential of processing packaging waste in Spain using thermo-chemical technologies to produce low-density polyethylene (LDPE) and polypropylene (PP), which are highly valuable materials. The model projects an annual profit of 120.6 M$\$$/yr, with a capital investment of 789.3 M$\$$, generating 3285 jobs and contributing 65.5 M$\$$/yr to Spain’s economy. The achieved circularity rate of the waste processing infrastructure exceeds 40 %, incorporating recycled HDPE and PET. Despite these advantages, regulatory gaps and market hesitancy toward recycled materials due to quality concerns hinder adoption. Additionally, economies of scale remain underutilized in Spain due to lower plastic waste collection levels compared to countries such as the United States. This network, while less profitable, is environmentally superior, yielding upcycled products with a Global Warming Potential 20–35 % lower than their virgin, fossil-fuel counterparts, confirming this as a viable and sustainable alternative.

Chemical upcycling↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Review of internal cyber attacks in nuclear facilities and an artificial neural network model for implementing internal cyberforensics

Deployment of digital technologies within a modern shift in cyber defense systems is essential for protecting the energy production units. One of the important components of defense is cyberforensics: once an attack has been detected to locate its origin. In this paper, a review of well-known cyberattacks in nuclear facilities is provided, with the lessons learned leading to the development of a machine learning approach implementing identification of internal at- tacks in the facility's data networks. Our approach may be seen as one of the layers in a defense-in-depth strategy that identifies if the attack comes from inside, which may result in identifying faster the attacker's origin. The presented model exploits network packet examination to cast accurate predictions on detailing the origin of malicious network connections. The approach fuses multiple mathematical functions within an artificial neural network to provide a response in the form of 0/1, i. e., whether the attack is identified as internal or not. The utilization of a variety of test cases is developed to explore the relevance and validity of the predictive approach. The proposed implementation is examined with network data packet variance, and the results obtained exhibit a highly accurate detection rate.

Nuclear Science & Technology↗

Interplay of changing irrigation technologies and water reuse: example from the upper Snake River basin, Idaho, USA

Abstract. Careful allotment of water resources for irrigation is critical for ensuring the resiliency of agriculture in semiarid regions, and modernizing irrigation technology to minimize inefficient water losses is an important tool for farmers and agricultural economies. While modernizing irrigation technology can achieve reductions in the nonbeneficial use of water, such as bare soil evaporation and nonconsumptive losses, water returned to the landscape is also reduced, often eliminating flow paths that other users rely on. In basins using a combination of surface and groundwater, replenishing aquifer storage by the managed aquifer recharge (MAR) of seasonally available water can mitigate the aquifer drawdown that results from reduced recharge when irrigation efficiency is improved. We examine the effects of MAR on the system-scale efficiency of modernizing irrigation technology and the resulting changes in the reuse of nonconsumptive losses, using a macroscale hydrologic model applied to the semiarid upper Snake River basin (USRB) of western Wyoming and southern Idaho, USA. Irrigation technologies were represented explicitly in the model, and available data informed baseline parameterizations of the irrigation technology. A suite of parameterizations were simulated that updated the existing technologies to be more efficient, both with and without sufficient MAR to cause a stabilization of the aquifer at the present-day head. As expected, simulated changes in irrigation technology resulted in greater downstream export of pristine water and a higher rate of aquifer drawdown when MAR was not simulated. Under current water use and cropping patterns, we were not able to simulate aquifer stabilization and maintain discharge downstream at any level of irrigation efficiency. We found support for the hypothesis that, as efficiency improves, less MAR is required to maintain a stable aquifer than when return flows are reduced due to increased efficiency. To evaluate the hypothesis, we defined the management benefit as a metric that compared the difference between the change in irrigation's net recharge and the change in MAR required as irrigation technology became more efficient. The metric generally indicated that less MAR was needed than net recharge was lost, but only for the most efficient case did the management benefit exceed the MAR needed at the baseline to stabilize the aquifer. Increasing efficiency of irrigation technology reduced the reuse of the gross irrigation derived from prior nonconsumptive losses, but simulating MAR increased reuse for a given parameterization, leading to higher effective irrigation efficiency. We find that local groundwater storage that users depend on is generally more sensitive to management decisions than downstream flows, and the drawdown of the aquifer without MAR always exceeded any decrease in discharge induced by MAR. Improving resource sufficiency in semiarid systems like the USRB will require an array of solutions that will need to balance benefits to local and downstream users.

54 ENVIRONMENTAL SCIENCES↗

Comparative techno-economic analysis of synthetic renewable natural gas production via reactive CO 2 capture and conversion

Reactive CO 2 capture and conversion (RCC) is an emerging carbon management strategy that integrates CO 2 capture and conversion and avoids intermediate CO 2 purification. In this study, we design an RCC process to capture atmospheric CO 2 and react it with renewable hydrogen to produce synthetic renewable natural gas (SRNG), which serves as a carbon-neutral energy source and a chemical form of long-duration renewable energy storage. We assess the technological potential of RCC through process modeling, techno-economic, carbon footprint, and sensitivity analyses. Our findings demonstrate that RCC offers energy savings and comparable cost to separated capture and conversion processes. The cost is dominated by renewable hydrogen and material replacement cost. SRNG produced via RCC is competitive with existing low-carbon natural gas technologies and presents a promising low-cost option for long-duration energy storage. This work highlights the potential for deploying RCC technologies within a circular carbon economy and the scientific and technical challenges that must be overcome for material and technology developers.

03 NATURAL GAS↗