Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “techniques: image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Non-Destructive Monitoring of Charge-Discharge Cycles on Lithium Ion Batteries using 7 Li Stray-Field Imaging

Magnetic resonance imaging provides a noninvasive method for in situ monitoring of electrochemical processes involved in charge/discharge cycling of batteries. Determining how the electrochemical processes become irreversible, ultimately resulting in degraded battery performance, will aid in developing new battery materials and designing better batteries. Here we introduce the use of an alternative in situ diagnostic tool to monitor the electrochemical processes. Utilizing a very large field-gradient in the fringe field of a magnet, stray-field-imaging (STRAFI) technique significantly improves the image resolution. These STRAFI images enable the real time monitoring of the electrodes at a micron level. It is demonstrated by two prototype half-cells, graphite ∥Li and LiFePO 4 ∥ Li, that the high-resolution 7 Li STRAFI profiles allow one to visualize in situ Li-ions transfer between the electrodes during charge/discharge cyclings as well as the formation and changes of irreversible microstructures of the Li components, and particularly reveal a non-uniform Li-ion distribution in the graphite.

25 ENERGY STORAGE↗

Predissociation and dissociative ionization of Rydberg states of Xe{sub 2} and the photodissociation of Xe{sub 2}{sup +}.

The Rydberg states of Xe{sub 2} in the region between 76,,000 and 84,000 cm{sup -1} were studied by using a combination of two-photon excitation and velocity map ion imaging. The electronic states in this region are based on the Xe({sup 1}S{sub 0})+Xe 6p and 5d dissociation limits, and the large number of states leads to numerous curve crossings and distorted potentials. These Rydberg states can decay by predissociation or fluorescence or can be photoionized, dissociatively photoionized, or photodissociated by the absorption of a single additional photon. Furthermore, the molecular ion can be photodissociated as well. While numerous other techniques have been applied to this problem, velocity map ion imaging provides a high resolution approach to determine the operative processes. When combined with existing data obtained by other methods, the present experiments allow a more complete understanding of the assignment and behavior of these states.

74 ATOMIC AND MOLECULAR PHYSICS↗

Saturn's magnetosphere: An example of dynamic planetary systems

Planetary magnetospheres are prime examples of interacting plasma regimes at different scales. There is the principal interaction with the solar wind that seems to be the main driver of the dynamics at Mercury and Earth. But these inner planet magnetospheres are relatively simple when compared to those of the outer planets which are primarily driven by planetary rotation and include internal plasma sources from various moons and rings, in addition to those from the planetary ionospheres and the solar wind. Io's volcanic source at Jupiter is a prime example, but now Enceladus at Saturn has joined the fray, while Titan is a surprisingly minor player despite its thick nitrogen atmosphere and its continued bombardment by energetic particles. Mass loading of plasma leads to interchange instability in the inner magnetospheres at both Jupiter and Saturn, while ionospheric slippage, among other processes, seems to contribute to a variable rotation period in the spin-aligned dipole field of Saturn, manifested in auroral kilometric radiation (SKR), components of the magnetic field itself, and the plasma periodicities measured at several energies. Through use of the ENA (energetic neutral atom) technique, it is now possible to observe bulk motions of the plasma and their connection to planetary auroral processes. Such imaging at Saturn by Cassini has revealed the location of a region of post-midnight acceleration events that seem to corotate with the planet and coincide with auroral brightening and SKR. Periodic injections of plasma have been identified and repeat at the Kronian rotation period of 10.8 hours. A semi-permanent but asymmetric ring current has also been imaged, located between the orbits of the satellites Rhea ({approx}9 RS) and Titan ({approx}20 R{sub S}), with a maximum at {approx}10{+-} 1R{sub S} and dominated by the hot (>3 keV) plasma component.

79 ASTRONOMY AND ASTROPHYSICS↗

Small Unilamellar Vesicles: A Platform Technology for Molecular Imaging of Brain Tumors

Molecular imaging enables the non-invasive investigation of cellular and molecular processes. Although there are challenges to overcome, the development of targeted contrast agents to increase the sensitivity of molecular imaging techniques is essential for their clinical translation. In this study, spontaneously forming, small unilamellar vesicles (sULVs) (30 nm diameter) were used as a platform to build a bimodal (i.e., optical and magnetic resonance imaging (MRI)) targeted contrast agent for the molecular imaging of brain tumors. sULVs were loaded with a gadolinium (Gd) chelated lipid (Gd-DPTA-BOA), functionalized with targeting antibodies (anti-EGFR monoclonal and anti-IGFBP7 single domain), and incorporated a near infrared dye (Cy5.5). The resultant sULVs were characterized in vitro using small angle neutron scattering (SANS), phantom MRI and dynamic light scattering (DLS). Antibody targeted and nontargeted Gd loaded sULVs labeled with Cy5.5 were assessed in vivo in a brain tumor model in mice using time domain optical imaging and MRI. The results demonstrated that a spontaneously forming, nanosized ULVs loaded with a high payload of Gd can selectively target and image, using MR and optical imaging, brain tumor vessels when functionalized with anti-IGFBP7 single domain antibodies. The unique features of these targeted sULVs make them promising molecular MRI contrast agents.

60 APPLIED LIFE SCIENCES↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extraction of Vibration Data with Imaging

To date, the primary sensing technology used to measure the vibration response has been accelerometers and strain gages mounted directly to the structure and using either wired or, more recently, wireless telemetry. Cost issues with these sensors and the associated data acquisition systems typically limit the numbers that are deployed on in situ structures. Although there are a few structures with larger sensing counts that in some cases exceed over 1000 sensors, more typical numbers range from ten to one hundred sensors resulting in low spatial resolution when they are applied to physically large systems. When one considers that nuclear power plant structures usually have complex geometries, material properties, connectivity and boundary conditions, it is clear these current approaches to vibration measurements can only provide limited information about a system’s dynamics response characteristics. As an alternative, many non-contact measurement technologies have emerged, including point wise measurement methods such as Global Positioning System (GPS), microwave interferometry, and laser Doppler vibrometry (LDV), as well as simultaneous full-field measurement methods such as electronic speckle pattern interferometry, holography interferometry, and muon tomography, some of which can provide high spatial resolution measurements. Among these methods, digital video imaging techniques have emerged as a feasible solution for full-field vibration measurements that provide significantly more detailed dynamic response information because every pixel becomes a measurement point. Furthermore, recent advances in image processing and computer vision algorithms have been successfully used to process video data for experimental and operational modal analysis. Such full-field measurements have the potential to significantly improve many current structural assessment procedures including system identification (modal parameter estimation), structural health monitoring, load reconstruction, model validation, and model updating. Furthermore, more recent full-field imaging techniques can be accomplished with relatively low-cost, commercially-available off-the-shelf cameras. However, these measurement procedures have other limitations that must be considered such as the ability to only measure visibly accessible points on a structure and a more limited dynamic range and bandwidth than can be achieved with accelerometers or strain gages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Behavior of an MBT waste in monotonic triaxial shear tests

Highlights: ► We studied the stress–strain–strength characteristics of an MBT waste. ► Rate of mobilization of strength with strain depends on initial density. ► Image analysis technique was used to determine whole-specimen displacement fields. ► Initial mode of deformation of a loose specimen is one-dimensional compression. ► Reinforcing elements enhance the resistance to lateral and volumetric deformation. - Abstract: Legislation in some parts of the world now requires municipal solid waste (MSW) to be processed prior to landfilling to reduce its biodegradability and hence its polluting potential through leachate and fugitive emission of greenhouse gases. This pre-processing may be achieved through what is generically termed mechanical–biological-treatment (MBT). One of the major concerns relating to MBT wastes is that the strength of the material may be less than for raw MSW, owing to the removal of sheet, stick and string-like reinforcing elements during processing. Also, the gradual increase in mobilized strength over strains of 30% or so commonly associated with unprocessed municipal solid waste may not occur with treated wastes. This paper describes a series of triaxial tests carried out to investigate the stress–strain–strength characteristics of an MBT waste, using a novel digital image analysis technique for the determination of detailed displacement fields over the whole specimen. New insights gained into the mechanical behavior of MBT waste include the effect of density on the stress–strain response, the initial 1-D compression of lightly consolidated specimens, and the likely reinforcing effect of small sheet like particles remaining in the waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

COnfirmation using Gamma-ray Non-Imaging Zero-knowledge ANti-mask Time-encoding (COGNIZANT) Final Summary Report

In potential future arms reduction treaties in which the numbers of nuclear warheads may approach small numbers, using delivery systems as a proxy for the warheads themselves may be insufficient. Therefore, a technical means of verifying the presence of a nuclear warhead may become necessary. Verifying that a declared item actually is a warhead is technically challenging within a verification regime: providing assurance to the monitoring party that a presented item is a warhead while protecting sensitive information about that warhead may be required. It is generally believed that strong assurance will require the confirmation of key attributes that may reveal closely-guarded critical design information. This provides high confidence to the monitoring party, but presents a risk of information loss to the host. A verification system must overcome this hurdle. Over the last several decades, systems have been developed that balance host and monitoring partner needs by using sensitive information to confirm treaty accountable items (TAI) as warheads while sequestering that information behind an information barrier (1). These are designed to meet the needs of the host but places the onus on the monitor to authenticate the hardware, firmware, and software. Authentication requires that the monitor confirm that all components of the system have not been modified and work as intended. In 2014, Glaser et al. proposed applying the concept of “zero knowledge protocols” (ZKP) from the field of cryptography to the problem of warhead verification (2). In mathematical cryptography, ZKP is accomplished by challenging one party to solve a problem that is only possible if that party possesses the information being authenticated. After repeated challenges, the party provides confidence that it possesses this information without revealing any details about the information itself. Systems have been in development based on this idea at both Princeton and MIT (2) (3) (4). The final measurement results produced by these systems can be viewed by both the host and the monitoring party without the worry of revealing sensitive information. However, in both of these physical implementations, there remains an information barrier within the system. The need for a digital information barrier to protect a measurement result is eliminated, but it has been replaced with the need to sequester physical components of the system, potentially obfuscating the measurement process itself. Both implementations physically insert information into the system that requires protection to prevent undesired disclosure of sensitive information: in the Princeton method, one must physically load the complement of the expected image of a true warhead into the system, and in the MIT technique, one loads a collection of spectator foils whose thicknesses physically encrypt a measured spectrum. This complicates authentication of the hardware and measurement process. The CONFIDANTE/COGNIZANT concept developed in this project do not load sensitive information into the system at any time, and could therefore open the possibility of allowing the inspector to not only view the final data but also the measurement as it is being performed and all associated equipment.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

SHARP: a distributed GPU-based ptychographic solver

Ever brighter light sources, fast parallel detectors and advances in phase retrieval methods have made ptychography a practical and popular imaging technique. Compared to previous techniques, ptychography provides superior robustness and resolution at the expense of more advanced and time-consuming data analysis. Therefore, by taking advantage of massively parallel architectures, high-throughput processing can expedite this analysis and provide microscopists with immediate feedback. These advances allow real-time imaging at wavelength-limited resolution, coupled with a large field of view. This article describes a set of algorithmic and computational methodologies used at the Advanced Light Source and US Department of Energy light sources. These are packaged as a CUDA-based software environment named SHARP, aimed at providing state-of-the-art high-throughput ptychography reconstructions for the coming era of diffraction-limited light sources.

47 OTHER INSTRUMENTATION↗

Generalized Quantum Convolution for Multidimensional Data

The convolution operation plays a vital role in a wide range of critical algorithms across various domains, such as digital image processing, convolutional neural networks, and quantum machine learning. In existing implementations, particularly in quantum neural networks, convolution operations are usually approximated by the application of filters with data strides that are equal to the filter window sizes. One challenge with these implementations is preserving the spatial and temporal localities of the input features, specifically for data with higher dimensions. In addition, the deep circuits required to perform quantum convolution with a unity stride, especially for multidimensional data, increase the risk of violating decoherence constraints. In this work, we propose depth-optimized circuits for performing generalized multidimensional quantum convolution operations with unity stride targeting applications that process data with high dimensions, such as hyperspectral imagery and remote sensing. We experimentally evaluate and demonstrate the applicability of the proposed techniques by using real-world, high-resolution, multidimensional image data on a state-of-the-art quantum simulator from IBM Quantum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Physics-Informed and Data-Driven Prediction of Residual Stress in Three-Dimensional Machining

Efficient and reliable prediction of machining-induced residual stress (RS) is a key requirement for truly integrated computational materials engineering (ICME). Currently available process modeling approaches, including empirical, analytical, and numerical methodologies lack predictive power and require substantial calibration and validation data. Moreover, most model-based approaches consider only two-dimensional (2D) (i.e., orthogonal), cutting processes. Meanwhile, industrial processes such as milling, turning, and drilling are inherently three-dimensional (3D). The present work attempts to bridge the gap between 2D and 3D through careful consideration of the process physics, including geometric, kinematic, and size-effect constraints to realize robust prediction of how RS develops in 3D machining. Using a novel in-situ experimental technique and digital image correlation (DIC) to determine equivalent Hertzian contact widths, contact pressures, and friction coefficients, the proposed methodology leverages a discretized conversion algorithm that includes multi-pass shakedown effects. This paper presents a semi-analytical model to predict machining-induced RS in 3D turning operations, which are used representatively for 3D processes more generally. Rather than follow a ‘brute force’ 3D FEM approach or conduct countless experiments to train a purely data-driven machine learning algorithm, the proposed approach builds on previous 2D modeling work. Through careful consideration of the process physics, including complex geometry/kinematic considerations of 3D turning, the authors demonstrated an experimentally calibrated approach, as well as validation based on published RS data. Model predictions and previously published measurement data of RS depth profiles for turning of Inconel 718 were compared for a range of process parameters. Correlation between the proposed 3D model and validation data was found to be within the margin of experimental error for most conditions. The proposed model appears to capture the overall behavior of 3D RS depth profiles with acceptable accuracy, particularly the key metrics of near-surface stress, peak stress magnitude and location, as well as overall stress profile depth. This report presents a physics-informed, data-driven approach for efficient calibration of a 2D model for machining-induced RS through DIC analysis of in-situ characterized subsurface displacement fields.

42 ENGINEERING↗

TH-E-9A-01: Medical Physics 1.0 to 2.0, Session 4: Computed Tomography, Ultrasound and Nuclear Medicine

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. CT 2.0: CT has been undergoing a dramatic transition in the last few decades. While the changes in the technology merits discussions of their own, an important question is how clinical medical physicists are expected to effectively engage with the new realities of CT technology and practice. Consistent with the upcoming paradigm of Medical Physics 2.0, this CT presentation aims to provide definitions and demonstration of the components of the new clinical medical physics practice pertaining CT. The topics covered include physics metrics and analytics that aim to provide higher order clinicallyrelevant quantification of system performance as pertains to new (and not so new) technologies. That will include the new radiation and dose metrics (SSDE, organ dose, risk indices), image quality metrology (MTF/NPS/d’), task-based phantoms, and the effect of patient size. That will follow with a discussion of the testing implication of new CT hardware (detectors, tubes), acquisition methods (innovative helical geometries, AEC, wide beam CT, dual energy, inverse geometry, application specialties), and image processing and analysis (iterative reconstructions, quantitative CT, advanced renditions). The presentation will conclude with a discussion of clinical and operational aspects of Medical Physics 2.0 including training and communication, use optimization (dose and technique factors), automated analysis and data management (automated QC methods, protocol tracking, dose monitoring, issue tracking), and meaningful QC considerations. US 2.0: Ultrasound imaging is evolving at a rapid pace, adding new imaging functions and modes that continue to enhance its clinical utility and benefits to patients. The ultrasound talk will look ahead 10–15 years and consider how medical physicists can bring maximal value to the clinical ultrasound practices of the future. The roles of physics in accreditation and regulatory compliance, image quality and exam optimization, clinical innovation, and education of staff and trainees will all be considered. A detailed examination of expected technology evolution and impact on image quality metrics will be presented. Clinical implementation of comprehensive physics services will also be discussed. Nuclear Medicine 2.0: Although the basic science of nuclear imaging has remained relatively unchanged since its inception, advances in instrumentation continue to advance the field into new territories. With a great number of these advances occurring over the past decade, the role and testing strategies of clinical nuclear medicine physicists must evolve in parallel. The Nuclear Medicine 2.0 presentation is designed to highlight some of the recent advances from a clinical medical physicist perspective and provide ideas and motivation for designing better evaluation strategies. Topics include improvement of traditional physics metrics and analytics, testing implications of hybrid imaging and advanced detector technologies, and strategies for effective implementation into the clinic. Learning Objectives: Become familiar with new physics metrics and analytics in nuclear medicine, CT, and ultrasound. To become familiar with the major new developments of clinical physics support. To understand the physics testing implications of new technologies, hardware, software, and applications. Identify approaches for implementing comprehensive medical physics services in future imaging practices.

60 APPLIED LIFE SCIENCES↗

Removing imaging systematics from galaxy clustering measurements with Obiwan: application to the SDSS-IV extended Baryon Oscillation Spectroscopic Survey emission-line galaxy sample

This article presents the application of a new tool, Obiwan, which uses image simulations to determine the selection function of a galaxy redshift survey and calculate three-dimensional (3D) clustering statistics. Obiwan relies on a forward model of the process by which images of the night sky are transformed into a 3D large-scale structure catalogue, and offers several advantages over more traditional map-based techniques – such as operating on individual exposures and adopting a maximum likelihood approach. The photometric pipeline automatically detects and models galaxies and then generates a catalogue of such galaxies with detailed information for each one of them, including their location, redshift, and so on. Systematic biases in the imaging data are therefore imparted into the catalogues and must be accounted for in any scientific analysis of their information content. Obiwan simulates this process for samples selected from the Legacy Surveys imaging data. This imaging data will be used to select target samples for the next-generation Dark Energy Spectroscopic Instrument (DESI) experiment. Here, we apply Obiwan to a portion of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey emission-line galaxies (ELGs). Systematic biases in the data are clearly identified and removed. We compare the 3D clustering results to those obtained by the map-based approach applied to the complete eBOSS Data Release 16 (DR16) sample. We find the results are consistent, thereby validating the eBOSS DR16 ELG catalogues, which is used to obtain cosmological results.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies of the physical aspects of intumescence using advance diagnostics methods

The use of intumescent paints as an active fire protection method has gained immense interest in recent years. A significant aspect of research has focused on studying the chemical aspects of the system to improve performance. The dynamics and physical aspects of intumescence in real time fire conditions are still unclear. The present research uses an experimental approach where diagnostics techniques such as thermal imaging camera was used to study intumescent characteristics that have been not been reported in great detail. T-panels are a substitute to the most commonly used part in construction, the I-beam. Studies were conducted using a cone calorimeter that provided a uniform heat flux through radiation on steel T-panel samples. The complex nature of char movement was recorded and a novel algorithm was used to track the growing char laye07r. The samples are designed to cater to different fire conditions. Therefore, the degree of intumescence was observed to be very different in the samples. The samples designed for low temperature cellulosic fires focus on high degree of intumesce. Whereas, mechanical strength is the focus for samples used in high temperature turbulent hydrocarbon fire conditions. The variation in the internal structure of the sample is presented. Furthermore, the phenomenon is phase shift is discussed. The phase shift is an essential part of the process of intumescence when the majority of intumescence occurs. It was observed to be different in all the samples. The movement of the samples is a property of great interest. This is because if any part of the substrate is exposed then the formulation does not meet strict commercialisation criterion. The movement was diagonal in nature as compared to flat panels where it is perpendicular. This is due tot the heating pattern of the plate that results in the web part of the panel to influence the growth of char on the flange part of the panel. A special case of char cracking is also highlighted and using image processing algorithm on the thermal imaging data. A quantitative method of analsysis is presented to an otherwise commonly qualitative nature of experimental study in this field.

36 MATERIALS SCIENCE↗

Processing of X-ray snapshots from crystals in random orientations

A new method for the treatment of partial reflections from X-ray snapshots is implemented in the program package nXDS, which yields intensity data of almost the same quality as those obtained by the classical rotation method. A functional expression is introduced that relates scattered X-ray intensities from a still or a rotation snapshot to the corresponding structure-factor amplitudes. The new approach was implemented in the program nXDS for processing monochromatic diffraction images recorded by a multi-segment detector where each exposure could come from a different crystal. For images containing indexable spots, the intensities of the expected reflections and their variances are obtained by profile fitting after mapping the contributing pixel contents to the Ewald sphere. The varying intensity decline owing to the angular distance of the reflection from the surface of the Ewald sphere is estimated using a Gaussian rocking curve. This decline is dubbed ‘Ewald offset correction’, which is well defined even for still images. Together with an image-scaling factor and other corrections, an explicit expression is defined that predicts each recorded intensity from its corresponding structure-factor amplitude. All diffraction parameters, scaling and correction factors are improved by post-refinement. The ambiguous case of a lower point group than the lattice symmetry is resolved by a method reminiscent of the technique of ‘selective breeding’. It selects the indexing alternative for each image that yields, on average, the highest correlation with intensities from all other images. Processing a test set of rotation images by XDS and treating the same images by nXDS as snapshots of crystals in random orientations yields data of comparable quality, clearly indicating an anomalous signal from Se atoms.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correlating results from high resolution EBSD with TEM- and ECCI-based dislocation microscopy: Approaching single dislocation sensitivity via noise reduction

High resolution electron backscatter diffraction (HREBSD), an SEM-based diffraction technique, may be used to measure the lattice distortion of a crystalline material and to infer the geometrically necessary dislocation content. Uncertainty in the image correlation process used to compare diffraction patterns leads to an uneven distribution of measurement noise in terms of the lattice distortion, which results in erroneous identification of dislocation type and density. This work presents a method of reducing noise in HREBSD dislocation measurements by removing the effect of the most problematic components of the measured distortion. The method is then validated by comparing with TEM analysis of dislocation pile-ups near a twin boundary in austenitic stainless steel and with ECCI analysis near a nano-indentation on a tantalum oligocrystal. Finally, the HREBSD dislocation microscopy technique is able to resolve individual dislocations visible in TEM and ECCI and correctly identify their Burgers vectors.

36 MATERIALS SCIENCE↗

Fast X-ray imaging of cavitating flows

A new method based on ultra-fast X-ray imaging was developed in this work for simultaneous investigations of the dynamics and the structures of complex two-phase flows. Here in this paper, cavitation was created inside a millimetric 2D Venturi-type test section, while seeding particles were injected into the flow. Thanks to the phase-contrast enhancement technique provided by the APS (Advanced Photon Source) synchrotron beam, high definition X-ray images of the complex cavitating flows were obtained. These images contain valuable information about both the liquid and the gaseous phases. By means of image processing, the two phases were separated, and velocity fields of each phase were therefore calculated using image cross-correlations. The local vapour volume fractions were also obtained thanks to the local intensity levels within the recorded images. These simultaneous measurements, provided by this new technique, afford more insight into the structure and the dynamic of two-phase flows as well as the interactions between then, and hence enable to improve our understanding of their behavior. In the case of cavitating flows inside a Venturi-type test section, the X-ray measurements demonstrates, for the first time, the presence of significant slip velocities between the phases within sheet cavities for both steady and unsteady flow configurations.

47 OTHER INSTRUMENTATION↗

Image Hashes as Templates for Verification

Imaging systems can provide measurements that confidently assess characteristics of nuclear weapons and dismantled weapon components, and such assessment will be needed in future verification for arms control. Yet imaging is often viewed as too intrusive, raising concern about the ability to protect sensitive information. In particular, the prospect of using image-based templates for verifying the presence or absence of a warhead, or of the declared configuration of fissile material in storage, may be rejected out-of-hand as being too vulnerable to violation of information barrier (IB) principles. Development of a rigorous approach for generating and comparing reduced-information templates from images, and assessing the security, sensitivity, and robustness of verification using such templates, are needed to address these concerns. We discuss our efforts to develop such a rigorous approach based on a combination of image-feature extraction and encryption-utilizing hash functions to confirm proffered declarations, providing strong classified data security while maintaining high confidence for verification. The proposed work is focused on developing secure, robust, tamper-sensitive and automatic techniques that may enable the comparison of non-sensitive hashed image data outside an IB. It is rooted in research on so-called perceptual hash functions for image comparison, at the interface of signal/image processing, pattern recognition, cryptography, and information theory. Such perceptual or robust image hashing—which, strictly speaking, is not truly cryptographic hashing—has extensive application in content authentication and information retrieval, database search, and security assurance. Applying and extending the principles of perceptual hashing to imaging for arms control, we propose techniques that are sensitive to altering, forging and tampering of the imaged object yet robust and tolerant to content-preserving image distortions and noise. Ensuring that the information contained in the hashed image data (available out-of-IB) cannot be used to extract sensitive information about the imaged object is of primary concern. Thus the techniques are characterized by high unpredictability to guarantee security. We will present an assessment of the performance of our techniques with respect to security, sensitivity and robustness on the basis of a methodical and mathematically precise framework.

Janik, Tadeusz↗