Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Schrödinger Cats and Quantum Complementarity

Complementarity tells us we cannot know precisely the values of all the properties of a quantum object at the same time: the precise determination of one property implies that the value of some other (complementary) property is undefined. E.g. the precise knowledge of the position of a particle implies that its momentum is undefined. Here we show that a Schrödinger cat has a well defined value of a property that is complementary to its “being dead or alive” property. Then, thanks to complementarity, it has an undefined value of the property “being dead or alive”. In other words, the cat paradox is explained through quantum complementarity: of its many complementary properties, any quantum system, such as a cat, can have a well defined value only of one at a time. Schrödinger’s cat has a definite value of a property which is complementary to “being dead or alive”, so it is neither dead nor alive. Figuratively one can say it is both dead and alive. While this interpretation only uses textbook concepts (the Copenhagen interpretation), apparently it has never explicitly appeared in the literature. We detail how to build an Arduino based simulation of Schrödinger’s experiment based on these concepts for science outreach events.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nitrification is a minor source of nitrous oxide (N 2 O) in an agricultural landscape and declines with increasing management intensity

Abstract The long‐term contribution of nitrification to nitrous oxide (N 2 O) emissions from terrestrial ecosystems is poorly known and thus poorly constrained in biogeochemical models. Here, using Bayesian inference to couple 25 years of in situ N 2 O flux measurements with site‐specific Michaelis–Menten kinetics of nitrification‐derived N 2 O, we test the relative importance of nitrification‐derived N 2 O across six cropped and unmanaged ecosystems along a management intensity gradient in the U.S. Midwest. We found that the maximum potential contribution from nitrification to in situ N 2 O fluxes was 13%–17% in a conventionally fertilized annual cropping system, 27%–42% in a low‐input cover‐cropped annual cropping system, and 52%–63% in perennial systems including a late successional deciduous forest. Actual values are likely to be <10% of these values because of low N 2 O yields in cultured nitrifiers (typically 0.04%–8% of NH 3 oxidized) and competing sinks for available in situ. Most nitrification‐derived N 2 O was produced by ammonia‐oxidizing bacteria rather than archaea, who appeared responsible for no more than 30% of nitrification‐derived N 2 O production in all but one ecosystem. Although the proportion of nitrification‐derived N 2 O production was lowest in annual cropping systems, these ecosystems nevertheless produced more nitrification‐derived N 2 O (higher V max ) than perennial and successional ecosystems. We conclude that nitrification is minor relative to other sources of N 2 O in all ecosystems examined.

54 ENVIRONMENTAL SCIENCES↗

The fluorescence quantum yield parameter in Förster resonance energy transfer (FRET)—Meaning, misperception, and molecular design

The fluorescence quantum yield parameter in Förster resonance energy transfer (FRET) processes underpins vital phenomena ranging from light harvesting in photosynthesis to design of sensors for monitoring physiological processes. The criteria for choosing a donor for use in FRET processes include chemical features (solubility, bioconjugatability, synthetic accessibility, and stability) as well as photophysical properties pertaining to absorption (wavelength and molar absorption coefficient) and fluorescence (wavelength and fluorescence quantum yield). The value of the donor fluorescence quantum yield (Φf, or emphatically, Φf(D)) alone has sometimes been thought (erroneously) to place a ceiling on the possible quantum yield of energy transfer (Φtrans). A high value of the donor Φf, while attractive, is not at all essential; indeed, many valuable candidates for use as FRET donors have likely been excluded on the basis of this injudiciously applied filter. Such disregard is unwarranted. In this tutorial overview, the equations for FRET are reviewed along with pertinent core concepts in photophysics. An analogy using simple hydraulics provides a pedagogical tool for the non-aficionado to better understand photochemical kinetics. Ten examples are presented of donor–acceptor systems with donors that exhibit a range of Φf values (0.60, 0.59. 0.21, 0.17, 0.12, 0.118, 0.04, 0.018, 0.007, and 0.003; i.e., 60%–0.3%), yet for each corresponding donor–acceptor pair, the value of Φtrans is at least 0.70 and in some cases nearly 1.00 (i.e., 70%–100%). The systems encompass protein, synthetic inorganic, and synthetic organic architectures. The objectives of this illustrative review are to deepen understanding of FRET and to broaden molecular design considerations by enabling selection from among a far richer set of donors for use in FRET processes.

Lindsey, Jonathan S. (ORCID:0000000248722040)↗

Deep Learning for Modeling Enhanced Geothermal Systems

Enhanced Geothermal Systems (EGS) offer a vast potential to expand the use of geothermal energy. Heat is extracted from this engineered system by injecting cold water into a subsurface fractures, which are in contact with the hot dry rock, and pulled through the production wells. Creating EGS requires improving the natural permeability of hot crystalline rocks. To develop economically viable EGS reservoirs, significant technical barriers (e.g., better stimulation technologies without adequate water and/or permeability) and non-technical barriers (e.g., land access and permitting) must be overcome. In this short conference paper, we present a workflow to address a part of this challenge – “How to develop economically viable EGS using existing technologies?”. Our workflow called the GeoThermalCloud (GTC) for EGS, leverages recent advances in machine learning, deep learning, and cloud computing. This GTC framework is open-source and available at https://github.com/SmartTensors/GeoThermalCloud.jl. The GTC framework provides trained deep learning (DL) models to estimate the net present value of a given EGS design scenario. The Geothermal Design Tool (https://github.com/GeoDesignTool/GeoDT.git), a fast and simplified multi-physics solver, is used to develop a database for training DL models. The database consists of EGS design parameters (inputs to DL model) and their net present value (output of DL model) in uncertain geologic systems. The EGS design parameters for constructing this training database are based on Utah FORGE but include the options of more wells and deeper depths. The DL models are trained by ingesting the EGS design parameters and estimating the corresponding net present value. Such an emulation allows us to screen various EGS designs quickly and identify good development strategies by coupling them with optimization techniques. Our preliminary results show promise in DL emulation of net present value. However, a lot more work is needed to improve the predictive capability of DL models (i.e., extensive hyperparameter tuning is necessary). This will be the primary focus of our future work.

artificial neural networks, geothermal↗

Ergodic and nonergodic many-body dynamics in strongly nonlinear lattices

The study of nonlinear oscillator chains in classical many-body dynamics has a storied history going back to the seminal work of Fermi et al. [Los Alamos Scientific Laboratory Report No. LA-1940, 1955 (unpublished)]. Here, we introduce a family of such systems which consist of chains of N harmonically coupled particles with the nonlinearity introduced by confining the motion of each individual particle to a box or stadium with hard walls. The stadia are arranged on a one-dimensional lattice but they individually do not have to be one dimensional, thus permitting the introduction of chaos already at the lattice scale. For the most part we study the case where the motion is entirely one dimensional. We find that the system exhibits a mixed phase space for any finite value of N . Computations of Lyapunov spectra at randomly picked phase space locations and a direct comparison between Hamiltonian evolution and phase space averages indicate that the regular regions of phase space are not significant at large system sizes. While the continuum limit of our model is itself a singular limit of the integrable sinh Gordon theory, we do not see any evidence for the kind of nonergodicity famously seen in the work of Fermi et al. Finally, we examine the chain with particles confined to two-dimensional stadia where the individual stadium is already chaotic and find a much more chaotic phase space at small system sizes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Online Model-Free DER Dispatch Via Adaptive Voltage Sensitivity Estimation and Chance Constrained Programming

This paper proposes an online data-driven distributed energy resource management system (DERMS) for distribution system optimal DER dispatch as well as voltage regulation. Here, the key innovation is to leverage the Local Sensitivity Factor (LSF) for transforming the DER control into a computationally efficient linear programming (LP) problem. By taking real-time measurements, the estimation of LSF eliminates the need for an accurate distribution system model as well as full nodal load information, which is difficult to achieve in practice. A robust recursive least squares method is also developed to ensure the robust estimation of LSF, which is initialized using reasonable values from model-derived LSFs. This allows the system to adapt to changing operational conditions effectively. A scenario-based, chance-constrained framework is further employed to ensure voltage remains within acceptable limits in the presence of measurement and estimation uncertainties. Test results on a real-world, 759-node distribution network located in western Colorado, U.S., validate the effectiveness and robustness of the proposed control approach and demonstrate its superior performance as compared to alternative methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response: Preprint

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believes that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost benefit↗

Physics-based adaptivity of a spectral method for the Vlasov–Poisson equations based on the asymmetrically-weighted Hermite expansion in velocity space

We propose a spectral method for the 1D-1V Vlasov–Poisson system where the discretization in velocity space is based on asymmetrically-weighted Hermite functions, dynamically adapted via a scaling α and shifting u of the velocity variable. Specifically, at each time instant an adaptivity criterion selects new values of α and u based on the numerical solution of the discrete Vlasov–Poisson system obtained at that time step. Once the new values of the Hermite parameters α and u are fixed, the Hermite expansion is updated and the discrete system is further evolved for the next time step. The procedure is applied iteratively over the desired temporal interval. The key aspects of the adaptive algorithm are: the map between approximation spaces associated with different values of the Hermite parameters that preserves total mass, momentum and energy; and the adaptivity criterion to update α and u based on physics considerations relating the Hermite parameters to the average velocity and temperature of each plasma species. For the discretization of the spatial coordinate, we rely on Fourier functions and use the implicit midpoint rule for time stepping. The resulting numerical method possesses intrinsically the property of fluid-kinetic coupling, where the low-order terms of the expansion are akin to the fluid moments of a macroscopic description of the plasma, while kinetic physics is retained by adding more spectral terms. Moreover, the scheme features conservation of total mass, momentum and energy associated in the discrete, for periodic boundary conditions. A set of numerical experiments confirms that the adaptive method outperforms the non-adaptive one in terms of accuracy and stability of the numerical solution.

97 MATHEMATICS AND COMPUTING↗

Cost targets to achieve commercially viable thermal storage in buildings

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. In this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. Lastly, the economic value implied by different types of deferred peak power plants were reviewed. The full value of TES to the entire society consists of value to the utility, OEMs, facility installers, and other stakeholders. This report focuses on the value to the utility with emphasis on the deferred capital of peak power plant. The value from the deferred capital of peak power plant is manifested to the customer in the form of demand reduction program and Time-of-Use utility rate program. In this report, an initial proxy of the value of TES is made by assuming the deferred capital cost of power plant is the full value to reduce peak demand. Three levels of financial value of TES systems were assessed. Two are currently available to some residential customers: (1) the benefit from TOU pricing alone and (2) the benefit from TOU pricing in combination with DR incentive programs. The third level was computed as the full cost of deferred capital cost of peaking power plants. This represents the potential value that could be gained by the utilities or conceivably be offered to consumers.

25 ENERGY STORAGE↗

Resilience Valuation and Planning for Solar and Storage on Critical Infrastructure

This case study report documents the City's project evolution and the entrepreneurial ways through which the City approached the questions of how solar and storage could support their resilience efforts and how to value and pay for solar-plus-storage systems. This report documents how and why the City of Reno came to the specific conclusion to integrate solar and storage into their Public Safety Center retrofit project and apply for Federal Emergency Management Agency (FEMA) Building Resilient Infrastructure and Communities (BRIC) funding. (The City of Reno applied for and was awarded FEMA BRIC funding in January 2021; leveraging work that was underway in this project.) This report provides an overview for other local governments to draw inspiration from when considering how to prioritize community values and pursue multi-stakeholder dialogue around resilient energy solutions. The City of Reno's experience can serve as a starting point for other communities interested in valuing the resilience benefits of solar and storage.

14 SOLAR ENERGY↗

Privacy-Preserving Control of Partitioned Energy Resources

Distributed energy resources are an increasingly important part of the electric grid. We examine the problem of partitioning a distributed energy resource among many users while providing privacy to them. In this model, clients can send requests to a server, the server can verify that the requests are valid and aggregate them, but it cannot see the actual values in the requests. Without privacy, each user is forced to reveal their daily schedule or energy use. Energy resources add a novel challenge that prior systems do not address: they require verifying limits on private power (a rate over time) and energy (a sum) values. Furthermore, the cryptographic mechanisms must run on embedded energy control systems. We describe Weft, a novel cryptographic system that verifies both power (rate) and energy (integral) constraints on private client values and aggregates them. The key insight behind the approach is to rely on additively homomorphic secret shares, which allows servers to compute sums from rates. We present 3 cryptographic proof systems with different system trade-off for embedded systems: bit-splitting proofs minimize memory use, sorting proofs minimize computation, and commitment proofs minimize network communication. Using bit-splitting proofs, it takes an IoT client using a CortexM microcontroller 4 minutes of compute time to privately control its share of an energy resource for a day at 20s granularity.

Laufer, Evan↗

Techno-Economic Analysis of Recuperated Joule-Brayton Pumped Thermal Energy Storage

This article describes a techno-economic model for pumped thermal energy storage systems based on recuperated Joule-Brayton cycles and two-tank liquid storage. Models have been developed for each component, with particular emphasis on the heat exchangers. Economic metrics such as the power and energy capital costs (i.e., per-kW and per-kWh capacity) and levelized cost of storage are evaluated by gathering numerous cost correlations from the literature, thereby enabling estimates of uncertainty. It is found that the use of heat exchangers with effectivenesses up to 0.95 is economically worthwhile, but higher values lead to rapidly escalating component size and system cost. Several hot storage fluids are considered; those operating at the highest temperatures (chloride salts) improve the round-trip efficiency but the benefit is marginal and may not warrant the additional material costs and risk when compared to lower-temperature nitrate salts. Cost-efficiency trade-offs are explored using a multi-objective optimization algorithm, yielding optimal designs with round-trip efficiencies in the range 59-72% and corresponding levelized storage costs of 0.12 0.03 and 0.38 0.10 $/kWhe. Lifetime costs are competitive with lithium-ion batteries for discharging durations greater than 6 h under current scenarios.

Carnot battery↗

The Impacts of Distinct Flexibility Enhancements on the Value and Dynamics of Natural Gas Power Plant Operations

The rapid increase of renewable generation and its anticipated continued growth requires greater operational flexibility in modern power systems. Previous studies explored the addition of more flexible resources to improve system flexibility, but this may also be achieved at lower cost by enhancing existing power plants via flexibility retrofits. Potential flexibility upgrades to existing thermal plants include modifications that enable faster ramp rates, increase maximum load levels, decrease minimum load levels, and provide faster and lower cost startup operations. In this paper, we focus on improvements to existing natural gas combined cycle generators, and apply a unit commitment model to analyze the impact that each specific upgrade has on their operational dynamics and profitability from both the system perspective and from the asset owner perspective. We show that the value of each type of flexibility improvement varies depending on the capacity factor and usage pattern of the generator before the upgrade, and that the relative benefit of each type of flexibility varies. We demonstrate diminishing returns to increased flexibility when upgrading multiple generators simultaneously. Sensitivity tests for several shares of renewable generation, different generation mixes and different net load realizations confirm the generality of the results shown.

03 NATURAL GAS↗

What Is the Agent Doing? Visualizing Agentic AI Querying Workflows

We explore how visualizations can help users understand what an AI agent is doing as it builds and runs queries over data. As part of the LinkQ system, a natural language interface for querying knowledge graphs with a large language model (LLM), we designed two complementary views: A State Diagram that shows where the agent is within a larger workflow, and a Live Action Display that gives real-time updates about the agent's current task. In a study with 14 practitioners, we found that these visuals helped participants build stronger mental models of the agent's behavior while also increasing their confidence in the system. However, we also observed that users sometimes trusted incorrect outputs simply because the agent appeared to be doing the "right" thing. Our findings point to both the value and risk of visualizing agent behavior in interactive AI systems.

97 MATHEMATICS AND COMPUTING↗

Best Practices for Energy Management Information Systems Metadata Schemas

Fact sheet highlights best practices for metadata schemas and standard naming conventions, which improve the ability of an energy management information system (EMIS) to consistently analyze, visualize, and derive value from operational data. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of best practices for using metadata in an EMIS stack, which can significantly reduce the initial time required to deploy an EMIS.

data tags↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

AMORE-Isoprene v1.0: a new reduced mechanism for gas-phase isoprene oxidation

Abstract. Gas-phase oxidation of isoprene by ozone (O3) and the hydroxyl (OH) and nitrate (NO3) radicals significantly impacts tropospheric oxidant levels and secondary organic aerosol formation. The most comprehensive and up-to-date chemical mechanism for isoprene oxidation consists of several hundred species and over 800 reactions. Therefore, the computational expense of including the entire mechanism in large-scale atmospheric chemical transport models is usually prohibitive, and most models employ reduced isoprene mechanisms ranging in size from ∼ 10 to ∼ 200 species. We have developed a new reduced isoprene oxidation mechanism using a directed-graph path-based automated model reduction approach, with minimal manual adjustment of the output mechanism. The approach takes as inputs a full isoprene oxidation mechanism, the environmental parameter space, and a list of priority species which are protected from elimination during the reduction process. Our reduced mechanism, AMORE-Isoprene (where AMORE stands for Automated Model Reduction), consists of 12 species which are unique to the isoprene mechanism as well as 22 reactions. We demonstrate its performance in a box model in comparison with experimental data from the literature and other current isoprene oxidation mechanisms. AMORE-Isoprene's performance with respect to predicting the time evolution of isoprene oxidation products, including isoprene epoxydiols (IEPOX) and formaldehyde, is favorable compared with other similarly sized mechanisms. When AMORE-Isoprene is included in the Community Regional Atmospheric Chemistry Multiphase Mechanism 1.0 (CRACMM1AMORE) in the Community Multiscale Air Quality Model (CMAQ, v5.3.3), O3 and formaldehyde agreement with Environmental Protection Agency (EPA) Air Quality System observations is improved. O3 bias is reduced by 3.4 ppb under daytime conditions for O3 concentrations over 50 ppb. Formaldehyde bias is reduced by 0.26 ppb on average for all formaldehyde measurements compared with the base CRACMM1. There was no significant change in computation time between CRACMM1AMORE and the base CRACMM. AMORE-Isoprene shows a 35 % improvement in agreement between simulated IEPOX concentrations and chamber data over the base CRACMM1 mechanism when compared in the Framework for 0-D Atmospheric Modeling (F0AM) box model framework. This work demonstrates a new highly reduced isoprene mechanism and shows the potential value of automated model reduction for complex reaction systems.

58 GEOSCIENCES↗

Leveraging concentrating solar power plant dispatchability: A review of the impacts of global market structures and policy

Concentrating solar power (CSP) integrated with thermal energy storage delivers flexible and dispatchable power, which is an increasingly valuable quality as electricity systems integrate growing penetrations of variable renewable energy. Valuing and compensating CSP's dispatchability and flexibility requires electricity market structures and policies that appropriately remunerate generation during high-value portions of the day. In this paper, we review previous analyses of CSP economics and deployment, and we find that continued CSP growth will require valuation mechanisms that appropriately compensate for CSP's flexibility during both plant design and plant operation. We then review market structures that drive CSP operations and dispatch in jurisdictions where CSP is being developed, with perspectives from Spain, Chile, Australia, Morocco, South Africa, the United States, China, and the United Arab Emirates (Dubai). Despite broad agreement that CSP's dispatchability provides value to electricity grids, countries' policies for remunerating and leveraging such dispatchability varies widely. As deployment of CSP and variable renewable energy grows, it will be increasingly important to redesign current integration policies to signal the delivery of CSP's grid services more appropriately.

14 SOLAR ENERGY↗