Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Simulations of Positron Capture at Ce+BAF

We present a capture concept for the continuous wave (CW) polarized positron injector for the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (Ce+BAF). This two-step concept is based on (1) the generation of bremsstrahlung radiation by a longitudinally polarized electron beam 1 mA, 120 MeV, 90% polarization), passing through a tungsten target, and (2) the production of e+e--pairs by these bremsstrahlung photons in the same target. To provide highly-polarized positron beams (>60% polarization) or high-current positron beams (>1 µA) with low polarization for nuclear physics experiments, the positron source requires a flexible capture system with an adjustable energy selection band. The results of beam dynamics simulations and calculations of the power deposited in the positron capture section are presented.

Ushakov, Andriy↗

Hydroelectric Power and Hydrogen Production Integration

Hydropower-based hydrogen production could introduce opportunities for new revenue streams for hydropower plants, including from energy storage and regeneration as well as from sale of the hydrogen product to external markets. Hydrogen-based energy storage and regeneration could also help support Idaho Power’s decarbonization goals by decreasing dependence on fossil-based peaking power plants. Additionally, integration of hydrogen production with hydropower generation could help address the issue of low dissolved oxygen river water conditions that commonly accompany hydropower plant operations by utilizing the oxygen byproduct from an electrolytic hydrogen production process as a resource for mitigation of low dissolved oxygen water conditions. Comprehensive techno-economic analysis of the hybrid hydroelectric and hydrogen energy storage system has revealed critical insights into the pathways and considerations for optimizing the economic value and environmental benefits of such systems. Among the three identified pathways of natural gas blending, regeneration, and direct sale of hydrogen, the direct sale of hydrogen emerges as the most profitable, particularly given the current pricing dynamics of hydrogen and electricity. However, as we anticipate a future grid characterized by higher renewable energy penetration, the landscape may evolve, featuring lower average electricity prices, heightened fluctuations, and more significant seasonal variations. Consequently, the attractiveness of electricity regeneration through hydrogen and the benefits of long-duration hydrogen storage are expected to increase substantially in such a dynamic energy scenario. The careful selection of component sizes within the hybrid system proves to be paramount for ensuring cost-effectiveness. Notably, the size of the hydrogen market has emerged as a critical determinant for the optimal size of the electrolyzer. Hydrogen storage should be sized to meet energy shifting requirements. The appropriate size of the fuel cell/microturbine generator hinges on the shape of electricity prices and the available revenue streams derived from participating in grid services. Striking the right balance among these components is essential for maximizing the overall efficiency and profitability of the hydrogen facility. Furthermore, the by-product of electrolysis, namely oxygen, introduces an additional dimension to the system's functionality. The oxygen generated can be effectively utilized for dissolved oxygen (DO) mitigation, particularly with larger electrolyzer sizes capable of satisfying the complete oxygen demand for this purpose. While the economic benefits derived from saved oxygen purchase costs may be relatively modest compared to other revenue streams, the environmental advantages of repurposing oxygen for DO mitigation could help Idaho Power meet their environmental obligations. In addition to the identified factors shaping the viability of hybrid hydrogen production and hydroelectric generation, it is noteworthy that the integration of hydrogen energy storage offers a unique advantage during unusually wet years. In such periods of increased water inflow, the hydrogen storage capacity serves as a valuable supplement to the reservoir. By utilizing hydrogen energy storage as a complementary reservoir, the system gains flexibility in reservoir management when dealing with fluctuations in water availability.

08 HYDROGEN↗

Innovations in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerged as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment locations and the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of an efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study explores a novel Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration (is 90 oC really low temperature?). FAM’s exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale. The synthesis process involves a simple dip-coating technique, allowing crosslinked amines to coat glass substrates.

Wang, Qiuming↗

Advancements in Direct Air Capture: Unveiling a Simple and Robust Synthesized Fibrous Amine-functionalized Matrix (FAM) Sorbent for Commercial Scale-up

The escalating challenge of climate change necessitates innovative solutions in the realm of carbon management, particularly in mitigating the impact of fossil fuel emissions. Direct Air Capture (DAC) technology emerges as a critical component within the spectrum of Carbon Capture and Sequestration (CCS) solutions, offering the distinct advantage of directly removing CO2 from the atmosphere irrespective of the source. This attribute grants DAC systems unparalleled flexibility in deployment location sand the potential to make substantial contributions to lowing atmospheric CO2 levels. The success of DAC technologies significantly depends on the development of efficient, economical sorbent capable of selective and durable CO2 capture from ambient air. Recent advancements in material science have led to the exploration of amine-functionalized sorbents, hollow fiber sorbents and membranes, and other novel materials designed to meet these criteria. This study introduces a significant advancement in DAC technology with the development of a Fibrous Amine-functionalized Matrix (FAM) sorbent. The FAM sorbent distinguished itself through its mechanical robustness, a streamlined synthesis process, and the capability for low-temperature regeneration. Its exceptional adsorption-desorption kinetics enable swift CO2 capture and release, crucial for the viability of DAC on a commercial scale.

Wang, Qiuming↗

Dual-loop Solvent-based CCS for Net Negative CO 2 Emissions with Lower Cost

This final technical report details the successful design, construction, and operational validation of an innovative dual-loop CO 2 capture technology designed to achieve deep decarbonization (>99%) from Natural Gas Combined Cycle (NGCC) power plants that results in the electricity with carbon intensity of approximate 42 kg CO 2 -eq/MWh, less than the electricity produced by solar PV. The integrated process couples a primary aqueous solvent (in this project, a water lean solvent – WLS) absorption loop for bulk CO 2 removal with a secondary potassium hydroxide (KOH) polishing loop featuring electrochemical regeneration. This architecture leverages the higher exergy efficiency of the primary loop while utilizing the fastest kinetic of the secondary loop to capture dilute residual CO 2 , achieving an overall capture rate of 99.9% and co-producing pure hydrogen after moisture being condensed and dehydrated. Technical feasibility was established through a comprehensive 2,000-hour experimental campaign on a bench-scale fully-integrated unit (using 4” absorber and 4” stripper) with the feeding flue gas flowrate in the range of 8-20 cfm, confirming the attainment of Technology Readiness Level (TRL) 4. The project executed extensive parametric testing followed by 1,000 hours of continuous steady-state testing, demonstrating exceptional process stability with the electrochemical regenerator exhibiting less than a 10% reduction in electrical conductivity over the duration of the campaign. Operational characterization gathering on the bench unit revealed distinct energy profiles for the hybrid system: the primary loop required approximately 280 kJ mol -1 for bulk removal, while the polishing loop required approximately 1,600 kJ mol -1 specifically when reducing dilute CO 2 concentrations from ~740 ppm down to <50 ppm. (Please note those energy values/numbers can only be viewed as relative relationship and should not be extrapolated as absolute values required for CO 2 capture). Furthermore, dynamic testing validated the system’s flexibility for utility applications, demonstrating a rapid process response time of <30 minutes to changes in flue gas flowrate. Emission monitoring confirmed that the dual-loop architecture effectively mitigates solvent losses, utilizing a water wash to remove entrained aerosols to <1 ppm. The Techno-Economic Analysis (TEA) indicates a cost of capture of $\$$59.3/tonne and a Levelized Cost of Electricity (LCOE) of 71.7 $\$$/MWh at the overall capture efficiency of 99.8% of total carbon in the flue gas stream, with sensitivity analysis identifying an economic optimum when the primary loop captures 97% of the total CO 2 . A Life Cycle Assessment (LCA) confirms the technology’s potential for net-negative emissions, determining a Global Warming Potential (GWP) of 52 kg CO 2 -eq/MWh—significantly lower than the baseline—which further decreases to 42 kg CO 2 -eq/MWh when crediting the displacement of conventional hydrogen production.

03 NATURAL GAS↗

AM baseband telemetry techniques

Techniques and circuits used in designing AM highly flexible telemetry system comprising single sideband/double sideband/constant bandwidth compatible system - space application

Clubb, J. J.↗

Development of a collapsible reinforced cylindrical space observation window

Existing material technology was applied to the development of a collapsible transparent window suitable for manned spacecraft structures. The effort reported encompasses the evaluation of flame retardants intended for use in the window matrix polymer, evaluation of reinforcement angle which would allow for a twisting pantographing motion as the cylindrical window is mechanically collapsed upon itself, and evaluation of several reinforcement embedment methods. A fabrication technique was developed to produce a reinforced cylindrical space window of 45.7 cm diameter and 61.0 cm length. The basic technique involved the application of a clear film on a male-section mold; winding axial and girth reinforcements and vacuum casting the outer layer. The high-strength transparent window composite consisted of a polyether urethane matrix reinforced with an orthogonal pattern of black-coated carbon steel wire cable. A thin film of RTV silicone rubber was applied to both surfaces of the urethane. The flexibility, retraction system, and installation system are described.

Khan, A. Q.↗

Flexible format, computer accessed telemetry system

With this system, it is possible to sample and generate two or more simultaneous formats; one can be transmitted to ground station in real time, and other is stored for later transmission. Sensor output comparison data, plus information to control format, compression algorithm, and allowable degree of sensor activity, are stored in memory.

Easton, R. A.↗

Computer techniques used for some enhancements of ERTS images

The JPL VICAR image processing system has been used for the enhancement of images received from the ERTS for the Arizona geology mapping experiment. This system contains flexible capabilities for reading and repairing MSS digital tape images, for geometric corrections and interpicture registration, for various enhancements and analyses of the data, and for display of the images in black and white and color.

Billingsley, F. C.↗

Implementation experiences of NASTRAN on CDC CYBER 74 SCOPE 3.4 operating system

The implementation of the NASTRAN system on the CDC CYBER 74 SCOPE 3.4 Operating System is described. The flexibility of the NASTRAN system made it possible to accomplish the change with no major problems. Various sizes of benchmark and test problems, ranging from two hours to less than one minute CP time were run on the CDC CYBER SCOPE 3.3, Univac EXEC-8, and CDC CYBER SCOPE 3.4. The NASTRAN installation deck is provided.

Go, J. C.↗

Experimentally determined stiffness and damping of an inherently compensated air squeeze-film damper

Values of damping and stiffness were determined experimentally for an externally pressurized, inherently compensated, compressible squeeze-film damper up to excitation frequencies of 36,000 cycles per minute. Experimental damping values were higher than theory predicted at low squeeze numbers and less than predicted at high squeeze numbers. Experimental values of air film stiffness were less than theory predicted at low squeeze numbers and much greater at higher squeeze numbers. Results also indicate sufficient damping to attenuate amplitudes and forces at the critical speed when using three dampers in the flexible support system of a small, lightweight turborotor.

Cunningham, R. E.↗