Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Advanced light source-Upgrade accumulator-ring gas bremsstrahlung production

Lawrence Berkeley National Laboratory is designing a new electron synchrotron for scientific research using synchrotron radiation. An upgrade of the Advanced Light Source (ALS) would position the nation to retain its international competitiveness in the soft X-ray sciences. The ALS is a 1.9 GeV storage ring operating at 500 mA of beam current. It is optimized to produce intense beams of soft X-rays, which offer spectroscopic contrast, nanometer-scale resolution, and broad temporal sensitivity. Upgrading the ALS storage ring from a triple-bend-achromat to a multibend-achromat (MBA) lattice design will provide a soft X-ray source that is up to 100–1,000 times brighter than today’s ALS and will provide a significantly higher fraction of coherent light in the soft X-ray region than is currently available at the ALS. Further, the upgraded ALS will offer the highest coherent flux of any existing or planned storage-ring facility, worldwide, up to a photon energy of 3.5 keV. The addition of an accumulator ring that enables on-axis, swap-out, recovery, and exchange of bunch trains is required to achieve this coherence and brightness. Analysis of the radiation generated and shielding required by the addition of this new accelerator is presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time visualization of particle evolution during reactive flux-assisted processing of aluminum melts

Here, a multi-modal, multi-scale correlative tomography investigation of Al-TiC metal matrix composites processed via flux-assisted reaction synthesis is reported. Synchrotron X-ray microradiography is utilized to visualize the reaction and particle evolution in real-time. Changes in particle diameter and areal number density suggest that the process is nucleation- rather than growth-dominated. At 950 °C, the bulk of the reaction takes place in a relatively short time span of less than 600 s. The microstructure is imaged at higher resolution in 2D (scanning electron microscopy) and 3D (synchrotron X-ray nanotomography), revealing the formation of carbide particles with a hexagonal platelet morphology. We propose that the morphology arises due to the incorporation of Si impurities during the experiment. It is expected that the correlative tomography workflow and analysis may guide future metal matrix composite (MMC) processing strategies.

36 MATERIALS SCIENCE↗

Recent progress in high-temperature superconducting undulators

Considerable effort has been devoted to the development of superconducting undulators (SCUs) intended for particle accelerator-based light sources, including synchrotrons and free electron laser (FEL) facilities. Recently, a high-temperature superconducting (HTS) undulator prototype, consisting of staggered-array Re-Ba-Cu-O bulks, achieved an on-axis sinusoidal magnetic field profile with a peak amplitude B$_0$ of 2.1 T and a period length of 10 mm, resulting in a deflection parameter K = 1.96. Such a short period HTS undulator not only enables the generation of higher-energy photons, but also supports the construction of economically feasible and compact FELs with shorter linear accelerators (LINACs). This article provides a comprehensive review of recent advances in the staggered-array bulk HTS undulator as well as other types of HTS undulators. Furthermore, it offers insights into the development of engineering HTS undulator prototypes designed for deployment in synchrotron and free electron laser (FEL) facilities. We conclude by discussing opportunities for and the challenges facing the use of HTS undulators in practical applications.

43 PARTICLE ACCELERATORS↗

Photo-oxidation of semicrystalline polymers: Effect of stress triaxiality on ductility

The effect of stress triaxiality on the strain-to-fracture of as-received and photo-oxidized polyamide-6 (PA-6) was investigated using mechanical testing, synchrotron X-ray tomography, and finite element analyses. Mechanical tests were conducted on cylindrical and round notched specimens, where different notch radii were used to vary the stress triaxiality. The specimens were aged by exposure to ultra-violet (UV) radiation at 60∘, causing photo-oxidation. As-received and so-aged specimens were loaded to failure (complete loss of load carrying capacity). For both unaged and aged specimens, a higher triaxiality led to a lower strain-to-fracture. To elucidate the micromechanical damage that mediates fracture in both conditions, specimens with an intermediate notch sharpness were loaded to the peak load, unloaded, and scanned ex situ using synchrotron X-ray tomography. Damage in the unaged bar was found to occur by cavitation and was concentrated at the center of the specimen, where the triaxiality is highest. In the UV-aged bar, a network of inter-connected chemical cracks were found on the notch surface, where the triaxiality is lowest. Finite element analyses were deployed to approximate the local triaxiality at damaged regions in the unaged and UV-aged specimens using a constitutive relation for semicrystalline polymers. From these analyses, the relationship between local triaxiality and strain-to-fracture was quantified for both unaged and photo-oxidized PA-6. Both unaged and photo-oxidized PA-6 showed similar decreases in ductility with triaxiality, hinting at common ductile fracture processes.

36 MATERIALS SCIENCE↗

Quantitative Infrared-to-Terahertz Nanospectroscopy of Semiconductors

Semiconductor technology now employs few-nanometer features, necessitating tools probing electronic properties on the same length scale. While the concentration of free charge carriers is routinely measured, the scattering rate remains challenging to access at the nanoscale. Here, we present ultrabroadband (5–50 THz) synchrotron infrared nanospectroscopy as a quantitative metrology tool for semiconductors. This technique can determine both the charge carrier concentration and scattering rate with percent-level accuracy, and it is inherently capable of ∼10 nm spatial resolution. We study silicon with different doping levels and confirm the method’s accuracy by statistical analysis and comparison with established far-field infrared spectroscopy. Near-field measurements systematically reveal charge-carrier concentrations ∼30% lower than far-field values, consistent with increased surface sensitivity and surface depletion. Our work establishes synchrotron infrared nanospectroscopy as a precise tool for quantitative nanoscale semiconductor characterization and paves the way toward all-optical characterization of surface depletion effects.

36 MATERIALS SCIENCE↗

Shape Dependence of Pressure-Induced Phase Transition in CdS Semiconductor Nanocrystals

Understanding structural stability and phase transformation of nanoparticles under high pressure is of great scientific interest, as it is one of the crucial factors for design, synthesis, and application of materials. Even though high-pressure research on nanomaterials has been widely conducted, their shape-dependent phase transition behavior still remains unclear. Examples of phase transitions of CdS nanoparticles are very limited, despite the fact that it is one of the most studied wide band gap semiconductors. Here we have employed in-situ synchrotron wide-angle X-ray scattering (WAXS) and transmission electron microscopy (TEM) to investigate the high-pressure behaviors of CdS nanoparticles as a function of particle shapes. We observed that CdS nanoparticles transform from wurtzite to rocksalt phase at elevated pressure in comparison to their bulk counterpart. Phase transitions also vary with particle shape—rod-shaped particles show a partially reversible phase transition and the onset of the structural phase transition pressure decreases with decreasing surface-to-volume ratios, while spherical particles undergo irreversible phase transition with relatively low phase transition pressure. Additionally, TEM images of spherical particles exhibited sintering-induced morphology change after high-pressure compression. Calculations of the bulk modulus reveals that spheres are more compressible than rods in the wurtzite phase. These results indicate that the shape of the particle plays an important role in determining their high-pressure properties. Our study provides important insights into understanding of the phase-structure-property relationship, guiding future design and synthesis of nanoparticles for promising applications.

36 MATERIALS SCIENCE↗

X-ray imaging of liquid-liquid Mg cavitation

The coupling of dynamic loading platforms with synchrotron light sources have enabled experiments examining void formation in optically opaque materials. Much like spallation in a solid, cavitation occurs when rarefaction waves collide within a liquid. The resulting deformation leads to a complex flow field with numerous voids. It has been suggested that compaction of such a structure may be a significant source of ejecta (i.e. shallow bubble collapse). Experiments imaging supported and unsupported shocks interacting with a free surface in shock melted Mg with synchrotron radiation are presented. Here, the results are used to examine the structure of a cavitation plane that forms in the unsupported case and provide an estimate of the porosity within this region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polyamorphism in a solute-lean Al–Ce metallic glass

Polyamorphism discovered in lanthanide-rich metallic glasses (MGs) has been attributed to the electronic transition of the lanthanide element as a solvent element. In this work, we report that pressure-induced polyamorphism still exists in a Ce-poor Al 93 Ce 7 binary MG where the 4f electron element serves as a solute and solute–solute avoidance is expected. The polyamorphic transition, observed by in situ high-pressure synchrotron x-ray diffraction, is accompanied by a volume collapse of ~0.78% and occurs over a narrow pressure range from ~0.8 to ~1.8 GPa. Further synchrotron Ce L 3 -edge x-ray absorption spectroscopy measurements reveal that pressure-induced 4f electron delocalization underlies the polyamorphic transition. Molecular dynamics simulations confirm that the Ce atoms in the MG are completely isolated by the solvent Al atoms. This result demonstrates that 4f element-bearing alloys with extremely dilute concentrations can also exhibit polyamorphic states originating from electronic transitions, extending the compositional space of polyamorphism of MGs into very dilute regions. Our work suggests that tunable properties under compressive stress could be achieved in MGs by even minor doping of elements prone to electronic transitions.

36 MATERIALS SCIENCE↗

Simultaneous ambient pressure x-ray photoelectron spectroscopy and grazing incidence x-ray scattering in gas environments

We have developed an experimental system to simultaneously measure surface structure, morphology, composition, chemical state, and chemical activity for samples in gas phase environments. This is accomplished by simultaneously measuring x-ray photoelectron spectroscopy (XPS) and grazing incidence x-ray scattering in gas pressures as high as the multi-Torr regime while also recording mass spectrometry. Scattering patterns reflect near-surface sample structures from the nano-scale to the meso-scale, and the grazing incidence geometry provides tunable depth sensitivity of structural measurements. Scattered x rays are detected across a broad range of angles using a newly designed pivoting-UHV-manipulator for detector positioning. At the same time, XPS and mass spectrometry can be measured, all from the same sample spot and under ambient conditions. To demonstrate the capabilities of this system, we measured the chemical state, composition, and structure of Ag-behenate on a Si(001) wafer in vacuum and in O 2 atmosphere at various temperatures. These simultaneous structural, chemical, and gas phase product probes enable detailed insights into the interplay between the structure and chemical state for samples in gas phase environments. The compact size of our pivoting-UHV-manipulator makes it possible to retrofit this technique into existing spectroscopic instruments installed at synchrotron beamlines. Because many synchrotron facilities are planning or undergoing upgrades to diffraction limited storage rings with transversely coherent beams, a newly emerging set of coherent x-ray scattering experiments can greatly benefit from the concepts we present here.

47 OTHER INSTRUMENTATION↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

Peculiarities of planar shockwave interaction with air–water interface and solid target

We present the results of the research on underwater electrical explosion of planar copper wire arrays, accompanied by the generation of a planar shock, using the synchrotron-based phase-contrast radiography imaging capabilities of the ID19 beamline at the European Synchrotron Radiation Facility. It is shown that the interaction of a strong shock with an air–water interface leads to additional acceleration of the wire expansion due to a rarefaction wave along with the emergence of micro-jets. In the case of a target placed above the array, we observed the formation of a cavity between the array and the target due to the interaction of two rarefaction waves. Furthermore, the results of two-dimensional hydrodynamic simulations of the wire explosion and the interaction of the generated shock with the water–air and water-target interfaces showed good agreement with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Principles and applications of x-ray light sources driven by laser wakefield acceleration

One of the most prominent applications of modern particle accelerators is the generation of radiation. In a synchrotron or an x-ray free electron laser (XFEL), high energy electrons oscillating in periodic magnetic structures emit bright x rays. In spite of their scientific appeal that will remain evident for many decades, one limitation of synchrotrons and XFELs is their typical mile-long size and their cost, which often limits access to the broader scientific community. Here, this tutorial reviews the principles and prospects of using plasmas produced by intense lasers as particle accelerators and x-ray light sources, as well as some of the applications they enable. A plasma is an ionized medium that can sustain electrical fields many orders of magnitude higher than that in conventional radio frequency accelerator structures and can be used to accelerate electrons. When short, intense laser pulses are focused into a gas, it produces electron plasma waves in which electrons can be trapped and accelerated to GeV energies. This process, laser-wakefield acceleration (LWFA), is analogous to a surfer being propelled by an ocean wave. Many radiation sources, from THz to gamma-rays, can be produced by these relativistic electrons. This tutorial reviews several LWFA-driven sources in the keV-MeV photon energy range: betatron radiation, inverse Compton scattering, bremsstrahlung radiation, and undulator/XFEL radiation. X rays from laser plasma accelerators have many emerging applications. They can be used in innovative and flexible x-ray imaging and x-ray absorption spectroscopy configurations, for use in biology, industry, and high-energy density science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Epitaxial oxide ionotronics: Interfaces and oxygen vacancies

Oxide ionotronics is an interdisciplinary field in which systems and devices rely on the migration of ions/ionic defects to alter or drive functionality. In this perspective, we focus on epitaxial oxide heterostructures and the contributing roles of oxygen vacancies and interfaces in ionotronics. We begin with a description of oxygen vacancy behavior, with a focus on vacancy ordering and the effects of interfaces and electric fields on particular epitaxial oxide systems. We then emphasize the use of synchrotron x-ray techniques for investigating system structure and dynamics in situ at interfaces and surfaces. Finally, an outlook on the future of epitaxial oxide ionotronics is provided, and several key areas for research are identified, such as freestanding heterostructures, combinatorial synthesis and machine learning, and next-generation synchrotron x-ray characterization.

36 MATERIALS SCIENCE↗

Pressure effect on magnetism and valence in ferromagnetic superconductor Eu(Fe 0.75 Ru 0.25 ) 2 As 2

Eu(Fe 0.75 Ru 0.25 ) 2 As 2 is an intriguing system with unusual coexistence of superconductivity and ferromagnetism, providing a unique platform to study the nature of such coexistence. To establish a magnetic phase diagram, time-domain synchrotron Mössbauer experiments in 151 Eu have been performed on a single crystalline Eu(Fe 0.75 Ru 0.25 ) 2 As 2 sample under hydrostatic pressures and at low temperatures. Upon compression the magnetic ordering temperature increases sharply from 20 K at ambient pressure, reaching ~49 K at 10.1GPa. With further compression, the magnetic order is suppressed and eventually collapses. Isomer shift values from Mössbauer measurements and x-ray absorption spectroscopy data at Eu L 3 edge show that pressure drives Eu ions to a homogeneous intermediate valence state with mean valence of ~2.4 at 27.4 GPa, possibly responsible for the suppression of magnetism. Synchrotron powder x-ray diffraction experiment reveals a tetragonal to collapsed-tetragonal structural transition around 5 GPa, a lower transition pressure than in the parent compound. Furthermore, these results provide guidance to further work investigating the interplay of superconductivity and magnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High spatial resolution direct conversion amorphous selenium X-ray detectors with monolithically integrated CMOS readout

Recent progress in the field of micron-scale spatial resolution direct conversion X-ray detectors for high-energy synchrotron light sources serve applications ranging from nondestructive and noninvasive microscopy techniques which provide insight into the structure and morphology of crystals, to medical diagnostic measurement devices. Amorphous selenium ( a -Se) as a wide-bandgap thermally evaporated photoconductor exhibits ultra-low thermal generation rates for dark carriers and has been extensively used in X-ray medical imaging. Being an amorphous material, it can further be deposited over large areas at room temperatures and at substantially lower costs as compared to crystalline semiconductors. Here, to address the demands for a high-energy and high spatial resolution X-ray detector for synchrotron light source applications, we have thermally evaporated a -Se on a Mixed-Mode Pixel Array Detector (MM-PAD) Application Specific Integrated Circuit (ASIC). The ASIC format consists of 128 × 128 square pixels each 150 μm on a side. A 200 μm a -Se layer was directly deposited on the ASIC followed by a metal top electrode. The completed detector assembly was tested with 45 kV Ag and 23 kV Cu X-ray tube sources. The detector fabrication, performances, Modulation Transfer Function (MTF) measurements, and simulations are reported.

36 MATERIALS SCIENCE↗

Nucleation and growth of polar clusters with in-phase tilts into a long-range ferroelectric matrix in a sodium niobate based complex relaxor

In this study, we have investigated the temperature dependence of atomic ordering at multiple length scales in a lead-free sodium niobate-based relaxor, i.e., 0.75 NaNbO 3 -0.25 Ba 0.9⁢ Ca 0.1⁢ TiO 3 (NN-25BCT) via synchrotron x-ray diffraction, Raman spectroscopy, and pair distribution function analysis. High-resolution synchrotron x-ray powder diffraction (SXRD) measurements reveal a ferroelectric phase transition in the relaxor ferroelectric NN-25BCT below the Vogel-Fulcher freezing temperature (𝑇 VF ≈ 270 K). In addition, SXRD analysis demonstrates the competition between in-phase octahedral tilting and ferroelectric order at the long-range scale using mode crystallography. On the other hand, Raman spectroscopic analysis provides evidence of polar ordering for 𝑇 > 𝑇 VF (with tetragonal symmetry) persisting up to the Burns temperature (𝑇 B ). Furthermore, pair distribution function (PDF) analysis reveals the presence of a polar antiferrodistortive tetragonal phase with 𝑃⁢4⁢𝑏𝑚 space group at short ranges throughout the studied temperatures (i.e., 110 K ≤ 𝑇 ≤500 K), irrespective of nonpolar long-range ordering above 𝑇 VF . Therefore, our measurements provide direct evidence for the presence of polar ordering at short ranges and their gradual transformation into long-range polar ordering using an integrated multiscale structural analysis. In conclusion, as a result of a transition from relaxor to a ferroelectric phase in the vicinity of room temperature, NN-25BCT can be exploited for applications in pyroelectric detectors, electrocaloric devices, and multilayered ceramic capacitors.

36 MATERIALS SCIENCE↗

Development of a versatile electrochemical cell for in situ grazing-incidence X-ray diffraction during non-aqueous electrochemical nitrogen reduction

In situ techniques are essential to understanding the behavior of electrocatalysts under operating conditions. When employed, in situ synchrotron grazing-incidence X-ray diffraction (GI-XRD) can provide time-resolved structural information of materials formed at the electrode surface. In situ cells, however, often require epoxy resins to secure electrodes, do not enable electrolyte flow, or exhibit limited chemical compatibility, hindering the study of non-aqueous electrochemical systems. Here, a versatile electrochemical cell for air-free in situ synchrotron GI-XRD during non-aqueous Li-mediated electrochemical N 2 reduction (Li-N 2 R) has been designed. This cell not only fulfills the stringent material requirements necessary to study this system but is also readily extendable to other electrochemical systems. Under conditions relevant to non-aqueous Li-N 2 R, the formation of Li metal, LiOH and Li 2 O as well as a peak consistent with the α-phase of Li 3 N was observed, thus demonstrating the functionality of this cell toward developing a mechanistic understanding of complicated electrochemical systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗