Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “surface exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Modeling the Martian seasonal CO2 cycle. I - Fitting the Viking Lander pressure curves. II - Interannual variability

The present diurnal and seasonal thermal model for Mars, in which surface CO2 frost condensation and sublimation are determined by the net effects of radiation, latent heat, and heat conduction in subsurface soil layers, in order to simulate seasonal exchanges of CO2 between the polar caps and atmosphere, successfully reproduces the measured pressured variations at the Viking Lander 1 site. In the second part of this work, the year-to-year differences between measured surface pressures at Viking sites as a function of season are used as upper limits on the potential magnitudes of interannual variations in the Martian atmosphere's mass. Simulations indicate that the dust layers deposited onto the condensing north seasonal polar cap during dust storms can darken seasonal frost deposits upon their springtime uncovering, while having little effect on seasonal pressure variations.

Wood, Stephen E.↗

Testing of a Spray-Bar Zero Gravity Cryogenic Vent System for Upper Stages

The capability to vent in zero gravity without resettling is a fundamental technology need that involves practically all uses of subcritical cryogenics in space. Venting without resettling would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule- Thomson (J-T) valve to extract then-nal energy from the propellant. In a cooperative effort, Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (N4HTB) was used to test a unique "spray bar" TVS system developed by Boeing. A schematic of this system is included in Figure 1. The system consists of a recirculation pump, a parallel flow concentric tube, heat exchanger, and a spray bar positioned close to the longitudinal axis of the tank. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it radially into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the spray bar heat exchanger element, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. Figure 2 is a plot of ullage pressure (P4) and liquid vapor pressure (PSAI) versus time. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses. The primary advantage of the spray bar configuration is that pressure reduction is achieved independent of liquid and vapor location, thereby enhancing the applicability of normal gravity test data to zero gravity conditions. The in-tank components are minimized with the proposed TVS design. Because the recirculation pump is external to the tank, no electrical power penetration of the tank is required for pump or valve operation. This is especially desirable for L02 tanks since the presence of an electrical ignition source in oxygen represents a critical failure mode. Also, since the critical components (pump, motor, valve, orifice) are external to the tank, system checkout and ground servicing/replacement are easier. For zero-g operation, component replacement external to the tank may be a significant benefit. In addition to satisfying the zero g TVS design objectives, the TVS concept tested offers additional benefits to the integrated subcritical cryogenic storage and launch system.

Lak, Tibor↗

Study and modification of the reactivity of carbon fibers

The reactivity to air of polyactylonitrile-based carbon fiber cloth was enhanced by the addition of metals to the cloth. The cloth was oxidized in 54 wt% nitric acid in order to increase the surface area of the cloth and to add carbonyl groups to the surface. Metal addition was then achieved by soaking the cloth in metal acetate solution to effect exchange between the metal carbon and hydrogen on the carbonyl groups. The addition of potassium, sodium, calcium and barium enhanced fiber cloth reactivity to air at 573 K. Extended studies using potassium addition showed that success in enhancing fiber cloth reactivity to air depends on: extent of cloth oxidation in nitric acid, time of exchange in potassium acetate solution and the thoroughness of removing metal acetate from the fiber pore structure following exchange. Cloth reactivity increases essentially linearly with increase in potassium addition via exchange.

Walker, P. L., Jr.↗

Size distribution of oceanic air bubbles entrained in sea-water by wave-breaking

The size of oceanic air bubbles produced by whitecaps and wave-breaking is determined. The production of liquid aerosols at the sea surface is predicted. These liquid aerosols are at the origin of most of the particulate materials exchanged between the ocean and the atmosphere. A prototype was designed and built using an optical technique based on the principle of light scattering at an angle of ninety degrees from the incident light beam. The output voltage is a direct function of the bubble diameter. Calibration of the probe was carried out within a range of 300 microns to 1.2 mm. Bubbles produced by wave-breaking in a large air-sea interaction simulating facility. Experimental results are given in the form of size spectrum.

Resch, F.↗

Test results on re-use of reclaimed shower water: Summary

A microgravity whole body shower (WBS) and waste water recovery systems (WWRS) were evaluated in three separate closed loop tests. Following a protocol similar to that anticipated for the U.S. Space Station, test subjects showered in a prototype whole body shower. The WWRS processes evaluated during the test series were phase change and reverse osmosis (RO). A preprototype Thermoelectric Integrated Hollow Fiber Membrane Evaporation Subsystem phase change process was used for the initial test with chemical pretreatment of the shower water waste input. The second and third tests concentrated on RO technologies. The second test evaluated a dynamic RO membrane consisting of zirconium oxide polyacrylic acid (ZOPA) membranes deposited on the interior diameter of 316L porous stainless steel tubes while the final test employed a thin semipermeable RO membrane deposited on the interior surface of polysulfone hollow fibers. All reclaimed water was post-treated for purity using ion exchange and granular activated carbon beds immediately followed by microbial control treatment using both heat and iodine. The test hardware, controls exercised for whole body showering, types of soaps evaluated, shower subject response to reclaimed water showering, and shower water collection and chemical pretreatment (if required) for microbial control are described. The WWRS recovered water performance and the effectiveness of the reclaimed water post-treatment techniques used for maintaining water purity and microorganism control are compared. Results on chemical and microbial impurity content of the water samples obtained from various locations in the shower water reuse system are summarized.

Verostko, C. E.↗

Axisymmetric shapes and stability of isolated charged drops

Axisymmetric equilibrium shapes and stability of isolated charged drops are found by solving simultaneously the Young-Laplace equation for surface shape and the Laplace equation for the electric field. Families of two-, three-, and four-lobed shapes that branch from the trunk family of spheres are treated systematically by means of the Galerkin/finite element method and a tessellation that deforms with the free surface. The results show that at the limit found by Rayleigh in 1882 the spherical family exchanges stability with a family of two-lobed shapes, a transcritically bifurcating family, one arm of which proves to consist of stable shapes. The results are reinforced by those of approximating the stable drop shapes as oblate spheroids. Thus oblate drops carrying charge in excess of the Rayleigh limit ought to be seen in experiments, though none have yet been reported.

Basaran, O. A.↗

Plasma-neutral interaction processes in the magnetosphere of Saturn

Models of Saturnian magnetospheric processes are reviewed emphasizing the interaction of charged and neutral particles in the gaseous phase and mentioning the role of solid matter. It is found that interpretations of different Voyager datasets regarding the Saturnian magnetosphere can vary. Specific interactions examined to resolve these discrepancies include charge exchange, ion-atom interchange, isotropizing and thermalizing collisions, and interactions between magnetospheric charged particles and surface layers of the icy satellites. The latter interactions result in sputtering of the surface or atmosphere as well as neutral injections into the magnetosphere. Constraints based on known reaction rates are shown to be useful in analyzing the abundances of the water-group molecules. The composition of the magnetospheric plasma is shown to be related to the differences between the interactions of atomic and molecular plasmas with neutral matter.

Eviatar, Aharon↗

Design of a cavity heat pipe receiver experiment

A cavity heat pipe experiment has been designed to test the critical issues involved with incorporating thermal energy storage canisters into a heat pipe. The experiment is a replication of the operation of a heat receiver for a Brayton solar dynamic power cycle. The heat receiver is composed of a cylindrical receptor surface and an annular heat pipe with thermal energy storage canisters and gaseous working fluid heat exchanger tubes surrounding it. Hardware for the cavity heat pipe experiment will consist of a sector of the heat pipe, complete with gas tube and thermal energy storage canisters. Thermal cycling tests will be performed on the heat pipe sector to simulate the normal energy charge/discharge cycle of the receiver in a spacecraft application.

Schneider, Michael G.↗

Preparation and Characterization of Polyimide Nanocomposites

Many properties of polymeric materials can be enhanced by dispersing small quantities of clay nanocomposites throughout the polymer. Among the enhancements are increases in modulus and resistance to erosion by atomic oxygen and reductions in thermal expansivity, gas permeability, and flammability. To achieve the full extent of enhancement with these polymer-clay nanocomposites, the clay nanoparticles, which have thicknesses of only one-to-several nanometers and lengths and widths of hundreds of nanometers to micrometers, must be exfoliated one from another and then individually dispersed throughout the polymer. This dispersion is achieved only after alkali metal cations (usually Na(+)) that reside on the surfaces of the nanoparticles have been replaced by organocations (typically a quaternary amine cation). This renders the surface of the nanoparticle a more hospitable interface for the organic polymer matrix. Following the cation exchange, the organic clay is either mixed directly into the polymer or is dispersed in monomer which is later polymerized around the nanoparticle.

Orwoll, Robert A.↗

A Multi-scale Approach to Urban Thermal Analysis

An environmental consequence of urbanization is the urban heat island effect, a situation where urban areas are warmer than surrounding rural areas. The urban heat island phenomenon results from the replacement of natural landscapes with impervious surfaces such as concrete and asphalt and is linked to adverse economic and environmental impacts. In order to better understand the urban microclimate, a greater understanding of the urban thermal pattern (UTP), including an analysis of the thermal properties of individual land covers, is needed. This study examines the UTP by means of thermal land cover response for the Salt Lake City, Utah, study area at two scales: 1) the community level, and 2) the regional or valleywide level. Airborne ATLAS (Advanced Thermal Land Applications Sensor) data, a high spatial resolution (10-meter) dataset appropriate for an environment containing a concentration of diverse land covers, are used for both land cover and thermal analysis at the community level. The ATLAS data consist of 15 channels covering the visible, near-IR, mid-IR and thermal-IR wavelengths. At the regional level Landsat TM data are used for land cover analysis while the ATLAS channel 13 data are used for the thermal analysis. Results show that a heat island is evident at both the community and the valleywide level where there is an abundance of impervious surfaces. ATLAS data perform well in community level studies in terms of land cover and thermal exchanges, but other, more coarse-resolution data sets are more appropriate for large-area thermal studies. Thermal response per land cover is consistent at both levels, which suggests potential for urban climate modeling at multiple scales.

Gluch, Renne↗

Methods for Characterizing Fine Particulate Matter Using Satellite Remote-Sensing Data and Ground Observations: Potential Use for Environmental Public Health Surveillance

This study describes and demonstrates different techniques for surfacing daily environmental / hazards data of particulate matter with aerodynamic diameter less than or equal to 2.5 micrometers (PM2.5) for the purpose of integrating respiratory health and environmental data for the Centers for Disease Control and Prevention (CDC s) pilot study of Health and Environment Linked for Information Exchange (HELIX)-Atlanta. It described a methodology for estimating ground-level continuous PM2.5 concentrations using B-Spline and inverse distance weighting (IDW) surfacing techniques and leveraging National Aeronautics and Space Administration (NASA) Moderate Resolution Imaging Spectrometer (MODIS) data to complement The Environmental Protection Agency (EPA) ground observation data. The study used measurements of ambient PM2.5 from the EPA database for the year 2003 as well as PM2.5 estimates derived from NASA s satellite data. Hazard data have been processed to derive the surrogate exposure PM2.5 estimates. The paper has shown that merging MODIS remote sensing data with surface observations of PM2.5 not only provides a more complete daily representation of PM2.5 than either data set alone would allow, but it also reduces the errors in the PM2.5 estimated surfaces. The results of this paper have shown that the daily IDW PM2.5 surfaces had smaller errors, with respect to observations, than those of the B-Spline surfaces in the year studied. However the IDW mean annual composite surface had more numerical artifacts, which could be due to the interpolating nature of the IDW that assumes that the maxima and minima can occur only at the observation points. Finally, the methods discussed in this paper improve temporal and spatial resolutions and establish a foundation for environmental public health linkage and association studies for which determining the concentrations of an environmental hazard such as PM2.5 with good accuracy levels is critical.

Al-Hamdan, Mohammad Z.↗

Phase Change Material Heat Exchanger Life Test

Low Lunar Orbit (LLO) poses unique thermal challenges for the orbiting space craft, particularly regarding the performance of the radiators. The emitted infrared (IR) heat flux from the lunar surface varies drastically from the light side to the dark side of the moon. Due to the extremely high incident IR flux, especially at low beta angles, a radiator is oftentimes unable to reject the vehicle heat load throughout the entire lunar orbit. One solution to this problem is to implement Phase Change Material (PCM) Heat Exchangers. PCM Heat Exchangers act as a "thermal capacitor," storing thermal energy when the radiator is unable to reject the required heat load. The stored energy is then removed from the PCM heat exchanger when the environment is more benign. Because they do not use an expendable resource, such as the feed water used by sublimators and evaporators, PCM Heat Exchangers are ideal for long duration Low Lunar Orbit missions. The Advanced Thermal Control project at JSC is completing a PCM heat exchanger life test to determine whether further technology development is warranted. The life test is being conducted on four nPentadecane, carbon filament heat exchangers. Fluid loop performance, repeatability, and measurement of performance degradation over 2500 melt-freeze cycles will be performed and reported in the current document.

Lillibridge, Sean↗

Optimizing GRACE/GRACE-FO Data and A priori Hydrological Knowledge for Improved Global Terrestial Water Storage Component Estimates

The comprehensive information of global terrestrial water storage (TWS) components (soil moisture, groundwater, snow, surface water) is essential for effective assessment of water resource availability, climate variation, and disaster mitigation measures. Observational data provided by the Gravity Recovery And Climate Experiment (GRACE) and GRACE Follow-On satellite missions offer global TWS variation (ΔTWS) in terms of an integrated water column. However, GRACE spatial resolution is relatively coarse (i.e., 3°), and the vertically integrated value cannot be separated into ΔTWS components directly. This study demonstrates the feasibility to estimate ΔTWS components at any desired spatial-vertical resolution by effectively maintaining the native resolution of the employed hydrological knowledge. It utilizes a least-squares with constraints (LSC) approach to rigorously incorporate GRACE and GRACE-FO data and a priori hydrological knowledge, with the aim to improve global ΔTWS components’ accuracy and spatial resolution. The 3°×3° GRACE mascon derived ΔTWS data is disaggregated into the 0.5°×0.5° anomalous soil moisture storage (ΔSMS), groundwater storage (ΔGWS), snow water equivalent (ΔSWE), and surface water storage (ΔSWS) based on the covariance information obtained from the Community Atmosphere Biosphere Land Exchange (CABLE) and the PCRaster Global Water Balance (PCR-GLOBWB) models. Evaluation with different ground measurements and satellite products between 2002 and 2019 exhibits significantly improved accuracy in all individual ΔTWS components. This improvement is of particular note in ΔGWS and ΔSWS, where the LSC approach increases the globally averaged correlation values by approximately 0.13 and 0.05, respectively. Reliable prior knowledge leads to a more accurate ΔTWS component estimate, and the use of ensemble-mean knowledge yields the best result.

GRACE↗

Zero Gravity Cryogenic Vent System Concepts for Upper Stages

The capability to vent in zero gravity without resettling is a technology need that involves practically all uses of sub-critical cryogenics in space, and would extend cryogenic orbital transfer vehicle capabilities. However, the lack of definition regarding liquid/ullage orientation coupled with the somewhat random nature of the thermal stratification and resulting pressure rise rates, lead to significant technical challenges. Typically a zero gravity vent concept, termed a thermodynamic vent system (TVS), consists of a tank mixer to destratify the propellant, combined with a Joule-Thomson (J-T) valve to extract thermal energy from the propellant. Marshall Space Flight Center's (MSFC's) Multipurpose Hydrogen Test Bed (MHTB) was used to test both spray-bar and axial jet TVS concepts. The axial jet system consists of a recirculation pump heat exchanger unit. The spray-bar system consists of a recirculation pump, a parallel flow concentric tube heat exchanger, and a spray-bar positioned close to the longitudinal axis of the tank. The operation of both concepts is similar. In the mixing mode, the recirculation pump withdraws liquid from the tank and sprays it into the tank liquid, ullage, and exposed tank surfaces. When energy extraction is required, a small portion of the recirculated liquid is passed sequentially through the J-T expansion valve, the heat exchanger, and is vented overboard. The vented vapor cools the circulated bulk fluid, thereby removing thermal energy and reducing tank pressure. The pump operates alone, cycling on and off, to destratify the tank liquid and ullage until the liquid vapor pressure reaches the lower set point. At that point, the J-T valve begins to cycle on and off with the pump. Thus, for short duration missions, only the mixer may operate, thus minimizing or even eliminating boil-off losses.

Flachbart, Robin H.↗

All-metal, compact heat exchanger for space cryocoolers

This report describes the development of a high performance, all metal compact heat exchanger. The device is designed for use in a reverse Brayton cryogenic cooler which provides five watts of refrigeration at 70 K. The heat exchanger consists of a stainless steel tube concentrically assembled within a second stainless steel tube. Approximately 300 pairs of slotted copper disks and matching annular slotted copper plates are positioned along the centerline axis of the concentric tubes. Each of the disks and plates has approximately 1200 precise slots machined by means of a special electric discharge process. Positioning of the disk and plate pairs is accomplished by means of dimples in the surface of the tubes. Mechanical and thermal connections between the tubes and plate/disk pairs are made by solder joints. The heat exchanger assembly is 9 cm in diameter by 50 cm in length and has a mass of 10 kg. The predicted thermal effectiveness is greater than 0.985 at design conditions. Pressure loss at design conditions is less than 5 kPa in both fluid passages. Tests were performed on a subassembly of plates integrally soldered to two end headers. The measured thermal effectiveness of the test article exceeded predicted levels. Pressure losses were negligibly higher than predictions.

Swift, Walter L.↗

Definition of a Technology Validation Mission for P-band Reflectometry using Signals of Opportunity

Root-Zone Soil Moisture (RZSM) (moisture profile in the top meter of soil) and Snow Water Equivalent (SWE) (total snow pack water content) are identified as priority target variables in the ESAS 2017 decadal survey [1] with critical roles in hydrology and water management. RZSM estimates are vital for understanding multiple Earth system processes and forecasting (for example, droughts [2]). Simultaneous knowledge of surface and RZSM could enable a breakthrough in estimating key unobserved hydrologic fluxes and reduce uncertainty in net ecosystem exchange (NEE), carbon balance [3] discharge estimates, and crop yield forecasts [4] .With the high albedo and insulating properties of snow, monitoring, SWE accumulation would provide a key constraint on the potential runoff during spring ablation while monitoring SWE disappearance rates would provide a key constraint on SWE partition into runoff vs. infiltration/recharge. [5] demonstrated that knowledge of early-spring SWE generally contributes most to streamflow forecast skill in the Western U.S. SWE is also a source of water storage that provides the water resources during spring snowmelt. Despite such potentially transformative contributions, accurate RZSM and SWE measurements are unattainable with current technology. While active/passive L-band methods (e.g. SMAP, SMOS) can reliably retrieve surface soil moisture in the top 5 cm of soil [6], [7]. RZSM estimates are only available through model assimilation of brightness temperatures with a radiative transfer and land surface models [8]. SWE estimation uses multi-frequency passive microwave techniques (e.g. [9]-[11]), which have significant problems with deeper snow and in forested and mountainous environments [12]. Signals of opportunity (SoOp) in P-band (200-400 MHz) is a new remote sensing technique with the capability of estimating both essential hydrologic variables, RZSM and SWE, circumventing many of the aforementioned limitations under all weather conditions day and night. SoOp is the re-utilization of existing powerful satellite transmissions within bands allocated for communications or navigation. P-band SoOp sensitivity to soil moisture has been demonstrated in an airborne experiment over Oklahoma in 2016 [13]. Recent theory [14] and experiments [15] have also confirmed that the reflection coefficient phase is proportional to SWE.

Garrison, J. L.↗

Io, its atmosphere and optical emissions

The paper outlines current understanding of phenomena associated with Io's atmosphere and optical emissions, along with a review of their relationships. The discussion covers the sodium D-line emission from Io, the ultraviolet emission observed from Pioneer 10, other optical emission lines, and future observational work on Io's line emission. Analysis of Io's ionosphere indicates that the atmosphere may be cooler than the observed sodium and that the exobase probably stands well above Io's surface. Also discussed is Io as a source of hydrogen and as a source of sodium. The observed electron profiles and the constraints provided by the emission cloud are consistent with two models of Io's neutral atmosphere. In the first model, hydrogen is supplied by dissociation of ammonia, whereas proton charge exchange is the primary source of hydrogen in the second model. Both models have the common feature that meteoritic impact or sputtering of the surface provides a source for sodium.

Brown, R. A.↗