Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shielding design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Expected performance of the FOOT experiment

The main objective of the FOOT (FragmentatiOn of Target) experimentis to measure the double differential cross-sections with respect to the kineticenergy and the angle of emission of fragments produced in nuclear interactions withan accuracy of 5%. Measurements will use the inverse kinematics approach to studythe interaction of heavy ions with proton-rich targets and will be performed in twoenergy regions, one up to 400 MeV/u, to assess the effects of nuclear fragmentationin hadrontherapy treatment with proton beams, and up to 700 MeV/u, to improvethe knowledge of the fragmentation of ions on nuclei to help with the design of spacevehicles shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

E906/SeaQuest MARS15 Simulation

The E906/SeaQuest spectrometer is designed to measure high energy muons produced in the forward direction by interactions of the 120 GeV Main Injector proton beam with a variety of targets. The spectrometer consists of two dipole magnets (both of which deflect charged particles in the horizontal plane) and a collection of tracking detectors. The first spectrometer magnet (FMAG) is a solid iron magnet. This magnet serves as a beam dump as well as a muon analysis magnet. A series of MARS15 simulations were done by Nikolai Mokhov to verify and guide the design of concrete shielding around FMAG and the target area immediately upstream of FMAG. The result of the fourth and last round of simulations is summarized here. This was a high statistics simulation that required approximately 48 cpu-weeks of computing time on the APC Energy Deposition Group cluster. The MARS15 simulation used a model of FMAG and its surroundings. The model includes air gaps in the concrete shielding, the largest of which are required because of the geometry of the saddle coils. A small volume surrounding the beam line just upstream of the magnet is filled with borated polyethylene. The borated polyethylene extends into the air gap necessitated by the saddle coils. With the exception of the top layer of six 'H' blocks, the concrete shielding is modeled in detail. The top layer of blocks are intended to shield the roof and downstream end of NM4 in the event of a loss of beam accident well upstream of the target; they provide only a small benefit in the normal running condition simulated by MARS.

43 PARTICLE ACCELERATORS↗

Analytical Results of MOX Colemanite Concrete Sample Poured July 25, 2012 -- Cured 28 Days

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use Colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Samples 8.1.2, 8.2.2, 8.3.2, and 8.4.2 were received on 8/1/2012 and analyzed after curing for 28 days. The average total density measured by the ASTM method C 642 was 2.09 g/cm 3 , within the lower bound of 1.88 g/cm 3 . The average partial hydrogen density was 7.48E-02 g/cm 3 as measured using method ASTM E 1311 and met the lower bound of 6.04E-02 g/cm 3 . The average measured partial boron density was 1.71E-01 g/cm 3 which met the lower bound of 1.65E-01 g/cm 3 measured by the ASTM C 1301 method.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Results Of MOX Colemanite Concrete Sample PBC-44.2

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Sample PBC-44.2 was received on 9/20/2012 and analyzed. The average total density measured by the ASTM method C 642 was 2.03 g/cm 3 , within the lower bound of 1.88 g/cm 3 . The average partial hydrogen density was 6.64E-02 g/cm 3 as measured using method ASTM E 1311 and met the lower bound of 6.04E-02 g/cm 3 . The average measured partial boron density was 1.97E-01 g/cm 3 which met the lower bound of 1.65E-01 g/cm 3 measured by the ASTM C 1301 method.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Results of MOX Colemanite Concrete Samples Poured August 29, 2012

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Samples poured 8/29/12 were received on 9/20/2012 and analyzed. The average total density of each of the samples measured by the ASTM method C 642 was within the lower bound of 1.88 g/cm 3 . The average partial hydrogen density of samples 8.6.1, 8.7.1, and 8.5.3 as measured using method ASTM E 1311 met the lower bound of 6.04E-02 g/cm 3 . The average measured partial boron density of each sample met the lower bound of 1.65E-01 g/cm 3 measured by the ASTM C 1301 method. The average partial hydrogen density of samples 8.5.1, 8.6.3, and 8.7.3 did not meet the lower bound. The samples, as received, were not wrapped in a moist towel as previous samples and appeared to be somewhat drier. This may explain the lower hydrogen partial density with respect to previous samples.

36 MATERIALS SCIENCE↗

Analytical Results of MOX Colemanite Concrete Samples Poured August 29, 2012

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Samples poured 8/29/12 were received on 9/20/2012 and analyzed. The average total density of each of the samples measured by the ASTM method C 642 was within the lower bound of 1.88 g/cm 3 . The average partial hydrogen density of samples 8.6.1, 8.7.1, and 8.5.3 as measured using method ASTM E 1311 met the lower bound of 6.04E-02 g/cm 3 . The average measured partial boron density of each sample met the lower bound of 1.65E-01 g/cm 3 measured by the ASTM C 1301 method. The average partial hydrogen density of samples 8.5.1, 8.6.3, and 8.7.3 did not meet the lower bound. The samples, as received, were not wrapped in a moist towel as previous samples and appeared to be somewhat drier. This may explain the lower hydrogen partial density with respect to previous samples.

36 MATERIALS SCIENCE↗

Analytical Results of MOX Colemanite Concrete Sample PBC-44.2

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. Sample PBC-44.2 was received on 9/20/2012 and analyzed. The average total density measured by the ASTM method C 642 was 2.03 g/cm 3 , within the lower bound of 1.88 g/cm3. The average partial hydrogen density was 6.64E-02 g/cm 3 as measured using method ASTM E 1311 and met the lower bound of 6.04E-02 g/cm 3 . The average measured partial boron density was 1.70E-01 g/cm 3 which met the lower bound of 1.65E-01 g/cm 3 measured by the ASTM C 1301 method.

36 MATERIALS SCIENCE↗

Analytical Results for MOX Colemanite Concrete Samples Received on January 15, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received twelve samples of colemanite concrete for analysis on January 15, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1311, and the average partial boron density of each sample was measured according to ASTM C 1301. The lower limits and measured values for the total density, hydrogen partial density, and boron partial density are presented. For all the samples tested, the total density and the hydrogen partial density met or exceeded the specified limit. All of the samples met or exceeded the boron partial density lower bound with the exception of samples G3-M11-2000-H, G3-M11-3000-M, and G5-M1-3000-H which are below the limit of 1.65E-01 g/cm 3 .

36 MATERIALS SCIENCE↗

Analytical Results for MOX Colemanite Samples Received on July 22, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the boron oxide content of the colemanite raw aggregate material prior to it being mixed into the concrete. SRNL received ten samples of colemanite for analysis on July 22, 2013. The elemental boron content of each sample was measured according to ASTM C 1301. The boron oxide content was calculated using the oxide conversion factor for boron.

36 MATERIALS SCIENCE↗

Analytical Results For MOX Colemanite Concrete Samples Received On September 4, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received three samples of colemanite concrete for analysis on September 4, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. The lower limits and measured values for the total density, hydrogen partial density, and boron partial density are presented. For all the samples tested, the total density and the boron partial density met or exceeded the specified limit. None of the samples met the lower limit for hydrogen partial density.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Results For MOX Colemanite Concrete Samples Received On November, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received two samples of colemanite concrete for analysis on November 21, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. For all the samples tested, the total density and the boron partial density met or exceeded the specified limit. None of the samples met the lower limit for hydrogen partial density.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Results for MOX Colemanite Concrete Samples Received on January 15, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received twelve samples of colemanite concrete for analysis on January 15, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. The lower limits and measured values for the total density, hydrogen partial density, and boron partial density are presented. For all the samples tested, the total density and the hydrogen partial density met or exceeded the specified limit. All of the samples met or exceeded the boron partial density lower bound with the exception of samples G3-M11-2000-H, G3-M11-3000-M, and G5-M1-3000-H which are below the limit of 1.65E-01 g/cm 3 .

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Results for MOX Colemanite Samples Received on July 22, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the boron oxide content of the colemanite raw aggregate material prior to it being mixed into the concrete. SRNL received ten samples of colemanite for analysis on July 22, 2013. The elemental boron content of each sample was measured according to ASTM C 1301. The boron oxide content was calculated using the oxide conversion factor for boron.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Results for MOX Colemanite Concrete Samples: Received on September 4, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received three samples of colemanite concrete for analysis on September 4, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. The lower limits and measured values for the total density, hydrogen partial density, and boron partial density are presented. For all the samples tested, the total density and the boron partial density met or exceeded the specified limit. None of the samples met the lower limit for hydrogen partial density.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analytical Results for MOX Colemanite Concrete Samples: Received on November 21, 2013

The Mixed Oxide Fuel Fabrication Facility (MFFF) will use colemanite bearing concrete neutron absorber panels credited with attenuating neutron flux in the criticality design analyses and shielding operators from radiation. The Savannah River National Laboratory (SRNL) is tasked with measuring the total density, partial hydrogen density, and partial boron density of the colemanite concrete. SRNL received two samples of colemanite concrete for analysis on November 21, 2013. The average total density of each of the samples measured by the ASTM method C 642, the average partial hydrogen density was measured using method ASTM E 1131, and the average partial boron density of each sample was measured according to ASTM C 1301. The lower limits and measured values for the total density, hydrogen partial density, and boron partial density are presented. For all the samples tested, the total density and the boron partial density met or exceeded the specified limit. None of the samples met the lower limit for hydrogen partial density.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2021 Report

In FY22, the participating Department of Energy (DOE) laboratories continued the work on the project “Gamma Spectrometry Code Rodeo for Uranium Enrichment”. Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) continued their efforts to acquire spectra using uranium sources. A collimator (with side and back shields) was custom designed and constructed at ORNL. Spectra were acquired at ORNL using the uranium enrichment standards supplied by New Brunswick Laboratory (NBL) and the collimated M400 detector. Spectra were also acquired using steel absorbers of different thickness placed between the source and the collimated M400 detector. The plan was to ship the collimator to LLNL so that spectra could be acquired using the LLNL detector in collimated geometries. This activity was suspended since problems were noticed with the performance of the LLNL M400 detector. Also, it was brought to light to the project team that some of the aspects of the M400 detector had been updated by the vendor H3D in response to requests by the IAEA. In February 2021, the ORNL and LLNL M400 detectors were returned to the H3D factory in order to resolve the problems with the LLNL detector and to update ORNL and LLNL detectors to the same configuration as the M400 supplied to the IAEA. H3D repaired the LLNL M400 and performed the IAEA updates on both the ORNL and LLNL detectors. ORNL and LLNL received the detectors in April 2021. Data acquisition was continued using the upgraded detectors. ORNL re-collected the spectra using point sources and the NBL standards in uncollimated and collimated geometries. The collimator was shipped from ORNL to LLNL. Spectra were acquired at LLNL through Q4 of FY22. When the ORNL spectra were examined closely, it became apparent that there were spurious artifacts present in some of the spectra. This rendered suspect the ORNL spectra collected in June/July 2021 time frame. ORNL contacted H3D and per H3D’s advice, the M400 detector was returned to H3D for repairs in mid-August 2021. H3D diagnosed the problem and established that the root cause was the extra tight packaging that created a strain on the CZT crystals, causing one of them to break down. The repaired M400 was returned to ORNL in early September 2021. ORNL re-started data acquisition for the third time. Data was continued to be acquired at ORNL and LLNL through September 2021. The ORNL and LLNL data will be shared with the principal investigators from the analyzing laboratories. The GADRAS code and FRAM have been developed to have the capability to analyze the M400 spectra. Good quality spectra from FY21 have been analyzed using modified versions of GADRAS and FRAM. The spectra have also been analyzed using the GEM code. The analysis results from GADRAS, FRAM and GEM codes are presented and discussed in this report. Some preliminary results from FRAM and GEM analysis were presented in February 2021 at the U-Pu Isotopics Workshop sponsored by the IAEA. CZTU code is being modified to analyze M400 spectra. Data collection, code development and analysis will be continued in FY22 as per the FY22 Project Work Plan (PWP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design to minimize indirect effects

Design criteria presented aimed at minimizing or eliminating the indirect effects of lightning. Certain premises were cited on which the criteria were based. Premises indicate that it is desirable to prevent irreversible damage to the aircraft, and that safety of the crew and vehicle is essential. Electronic equipment must be located in regions where the electromagnetic fields produced by lightning are lowest and must be designed with protective shielding.

Franklin A Fisher↗