Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Background cancellation for frequency-selective quantum sensing

A key challenge in quantum sensing is the detection of weak time dependent signals, particularly those that arise as specific frequency perturbations over a background field. Conventional methods usually demand complex dynamical control of the quantum sensor and heavy classical post-processing. We propose a quantum sensor that leverages time independent interactions and entanglement to function as a passive, tunable, thresholded frequency filter. By encoding the frequency selectivity and thresholding behavior directly into the dynamics, the sensor is responsive only to a target frequency of choice whose amplitude is above a threshold. This approach circumvents the need for complex control schemes and reduces the post-processing overhead.

Puig, Ricard [Los Alamos; Ecole Polytechnique, Lau↗

MEMS terahertz-to-infrared band converter using frequency selective planar metamaterial

A MEMS terahertz-to-infrared converter has been developed based on the unique properties of metamaterials that allow for selective control of the absorptivity and emissivity of the sensors. The converter consists of a sensing element structurally made of planar metamaterial membranes, connected to a substrate frame by four symmetrically-located thermal insulators. Upon THz absorption, the temperature of the sensing element increases and the outward infrared flux from the backside of the element is read by a commercial long-wave infrared camera. Two configurations were designed and fabricated with metamaterial absorptivity optimized for 3.8THz and 4.75THz quantum cascade lasers. The first sensor, fabricated with an oxidized aluminum backside, exhibits higher responsivity, but lower conversion efficiency than the second sensor, fabricated with a metamaterial backside. The spectral characteristics of the metamaterial on the two sides can be optimized to improve both responsivity and sensitivity, while keeping the sensors’ thermal time constant sufficiently small for real time imaging. No dedicated electronics or optics are required for readout making metamaterial-based MEMS THz-to-IR converters very attractive for THz imaging as means of a simple attachment to commercial IR cameras.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plastic recognition and electrogenic uniport translocation of 1 st -, 2 nd -, and 3 rd -row transition and post-transition metals by primary-active transmembrane P 1B-2 -type ATPase pumps

Transmembrane P 1B -type ATPase pumps catalyze the extrusion of transition metal ions across cellular lipid membranes to maintain essential cellular metal homeostasis and detoxify toxic metals. Zn(II)-pumps of the P 1B-2 -type subclass, in addition to Zn 2+ , select diverse metals (Pb 2+ , Cd 2+ and Hg 2+ ) at their transmembrane binding site and feature promiscuous metal-dependent ATP hydrolysis in the presence of these metals. Yet, a comprehensive understanding of the transport of these metals, their relative translocation rates, and transport mechanism remain elusive. We developed a platform for the characterization of primary-active Zn(II)-pumps in proteoliposomes to study metal selectivity, translocation events and transport mechanism in real-time, employing a “multi-probe” approach with fluorescent sensors responsive to diverse stimuli (metals, pH and membrane potential). Together with atomic-resolution investigation of cargo selection by X-ray absorption spectroscopy (XAS), we demonstrate that Zn(II)-pumps are electrogenic uniporters that preserve the transport mechanism with 1 st -, 2 nd - and 3 rd -row transition metal substrates. Promiscuous coordination plasticity, guarantees diverse, yet defined, cargo selectivity coupled to their translocation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectral Effects in Albedo and Rearside Irradiance Measurement for Bifacial Performance Estimation

We investigate the impact of spectral dependence of ground surface reflectivity on albedo and rearside irradiance measurements necessary for bifacial photovoltaic (PV) module performance estimation and monitoring. Because PV modules are spectrally selective, albedo and irradiance measurements performed with common irradiance sensors may require spectral mismatch corrections when used for performance prediction. We investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystalline silicon PV reference cells in comparison to a typical crystalline-silicon bifacial PV module. Simulations are performed for nine different representative ground surface materials using simulated solar spectra together with spectral reflectivity data distributed with the SMARTS simulation software. For the materials considered, the results show that albedo spectral mismatch relative to the bifacial module is distributed over a range of ±9.2% for thermopile pyranometers versus only ±3.7% for a typical PV reference cell. We consider the impact of this spectrally-responsive albedo mismatch on bifacial PV module rearside irradiance measurements. Using synthesized rearside spectral irradiance distributions, we find that for the nine different ground surface materials the predicted rearside irradiance measurement deviates from the effective irradiance observed by the PV module by on the order of 16.5 W/m 2 for the pyranometer and 3.6 W/m 2 for the PV reference cell. We discuss the implications for bifacial albedo and irradiance measurement.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Design and Validation of a Cryogenic Dilatometer

This project focuses on the design and development of a cryogenic dilatometer capable of measuring the thermal expansion of materials at extremely low temperatures. Understanding how materials change dimension with temperature is critical for applications involving cryogenic environments, particularly laminated systems housing superconducting magnets, where small dimensional changes can significantly affect performance and reliability. To address this, a dilatometer system was designed to operate within a liquid nitrogen environment while accurately measuring displacements caused by thermal contraction. The purpose of this device is to determine the coefficient of thermal expansion (CTE) of a material. The design process involved defining functional requirements, developing mechanical and thermal concepts for the measurement apparatus, selecting appropriate materials compatible with cryogenic temperatures, and integrating sensors capable of detecting small dimensional changes. The resulting system aims to provide a practical and repeatable method for evaluating material thermal expansion at cryogenic temperatures, supporting research into composite use in superconducting applications that require accurate characterization of material behavior in low-temperature environments.

Schmitt, Nicholas [Northern Illinois U.]↗

Image processing techniques and applications to the Earth Resources Technology Satellite program

The Earth Resources Technology Satellite system is studied, with emphasis on sensors, data processing requirements, and image data compression using the Fast Fourier and Hadamard transforms. The ERTS-A system and the fundamentals of remote sensing are discussed. Three user applications (forestry, crops, and rangelands) are selected and their spectral signatures are described. It is shown that additional sensors are needed for rangeland management. An on-board information processing system is recommended to reduce the amount of data transmitted.

Polge, R. J.↗

Applications of HCMM satellite data

The thermal properties of Lake Ontario as they relate to water equality, lake hydrology and energy exchange were investigated as well as the urban heat island problem in selected areas adjacent to the lake. The HCMM thermal sensor was fully calibrated for several underflight data. Actual surface water temperature maps were generated for all of Lake Ontario using the calibration procedure developed. Major water quality changes associated with the thermal bar as located by HCMM thermal data were observed from satellite and aerial data and verified by ground truth.

Source record↗

A four-lidar view of Cirrus from the FIRE IFO: 27-28 October 1986

The four ground-based lidar systems that participated in the 1986 FIRE IFO were configured in a diamond-shaped array across central and southern Wisconsin. Data were generally collected in the zenith pointing mode, except for the Doppler lidar, which regularly operated in a scanning mode with intermittent zenith observations. As a component of the cirrus case study of 27 and 28 October 1986 selected for initial analysis, data collected by the remote sensor ensemble from 1600 (on the 27th) to 2400 UTC (on the 28th) is described and compared. In general, the cirrus studied on the 27th consisted of intermittent layers of thin and subvisual cirrus clouds. Particularly at Wausau, subvisual cirrus was detected from 11.0 to 11.5 km MSL, just below the tropopause. At lower levels, occasional cirrus clouds between approx. 8.0 to 9.5 km were detected from all ground sites. Preliminary analysis of the four-lidar dataset reveals the passage of surprisingly consistent cloud features across the experiment area. A variety of types and amounts of middle and high level clouds occurred, ranging from subvisual cirrus to deep cloud bands. It is expected that the ground-based lidar measurements from this case study, as well as the airborne observations, will provide an excellent data base for comparison to satellite observations.

Sassen, Kenneth↗

Characterizing performance of ultra-sensitive accelerometers

An overview is given of methodology and test results pertaining to the characterization of ultra sensitive accelerometers. Two issues are of primary concern. The terminology ultra sensitive accelerometer is used to imply instruments whose noise floors and resolution are at the state of the art. Hence, the typical approach of verifying an instrument's performance by measuring it with a yet higher quality instrument (or standard) is not practical. Secondly, it is difficult to find or create an environment with sufficiently low background acceleration. The typical laboratory acceleration levels will be at several orders of magnitude above the noise floor of the most sensitive accelerometers. Furthermore, this background must be treated as unknown since the best instrument available is the one to be tested. A test methodology was developed in which two or more like instruments are subjected to the same but unknown background acceleration. Appropriately selected spectral analysis techniques were used to separate the sensors' output spectra into coherent components and incoherent components. The coherent part corresponds to the background acceleration being measured by the sensors being tested. The incoherent part is attributed to sensor noise and data acquisition and processing noise. The method works well for estimating noise floors that are 40 to 50 dB below the motion applied to the test accelerometers. The accelerometers being tested are intended for use as feedback sensors in a system to actively stabilize an inertial guidance component test platform.

Sebesta, Henry↗

Failure detection and isolation experiments with the Langley Mini-Mast

A report is presented on experiments to demonstrate failure detection and isolation (FDI) using the flexible truss facility Mini-Mast at the NASA Langley Research Center. Two techniques are selected for study because they are applicable both to sensor and actuator failures and because they do not depend on hypotheses about the forms of possible failures. These two are the method of generalized parity relations and the failure detection filter. These methods utilize the concept of analytical redundancy and therefore their performance depends on the fidelity of the model of the dynamics of the system being monitored. Results are given for sensor FDI using generalized parity relations and input-output data collected during operation of the Mini-Mast. component failures are simulated in the data. The dependence of the performance of the methods on choices of the parameters in their implementation is explored.

Vander Velde, Wallace E.↗

An optimal sensing strategy of a proximity sensor system for recognition and localization of polyhedral objects

An algorithm is presented for the recognition and localization of thre-dimensional polyhedral objects based on an optical proximity sensor system capable of measuring the depth and orientation of a local area of an object surface. Emphasis is given to the determination of an optimal sensor trajectory or an optimal probing, for efficient discrimination among all the possible interpretations. The determination of an optimal sensor trajectory for the next probing consists of the selection of optimal beam orientations based on the surface normal vector distribution of the multiple interpretation image (MII) and the selection of an optimal probing plane by projecting the MII onto the projection plane perpendicular to a selected beam orientation and deriving the optimal path on the projection plane. The selection of optimal beam orientation and probing plane is based on the measure of discrimination power of a cluster of surfaces of an MII. Simulation results are shown.

Lee, Sukhan↗

Sensor-model in-situ control of the RTM composite process

The paper reports on the use of in situ frequency dependent electromagnetic sensors (FDEMS) and the Loos resin transfer model to select and control the processing properties of an epoxy resin during RTM impregnation and cure. Once correlated with viscosity and degree of cure, FDEMS monitors the advancement of the resin, viscosity, and the impregnation of the fabric, allowing a direct means of monitoring in situ in the mold throughout the fabrication process the effects of time, temperature, vacuum, and pressure.

Kranbuehl, D. E.↗

Soft x ray window encapsulant for HgI2 detectors

HgI2 is an excellent semiconductor material for a low energy, room temperature x-ray spectrometer. The high values of the atomic numbers for its constituent elements gives high x-ray and gamma ray stopping power. The band gap of HgI2 is significantly higher than other commonly used semiconductors. Owing to the large value band gap, the leakage current for HgI2 devices is smaller, thus allowing low noise performance. Devices fabricated from HgI2 crystals have demonstrated energy resolution sufficient to distinguish the x-ray emission from the neighboring elements on the periodic table. Also the power requirements of HgI2 are very low. These characteristics make a HgI2 spectrometer an ideal component in a satellite based detection system. Unfortunately, HgI2 crystals tend to deteriorate with time, even if protected by standard semiconductor encapsulants. This degradation ruins the performance of the device in terms of its energy resolution and pulse amplitude. The degrading mechanism is believed to be material loss occurring from below the electrodes, due to high vapor pressure of HgI2 at room temperature. To address this major obstacle to rapid expansion of HgI2 technology, a research program aimed at improving device stability by encapsulation with inert polymeric materials was carried out. The program focused specifically on optimizing the encapsulant materials and their deposition techniques. The principal objectives for this program were device encapsulation, device testing, and accelerated testing to ensure very long term stability of these high resolution sensors. A variety of encapsulants were investigated with the selection criteria based on their chemical diffusion barrier properties, mechanical stability, reactivity, and morphology of encapsulant films. The investigation covered different classes of encapsulants including solvent based encapsulants, vapor deposited encapsulants, and plasma polymerized encapsulants. A variety of characterization techniques were employed to examine their effectiveness in stabilizing HgI2 devices; these included permeability evaluation, vacuum and heat testing, scanning electron microscopy (SEM) as well as studying the detector performance of coated detectors. The plasma polymerized films appear to have entirely solved the HgI2 degradation problem. Another achievement of this program was the development of an accelerated testing technique which correlates extremely well with long term tesing.

Entine, G.↗

In-Flight Calibration Methods for Temperature-Dependent Offsets in the MMS Fluxgate Magnetometers

During the first dayside season of the Magnetospheric Multiscale (MMS) mission, the in-flight calibration process for the Fluxgate magnetometers (FGM) implemented an algorithm that selected a constant offset (zero-level) for each sensor on each orbit. This method was generally able to reduce the amplitude of residual spin tone to less than 0.2 nT within the region of interest. However, there are times when the offsets do show significant short-term variations. These variations are most prominent in the nighttime season (phase 1X), when eclipses are accompanied by offset changes as large as 1 nT. Eclipses are followed by a recovery period as long as 12 hours where the offsets continue to change as temperatures stabilize. Understanding and compensating for these changes will become critical during Phase 2 of the mission in 2017, when the nightside will become the focus of MMS science. Although there is no direct correlation between offset and temperature, the offsets are seen for the period of any given week to be well-characterized as function of instrument temperature. Using this property, a new calibration method has been developed that has proven effective in compensating for temperature-dependent offsets during phase 1X of the MMS mission and also promises to further refine calibration quality during the dayside season.

Magnetic field reconnection↗

In-Flight Calibration of the MMS Fluxgate Magnetometers

We present an overview of the approach to in-flight calibration, which is a coordinated effort between the University of California Los Angeles (UCLA), Space Research Institute, Graz, Austria (IWF) and the NASA Goddard Space Flight Center (GSFC). We present details of the calibration effort at GSFC. During the first dayside season of the Magnetospheric Multiscale (MMS) mission, the in-flight calibration process for the Fluxgate magnetometers (FGM) implemented an algorithm that selected a constant offset (zero-level) for each sensor on each orbit. This method was generally able to reduce the amplitude of residual spin tone to less than 0.2 nT within the region of interest. However, there are times when the offsets do show significant short-term variations. These variations are most prominent in the nighttime season (phase 1X), when eclipses are accompanied by offset changes as large as 1 nT. Eclipses are followed by a recovery period as long as 12 hours where the offsets continue to change as temperatures stabilize. Understanding and compensating for these changes will become critical during Phase 2 of the mission in 2017, when the nightside will become the focus of MMS science. Although there is no direct correlation between offset and temperature, the offsets are seen for the period of any given week to be well-characterized as function of instrument temperature. Using this property, a new calibration method has been developed that has proven effective in compensating for temperature-dependent offsets during phase 1X of the MMS mission and also promises to further refine calibration quality during the dayside season.

Magnetic field reconnection↗

Predictive valve control system

A pressure control system may include a plurality of inflatable objects, each of the inflatable objects having a respective pressure sensor and a respective inflation valve, wherein each of the inflation valves has a behavior profile predictive of an amount of current used by the valve when operated. A valve controller of the system may have a pressure management circuit that receives information from the pressure sensors and is configured to automatically maintain a respective selected pressure in each of the inflatable objects by issuing commands to operate the inflation valves. An electrical current management circuit of the valve controller may be configured to predict, based on the valve behavior profiles, what effect the command would have on a total current usage, when executed, and automatically prevent any command that would cause the total current usage to exceed a maximum allowable current.

Piraner, Alexander↗

Design and analysis of graphene–MoS{sub 2} hybrid layer based SPR biosensor with TiO{sub 2}–SiO{sub 2} nano film for formalin detection: numerical approach

In this paper, a Surface Plasmon Resonance (SPR) biosensor has been numerically developed that used Graphene–MoS{sub 2}–Au–TiO{sub 2}–SiO{sub 2} hybrid structure for the detection of formalin. This developed sensor has been sensed the presence the formalin based on attenuated total reflection (ATR) method by observing the change of “surface plasmon resonance angle-the change of minimum reflectance attributor” and “the resonance frequency characteristics (RFC)-maximum transmittance attributor”. Chitosan has been used as probe sensing medium to accelerate particular reaction with the formalin. Here, graphene is used as biomolecular recognition element because of its high adsorption ability and optical characteristics which helps to improve sensor sensitivity, MoS{sub 2} used for it has larger band gap, high fluroscence quenching ability, higher optical absorption efficiency, TiO{sub 2}–SiO{sub 2} bilayer as the improvement of sensitivity and Gold (Au) as the sharp SPR curve. Numerical results give the impression that the variation of RFC and SPR angle for improper sensing of formalin is quiet negligible that confirms no formalin is detected whereas for proper sensing these change are considerably countable that confirms the detection of formalin. From the sensor sensitivity analysis, owing to add TiO{sub 2}–SiO{sub 2} bilayer with Graphene–MoS{sub 2} Hybrid layer, maximum sensitivity of 85.375% has been numerically resulted. This high sensor performance is for taking advantages of Graphene surface high selectively which detect bio molecular compounds through pi-stacking force, larger work function (5.1 eV) of MoS{sub 2} which allows the high sensitive detection of bio targets and Rich plasmon happens at the TiO{sub 2}–SiO{sub 2} interface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗