Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scaled testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Performance of Low Salinity Polymer Flood in Enhancing Heavy Oil Recovery on the Alaska North Slope

Combining low-salinity water (LSW) and polymer flooding was proposed to unlock the tremendous heavy oil resources (20–25 billion barrels) on the Alaska North Slope (ANS). The synergy effect of LSW and polymer flooding was demonstrated through coreflooding experiments carried out on representative rock and fluid systems. The results indicate that the high-salinity polymer solution (HSP, 2,300 ppm, salinity=27,500 ppm) requires nearly two thirds more polymer than the low-salinity polymer (LSP, 1,400 ppm, salinity=2,500 ppm) to achieve the same target viscosity of 45 cp measured from viscometer. Additional oil (5–9%) can be recovered from LSW flooding after extensive high-salinity water (HSW) flooding. LSW flooding performed in secondary mode can achieve higher recovery than in tertiary mode. Strikingly, LSP flooding can further improve the oil recovery by ~8% even after extensive HSP flooding with the same viscosity. LSP flooding performed directly after waterflooding can achieve ~10% more incremental oil recovery. The pH increase of the effluent during LSW/LSP flooding was significantly greater than that during HSW/HSP flooding, indicating the occurrence of ion exchange which might contribute to the improved oil recovery. Also, the water breakthrough was delayed in a low-salinity flood compared with a high-salinity flood. The idea of combining LSW and polymer flooding has been put into practice on a pattern-scale field pilot test in the target Milne Point field. Nearly two-year observation has shown impressive success: water cut reduction (70% to below 15%), increasing oil rate, and no polymer breakthrough so far. This work has demonstrated remarkable economical and technical benefits of combination of LSW and polymer flooding in enhancing heavy oil recovery.

Zhao, Yang↗

Experimental Investigation of Polymer-Induced Fouling of Heater Tubes in the First-Ever Polymer Flood on Alaska North Slope Part II

A polymer flood pilot has been ongoing in the Schrader Bluff viscous oil reservoir at Milne Point on the Alaska North Slope. The results from the pilot are encouraging. However, a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This work applies a multiexperimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids to determine safe operating conditions. Dynamic scale loop (DSL) tests were conducted to study fouling due to polymer at different skin temperatures (165–350°F) in a dynamic state of fluid flow where the fluids’ flow mimics the residence time of fluids in the heat exchanger of the field pilot. Static deposit tests were also conducted at similar skin temperatures of 165–250°F using a novel experimental apparatus designed and built in-house. It was found that at higher skin temperatures of 250–350°F, tube blocking was observed in the DSL tests, whereas the tests at 165–200°F did not show any tube blocking, even in a more extended test period. The deposit test showed that the deposit rate generally increases with skin temperature, and the presence of polymer aggravates the fouling. The copper tube performs best when the skin temperatures are 165–200°F, while the stainless steel tube performs best at a skin temperature of 250°F. These experiments also manifested the influence of the cloudpoint of the solution as the deposit rate increased significantly when the skin temperature was higher than the solution cloudpoint. The study provides a source of practical guidance to the field operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Load Control for Frequency Response - A Literature Review

As electricity grids employ greater fractions of renewable energy, which introduce additional variability and uncertainty in the net load, balancing electrical load and generation becomes more challenging. This paper reviews the literature documenting physical simulations and real systems that employ load control (LC) for frequency response and other grid services, which balance net load on the grid and prevent unwanted frequency excursions. Apart from academic and simulation studies, few sources exist on large-scale laboratory hardware testing or actual real-world systems that employ LC for frequency response, and we review them here. Four types of systems that we consider are: 1) Laboratory-based LC experiments, 2) Isolated microgrids that employ LC, 3) Larger grids that employ LC and 4) vehicle-to-grid (V2G) technology, using electric vehicles (EVs). In general, these systems have successfully used LC to meet their objectives, which are often keeping grid frequency within a required band. However, LC struggled to balance grid frequency in an isolated system powered by a single wind turbine, and V2G technology requires refinement in communication and control to provide optimal regulation that adheres to industry standards. As LC grows in the energy industry, we have three main recommendations: 1) encouraging system operators who use LC to publish system characteristics and lessons learned; 2) transitioning more LC theoretical/simulated systems to physical experiments, and physical experiments to real-world pilot systems; 3) demonstrating load control to support isolated, high-wind-contribution systems.

17 WIND ENERGY↗

2020 Hydrogen and Fuel Cell Technologies Market Report

This report features summaries of relevant hydrogen and fuel cell activity in 2020, consistent with prior annual reports across applications and sectors. However, 2020 was no ordinary year. Despite pandemic hardships, the hydrogen and fuel cell industry not only stepped up to assist with humanitarian and healthcare efforts but saw continued momentum in several growing market sectors with numerous partnerships, initiatives, and investments. Using hydrogen and fuel cell technologies to provide an environmental and economic pathway to clean, reliable power was a key feature of world economic recovery and energy infrastructure plans. Today, hydrogen energy and fuel cell systems are being developed and deployed in a range of stationary power, portable power, and transportation applications around the world. Throughout 2020, there were significant achievements in each sector, building on years of research and development (R&D), field testing, large-scale demonstration projects, and real-world customer experience. The heavy-duty truck market in particular continued to make substantial gains, with new players entering the space and a coalition of companies pledging to produce and deploy more than 100,000 fuel cell trucks in the next two decades. To provide hydrogen for trucks and other end users, larger and larger electrolyzer projects were announced throughout the year. Collectively, there were more than 430 megawatts (MW) of electrolyzer systems either deployed, ordered, or proposed around the world. This 2020 report also provides special “Spotlights” on the collective industry response to the COVID-19 pandemic as well as international commitments and hydrogen strategies, providing overviews of significant activity during and after the initial onset of COVID-19 around the world.

08 HYDROGEN↗

ANL Design Team Analysis: Transportable Modular Reactor by Balance of Plant Elimination

HolosGen LLC is developing “Holos-Quad” a transportable gas-cooled reactor, with integral load following power conversion systems equipping subcritical power modules (SPMs), fully comprised within standard transport containers. The design eliminates the Balance of Plant (BoP) and greatly simplifies the design layout. A closed-loop full Brayton gas thermodynamic cycle converts the fuel cartridges thermal energy into electricity. This ARPA-E project utilizes advanced reactor modeling tools and manufacturing-testing of a scaled SPM equipped with a surrogate fuel cartridge to eliminate the most significant technology gaps to accelerate commercialization. The Argonne Design Team contributes to the research by demonstrating feasibility of various aspects of the Holos-Quad design by performing high-fidelity neutronic modeling, and investigating various reactivity control systems. This work consists of two main tasks: evaluation of HolosGen’s design features and alternative options study for reactivity control.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reduced Temperature Cesium Removal from AP-101 Using Crystalline Silicotitanate

The Tank Side Cesium Removal (TSCR) system, currently operational under Washington River Protection Solutions LLC (WRPS), sends initial low-activity Hanford waste tank supernate feed to the Hanford Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility. In addition to entrained solids removal from the supernate, the primary goal of TSCR is to remove cesium-137 ( 137 Cs) by ion exchange, allowing contact handling of the liquid effluent product at the WTP. Crystalline silicotitanate (CST) ion exchange media, manufactured by Honeywell UOP, LLC (product IONSIV™ R9140-B), was selected as the ion exchange media at TSCR. Laboratory-scale ion exchange processing using TSCR prototypic unit operations continues to contribute toward WRPS establishing accurate process flowsheets for the individual feed campaigns planned for TSCR. This report describes the small-scale ion exchange testing with 14.0 L of diluted and filtered supernate from tank 241-AP-101 (AP-101DF) at 16 °C (62 °F) to demonstrate processing at temperature conditions that are more prototypic of what the TSCR system could experience during colder seasons of the year. Since CST Cs capacity increases with decreasing contact temperature, testing at the lower operating temperature will help to predict the maximum 137 Cs loading onto the CST in the TSCR system. One of the waste acceptance criteria (WAC) for the WTP Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AP-101DF tank waste to meet this criterion, only 0.144% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 694. Testing with AP-101DF matched TSCR prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the CST bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 62% Cs breakthrough after processing ~1400 BVs of feed; the 50% Cs breakthrough occurred at 1250 BVs. Testing compared to previous AP-107 testing at 16 °C showed ~80 BV increases in volume processed to reach the WAC limit for both lead and lag columns. A similar slope in breakthrough curves for both tests indicates similar kinetic behavior, with variations in feed matrices (Na and Cs concentrations) likely responsible for the deviations in reaching the WAC limit. The Cs effluent from the lag column reached the WAC limit after processing 875 BVs. Anticipating this breakthrough point, the polish column was preemptively installed at 770 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 5.32×10 0 µCi/mL, or 5.6 % Cs breakthrough, after processing all 1400 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First Ever Field Pilot on Alaska's North Slope to Validate the Use of Polymer Floods for Heavy Oil EOR a.k.a Alaska North Slope Field Laboratory (ANSFL)

Alaska’s high viscosity oil resources that range between 20–30+ billion barrels represent about a third of known North Slope original oil in place (OOIP). These resources are primarily concentrated in the Schrader Bluff formation (also called West Sak on the Western North Slope) and Ugnu reservoirs and are categorized as “viscous oils” and “heavy oils” owing to their in-situ viscosities between 5–10,000 cP and up to a million+ cP respectively. The viscous oil deposits are relatively deeper (2,000 – 5,000 ft), whereas the heavy oils are somewhat shallower (2,000 – 4,000 ft). The typically shallow depths and the proximity to the continuous permafrost results in relatively lower formation temperatures and pressures, and consequently higher viscosities. The vertical depth vs. viscosity delineated in Paskvan et al. (2016) differentiates the viscous and heavy oils. As depicted in Paskvan et al. (2016), currently the main focus (referred to as “developing”) is on the viscous oils in the Schrader Bluff formation in the Milne Point Unit (MPU). Notwithstanding this Alaska North Slope (ANS) specific categorization, we use the industry adopted, all-inclusive term “heavy oil” for all high viscosity oils. Resource characterization and additional details can be found in topical publications of Paskvan et al. (2016) and Targac et al. (2005). Despite the vast resource base, the development pace, vis-à-vis the production of heavy oils has been very slow and limited due to multiple factors such as cost, logistics, challenging arctic environment, poor waterflood sweep efficiency due to mobility contrasts, and significantly high minimum miscibility pressures (MMP). Most importantly, typical or standard thermal methods that are commonplace elsewhere (Canada, California) are inapplicable due to the continuous permafrost. As a consequence, cumulative production of heavy and viscous oils is a little over 1% of OOIP slope wide and currently, there is hardly any production from Ugnu. However, on a broader level, these unfavorable factors are outweighed by the fact that (1) these resources, within the established infrastructure, are too large to ignore because of their strategic importance to the Nation and the State of Alaska and (2) Prudhoe Bay type diluent crude oil is still available for heavy oil transport through the Trans Alaska Pipeline System (TAPS). Similarly, from a reservoir standpoint, the following factors also are important offsets: (1) favorable rock characteristics of Schrader Bluff; (2) the promise demonstrated by the initial scoping studies (Seright 2010, 2011) suggesting significant increase of heavy oil recovery using polymer flooding; (3) successful field implementation in Canada, China and elsewhere in the world, and (4) availability of the existing pairs of horizontal injector-producer in Schrader Bluff The foregoing was recognized as the best readily available opportunity for significant investment by the US Department of Energy and the field operator Hilcorp Alaska LLC to conduct the first ever field scale experiment to test the polymer flooding technology to unlock the vast heavy oil resources on ANS. With this primary goal in mind, the research team embarked on a ~4.5 years long project that focused on the field polymer pilot complemented by supporting laboratory and simulation studies. As documented in this final report, over the course of the project, many lessons have been learned and valuable field and supporting laboratory data has been collected, which also is complemented by numerical reservoir simulations. We have been able to establish the injectivity of polymer solution, evidence of significant reduction in the water cut of previously waterflooded pattern, effective propagation of a hydrolyzed polyacrylamide (HPAM), benefits of low salinity water, provide practical guidance on handling of produced fluids containing breakthrough polymer, fit-for-purpose forecast-worthy history matched simulation model, polymer EOR benefit of 700-1000 bopd over waterflood, and most importantly a low polymer utilization factor of ~1.7 lb/stb. In summary this project is deemed as a scientific, technical and economic success, having met all objectives, fulfilled deliverables and within budget, providing impetus to apply polymer EOR throughout the Milne Point Field paving the way for even heavier viscosity oils in the Ugnu area, eventually extending the economic life of TAPS.

02 PETROLEUM↗

DES-Y3 galaxies & ACT DR4 CMB lensing tomography

We present a measurement of the cross-correlation between the \maglim galaxies selected from the Dark Energy Survey (DES) first three years of observations (Y3) and cosmic microwave background (CMB) lensing from the Atacama Cosmology Telescope (ACT) Data Release 4 (DR4), reconstructed over $\sim 436$ $\sqdeg$ of the sky. Our galaxy sample, which covers $\sim 4143$ $\sqdeg$, is divided into six redshift bins spanning the redshift range of $0.20<z<1.05$. We adopt a blinding procedure until passing all consistency and systematics tests. After imposing scale cuts for the cross-power spectrum measurement, we reject the null hypothesis of no correlation at 9.1$\sigma$. We constrain cosmological parameters from a joint analysis of galaxy and CMB lensing-galaxy power spectra considering a flat \LCDM model, marginalized over 23 astrophysical and systematic nuisance parameters. We find the clustering amplitude $S_8\equiv \sigma_8 (\Omega_m/0.3)^{0.5} = 0.75^{+0.04}_{-0.05}$. In addition, we co nstrain the linear growth of cosmic structure as a function of redshift. Our results are consistent with recent DES Y3 analyses and suggest a preference for a lower $S_8$ compared to results from measurements of CMB anisotropies by the \textit{Planck} satellite, although at a mild level ($< 2 \sigma$) of statistical significance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cesium Removal from SY-101 Tank Waste Using Crystalline Silicotitanate

The newly operational Tank Side Cesium Removal (TSCR) system removes radioactive cesium-137 ( 137 Cs) and solids from tank waste supernate in the 200 east area of the Hanford site. Efforts to expand the removal capabilities to the 200 west area are underway by a system anticipated to be called the West Area Risk Management (WARM) system. Laboratory-scale ion exchange processing using expected WARM unit operations were conducted to contribute toward Washington River Protection Solutions (WRPS) establishing accurate process flowsheets for the individual feed campaigns planned for the west area supernate pretreatment. This report describes the small-scale ion exchange testing with 8.0 L of filtered supernate from tank 241-SY-101 (referred to as SY-101) at 16 °C (62 °F) to demonstrate processing conditions that would be prototypic of what the WARM system may experience. One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the SY-101 tank waste to meet this criterion, only 0.44% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 227. Testing with SY-101 matched current TSCR prototypic operations where a lead-lag configuration is used until the lag column reached the WAC limit. Neither the lead nor lag columns reached the WAC, so a polish column was never utilized during this test. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitate (CST) bed, matched the current flowrate at TSCR (an expected flowrate to be used at WARM). The lead column only reached 0.09% Cs breakthrough after processing ~1363 BVs of feed. Cesium breakthrough from the lag column was not observed during the entire processing. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics. Table S.1 and Figure S.1 also summarize the measured SY-101 Cs load performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ML-based Data Assimilation and History Matching: Application to the IBDP CCS Project

It is crucial to monitor the CO2 plume effectively throughout the life cycle of a geologic CO2 sequestration project to ensure safety and storage efficiency. However, the computational cost of existing data assimilation methods can be prohibitively expensive due to the complex physics with multi-component non-isothermal simulation and high dimensionality of large-scale reservoir models. We address this challenge by proposing an accelerated deep learning-based workflow for model calibration and prediction of CO2 plume evolution in the reservoir.The power and efficacy of our workflow is demonstrated by application to the Illinois Basin-Decatur Project (IBDP), a large-scale CO2 storage test in saline aquifer. The data assimilation process is implemented rapidly by the proposed workflow with given field measurements including distributed pressure and temperature sensing (DTS) data at an injection and a monitoring well. CO2 plume evolution is predicted by running the simulations of the calibrated reservoir models.

Nagao, Masahiro↗

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

Development of a self-lubricating high-efficiency hybrid seal composed of carbon nanotube-coated metal meshes for CSP turbomachinery (SETO CPS #36333 Final Report)

In turbomachinery, internal leakage flow accounts for up to 3% of the total thermodynamic cycle energy loss. Tradeoff must be made between the sealing efficiency (smaller clearance) and the friction and wear issues for interfering with the shaft (larger clearance). This ORNL-Danfoss joint effort developed a novel hybrid seal composed of carbon nanotube (CNT)-coated metal meshes. The CNT growth process was based on a self-catalyzing chemical vapor deposition and these multiwall CNTs were well aligned with high crystallinity. This hybrid material structure takes advantage of the CNT’s low-friction nature and uses the metal mesh as an extendable backbone. Full-scale experimental seals were designed, fabricated, and optimized for sealing performance and durability. The CNT-coated metal mesh seal demonstrated superior gas sealing efficiency to the baseline labyrinth seal and significantly improved shaft surface protection compared with the state-of-the-art superalloy brush seal on the static rig and full-scale compressor dynamometer tests. The CNT-metal mesh seal is low-cost and scalable and can potentially benefit wide applications, including CSP and other power generation, marine, automotive, and HVAC.

36 MATERIALS SCIENCE↗

Ion Exchange Processing of AN-107 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AN-107 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 13.7 L of diluted and filtered supernate from Tank 241-AN-107 (hereafter referred to as AN-107) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AN-107 tank waste to meet this criterion, only 0.147% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 678. Testing with AN-107 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 40% Cs breakthrough after processing ~1700 BVs of feed; the 50% Cs breakthrough was extrapolated from the breakthrough data to occur at 1873 BVs. Testing compared to previous AP-101 and AP-107 testing at 16 °C showed ~300 BV increases in volume processed to reach the WAC limit for both lead and lag columns. The increase in capacity was determined to be due to the significantly lower K concentration in the AN-107 compared to the other tank waste matrices. A comparison in breakthrough curves for the three tests indicated slightly slower kinetic behavior in the AN-107, with variations in feed matrices (high organic complexants) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 1097 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 900 BVs. Cs breakthrough from the lag column began at 500 BVs, reaching 3.06×10 0 µCi/mL, or 2.6 % Cs breakthrough, after processing all 1700 BVs of feed. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ion Exchange Processing of AW-105 Hanford Tank Waste through Crystalline Silicotitanate in a Staged 2- then 3-Column System

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) Program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the small-scale ion exchange testing with 9.2 L of diluted and filtered supernate from Tank 241-AW-105 (hereafter referred to as AW-105) at 16 °C (62 °F). One of the waste acceptance criteria (WAC) for the Waste Treatment Plant (WTP) Low-Activity Waste Facility is that the waste must contain less than 3.18×10 -5 Ci 137 Cs per mole of Na. For the AW-105 tank waste to meet this criterion, only 0.225% of the influent 137 Cs concentration may be delivered to the WTP; this requires a Cs decontamination factor of 445. Testing with AW-105 matched current Tank Side Cesium Removal (TSCR) facility prototypic operations where a lead-lag configuration was used until the lag column reached the WAC limit, then a polish column was brought online for continued processing in a lead-lag-polish column configuration. Feed was processed at 1.9 bed volumes (BVs) per hour; the flowrate, in terms of contact time with the crystalline silicotitanate (CST) bed, matched the expected flowrate at TSCR. The Cs-decontaminated product was retained for vitrification testing (to be reported separately). The lead column reached 83% Cs breakthrough after processing ~1500 BVs of feed; the 50% Cs breakthrough was interpolated from the breakthrough data and occurred at 1041 BVs. Despite the AW-105 having a significantly higher K concentration (0.55 M compared to 0.10 M), testing compared to previous AP-107 ion exchange column testing at 16 °C showed no difference in BVs processed to reach the WAC on the lead column and only an approximate ~20 BV decrease in volume processed to reach the WAC limit on the lag column. The negligible differences in capacity despite the 5x concentration differences in K was determined to be due to the significantly lower NO3 concentration in the AW-105 supernate compared to the AP-107 tank waste matrix. A comparison in breakthrough curves for the two tests also indicated slightly faster kinetic behavior in the AW-105, with the variations in feed matrices (lower NO3 concentration) likely responsible for the deviation. The Cs effluent from the lag column reached the WAC limit after processing 772 BVs. Anticipating this breakthrough point, the polish column was preemptively installed around 675 BVs. Cs breakthrough from the lag column began at 300 BVs, reaching 1.10×10 1 µCi/mL, or 14.13 % Cs breakthrough, after processing all 1500 BVs of feed. The polish column processed nominally 830 BVs and reached 2.10×10 -1 µCi/mL, or 0.27 % Cs breakthrough at the conclusion of the test. Table S.1 and Figure S.1 summarize the observed column performance and relevant Cs loading characteristics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comprehensive Comparison of Methods for Evaluating Dispatch of Long-Duration Energy Storage in Power Systems Models

Long-duration energy storage (LDES) could play a pivotal role in the transformation of electricity grids with high shares of variable renewable energy (VRE) such as solar and wind. However, the weather-dependent nature of VRE introduces challenges for grid balancing and stability, which LDES - along with short-duration energy storage (SDES) - can help address. However, modeling LDES in production cost models (PCMs) is particularly challenging due to the need for high temporal resolution over extended optimization windows while preserving chronology, which ensures the alignment of energy storage operations with VRE generation over multi-day periods. This report compares traditional dispatch methods with advanced LDES dispatch strategies, such as the extended horizon approach, across different PCM platforms and examines tradeoffs and scalability. The comparison reveals that the traditional 1-day optimization horizon within the PCM leads to inefficient utilization of LDES. In contrast, extending the optimization horizon as much as possible significantly reduces curtailment and improves storage dispatch, especially in renewable-dense systems. There is also promise in using state-of-charge or end volume targets set by an external model, however this requires an additional modeling set and generally increases computational burden. This paper presents a comparison of these various methods in a number of power systems, showing algorithms initially in small test systems and scaling up to large, country-wide simulations. Overall, the research presents the trade-offs of various computational methods and illustrates how LDES may play an essential role in power systems of the future.

14 SOLAR ENERGY↗

Dynamical System Scaling of a Thermocline Thermal Storage System in the Thermal Energy Distribution System (TEDS) Facility

The purpose of this study was to develop a process to convert input signals from one facility into another by reflecting geometric and environmental settings. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility in development that aims to emulate the daily interactions among power production industry systems and be capable of receiving real-time data from those systems as inputs. To convert signals and ensure that the temporal sequences and magnitudes reflect the laboratory settings, the ability to scale and project data is essential. To demonstrate this ability, Dynamical System Scaling (a methodology that enables systems to scale and project or extrapolate datasets to desired environments while conserving the observed transient behavior based on first principles) was applied to DETAIL’s thermocline thermal storage system in the Thermal Energy Distribution System. The thermocline system was successfully scaled and a test case was conducted to generate a doubly accelerated energy charge and discharge in reference to past experimental data from the facility. The accelerated data were determined as able to conserve the amount of energy stored and the associated test boundary conditions were charge line maximum temperature, charge line velocity, and thermocline maximum temperature at 354 °C, 0.458 m/s, and 418 °C, respectively. The research results represented a case that required signals to be accelerated without altering the stored energy.

Yoshiura, Ramon (ORCID:0000000319781313)↗

Effects of Accident Thermal Loading on In-Plane Shear Behavior of Steel-Plate Composite Walls

Structural walls in safety-related nuclear facilities are required to be designed for seismic and accident thermal (due to postulated high-energy pipe break events) loading combination. Current U.S. and international codes provide limited guidance for analysis and design of walls for this loading combination. This paper describes the experimental results and observations from tests conducted on a laboratory-scale (1:4 to 1:5) test unit representing steel-plate composite (SC) walls subjected to combined in-plane (seismic) and accident thermal loading. The test unit was subjected to surface temperatures of up to 450°F in combination with cyclic in-plane loading. Results of similar experiments recently conducted in Japan are also summarized (with surface temperatures up to 570°F). Surface heating combined with the low thermal conductivity and high specific heat of concrete resulted in nonlinear thermal gradients through the thickness of the specimens. These nonlinear thermal gradients and the associated self- or internal restraint led to extensive concrete cracking. This concrete cracking reduced the initial and secant stiffness of the specimens. The initial stiffness of the heated specimens reduced to 30 to 40% of the initial stiffness of the control (unheated) specimen. The secant stiffness of the heated specimens reduced up to 50% of the secant stiffness of the control (unheated) specimen. However, the in-plane shear strength of the heated SC specimens was still approximately 10 to 30% greater than the nominal in-plane shear strength calculated, for the limit state of steel plate von Mises yielding, using AISC N690 equations and measured material properties. Evaluation of the experimental results and observations suggests that the in-plane shear strength of SC walls subjected to typical accident surface temperatures (up to 570°F) can be estimated conservatively using the current provisions of AISC N690. The stiffness for accident thermal loading combinations can be considered to reduce from cracked composite stiffness at ambient temperature to fully cracked—that is, steel-only stiffness as the surface temperature increases up to typical accident value.

Construction & Building Technology↗

Thermal Storage Performance of a Dual-Purpose Underground Thermal Battery for Shaping the Electric Demand of Buildings

A dual-purpose underground thermal battery (DPUTB) integrates a ground heat exchanger with underground thermal energy storage. It can be installed in shallow boreholes (less than 6 m deep) and thus is less expensive than the conventional ground heat exchangers. The thermal energy storage can be used to shave or shift the electric load for meeting the thermal demands of a building. The charging and discharging performance of a lab-scale DPUTB were tested. The test results show that the DPUTB can be fully charged within 4 h and can provide 34 W cooling continuously for 2.5 h with a supply water temperature below 14°C. A small amount of phase-change material significantly increased the thermal storage capacity.

Wang, Lingshi↗