ARM: Pixels from SASHe corresponding to MFR radiometer wavelengths
Pixels from SASHe corresponding to MFR radiometer wavelengths
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Pixels from SASHe corresponding to MFR radiometer wavelengths
The microwave radiometer profiler (MWRP) provides vertical profiles of temperature, humidity, and cloud liquid water content as a function of height or pressure at approximately 5-minute intervals for nearly all weather conditions. The profiles are derived from measurements of absolute microwave radiances (expressed as "brightness temperatures") obtained at 12 frequencies in the range of 22-30 GHz and 51-59 GHz. The data are useful for input to numerical weather forecast models and others that require continuous, high-temporal-resolution profiles. The microwave radiance measurements are useful for testing models of microwave radiation transfer used to derive the profiles.
Multi-Filter Radiometer (MFR) with 7 Narrowband Channels: upwelling irradiance at 36-meter height
Radiometer-pyrometer measures the spectral absorption, emission, and temperature of gases. The major problems involved in spectroradiometric measurements are nonuniform spectral sensitivity, nonlinearity, poor absolute accuracy, wide range of intensities, and wide range of wavelengths.
Fast response, spectrally linear standard detector in the form of a blackbody cavity radiometer calibrates rapidly responding photodetectors against a calibrated standard detector. A power amplifier with maximum available gain reduces error signal without stability loss. It may be used as a blackbody radiator by manipulation of the bridge variable arm.
Anisotropy in albedo of low stratiform clouds measured by Tiros IV scanning radiometers
Design, performance and operation of high- resolution IR radiometer mounted on Nimbus satellite
High resolution IR radiometer on Nimbus I satellite for providing detailed night cold information
Radiometer may be used either with an f/16 telescope to measure thermal radiation from the surface of the dark moon or with a short-range optical system to measure thermal radiation from laboratory samples.
The responsiveness of a foil radiometer is increased and its time constant is simultaneously decreased by isolating the foil in a controlled environment. Using an optical system, it is coupled to the media to be measured, and the resulting concentration of energy permits the thermocouple junction temperature to respond quickly.
Conical cavity-type absolute radiometer measures the intensity of radiant energy to an accuracy of one to two percent in a vacuum of ten to the minus fifth torr or lower. There is a uniform response over the ultraviolet, visible, and infrared range, and it requires no calibration or comparison with a radiation standard.
Radio Astronomy Explorer satellite radiometer system for measuring spectral energy distribution of solar bursts
Grid method for constructing scan lines generated by Tiros scanning radiometers
Calibration, system, subsystem, and components of microwave radiometer for Nimbus satellite
Microwave radiometer design criteria for Nimbus satellites
Tiros medium resolution scanning radiometer data from short and long wavelengths used to estimate cloud top temperatures, cloud cover, emissivity, and equivalent black body temperatures
Thermal testing of two stage radiant cooler for day-night high resolution infrared radiometer
Single channel airborne infrared radiometer and calibration black body