Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Cascaded systems analysis of photon counting detectors

Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.

60 APPLIED LIFE SCIENCES↗

Imaging Interfacial Electric Fields on Ultrafast Timescales (Final Report)

The goal of this project is to dynamically probe interfacial electric fields on ultrafast timescales and sub-micron length scales. The proposed method could be applied to a variety of heterointerfaces, with particular emphasis on interfaces involving colloidal quantum dots. The primary objective is development of an ultrafast nonlinear optical imaging technique with this capability. A secondary objective is obtaining new insights into excited state charge carrier dynamics in colloidal quantum dot solids and at quantum dot interfaces. Research activities involve validation of the technical approach, construction of the microscope, and synthesis and characterization of materials to be studied using the instrument.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Induction-detection electron spin resonance with spin sensitivity of a few tens of spins

Electron spin resonance (ESR) is a spectroscopic method that addresses electrons in paramagnetic materials directly through their spin properties. ESR has many applications, ranging from semiconductor characterization to structural biology and even quantum computing. Although it is very powerful and informative, ESR traditionally suffers from low sensitivity, requiring many millions of spins to get a measureable signal with commercial systems using the Faraday induction-detection principle. In view of this disadvantage, significant efforts were made recently to develop alternative detection schemes based, for example, on force, optical, or electrical detection of spins, all of which can reach single electron spin sensitivity. This sensitivity, however, comes at the price of limited applicability and usefulness with regard to real scientific and technological issues facing modern ESR which are currently dealt with conventional induction-detection ESR on a daily basis. Here, we present the most sensitive experimental induction-detection ESR setup and results ever recorded that can detect the signal from just a few tens of spins. They were achieved thanks to the development of an ultra-miniature micrometer-sized microwave resonator that was operated at ∼34 GHz at cryogenic temperatures in conjunction with a unique cryogenically cooled low noise amplifier. The test sample used was isotopically enriched phosphorus-doped silicon, which is of significant relevance to spin-based quantum computing. The sensitivity was experimentally verified with the aid of a unique high-resolution ESR imaging approach. These results represent a paradigm shift with respect to the capabilities and possible applications of induction-detection-based ESR spectroscopy and imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of Scintillation Detectors Based on Quantum Dots in a Semiconductor Matrix (Final Technical Report)

InAs Quantum Dots (QDs) embedded into GaAs semiconductor waveguide have unique scintillation properties, valuable for nuclear security, medical imaging, and high energy physics. In this work, we developed thick (~25um) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. In this type of detector, the GaAs matrix acts as a stopping material for charged particles or photons generating electrons captured by the QDs acting as luminescence centers. The QD medium is designed to provide fast capture of electrons into QDs (few ps), high QD luminescence efficiency at room temperature (>50%), and strong red-shift of photoluminescence (PL) from the GaAs absorption edge (>250nm). Typical devices consist of a 10-25um thick GaAs layer with embedded sheets of modulation p-type doped InAs QDs and an InGaAs photodetector tuned to the QD emission wavelength. The thick GaAs layer acts also as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (~1cm -1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with both an external photodiode (PD) and an integrated PD which provided an improved optical coupling. In the former case, the external InGaAs PD was air-coupled to the scintillator and had the light collection efficiency of about 1% corresponding to limited light extraction through a planar interface with air due to total internal reflection. The mean charge collected by the integrated PD was in the range of (3÷5)×10 4 photoelectrons per 1 MeV of deposited energy, or ~13-20% of the theoretically achievable light yield. Timing of the integrated device was measured by wire-bonding it to the input of an 8 GHz IC. The scintillation response shows an extremely fast 0.3-0.6 ns decay constant and about 40-70 ps time resolution, limited by the system noise. The combined light yield and decay time makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported making it valuable for high energy physics and medical imaging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microchannel Plate Imaging Detectors for the Ultraviolet

There has been significant progress over the last few years in the development of technologies for microchannel plate imaging detectors in the Ultraviolet (UV). Areas where significant developments have occurred include enhancements of quantum detection efficiency through improved photocathodes, advances in microchannel plate performance characteristics, and development of high performance image readout techniques. The current developments in these areas are summarized, with their applications in astrophysical instrumentation.

Siegmund, O. H. W.↗

Electrochemical Degradation Modes in Bifacial Silicon Photovoltaic Modules

Motivated by the rapidly rising deployment of bifacial monocrystalline-silicon photovoltaics (PV), we investigate the durability of various PV module packaging configurations with transparent coverings on both the front and rear sides of the module. We use a series of bifacial passivated emitter and rear cell (p-PERC) mini-modules with systematically varying outer cover materials (glass/glass, G/G, or glass/transparent backsheet, G/TB) and encapsulant chemistries (poly [ethylene-co-vinyl acetate], EVA; or polyolefin, POE). We study degradation modes over 1,000 hours of combined damp heat (DH) exposure and high system voltages that can cause potential-induced degradation (PID) under positive, zero, or negative 1,000 V cell-to-frame bias. We analyze the degradation modes using a combination of current-voltage measurements, impedance spectroscopy, external quantum efficiency, and spatially resolved luminescence and thermal imaging. Our results highlight various types of degradation including shunting, enhanced recombination, and series resistance increases, and we use spatially resolved characterization to separately identify the localized effects. We show that multiple PID and moisture-ingress degradation modes severely affect EVA-containing modules, with previously reported PID processes under negative-bias DH and a unique observation of rear-side surface recombination in G/EVA/G modules under positive-bias DH. We observe significantly less degradation in POE-containing modules, where the G/POE/G configuration exhibits minimal degradation under all stress conditions that we employ.

14 SOLAR ENERGY↗

Effect of annealing on SiO{sub x}-TiO{sub 2} axial heterostructure nanowires and improved photodetection

Glancing angle deposition technique has been used to synthesize the axial heterostructure SiO{sub x}-TiO{sub 2} nanowires (NWs) on the Si substrate. The field emission gun scanning electron microscope image shows the formation of perpendicular NWs on Si substrate. A typical transmission electron microscope image confirms the heterostructure NW which consists of SiO{sub x} of length ∼130 nm and TiO{sub 2} of length ∼170 nm. The amorphous NWs transformed to polycrystalline nature after annealing. The trap assisted radiative recombination process is absent for the annealed NWs. An averagely 1.1 fold enhanced photoabsorption was exhibited by the annealed NWs in the 200–350 nm region and 1.5 fold in the 500–850 nm region. The leakage current (2.6 × 10{sup −8} A/cm{sup 2} at −0.5 V) significantly reduced for annealed NWs device. A maximum 1.4 × 10{sup 3} times enlarged photodetection has been observed for annealed device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing cold nuclear matter with energy correlators

The future electron-ion collider (EIC) will produce the first-ever high energy collisions between electrons and a wide range of nuclei, opening a new era in the study of cold nuclear matter. Quarks and gluons produced in these collisions will propagate through the dense nuclear matter of nuclei, imprinting its structure into subtle correlations in the energy flux of final state hadrons. In this article, we apply recent developments from the field of jet substructure, namely the energy correlator observables, to decode these correlations and provide a new window into nuclear structure. The energy correlators provide a calibrated probe of the scale dependence of vacuum quantum chromodynamics (QCD), enabling medium modifications to be imaged and interpreted as a function of scale. Using the eHIJING parton shower to simulate electron-nucleus collisions, we demonstrate that the size of the nucleus is imprinted as an angular scale in the correlators, with a magnitude that is visible for realistic EIC kinematics. We can observe the size difference between the proposed EIC nuclear targets 3 He, 4 He, 12 C, 40 Ca, 64 Cu, 197 Au, and 238 U, showing that the energy correlators can image femtometer length scales using asymptotic energy flux. Our approach offers a unified view of jet substructure across collider experiments, and provides numerous new theoretical tools to unravel the complex dynamics of QCD in extreme environments, both hot and cold.

Electron-ion collisions↗

Photoelectron angular distributions from polarized Ne{sup *} atoms near threshold

Photoelectron distributions of the polarized 2p{sup 5}3d Rydberg states of neon have been studied with a newly built velocity map imaging analyzer. The atoms were polarized by absorption of synchrotron radiation and ionized by an infrared laser. The asymmetry parameters {beta}{sub 2} and {beta}{sub 4} characterizing two-photon resonant ionization have been extracted from the measured images and compared with the results of a quantum defect treatment. To achieve a good theoretical description of the data, it is necessary to take into account the dependence of the dipole transition matrix elements and phases of the partial waves on the angular momentum quantum numbers pertaining to various continuum channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning for improved current-density reconstruction from two-dimensional vector magnetic images

The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high-spatial-frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional images of vector magnetic fields acquired by a quantum diamond microscope . Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower-signal-to-noise-ratio data, significantly reducing the data collection time and permitting reconstructions of weaker and three-dimensional current sources. Published by the American Physical Society 2025

Reed, Niko R. (ORCID:0009000305222403)↗

Vesicle Photonics

Thin membranes, under appropriate boundary conditions, can self-assemble into vesicles, nanoscale bubbles that encapsulate and hence protect or transport molecular payloads. In this paper, we review the types and applications of light fields interacting with vesicles. By encapsulating light-emitting molecules (e.g. dyes, fluorescent proteins, or quantum dots), vesicles can act as particles and imaging agents. Vesicle imaging can take place also under second harmonic generation from vesicle membrane, as well as employing mass spectrometry. Light fields can also be employed to transport vesicles using optical tweezers (photon momentum) or directly pertrurbe the stability of vesicles and hence trigger the delivery of the encapsulated payload (photon energy).

Vasdekis, Andreas E.↗

On-Shot Focal-Spot Characterization Technique Using Phase Retrieval

We present an on-shot focal-spot characterization technique based on a phase-retrieval scheme that retrieves near-field phase from multiplane focal-spot measurements in an experimental target chamber. The technique is easy to implement inside a target chamber and is demonstrated in a multiterawatt laser system. It is also found that phase retrieval can quantitatively detect residual angular dispersion coming from the pulse compressor misalignment.

Bahk, S -W↗

Dust and gas jets: Evidence for a diffuse source in Halley's coma

The distribution of dust-scattered intensity in Halley's inner coma is measured with the Vega three-channel spectrometer at three selected wavelengths: 377, 482, and 607 nm. The variation along a cometo-centric radius may be described by a p(sup -s) law where p is the distance between nucleus and optical axis and s is an exponent which is equal to 1 except in an intermediate 3000 less than p less than 7000 km region where s = 1.5. The shape of the radial distribution may be explained with a model including solar radiation pressure effect and quantum scattering efficiencies calculated from Mie theory. Monochromatic images inside an angular sector having its apex at the nucleus show evidence of two dust jets which extend to 40,000 Km. The pixel-to-pixel ratio of two images of dust intensity at 377 and 482 nm shows that the scattered intensity presents an excess of blue coloration in a zone located around the jets between 10,000 and 25,000 km. This coloration is interpreted as being due to a population of sub-micronic grains which result of the fragmentation of dust particles transported in the jets. It is suggested that the diffuse source where an additional quantity of CO was detected might be connected with the presence of a dust jet. In the present scheme, grain particles with a size of several micron or 10 micron would be transported inside a dust jet to distances of several 10,000 km where they would suffer fragmentation and produce sub-micronic particles and a release of gas which would be at the origin of the diffuse source.

Clairemidi, Jacques↗

Speckle imaging with the MAMA detector: Preliminary results

We report on the first successful speckle imaging studies using the Stanford University speckle interferometry system, an instrument that uses a multianode microchannel array (MAMA) detector as the imaging device. The method of producing high-resolution images is based on the analysis of so-called 'near-axis' bispectral subplanes and follows the work of Lohmann et al. (1983). In order to improve the signal-to-noise ratio in the bispectrum, the frame-oversampling technique of Nakajima et al. (1989) is also employed. We present speckle imaging results of binary stars and other objects from V magnitude 5.5 to 11, and the quality of these images is studied. While the Stanford system is capable of good speckle imaging results, it is limited by the overall quantum efficiency of the current MAMA detector (which is due to the response of the photocathode at visible wavelengths and other detector properties) and by channel saturation of the microchannel plate. Both affect the signal-to-noise ratio of the power spectrum and bispectrum.

Horch, E.↗