Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “pump systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

25 Years Of Environmental Remediation In The General Separations Area Of The Savannah River Site: Lessons Learned About What Worked And What Did Not Work In Soil And Groundwater Cleanup

The Savannah River Site (SRS) is owned and administered by the US Department of Energy (DOE). SRS covers an area of approximately 900 square kilometers. The General Separation Area (GSA) is located roughly in the center of the SRS and includes: radioactive material chemical separations facilities, radioactive waste tank farms, a variety of radioactive seepage basins, and the radioactive waste burial grounds. Radioactive wastes were disposed in the GSA from the mid-1950s through the mid-1990s. Radioactive operations at the F Canyon began in 1954; radioactive operations at H Canyon began in 1955. Waste water disposition to the F and H Seepage Basins began soon after operations started in the canyons. The Old Radioactive Waste Burial Ground (ORWBG) began operations in 1952 to manage solid waste that could be radioactive from all the site operations, and ceased receiving waste in 1972. The Mixed Waste Management Facility (MWMF) and Low Level Radioactive Waste Disposal Facility (LLRWDF) received radioactive solid waste from 1969 until 1995. Environmental legislation enacted in the 1970s, 1980s, and 1990s led to changes in waste management and environmental cleanup practices at SRS. The US Congress passed the Clean Air Act in 1970, and the Clean Water Act in 1972; the Resource Conservation and Recovery Act (RCRA) was enacted in 1976; the Comprehensive Environmental Response Compensation, and Liability Act (CERCLA) was enacted by Congress in 1980; the Federal Facilities Compliance Act (FFCA) was signed into law in 1992. Environmental remediation at the SRS essentially began with a 1987 Settlement Agreement between the SRS and the State of South Carolina (under the South Carolina Department of Health and Environmental Control - SCDHEC), which recognized linkage between many SRS waste management facilities and RCRA. The SRS manages several of the larger groundwater remedial activities under RCRA for facilities recognized early on as environmental problems. All subsequent environmental remediation projects tend to be managed under tri-party agreement (DOE, Environmental Protection Agency, and SCDHEC) through the Federal Facilities Agreement. During 25 years of environmental remediation SRS has stabilized and capped seepage basins, and consolidated and capped waste units and burial grounds in the GSA. Groundwater activities include: pump and treat systems in the groundwater, installation of deep subsurface barrier systems to manage groundwater flow, in situ chemical treatments in the groundwater, and captured contaminated groundwater discharges at the surface for management in a forest irrigation system. Over the last 25 years concentrations of contaminants in the aquifers beneath the GSA and in surface water streams in the GSA have dropped significantly. Closure of 65 waste sites and 4 RCRA facilities has been successfully accomplished. Wastes have been successfully isolated in place beneath a variety of caps and cover systems. Environmental clean-up has progressed to the stage where most of the work involves monitoring, optimization, and maintenance of existing remedial systems. Many lessons have been learned in the process. Geotextile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive, enhanced natural processes to address groundwater contamination are much more cost effective than pump and treat systems. SRS operated two very large pump and treat systems at the F and H Seepage Basins to attempt to limit the release of tritium to Fourmile Branch, a tributary of the Savannah River. The systems were designed to extract contaminated acidic groundwater, remove all contamination except tritium (not possible to remove the tritium from the water), and inject the tritiated groundwater up-gradient of the source area and the plume. The concept was to increase the travel time of the injected water for radioactive decay of the tritium. The two systems were found to be non-effective and potentially mobilizing more contamination. SRS invested approximately $50 million in construction and approximately $100 million in 6 years of operation. The H Seepage Basin pump and treat system was replaced by a series of subsurface barriers that alters the groundwater velocity; the F Seepage Basin pump and treat system was replaced by subsurface barriers forming a funnel and gate augmented by chemical treatment within the gates. These replacement systems are mostly passive and cost approximately $13 million to construct, and have reduced the tritium flux to Fourmile Branch, in these plumes, by over 70%. SRS manages non-acidic tritiated groundwater releases to Fourmile Branch from the southwest plume of the MWMF with a forest irrigation system. Tritiated water is captured with a sheetpile dam below the springs that caused releases to Fourmile Branch. Water from the irrigation pond is pumped to a filter plant prior to irrigation of approximately 26 hectares of mixed forest and developing pine plantation. SRS has almost achieved a 70% reduction in tritium flux to the Branch from this plume. The system cost approximately $5 million to construct with operation cost of approximately $500K per year. In conclusion, many lessons have been learned in 25 years of relatively aggressive remedial activities in the GSA. Geotextile covers outperform low permeability clay caps, especially with respect to the amount of repairs required to upkeep the drainage layers as the caps age. Passive, enhanced natural processes to address groundwater contamination are much more cost effective than pump and treat systems. In water management situations with non-accumulative contaminants (tritium, VOCs, etc.) irrigation in a forest setting can be very effective.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solar technology in the Federal Republic of Germany

A series of papers dealing with the status of solar research and development in the Federal Republic of Germany are presented at a conference in Greece with the object of promoting international cooperation in solar energy utilization. The reports focus on solar collector designs, solar systems, heat pumps, solar homes, solar cooling and refrigeration, desalination and electric power generation. Numerous examples of systems produced by German manufacturers are illustrated and described, and performance data are presented.

Source record↗

Design of a Mechanical NaK Pump for Fission Space Power Systems

Alkali liquid metal cooled fission reactor concepts are under development for mid-range spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid. Traditionally, linear induction pumps have been used to provide the required flow and head conditions for liquid metal systems but can be limited in performance. This paper details the design, build, and check-out test of a mechanical NaK pump. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.

Mireles, Omar R.↗

Technical and Economic Assessment of Solar Photovoltaic for Groundwater Extraction on the Hanford Site

The overall goal of environmental remediation is to protect human health and the environment. Implementing renewable energy sources such as solar photovoltaic (PV) in groundwater extraction and pump-and-treat (P&T) systems may help minimize the environmental footprint of remediation efforts. The first step in considering solar PV for powering Hanford groundwater extraction is assessing the technical and economic feasibility and identifying potential target locations where implementation would be most successful. Accordingly, a techno-economic assessment of solar PV for Hanford groundwater extraction was completed in FY15. Multiple solar PV alternatives ranging in size from 1.2 to 22.4 kWp DC were evaluated and compared against traditional grid-powered systems. Results indicate that the degree to which solar PV alternatives are feasible is primarily a function of the distance of avoided power cable costs and the inclusion of an energy storage component. Standalone solar PV systems provide an energy source at the well and avoid the costs and logistics associated with running long lengths of expensive power cable to the well-head. When solar PV systems include a battery storage component, groundwater can be pumped continuously day and night in a year-round schedule. However, due to the high cost premium of the energy storage component, a fully solar-powered solution could not provide an economic direct replacement for line-powered pumping systems. As a result, the most ideal target locations for successful implementation of solar PV on the Hanford Site are remote or distant extraction wells where the primary remedial objective is contaminant mass removal (as opposed to hydraulic containment) and three-season (March through October) intermittent pumping is acceptable (e.g. remediation of hexavalent chromium in 200-UP-1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Bosch Process System Models for In-Situ Oxygen and Carbon Production

In-Situ Resource Utilization (ISRU) technology is a vital component to NASA’s mission of a sustainable presence on the Moon and Mars. Local resources can be leveraged to reduce resupply frequency and mass. Elements of the Bosch process, combined with the carbothermal reduction process, can produce oxygen on the lunar surface with minimal consumables. The Bosch process can also produce oxygen on the Martian surface by using the CO 2 -rich environment. Between both systems, adsorption pump, solar thermal energy, carbon formation reactor, and water recovery subsystems are modeled and integrated to create a functional model in MATLAB software. The model is used to simulate performance of the system and reduce mass, power, and volume requirements. This integrated system model provides a tool to scale ISRU technologies for oxygen and carbon production. The MATLAB model is created by developing a system of independent subsystem models that are solved for their quasi-steady state values which can be integrated with respect to time to determine the change in current states. A flexible time stepping method is used to ensure a high level of accuracy during periods of rapid change while still making use of a simple explicit integration method. The flexible time step is calculated for each independent subsystem and the minimum value from those is used as the overall time step. A flexible time step is calculated by dividing a resolution value, or the maximum change per time step, by the variables current rate of change. The maximum value from all points in space is used for subsystem models that contain multiple values. The process is done for every variable that is being monitored in each subsystem and the global minimum is used as that iteration’s timestep. Several assumptions used in the MATLAB model for fluid flow dynamics, such as 1-D gas flow through the sorption pump, are supported by modeling in Ansys Fluent software. The Lunar oxygen production system is outlined in Fig. 1. The carbothermal reduction subsystem uses solar energy to heat a mixture of lunar regolith and carbon powder to produce carbon monoxide. To begin, the carbon monoxide feeds to the modified Bosch subsystem along with hydrogen gas. The reactants then enter the carbon formation reactor where water and carbon powder are produced. Solar thermal energy is used to add energy to the reactor, but waste heat from the carbothermal process is another potential heat source. The water is collected and electrolyzed to produce hydrogen which reenters the Bosch subsystem, and the oxygen is stored for downstream use. The carbon powder is collected and feeds back into the carbothermal subsystem. The Martian oxygen production system uses the full Bosch process and is outlined in Fig 2. A CO 2 adsorption pump thermally cycles to scrub and pressurize CO 2 from the environment. Along with an initial supply of hydrogen, the reactants enter the Reverse Water Gas Shift Reactor (RWGSR) which produces carbon monoxide and water. Carbon monoxide and unreacted hydrogen enter the carbon formation reactor to produce water and carbon powder. The water is collected from both reactors and electrolyzed to reintroduce hydrogen and store oxygen for propellant production or life support. Carbon is removed from the carbon formation reactor and stored. The adsorption pump utilizes rapid cycle temperature swings within a stack of zeolite coated surfaces. The subsystem model solves 1-D quasi-steady conservation laws of the quasi-steady form, shown in Eq. 1, for the gas stream and heat exchange liquid to predict performance parameters such as breakthrough capacity and optimum cycle time. The source term S is used to capture interactions between the fluid flows and the sorbent. A quasi-steady-state scheme is used where no time derivatives appear in the governing equations, except for those in the source terms. This results in an autonomous system, where ∂F/∂x = ƒ(F). The fluxes F are provided at the inlet, and an explicit method is used to solve for the spatial distribution of F. The heat and mass flows to the sorbent are then extracted from the source terms. These flows are numerically integrated to produce a 1-D solution for the system’s state as a function of both time and space. The body of the adsorption pump is separated into two semi-independent models: the heat exchanger fluid flow and gas flow through the zeolite coated surfaces. Both models are solved using the above-described method to find a 1-D solution as a function of space and interact only once a timestep is taken. The interaction point is the sorbent through which all heat transfer between the two models must occur. Sorbent mass adsorption is calculated using the Lagergren model, shown in Eq. 2, where the transfer coefficient, λ D , is found by solving a system of nondimensionalized equations derived by using the heat and mass transfer analogy for transport phenomena. Using Grade 544 Type 13X zeolite as the sorbent material, the equilibrium concentration, θ eq , is calculated using the k-site Langmuir isotherm and fit parameters. Additionally, the enthalpy of adsorption used in the model is computed by interpolation of available data [1]. The subsystem model was validated using the Rapid Cycle Temperature Swing Adsorption (RC-TSA) pump. The solar thermal energy subsystem focuses on a solar concentrator concept with a heat exchanger to heat the reactants before entering the carbon formation reactor. The subsystem model assumes a fixed solar flux and reflector efficiency to calculate the reactant temperature given the incoming temperature, pressure, and exchanger geometry. The receiver is a custom manufactured series of copper blocks with serpentine channels to increase its surface area and the residence time of the reactants to heat up to 550 °C. The subsystem model was validated using a heat exchanger developed at NASA Glenn Research Center (GRC). The solar thermal energy subsystem focuses on a solar concentrator concept with a heat exchanger to heat the reactants before entering the carbon formation reactor. The subsystem model assumes a fixed solar flux and reflector efficiency to calculate the reactant temperature given the incoming temperature, pressure, and exchanger geometry. The receiver is a custom manufactured series of copper blocks with serpentine channels to increase its surface area and the residence time of the reactants to heat up to 550 °C. The subsystem model was validated using a heat exchanger developed at NASA Glenn Research Center (GRC).

In situ Resource Utilization↗

A review of control methodologies for vapor compression and absorption heat pumps; Examen des méthodes de régulation des pompes à chaleur à compression et à absorption de vapeur

Here this paper presents an overview of control systems for heat pumps, and more specifically, a critical review of control methodologies for thermally activated absorption heat pumps. The objectives of a control system are identified and discussed, including optimal system operation, ability for continuous turndown, and fast response to changes in the operating conditions. Key details of different aspects of research and development such as steady-state and transient thermodynamic models, control algorithm development, and implementation are presented. Advanced multivariable feedback controls are able to perform better than individual feedback control loops and conventional on/off controls. The knowledge of the transient response of heat pump systems through models or experimental data is crucial for advanced control system design and implementation. Recently, data-based methods have also gained interest, but they are difficult to generalize. A general outlook with limitations and the potential of different approaches, and recommendations for future work are provided.

42 ENGINEERING↗

HOW THE LEED VENTILATION CREDIT IMPACTS ENERGY CONSUMPTION OF GSHP SYSTEMS A CASE STUDY FOR PRIMARY SCHOOLS

This paper presents a study on the impacts of increased outdoor air (OA) ventilation on the performance of ground-source heat pump (GSHP) systems that heat and cool typical primary schools. Four locations Phoenix, Miami, Seattle, and Chicago are selected in this study to represent different climate zones in the United States. eQUEST, an integrated building and HVAC system energy analysis program, is used to simulate a typical primary school and the GSHP system at the four locations with minimum and 30% more than minimum OA ventilation. The simulation results show that, without an energy recovery ventilator, the 30% more OA ventilation results in an 8.0 13.3% increase in total GSHP system energy consumption at the four locations. The peak heating and cooling loads increase by 20.2 30% and 14.9 18.4%, respectively, at the four locations. The load imbalance of the ground heat exchanger is increased in hot climates but reduced in mild and cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

Tuning of the spin pumping in yttrium iron garnet/Au bilayer system by fast thermal treatment

In this Letter, we investigated the influence of the fast thermal treatment on the spin pumping in ferromagnetic insulator yttrium iron garnet (YIG)/normal metal Au bilayer system. The YIG/Au bilayer thin films were treated by fast annealing process with different temperatures from 0 to 800 °C. The spin pumping was studied using ferromagnetic resonance. The surface evolution was investigated using a high resolution scanning microscopy and an atomic force microscopy. A strong thermal related spin pumping in YIG/Au bilayer system has been revealed. It was found that the spin pumping process can be enhanced by using fast thermal treatment due to the thermal modifications of the Au surface. The effective spin-mixing conductance of the fast thermal treated YIG/Au bilayer has been obtained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Closed Loop Pumped Storage Hydropower Resource Assessment of the United States

The data includes a geospatial and spreadsheet representation of a resource analysis for closed loop pumped storage systems across the Continental United States, Alaska, Hawaii, and Puerto Rico. The data includes energy storage potential, water volume, distance from source to storage, hydraulic head, dollars per kilowatt of storage, and transmission spurline cost for each pumped storage hydropower (PHS) reservoir. Each reservoir represented in this dataset is represented on potential 10 hour storage duration PSH system comprised of two reservoirs. Units of measure are laid out in the dataset. Pumped storage hydropower (PSH) represents the bulk of the United States' current energy storage capacity: 23 gigawatts (GW) of the 24 GW national total (Denholm et al. 2021). This capacity was largely built between 1960 and 1990. PSH is a mature and proven method of energy storage with competitive round-trip efficiency and long life spans. These qualities make PSH a very attractive potential solution to energy storage needs, particularly for longer-duration storage (8 hours or more); such storage will be crucial to bridge gaps in electricity production as variable wind and solar production continue to comprise an ever-larger portion of the United States' energy portfolio. This study seeks to better understand the technical potential for PSH development in the United States by developing a national-scale resource assessment for closed-loop PSH. For more information, please refer to the Closed Loop Pumped Storage Hydropower Resource Assessment for the United States linked in the resources.

Array↗

Development of a Residential Ground-Source Integrated Heat Pump

A residential-size ground-source integrated heat pump (GSIHP) system has been developed and is currently being field tested. The system is a nominal 2-ton (7 kW) cooling capacity, variable-speed unit, which is multi-functional, e.g. space cooling, space heating, dedicated water heating, and simultaneous space cooling and water heating. High-efficiency brushless permanent-magnet (BPM) motors are used for the compressor, indoor blower, and pumps to obtain the highest component performance and system control flexibility. Laboratory test data were used to calibrate a vapor-compression simulation model (HPDM) for each of the four primary modes of operation. The model was used to optimize the internal control options and to simulate the selected internal control strategies, such as controlling to a constant air supply temperature in the space heating mode and a fixed water temperature rise in water heating modes. Equipment performance maps were generated for each operation mode as functions of all independent variables for use in TRNSYS annual energy simulations. These were performed for the GSIHP installed in a well-insulated 2600 ft2(242 m2) house and connected to a vertical ground loop heat exchanger(GLHE). We selected a 13 SEER (3.8 CSPF )/7.7 HSPF (2.3 HSPF, W/W) ASHP unit with 0.90 Energy Factor (EF) resistance water heater as the baseline for energy savings comparisons. The annual energy simulations were conducted over five US climate zones. In addition, appropriate ground loop sizes were determined for each location to meet 10-year minimum and maximum design entering water temperatures (EWTs) to the equipment. The prototype GSIHP system was predicted to use 52 to 59% less energy than the baseline system while meeting total annual space conditioning and water heating loads.

Energy Efficiency↗

Two low-cost, modular sub-λ test cryostats

Two general-purpose liquid helium (LHe) test cryostats have been developed in support of a major upgrade to the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The cryostats are capable of sustained operation below 1.8 K and currently support tests of prototype superconducting rf (srf) cavities for the APS Upgrade’s Short Pulse X-ray (SPX) initiative. To save cost, two existing test vessels were reconditioned: one “bucket dewar” supporting bare cavity tests and one shielded vacuum vessel with an integral LHe reservoir for jacketed/dressed cavity tests. A new feedbox containing a heat exchanger and associated valves was also designed and fabricated to support either cryostat. The resulting modular design permits tests on a wide variety of srf cavities in various states of completion, minimizing cost and maximizing use of the hardware. Together with a dedicated vacuum pump, control system, and helium supply via storage dewar or cryoplant, these cryostats are vital to the srf cavity development effort within the APS Upgrade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mutual Influence of Capillary Pumps in Heat-Pipe Systems with Different Evaporator Loads

Thermal management systems that are not hermetically sealed have been developed for use in spacecraft; in such systems, scientific equipment and instruments operate in open space. Accordingly, new methods of thermal regulation have been developed: axial and loop heat pipes; and honeycomb thermal panels with embedded axial heat pipes. Heat transfer in heating systems with heat pipes is based on evaporation and condensation in a two-phase loop. The working fluid moves under the action mainly of capillary forces that appear in capillary channels or honeycomb structures for axial heat pipes and in the porous heated medium (capillary pump) of the loop heat pipes.

42 ENGINEERING↗

Experimental evaluation and thermodynamic system modeling of thermoelectric heat pump clothes dryer

Electric clothes dryers consume about 6% of US residential electricity consumption. Using a solid-state technology without refrigerant, thermoelectric (TE) heat pump dryers have the potential to be more efficient than units based on electric resistance and less expensive than units based on vapor compression. This study presents a steady state TE dryer model, and validates the model against results from an experimental prototype. The system model is composed of a TE heat pump element model coupled with a psychrometric dryer sub-model. Experimental results had energy factors (EFs) of up to 2.95 kg of dry cloth per kWh (6.51 lb c /kWh), with a dry time of 159 min. A faster dry time of 96 min was also achieved at an EF of 2.54 kg c /kWh (5.60 lb c /kWh). The model was able to replicate the experimental results within 5% of EF and 5% of dry time values. Finally, the results are used to identify important parameters that affect dryer performance, such as relative humidity of air leaving the drum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-Cost Control System Built Upon Consumer-Based Electronics For Supervisory Control Of A Gas-Operated Heat Pump

A preliminary evaluation of the performance of a consumer-based control system was conducted by the Oak Ridge National Laboratory (ORNL) and Southwest Gas as part of a cooperative research and development agreement (CRADA) authorized by the Department of Energy (DOE) (Mahderekal et al. (2013). The goal of the research was to evaluate the low-cost approach as a solution for implementing a supervisory control system for a residential gas-operated heat pump. The design incorporated two consumer-based micro-controllers; the Arduino Mega-2650 and the BeagleBone (white). Ten five-ton heat pump systems were designed, fabricated, and operationally tested in the Las Vega NV region. A robust data set was produced that allowed detailed assessment of the reliability and the operational perfromance of the newly developed control system. Experiences gained from the test provided important points of improvement for subsequent evolution of the heat pump technology.

Wetherington Jr, G↗

Electromagnetic Pumps for Conductive-Propellant Feed Systems

There has been a recent, renewed interest in high-power electric thrusters for application in nuclear-electric propulsion systems. Two of the most promising thrusters utilize liquid metal propellants: the lithium-fed magnetoplasmadynamic thruster and the bismuth-fed Hall thruster. An important element of part of the maturation of these thrusters will be the development of compact, reliable conductive-propellant feed system components. In the present paper we provide design considerations and experimental calibration data for electromagnetic (EM) pumps. The role of an electromagnetic pump in a liquid metal feed system is to establish a pressure gradient between the propellant reservoir and the thruster - to establish the requisite mass flow rate. While EM pumps have previously been used to a limited extent in nuclear reactor cooling loops, they have never been implemented in electric propulsion (EP) systems. The potential benefit of using EM pumps for EP are reliability (no moving parts) and the ability to precisely meter the propellant flow rate. We have constructed and tested EM pumps that use gallium, lithium, and bismuth propellants. Design details, test results (pressure developed versus current), and material compatibility issues are reported. It is concluded that EM pumps are a viable technology for application in both laboratory and flight EP conductive-propellant feed systems.

Markusic, T. E.↗