Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power system security”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Impact of Inverter Based Resource Negative Sequence Current Injection on Transmission System Protection

This report documents the results of analysis performed to investigate the impact of inverter-based resource (IBR) response to unbalanced faults on transmission system protective relay dependability and security. Electromagnetic transient (EMT) simulations were performed to simulate IBR response to these faults using existing manufacturer-developed EMT models for four separate IBRs. The study team was composed of IBR manufacturers, relay manufacturers, transmission providers, reliability coordinators and industry consultants with experience in EMT simulation and system protection. The results indicate that under certain conditions, IBR response can result in protective relay misoperations if current protection practices, which were developed based on conventional power sources, are not adapted to the characteristics of IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Microstructured BaTiO 3 -Embedded PVDF–HFP/PEO Film for Enhanced Triboelectric Interface in Self-Sufficient Energy Generation and Sensing

The global reliance on fossil fuels and natural gas has largely dominated the energy production field, but due to finite resource depletion and escalating greenhouse gas emissions, the immediate exploration of sustainable energy alternatives to mitigate climate change and ensure resource security has been a major concern. There has been extensive research into other more renewable methods of energy production, such as wind and hydropower. Of these current energy generation types, there are many areas of untapped potential from the mechanical movements generated ambiently not only in the large scale of power generation but also on a smaller scale. The piezoelectric and triboelectric effects are phenomena where these ambient mechanical movements can generate electrical energy. Developing a hybrid system that leverages both mechanical stress and surface charges presents an ideal opportunity to exploit these untapped energy sources. Producing a hybrid PVDF–HFP/PEO film with perovskite BaTiO 3 (BTO) enables ambient power harvesting from both mechanical movement and surface charge. The optimized cell produced a potential of up to 15 V and a current of 200 nA with a 68 kΩ resistor, a substantial increase from a base system with an average of 2.1 V and 40 nA. These hybrid TENGs offer significant potential for energy harvesting in small-scale applications, such as health monitoring devices and indicators in electric circuits.

Ybarra, Rigobert [University of Texas Rio Grande V↗

Foreign Entity of Concern Requirements in the One Big Beautiful Bill Act

The One Big Beautiful Bill Act (OBBB), enacted July 4, 2025, makes billions of dollars in federal energy tax credits conditional on supply chain independence from China and other foreign entities of concern. The OBBB simultaneously creates powerful economic incentives to reshore energy supply chains to the United States and allied nations. Through such incentives, the OBBB elevates digital assurance and supply chain verification from voluntary best practices into critical capabilities for demonstrating tax credit eligibility. The OBBB uses tax credit eligibility requirements to simultaneously address national security concerns regarding foreign supply chain dependencies and incentivize domestic energy manufacturing. This brief details how organizations should operationalize these requirements through baseline compliance audits, interim documentation systems, supply chain diversification strategies, and long-term institutional integration of digital assurance capabilities that turn compliance burdens into competitive advantages

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Development of Control System Functional Capabilities within the IES Plug-and-Play Simulation Environment

The concept of an Integrated Energy System (IES) is meant to combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES. A new RAVEN (Risk Analysis Virtual ENvironment) plugin for grid and capacity optimization (HERON) has been developed for optimizing the production variables of the IES given the demand profile. Currently, only the limits that affect the production variables and their corresponding time rates of change are considered (explicit constraints). However, other variables are additionally subject to constraints, but the associated limits are not accounted for (implicit constraints). In particular, for the power dispatch problem, the optimization algorithm takes into account the limits on the electrical power output and the corresponding hourly power variations but does not consider other constraints on process variables whose response effects the service life of the IES. This report describes a scheme that allows accounting for implicit constraints without increasing the size of the optimization problem. The Reference Governor (RG) algorithm is traditionally used for enforcing state and control constraints by modifying the set-point trajectories supplied to the feedback regulators. In our application, the RG is coupled within an iterative loop with the HERON-power dispatcher to generate optimal trajectories that ensure the operational constraints are met. A data-driven procedure to derive a representation of the dynamics of the controlled system was developed. First, the variables that represented the state of the system are selected (PCA-based approach), and then state-space representation matrices are derived from the collected measurements (DMDc algorithm). A preliminary version of the developed workflow based on Linear Time Invariant matrices was assessed by adopting a two-unit test case. More sophisticated versions of this workflow foreseeing the on-line derivation of system matrices will be deployed in FY 2021. Finally, a “plug-and-play” library of controllers and state observers was developed in Dymola. Some aspects of the current configuration of the IES unit components, e.g., the encapsulation of the control schemes into dedicated blocks, are consistent with the “plug-and-play” philosophy. Other features, e.g., the system buses collecting the input and the output variables, are not. For this reason, once listed and described the limits of the current configuration, necessary modifications to the plant model interface are presented. As a test-case, the interfaces of the SES model in the RAVEN-based HYBRID framework were reworked accordingly, and two different control schemes were applied to the same plant model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

FY25 Electric Grid Security Annual Report

Sandia’s Electric Grid Security program advances a national vision of energy dominance and accessibility, while applying our national security -emphasis on ensuring of a secure, resilient, and affordable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY25 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Key accomplishments in this report that support our strategy span our technical program areas and include: • New open-source analytical tools for systems -level planning and optimization, including significant advances to the QuESt analytical environment; • Further advancement of artificial intelligence and machine learning to enhanced grid operations and planning as we rise to the challenge of new large loads; • Development of solid-state power conversion technologies and a new medium-voltage research lab; • New technologies to assess wildfire vulnerabilities and mitigate potential impacts; • Advanced applications of new cybersecurity technologies with industry partners; • Contributions to understanding the impacts of electromagnetic pulses and geomagnetic disturbances on grid components; and • Digital twin development for hybrid microgrids with multiple generators, storage, and loads. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by several offices within the U.S. Department of Energy (USDOE), including the Office of Electricity (OE); Cybersecurity, Energy Security, and Emergency Response (CESER); former offices such as the Office of Energy Efficiency and Renewable Energy (EERE), the Grid Deployment Office (GDO), the Office of Clean Energy Demonstrations (OCED), and other key programs at USDOE. As we continue to state in these annual reports, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint scheduling of energy, fast and primary frequency response reserves in integrated transmission–distribution networks

Inverter-based distributed energy resources (DERs) connected to distribution networks (DNs) can provide fast frequency support, but their reserve deliverability depends on feeder constraints and differs from synchronous primary frequency response (PFR). Existing transmission–distribution coordination studies usually treat reserve generically or neglect feeder-level feasibility, while frequency-security scheduling studies rarely represent distribution feeders explicitly. This paper develops a bi-level day-ahead scheduling framework for integrated transmission–distribution networks that jointly clears energy, transmission-side PFR, and distribution-side fast frequency response (FFR) under exogenous hourly inertia and largest-loss inputs from an external unit commitment (UC) schedule. The transmission problem is modeled with DC-optimal power flow (OPF) and closed-form second-order cone (SOC) frequency-security constraints, whereas each DN is represented by a reserve-aware branch-flow AC-OPF so that scheduled fast reserves remain deliverable during activation. The bi-level problem is reformulated through Karush–Kuhn–Tucker (KKT) conditions into a mixed-integer SOC program, and a penalty term is used to tighten the distribution-network relaxation. In the reduced test system, lower exogenous inertia increased the required primary response from 179.64 MW to 191.08 MW, distribution-side fast response reduced total frequency-response procurement by up to 4.9%, and neglecting distribution constraints overstated the combined distribution-side energy and reserve award by up to 18%. In the expanded study, the largest case was solved in 2.02 s with a 0.00% optimality gap. Time-domain simulations kept the frequency nadir above 59.0 Hz in all tested hours. These results demonstrate the value of fast-response modeling and distribution-feasible reserve delivery in coordinated market clearing.

Noh, Seung-Gil↗

MOD-Amp System Design Spring: Spring 2026 – Georgetown University, SYSM–5620

High-energy lasers (HELs) play an important role in both national defense and scientific research. In defense applications, HELs are used for target detection, tracking, and engagement. In research environments, they support studies of extreme physical conditions relevant to fusion energy and plasma science. These systems depend on the amplification of light through stimulated emission of radiation, allowing optical energy to be increased to the levels required for operation. This amplification occurs when light passes through an energized gain medium that receives energy from an external optical or electrical source. To achieve the desired output, laser systems often use multiple amplification stages, including high-gain preamplifiers and lower-gain power or booster amplifiers. At Lawrence Livermore National Laboratory (LLNL) and other national laboratories, many large-aperture laser amplifier systems are aging and rely on system-specific hardware, obsolete technologies, and incomplete documentation. These legacy systems create challenges for maintenance, supportability, and long-term operation. Their lack of standardization also increases the difficulty of sustaining reliable performance over time. As this infrastructure continues to age, the likelihood of unplanned downtime grows, which can negatively affect both national security missions and scientific research programs that depend on dependable HEL capabilities. The purpose of this document is to demonstrate the application of systems engineering fundamentals and design thinking through the development of a laser amplifier case study. The proposed system concept is intended as an academic exercise and not as a finalized engineering design. As a result, the development presented in this document is incomplete and may contain technical assumptions or errors that would require further investigation before any real-world implementation.

42 ENGINEERING↗

Methods and systems for detection of man-in-the-middle attacks for SCADA communication networks and applications of same

A system for detecting MITM for SCADA communication networks includes secure substation-substation communication links for providing secure and reliable paths to exchange OT data between substations for OT data consistency check; a SIB in each substation for sampling CT and PT measurements to calculate voltage magnitude and phase angle thereof; a S&C server in each substation coupled to the SIB for receiving the voltage magnitude and phase angle from the SIB and obtaining a packet carrying active power flow in transmission lines between two substations and a time stamp; an IDS server placed in a SCADA center for collecting the packet of each substation sent by the S&C server; analyzing the received packet from every adjacent substation; inspecting the payload of the received packet; and triggering an intrusion alarm to a SCADA operator when the power flow is not the same as the payload of the packets.

McCann, Roy A.↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Security constrained optimal power shutoff for wildfire risk mitigation

Abstract Electric grid faults are increasingly the source of ignition for major wildfires. To reduce the likelihood of such ignitions in high risk situations, utilities use preemptive de‐energization of power lines, commonly referred to as Public Safety Power Shutoffs (PSPS). Besides raising challenging trade‐offs between power outages and wildfire safety, PSPS removes redundancy from the network at a time when component faults are likely to happen. This may leave the network particularly vulnerable to unexpected line faults that may occur while the PSPS is in place. Previous works have not explicitly considered the impacts of these outages. To address this gap, the Security Constrained Optimal Power Shutoff problem is proposed which uses post‐contingency security constraints to model the impact of unexpected line faults when planning a PSPS. This model enables, for the first time, the exploration of a wide range of trade‐offs between both wildfire risk and pre‐ and post‐contingency load shedding when designing PSPS plans, providing useful insights for utilities and policy makers considering different approaches to PSPS. The efficacy of the model is demonstrated using the EPRI 39‐bus system as a case study. The results highlight the potential risks of not considering security constraints when planning PSPS and show that incorporating security constraints into the PSPS design process improves the resilience of current PSPS plans.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Idaho National Laboratory Energy Cybersecurity Programs Update

This brief presentation provides a status update on three Idaho National Laboratory energy cybersecurity programs of particular interest to NERC Reliability and Security Technical Committee annual in-person Security Groups summit. Public information on the following three programs is included: Cybersecurity for Operational Technology Environments (CyOTE™) program Cyber-Informed Engineering (CIE) Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, and associated high-level information on the Energy Software Bill of Materials POC, Executive Order 14017, and the Energy Cyber Sense Act

24 POWER TRANSMISSION AND DISTRIBUTION↗

The role of current and emerging technologies in meeting Japan’s mid- to long-term carbon reduction goals

Using Japan as a proxy for a developed nation, we investigated the role of existing and nascent technologies in curbing carbon emissions. We simulated possible pathways to meeting 2030 and 2050 emission targets within the Japanese electricity supply sector using a single-region model in The Integrated MARKAL-EFOM System (TIMES). Critically, our simulations incorporate novel technologies like hydrogen electrolysers, carbon capture, photochemical water splitting, and emerging photovoltaic cells, assess long-term impacts up to the year 2100, and include life-cycle emissions and learning curves for parameters such as investment cost, efficiency, and emission coefficients. Results indicate that a hybrid approach, using nuclear power and hydrogen from renewable energy-based electrolysis, is cost-effective and provides long-term emission reduction along with energy security. Finally, nuclear, wind, solar, and hydrogen from renewables emerge as key emission reduction technologies, while natural gas with carbon capture plays a minor role in achieving emission reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Surrogate-Based Asynchronous Decomposition Technique for Realistic Security-Constrained Optimal Power Flow Problems

Here we present a decomposition approach for obtaining good feasible solutions for the security-constrained, alternating-current, optimal power flow (SC-AC-OPF) problem at an industrial scale and under real-world time and computational limits. The approach was designed while preparing and participating in ARPA-E’s Grid Optimization Competition (GOC) Challenge 1. The challenge focused on a near-real-time version of the SC-AC-OPF problem, where a base operating point is optimized, taking into account possible single-element contingencies, after which the system adapts its operating point following the response of automatic frequency droop controllers and voltage regulators. Our solution approach for this problem relies on state-of-the-art nonlinear programming algorithms, and it employs nonconvex relaxations for complementarity constraints, a specialized two-stage decomposition technique with sparse approximations of recourse terms and contingency ranking and prescreening. The paper describes and justifies our approach and outlines the features of its implementation, including functions and derivatives evaluation, warm-starting strategies, and asynchronous parallelism. We discuss the results of the independent benchmark of our approach by ARPA-E’s GOC team in Challenge 1, where it was found to consistently produce high-quality solutions across a wide range of network sizes and difficulty, and conclude by outlining future extensions of the approach.

97 MATHEMATICS AND COMPUTING↗

2022 Small Turbine Certification Awardee: NPS Solutions

Inverters convert the direct current power generated by wind turbines into the alternating current needed to serve local loads and feed onto the electricity grid. Although distributed wind systems typically supply electricity for homes and businesses near the turbines, these systems can also provide clean power to strengthen grid resilience. Certification to UL 1741 SA ensures that inverters will enable distributed wind turbines to provide grid support services and stay online when the grid experiences stability issues. Small companies often find the electrical listing process too complex and expensive to undertake on their own, so few distributed wind turbine inverters are certified to this standard. A U.S. Department of Energy (DOE) Competitiveness Improvement Project (CIP) award is helping NPS Solutions (NPS) secure this critical certification for the inverter in its 100-kilowatt NPS 100C wind turbine, which is optimized for on-site generation at farms, businesses, schools, hospitals, and remote locations.

CIP↗

Responsible Adoption of Artificial Intelligence (AI) in Electric Grid Operations

The future of the grid will be powered by AI—or undermined by it. Artificial intelligence is rapidly reshaping grid operations, improving fault detection, forecasting accuracy, and real-time optimization. As AI systems move closer to operational decision loops, however, they introduce new consequence pathways: expanded attack surfaces, model integrity risks, regulatory exposure, and human-automation challenges. This talk presents a consequence-driven framework for deploying AI responsibly in the electric grid. Attendees will gain practical strategies to strengthen resilience, boost reliability, and deploy AI securely — ensuring the grid of the future is not only smarter but safer.

25 - ENERGY STORAGE↗

Real-Time Testbed for Smart Grid Recloser Controller

The growing need for a low voltage recloser has become apparent due to the rise in requirements for a smart grid. This includes more detailed management of power flow forward (towards load) and backward (towards generation), source synchronization in real time, more indepth fault responses, and the use of green energy. The SEL-651R-2 relay is a device that can manage these needs, especially in fault response and synchronization, and is commonly used in systems called microgrids. Microgrids are distribution level systems that are able to operate separated from the main grid, are typically installed much closer to the load(s), and are fed by distributed energy resources (DERs), such as wind, solar or diesel generators. The SEL-651R-2 is normally used in the field with presets operative settings, but the Western Michigan University (WMU) Center for Interdisciplinary Research on Secure, Efficient and Sustainable Energy Technology (WMU InterEnergy Center) wished to test this device in its range of capabilities for microgrid application. A Hardware-In-the-Loop (HIL) testbed was implemented and used through the Real Time Digital Simulator (RTDS) using the RSCAD software to test the SEL-651R-2's use cases and functions. The testbed includes a microgrid with interconnection to a larger main grid, and the relay is meant to control the recloser at the point of common coupling (PCC) between the main grid and microgrid. The testbed shows how basic protections, reclosing, and synchronization checks function when handling faults that affect both the microgrid and the main grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

US Department of Energy, Office of Science High Performance Computing Facility Operational Assessment 2019 Oak Ridge Leadership Computing Facility

Oak Ridge National Laboratory's (ORNL's) Leadership Computing Facility (OLCF) continues to surpass its operational target goals: supporting users; delivering fast, reliable computational ecosystems; creating innovative solutions for high performance computing (HPC) needs; and managing risks, safety, and security associated with operating some of the most powerful computers in the world. The results can be seen in the cutting-edge science conducted by users and the praise from the research community. Calendar year (CY) 2019 was a big year as OLCF staff ran five world-class resources (the leadershipclass computers Titan and Summit, the large analysis cluster called Eos, and the massive parallel filesystems called Atlas and Alpine)) and also began power and cooling upgrades for a 2021 exascale system called Frontier. While continuing exceptional operation of Titan, Eos, and Rhea, the OLCF released the Summit supercomputer for production on January 1, 2019. Summit debuted as the most capable and efficient system in its class and has been recognized as the most powerful system in the world for its performance on both the high performance linpack (HPL) and conjugate gradient (HPCG) benchmark applications since June 2018 according to TOP500. Summit represents the culmination of a multiyear effort between the OLCF, IBM, NVIDIA, and Mellanox to deliver a system that is unmatched for modeling, simulation, data analysis, and learning. To hit the ground running with science-ready applications on day one, application teams worked closely with the OLCF through the Center for Accelerated Application Readiness (CAAR) program for years in advance of the Summit deployment. CY 2019 was filled with outstanding results and accomplishments: a very high rating from users on overall satisfaction for the sixth year in a row; a tremendous amount of core-hours delivered to researchers from two leadership-class systems; and success in delivering on the allocation split of roughly 60%, 30%, and 10% of core-hours offered for the Innovative and Novel Computational Impact on Theory and Experiment (INCITE), Advanced Scientific Computing Research Leadership Computing Challenge (ALCC), and Director's Discretionary (DD) programs, respectively (see Operational Performance section). These accomplishments, coupled with the high utilization rates (overall and capability usage), represent the fulfillment of the promise of both leadership-class machines: efficient facilitation of leadership-class computational applications. Table ES.1 presents a summary of the 2019 OLCF metric targets and the associated results. More information can be found in the Operational Performance section for each OLCF resource. The scientific accomplishments of OLCF users are a strong indication of long-term operational success, with publications this year in such notable journals and publications as Nature, Nature Physics, Nature Plants, Physical Review X, Journal of the American Physical Society, Cell, Nano Letters, and Trends in Biotechnology. Crucial domain-specific discoveries facilitated by resources at the OLCF are described in the High Performance Computing Facility Operational Assessment 2019 Oak Ridge Leadership Computing Facility (OAR) Strategic Results section. For example, researchers used Summit to pinpoint and understand the production of proteins from genetic information, including mutations and the functional expression of disease (Section 8.2).

97 MATHEMATICS AND COMPUTING↗