At least 685 records · Page 38

The application of a time-domain deconvolution technique for identification of experimental acoustic-emission signals

A method is presented for the signature analysis of pulses by reconstructing in the time domain the shape of the pulse prior to its passing through the measurement system. This deconvolution technique is first evaluated using an idealized system and analytical pulse models and is shown to provide improved results. An experimental situation is then treated; system-component models are developed for the digitizer, tape recorder, filter, transducer and mechanical structure. To accommodate both calibration results and manufacturer's data, and to provide stable mathematical models entails considerable effort: some 30 parameters must be identified to model this system - which is still a substantial approximation - albeit of very high order. Experimental pulses generated by a ball drop, spark discharge and a tearing crack are then deconvoluted 'back through' the system as modeled, using this technique. These results are compared and indicate (a) that consistent shapes may be expected from a given type of source and (b) that some sources can be identified with greater clarity using the deconvolution approach.

Houghton, J. R.↗

The Ascent Air Data System for the Space Shuttle

The Ascent Air Data System (AADS) consists of a biconic spike probe on the nose of the Space Shuttle External Tank. The final configuration of the AADS was selected on the basis of pressure measurement accuracy and simplification of the configuration. Wind tunnel calibrations were formulated to convert the 30 deg/10 deg spike measured pressures to the desired air data parameters for postflight analyses. Estimates of the system performance show that in general the user requirements for angle of attack and sideslip, and dynamic pressure are met or only slightly exceeded by the estimated errors.

Hillje, E. R.↗

NOSS/ALDCS analysis and system requirements definition

The results of system analyses and implementation studies of an advanced location and data collection system (ALDCS) , proposed for inclusion on the National Oceanic Satellite System (NOSS) spacecraft are reported. The system applies Doppler processing and radiofrequency interferometer position location technqiues both alone and in combination. Aspects analyzed include: the constraints imposed by random access to the system by platforms, the RF link parameters, geometric concepts of position and velocity estimation by the two techniques considered, and the effects of electrical measurement errors, spacecraft attitude errors, and geometric parameters on estimation accuracy. Hardware techniques and trade-offs for interferometric phase measurement, ambiguity resolution and calibration are considered. A combined Doppler-interferometer ALDCS intended to fulfill the NOSS data validation and oceanic research support mission is also described.

Reed, D. L.↗

An improved model for the Earth's gravity field

An improved model for the Earth's gravity field, TEG-1, was determined using data sets from fourteen satellites, spanning the inclination ranges from 15 to 115 deg, and global surface gravity anomaly data. The satellite measurements include laser ranging data, Doppler range-rate data, and satellite-to-ocean radar altimeter data measurements, which include the direct height measurement and the differenced measurements at ground track crossings (crossover measurements). Also determined was another gravity field model, TEG-1S, which included all the data sets in TEG-1 with the exception of direct altimeter data. The effort has included an intense scrutiny of the gravity field solution methodology. The estimated parameters included geopotential coefficients complete to degree and order 50 with selected higher order coefficients, ocean and solid Earth tide parameters, Doppler tracking station coordinates and the quasi-stationary sea surface topography. Extensive error analysis and calibration of the formal covariance matrix indicate that the gravity field model is a significant improvement over previous models and can be used for general applications in geodesy.

Tapley, B. D.↗

The in-flight calibration of the Hubble Space Telescope fine guidance sensors

The Hubble Space Telescope (HST) fine guidance sensors are unique in the precision and performance levels being attempted; spacecraft control and astrometric research at the near milliarcsecond level are the ultimate goals. The inflight calibration of the sensors is presented, describing both the algorithms being used as well as the results achieved to date. The calibration items of principal interest are optical distortion, sensor magnification, and relative alignments. Calibration accuracies at the 20 milliarcsecond level have been achieved for specific data sets for optical distortion parameters. Unexpected variations occurring from Dec. 1990 - May 1991 in the magnification and alignment parameters are currently under investigation. Plans are being developed for new data acquisitions and reductions that should substantially improve HST pointing performance.

Welter, G. L.↗

The Primordial Inflation Explorer (PIXIE): A Nulling Polarimeter for Cosmic Microwave Background Observations

The Primordial Inflation Explorer (PIXIE) is a concept for an Explorer-class mission to measure the gravity-wave signature of primordial inflation through its distinctive imprint on the linear polarization of the cosmic microwave background. The instrument consists of a polarizing Michelson interferometer configured as a nulling polarimeter to measure the difference spectrum between orthogonal linear polarizations from two co-aligned beams. Either input can view the sky or a temperature-controlled absolute reference blackbody calibrator. Rhe proposed instrument can map the absolute intensity and linear polarization (Stokes I, Q, and U parameters) over the full sky in 400 spectral channels spanning 2.5 decades in frequency from 30 GHz to 6 THz (1 cm to 50 micron wavelength). Multi-moded optics provide background-limited sensitivity using only 4 detectors, while the highly symmetric design and multiple signal modulations provide robust rejection of potential systematic errors. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r < 10..3 at 5 standard deviations. The rich PIXIE data set can also constrain physical processes ranging from Big Bang cosmology to the nature of the first stars to physical conditions within the interstellar medium of the Galaxy.

Kogut, Alan J.↗

Conical Probe Calibration and Wind Tunnel Data Analysis of the Channeled Centerbody Inlet Experiment

For a multi-hole test probe undergoing wind tunnel tests, the resulting data needs to be analyzed for any significant trends. These trends include relating the pressure distributions, the geometric orientation, and the local velocity vector to one another. However, experimental runs always involve some sort of error. As a result, a calibration procedure is required to compensate for this error. For this case, it is the misalignment bias angles resulting from the distortion associated with the angularity of the test probe or the local velocity vector. Through a series of calibration steps presented here, the angular biases are determined and removed from the data sets. By removing the misalignment, smoother pressure distributions contribute to more accurate experimental results, which in turn could be then compared to theoretical and actual in-flight results to derive any similarities. Error analyses will also be performed to verify the accuracy of the calibration error reduction. The resulting calibrated data will be implemented into an in-flight RTF script that will output critical flight parameters during future CCIE experimental test runs. All of these tasks are associated with and in contribution to NASA Dryden Flight Research Center s F-15B Research Testbed s Small Business Innovation Research of the Channeled Centerbody Inlet Experiment.

Truong, Samson Siu↗

Quasi-Static and Dynamic Analysis of Composite Panels: Characterization and Validation

The predictive capability of a progressive damage model to simulate the quasi-static and dynamic crushing of composite specimens is evaluated in this article. The material model is commercially available within the ABAQUS finite element software package, i.e., “Damage for Fiber reinforced Composites”, and is often utilized to simulate damage progression and failure in static and dynamic failure scenarios such as crushing of a composite plate. The composite specimens used in this study consist of quasi-isotropic C-shaped and corrugated composite panels comprised of carbon fiber/epoxy braided fabric. The C-shaped panel specimen is used to calibrate the model and optimize material/model properties through comparison with experimental results. Then, using the same model parameters, the quasi-static crush response of the corrugated panel is predicted. The predictive capability of the model is further demonstrated by simulating the dynamic crushing response of both C-shaped and corrugated panels using the same material properties as in the quasi-static crush case with only minor adjustments for the dynamic elastic properties (i.e., rate dependent modulus). Results show that the in-built material model available in ABAQUS can successfully reproduce experimental results for both panels (C-shaped and corrugated) subjected to both quasi-static and dynamic loading scenarios. A small-scale parametric study on physical (experimentally measurable) and nonphysical (purely mathematical) model parameters was also conducted. It can be concluded that, achieving successful simulation results requires a more in-depth understanding of the influence of model parameter variation on the mechanical response of the composite together with the strategies and challenges of the utilized modeling methodology (e.g., FEA mesh density, etc.).

Naghipour Ghezeljeh, Paria↗

Feasibility of using Low-Cost COTS Sensors for Particulate Monitoring in Space Missions

Real-time measurement of particles suspended in the spacecraft cabin is of great importance to verify that maximum allowable dust concentrations are not exceeded. This is primarily to protect astronaut health, but also has implications for dust-sensitive equipment. Recently, there is growing interest in low-cost commercial off-the-shelf (COTS) particle sensors by air quality researchers for their ability to map concentrations of airborne particulate matter in various terrestrial settings. In addition to low cost (< $2,000), the compact size and minimal weight of these sensors make them a potential choice for space missions. The detection mechanism for these aerosol sensors is typically measurement of light scattered by particles as they flow through a sensing volume. The amount of scattered light for detection depends on the particle size, shape, density, and refractive index of the particle material. Ideally, particle instruments should be calibrated with reference instruments for each different type of aerosol measurement. In this study we review multiple parameters that may impact the performance of state-of-the-art low-cost aerosol sensors. Environmental factors such as temperature, relative humidity, low ambient pressure, radiation and charge environment, partial-gravity and microgravity can affect the accuracy of particle measurements. Characteristics of the dust aerosols including particle size distribution, aerosol composition, refractive index, morphology and concentration levels also affect the measurement accuracy. Finally, we look at these parameters and issues with respect to an example COTS low-cost aerosol sensor. Instrument performance specifications are evaluated, and experiments are performed to measure real-time concentrations of Arizona Road Dust (a terrestrial reference test dust) and lunar dust simulant in a laboratory chamber. Overall, this study provides insight for evaluating spacecraft particulate monitoring technologies and raises questions to be answered before incorporating low-cost COTS sensors in future space missions to dusty destinations.

lunar dust↗

Deriving Mercury Geodetic Parameters with Altimetric Crossovers from the Mercury Laser Altimeter (MLA)

Based on the previous applications of laser altimetry to planetary geodesy at GSFC, we use the recently developed PyXover software package to analyze altimetric crossovers from the Mercury Laser Altimeter (MLA). Using PyXover, we place new constraints on Mercury's geodetic parameters via least squares minimization of crossover discrepancies. We simultaneously solve for orbital corrections for each MLA ground track, for the geodetic parameters of the International Astronomical Union-recommended orientation model for Mercury (pole right-ascension and declination coordinates, prime meridian rotation rate, and librations), and for the Mercury's Love number h2. We calibrate the formal errors of our solution based on closed-loop simulations and on the level of robustness against a priori values, data selection, and parametrization. Our solution of the Mercury's rotational parameters is consistent with published values. In particular, our new estimate for the orientation of the pole places Mercury in a Cassini state, with an obliquity ϵ = 2.031 ± 0.03 arcmin compatible with previous “surface” related measurements. Moreover, we provide a first data-based estimate of the Love number h_(2) = 1.55 ± 0.65. The latter is consistent with expectations from models of Mercury's interior, although its precision does not enable their refinement.

S. Bertone↗

Calibration of the Mid-Infrared Tully-Fisher Relation

Distance measures on a coherent scale around the sky are required to address the outstanding cosmological problemsof the Hubble constant and of departures from the mean cosmic flow. The correlation between galaxy luminositiesand rotation rates can be used to determine the distances to many thousands of galaxies in a wide range ofenvironments potentially out to 200 Mpc. Mid-infrared (3.6m) photometry with the Spitzer Space Telescope isparticularly valuable as a source of luminosities because it provides products of uniform quality across the sky.From a perch above the atmosphere, essentially the total magnitude of targets can be registered in exposures ofa few minutes. Extinction is minimal and the flux is dominated by the light from old stars, which is expected tocorrelate with the mass of the targets.In spite of the superior photometry, the correlation between mid-infrared luminosities and rotation rates extractedfrom neutral hydrogen profiles is slightly degraded from the correlation found with I-band luminosities. A colorcorrection recovers a correlation that provides comparable accuracy to that available at the I band (20 1in an individual distance) while retaining the advantages identified above. Without color correction, the relationbetween linewidth and [3.6] magnitudes is Mb,i,k,a [3.6] 20.34 9.74(logWimx 2.5). This description is foundwith a sample of 213 galaxies in 13 clusters that define the slope and 26 galaxies with Cepheid or tip of the red giant branch distances that define the zero point. A color-corrected parameter MC[3.6] is constructed that has reduced scatter: MC[3.6] 20.34 9.13(logWimx 2.5). Consideration of the seven calibration clusters beyond 50 Mpc, outside the domain of obvious peculiar velocities, provides a preliminary Hubble constant estimate of H0 74 4 km s1 Mpc1.

Mid-Infrared↗

The Algorithm for MODIS Wavelength On-Orbit Calibration Using the SRCA

The Spectro-Radiometric Calibration Assembly (SRCA) provides on-orbit spectral calibration of the MODerate resolution Imaging Spectroradiometer (MODIS) reflected solar bands and this paper describes how it is accomplished. The SRCA has two adjacent exit slits: 1) Main slit and 2) Calibration slit. The output from the main slit is measured by a reference silicon photo-diode (SIPD) and then passes through the MODIS. The output from the calibration slit passes through a piece of didymium transmission glass and then it is measured by a calibration SIPD. The centroids of the sharp spectral peaks of a didymium glass are utilized as wavelength standards. After normalization using the reference SIPD signal to eliminate the effects of the illuminating source spectra, the calibration SIPD establishes the relationship between the peaks of the didymium spectra and the grating angle; this is accomplished through the grating equation. In the grating equation the monochromator parameters, Beta (half angle between the incident and diffractive beams) and Theta(sub off) (offset angle of the grating motor) are determined by matching, in a least square sense, the known centroid wavelengths of the didymium peaks and the calculated centroid grating angles from the calibration SIPD signals for the peaks. A displacement between the calibration SIPD and the reference SIPD complicates the signal processing.

Montgomery, Harry↗

The Algorithm for MODIS Wavelength On-Orbit Calibration using the SRCA

The Spectro-Radiometric Calibration Assembly (SRCA) provides on-orbit spectral calibration of the MODerate resolution Imaging Spectroradiometer (MODIS) reflected solar bands and this paper describes how it is accomplished. The SRCA has two adjacent exit slits: 1) Main slit and 2) Calibration slit. The output from the main slit is measured by a reference silicon photo-diode (SIPD) and then passes through the MODIS. The output from the calibration slit passes through a piece of didymium transmission glass and then it is measured by a calibration SIPD. The centroids of the sharp spectral peaks of a didyrnium glass are utilized as wavelength standards. After normalization using the reference SIPD signal to eliminate the effects of the illuminating source spectra, the calibration SIPD establishes the relationship between the peaks of the didymium spectra and the grating angle; this is accomplished through the grating equation. In the grating equation the monochromator parameters, beta (half angle between the incident and diffractive beams) and theta(sub ff) (offset angle of the grating motor) are determined by matching, in a least square sense, the known centroid wavelengths of the didymium peaks and the calculated centroid grating angles from the calibration SIPD signals for the peaks. A displacement between the calibration SIPD and the reference SIPD complicates the signal processing. The response of the MODIS bands to the SRCA output is also normalized by the reference SIPD signal to eliminate the effect of the source spectrum. That response differs from what is measured by MODIS using the Spectral Measurements Assembly (SpMA), a laboratory double-monochromator, due to the wider slit width of the SRCA. The SRCA slit function, calculated using measurements by the SPMA and the SRCA at the same MODIS temperature, will be used to recover the MODIS spectral response using the SRCA data measured on-orbit.

Montgomery, Harry↗

Solar wind iron abundance variations at speeds greater than 600 km/s, 1972-1976

An analysis has been conducted of the Fe/H ratios in the peaks of high-speed streams during the decline of solar cycle 20 and the following minimum (October 1972-December 1976). The response of the 50- to 200-keV ion channel of The Johns Hopkins University Applied Physics Laboratory energetic particle experiments (EPE) on IMP 7 and 8, which is (in the absence of energetic ions) dominated by solar wind iron ions at high solar wind speeds (V approximately equal to or greater than 600 km/s) as inferred from calibrations of flight spare detectors. The conducted Fe measurements have been compared with solar wind H and He parameters from the Los Alamos National Laboratory instruments on the same spacecraft. In general, the Fe distribution parameters (bulk velocity, flow direction, temperature) are found to be similar to the He parameters. Although the average Fe/H ratios found in the peaks of many steady high-speed streams agree within observational uncertainties with the nominal coronal ratio of 4.7 x 10 to the -5th, abundance variations of a factor of up to 6 are obtained across a given coronal-hole associated high-speed stream. There are, as well, a factor of 2 variations between stream-averaged abundances for recurrent high-speed streams emanating from different coronal holes occurring on the sun on the same solar rotation. Flare-related solar wind flows sometimes show Fe/H ratios enhanced by factors of 4-5 more than in coronal-hole associated, quiet-time streams, while in one case the Fe/H enhancement was still observable one rotation after the flare activity. Over the period 1973-1976, a steady decrease in the average quiet time Fe/H ratio by a factor of approximately 4 is measured on both IMP 7 and 8.

Mitchell, D. G.↗

L-band radar backscatter modeling of forest stands

An L-band HH radar backscatter model of a coniferous forest stand is described and compared with SIR-B L-band image data of the Mount Shasta region of northern California. Being based upon an identification and implementation of the expected major components of forest backscattering, the model is simple in form and thus fast computationally, making possible extensive simulations of forest stands. A particularly important component in the model relates to representing the specular reflections expected from tree trunks to the ground and then back to the sensor. These are strong returns and are seen to be necessary to explain both the forest measurements made by the authors and the observations of others. Although the experimental data is limited in quantity and quality, agreement between available experimental and simulated values of forest backscatter is better than the residual uncertainty and relative calibration error of the experimental data, provided the model and experiment are matched initially at one set of parameter values.

Richards, John A.↗

Robot geometry calibration

Autonomous robot task execution requires that the end effector of the robot be positioned accurately relative to a reference world-coordinate frame. The authors present a complete formulation to identify the actual robot geometric parameters. The method applies to any serial link manipulator with arbitrary order and combination of revolute and prismatic joints. A method is also presented to solve the inverse kinematic of the actual robot model which usually is not a so-called simple robot. Experimental results performed by utilizing a PUMA 560 with simple measurement hardware are presented. As a result of this calibration a precision move command is designed and integrated into a robot language, RCCL, and used in the NASA Telerobot Testbed.

Hayati, Samad↗

Synchronizing computer clocks using a local area network

Researchers completed the first tests of a method to synchronize the clocks of networked computers to the National Institute of Standards and Technology (NIST) time scale. The method uses a server computer to disseminate the time to other clients on the same local-area network. The server is synchronized to NIST using the ACTS protocol over a dial-up telephone line. The software in both the server and the parameters of this model are used to adjust the time of the local clock and the interval between calibration requests in a statistically optimum way. The algorithm maximizes the time between calibrations while at the same time keeping the time of the local clock correct within a specific tolerance. The method can be extended to synchronize computers linked over wide-area networks, and an experiment to test the performance of the algorithms over such networks is being planned.

Levine, Judah↗

Fuzzy control system for a remote focusing microscope

Space Station Crew Health Care System procedures require the use of an on-board microscope whose slide images will be transmitted for analysis by ground-based microbiologists. Focusing of microscope slides is low on the list of crew priorities, so NASA is investigating the option of telerobotic focusing controlled by the microbiologist on the ground, using continuous video feedback. However, even at Space Station distances, the transmission time lag may disrupt the focusing process, severely limiting the number of slides that can be analyzed within a given bandwidth allocation. Substantial time could be saved if on-board automation could pre-focus each slide before transmission. The authors demonstrate the feasibility of on-board automatic focusing using a fuzzy logic ruled-based system to bring the slide image into focus. The original prototype system was produced in under two months and at low cost. Slide images are captured by a video camera, then digitized by gray-scale value. A software function calculates an index of 'sharpness' based on gray-scale contrasts. The fuzzy logic rule-based system uses feedback to set the microscope's focusing control in an attempt to maximize sharpness. The systems as currently implemented performs satisfactorily in focusing a variety of slide types at magnification levels ranging from 10 to 1000x. Although feasibility has been demonstrated, the system's performance and usability could be improved substantially in four ways: by upgrading the quality and resolution of the video imaging system (including the use of full color); by empirically defining and calibrating the index of image sharpness; by letting the overall focusing strategy vary depending on user-specified parameters; and by fine-tuning the fuzzy rules, set definitions, and procedures used.

Weiss, Jonathan J.↗