Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “outage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Distributed Wind for Commercial Loads

Distributed wind can help meet on site energy and resilience needs for a wide variety of commercial loads .While it is a variable resource, it has predictable daily and annual production trends. The presence of on-site renewable generation can enhance resilience, supplying power for long periods of time without worrying about conserving fuel supply. The addition of properly sized storage or complementary solar resources can further reduce the challenges of intermittency and reduce the need for fuel-limited backup power during outage situations. This fact sheet explores further the energy and resilience requirements of commercial loads and how distributed wind may be a good match to meet their load needs.

20 FOSSIL-FUELED POWER PLANTS↗

Trends in Cybersecurity Threats to Clean Energy

As deployments of clean energy generation and storage assets continue to grow, the increased attack surface creates a greater risk for cyber threats, but is clean energy truly a target for cyber adversaries? This poster will present research on the trends in cyber incidents that have affected clean energy companies and assets as well as the trends in disclosed and exploited vulnerabilities. From a series of ransomware attacks on European wind manufacturers, to vulnerabilities exploited in solar assets to turn controllers into botnets, to attacks on communication infrastructure that have resulted in extended outages of remote control and monitoring, we explore the techniques used and the impacts to the clean energy sector. Key takeaways include understanding of how OT-focused malware is becoming more flexible and more destructive, how known vulnerabilities are being exploited, the growing number of IT and OT attacks that use built in tools and functionalities. Additionally, we highlight the presumed motivations and targeted sectors for various identified cyber adversaries. Viewers will leave with an understanding of how recent headlines fit into the development of cyberattack trends and what preventions they may need to take to protect against increasingly popular tactics.

14 SOLAR ENERGY↗

PV Reliability and Resilience in Challenging Climates

Challenging climates for Photovoltaics are usually based on climate classification. However, extreme weather events such as high wind, flooding, large hail, extreme snow etc. have become more ubiquitous globally. To study the impact of extraordinary weather events on PV reliability we used two of the largest databases in the USA. First, the National Oceanic and Atmospheric Administration (NOAA) database on extreme weather and secondly, the PV Fleet Data Initiative where we have collected high-resolution PV performance data of more than 8 gigawatts or about 6-7% of all commercial and utility systems in the USA. We analyzed almost 200 systems between 2008-20022 that were immediately impacted by these weather events. The immediate impact (outages) was determined to be about 1% of or a median of approximately 3 days of annual lost production. However, the risk these events pose is exemplified by a long tail where 0.4 % of all systems lost more than 2 weeks annual production. We also found a threshold for high wind (90 km/hr) and hail (25mm), above which we observed significantly higher degradation implying long-term damage to the systems. In addition, we are using satellite imagery to quantify visible damage to PV plants. Finally, we share module, design and installation lessons from some observed case studies to improve extreme weather resilience for PV power systems.

degradation↗

Progress towards the completion of the proton power upgrade project

The Proton Power Upgrade project at the Spallation Neutron Source at Oak Ridge National Laboratory will increase the proton beam power capability from 1.4 to 2.8 MW. Upon completion in early 2025, 2 MW of beam power will be available for neutron production at the existing first target station (FTS) with the remaining beam power available for the future second target station (STS). The project has installed seven superconducting radio-frequency (RF) cryomodules and supporting RF power systems to increase the beam energy by 30% to 1.3 GeV, and the beam current will be increased by 50%. The injection and extraction region of the accumulator ring are being upgraded, and a new 2 MW mercury target has been developed along with supporting equipment for high-flow gas injection to mitigate cavitation and fatigue stress. The first four cryomodules and supporting systems were commissioned in 2022-2023 and supported neutron production at 1.05 GeV, 1.7 MW with high reliability. The first-article 2 MW target was operated successfully for approximately 4400 MW-Hours over two run periods. The long outage began in August 2023 for installation of the remaining technical equipment and construction of the Ring-to-Target Beam Transport tunnel stub that will enable connection to the STS without interrupting operation of the FTS. The upgrade is proceeding on-schedule and on-budget, and resumption of neutron production for the user program is planned for July 2024.

Champion, Mark↗

Nuclear Requalification of the ATR Core

The Advanced Test Reactor (ATR) creates a unique, high neutron flux materials testing environment that subsequently causes neutron embrittlement damage to its beryllium reflector. The reflector is eventually required to be replaced during a reactor Outage. Concurrently, a piece-for-piece core replacement is conducted to maintain reactor functionality called a core internals changeout (CIC). Once changeout is complete, ATR Reactor Engineering utilizes previous CIC data, notably 1977-1994 CIC data, to conduct predictive criticality analysis on the new, unirradiated core. However, CIC data has been inconsistently reported over the years making it difficult, and in some cases impossible, to utilize. These inconsistencies arise in various forms of not using correct units, inconsistent diagram usage, and not portraying the same kind of data similarly across the reports. To work around this inconsistency issue, Reactor Engineering is implementing the use of several new neutronic modeling codes that utilize modern computation speeds and methods to model the new core in different criticality environments. Further validation is then conducted by nuclear testing and bringing the reactor critical and conducting various irradiation tests. Upon completion and certification that the reactor passed all testing requirements, ATR can once again re-start normal operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources: Preprint

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their \textit{autonomy} and \textit{privacy} through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

Development of Multiresolution Capabilities for the Holistic Energy Resource Optimization Network (HERON) tool A progress update

INL researchers work on technoeconomic analyses for integrated energy systems (IES) using the Framework for Optimization of ResourCes and Economics (FORCE). Within FORCE, researchers use the Holistic Energy Resource Optimization Network (HERON) tool to conduct optimization of grid portfolios under uncertain market conditions. These optimizations determine optimal capacities for all IES components and strategies for resource dispatch which maximize some economic metric (e.g., net present value). Resource dispatch occurs on finer timescales (typically hours) and thus are asked to respond to a given time series (e.g. hourly load demand profiles for a grid, or pre-determined electricity prices). Volatile and complex bidding dynamics as well as poorly forecasted weather events within deregulated markets add uncertainty to the time series; FORCE can address this uncertainty by training a reduced order model on historical time series and generate unique synthetic time series which represent individual scenarios or realizations of the market. The IES configuration can be simulated under these different sampled realizations and a stochastic optimization is conducted which optimizes the expected value of the desired economic metric. The training of a synthetic time series generator is limited by the chosen time resolution; dynamics can occur on different time scales. Seasonal demand trends can dominate faster dynamical events (such as power outages from certain sectors or severe weather events) which might not get captured correctly by the trained model. In this report, we investigate different ways of addressing the training and generation of time series on multiple time scales using three main algorithms: wavelet decomposition, dynamic mode decomposition, and generative adversarial networks for time series. We demonstrate a time series analysis that yields information on not just the frequency space but also temporal space: where a fast Fourier transform can provide what frequencies dominate, the new algorithms can provide when the frequencies dominate as well. These analyses can help improve IES optimization by allowing researchers to couple simulations at different timescales when it is most needed - seasonal, day-ahead, and real time optimization - with greater computational efficiency. Future work will include implementation of a subset of the proposed algorithms into the FORCE toolset and application of these analyses into multiple timescale optimization.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model engages a variety of customer types -- prosumers, flexible loads, critical/noncritical customers, and distributed generators -- as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining system-level power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Probabilistic Resource Adequacy Suite (PRAS)

Powered By PRAS features the Probabilistic Resource Adequacy Suite (PRAS), an open-source, research-oriented collection of tools for analyzing the resource adequacy of bulk power systems. PRAS performs low-fidelity, high-speed simulations of multi-region power system operations, considering hundreds of thousands of years of unplanned resource outages to quantify the risk and potential nature of energy supply shortfalls in probabilistic terms.

demand↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Physics-informed Data-driven Degradation and Prognostic For Hydropower System

The hydropower system is a cyber-physical system, and the industry is experiencing high operation and maintenance (O&M) costs along with increasing unplanned outages, primarily due to aging equipment and new asset loading patterns. Current (O&M) practices in asset management are predominantly reactive rather than predictive and systematic. To address these challenges, a proposed physics-informed data-driven degradation model aims to simulate the health of components in various environments. Its purpose is to accurately characterize wear and fatigue in the pilot components of hydropower systems. Additionally, the model provides informed confidence in prognostic predictions concerning asset degradation and remaining life.

13 HYDRO ENERGY↗

Leveraging Hydropower Multi-Sensor Data for Inference and Age-Informed Modeling

Increased demand of operational flexibility such as faster ramp up/down in generation, and more frequent start/stops are putting hydropower plants and their associated components in unprecedented stress. Consequently, these plants are at the high risk of extended and more frequent outage to accommodate unscheduled, and unexpected maintenance. Therefore, hydropower plants are in critical need of data driven and age-informed analysis for their regular and unscheduled operation. Yet not all hydropower plants are exhaustively equipped with sensors and/or measurement streams for their respective components – demanding solutions on how to detect, identify, and locate the cause of any event from the unobservable. Idaho National Laboratory (INL) analyzed the anonymized measurements and event records from the Hydropower Research Institute (HRI) to address this issue, as part of the Water Power Technologies Office (WPTO) funded one year multi-lab project. First, we investigated how time series of multiple sensor measurements can be leveraged to identify an event “root cause” as well as to develop an inference (i.e., estimate the unobservable) problem. INL also investigated how individual hydropower components’ reaction or response times vary across the pre-event, during event, and post-event conditions – enabling the hydropower dynamic models to be age-informed. Finally, the impact of clustering multi-sensor time series on short-term vibration prediction is analyzed. INL will present key findings from these analyses and recommend next steps for stakeholder adoption.

13 HYDRO ENERGY↗

Visualizing a Vulnerability: Its Connections to Hardware and Software

All Hazards Analysis (AHA) is a framework developed by Idaho National Laboratory that provides capabilities to collect, store, analyze, and visualize critical infrastructure information. A core function of AHA is its ability to simulate faults or outages in networks of infrastructure originating from a plethora of causes, ranging from natural disasters to cyberattacks. AHA utilizes Hardware and Software Bills of Material (HBOM and SBOM, respectively) along with Known Exploited Vulnerabilities (KEVs) to document the potential attack vectors for each piece of infrastructure. The objective of this contribution to AHA was to create a visualization tool that could capture the small details held in each individual artifact as well as preserve the large-scale connections that link them together to aid threat modeling.

58 GEOSCIENCES↗

Data Analytics and Visualization of Energy Systems for Critical Infrastructure Insights

Modernization of energy systems including transportation facilities provides opportunities for increased efficiency, expansion of commerce and meeting industry and federal goals. A significant increase in electrical demand is projected to meet these needs, which concentrates at facilities such as airports. For example, Xcel Energy working with two airports in their service area recently published information projecting an up to fivefold increase in electricity demand in the next 25 years [1]. Concurrently, the US Government Accountability Office (GAO) recently surveyed 30 commercial service airports identifying more than 300 outages of more than 5 minutes between 2015 and 2022 [2]. Power, reliability, and resilience planning becomes more important to safely maintain operations and the flow of commerce with fewer energy carriers providing necessary energy to safely move passengers and goods. NREL proposes to develop methodologies to allow owners, utilities, and federal agencies to dynamically analyze, forecast, and manage energy loads at airports, focused upon maintaining the flow of commerce in an efficient, sustainable, and resilient way. To address these energy challenges, a suite of technologies and methodologies can be leveraged to validate concepts, inform design, de-risk solutions and optimize energy management during deployment. These technologies include digitalization of energy systems, microgrid methodologies, and related energy technologies for building and vehicle loads. [1] Electrifying Airport Ecosystems - https://www.enterprisemobility.com/content/dam/enterpriseholdings/marketing/innovation-in-mobility/vehicle-innovation/airport-electrification-study-full-report-2024.pdf [2] Airport Infrastructure: Selected Airport's Efforts to Enhance Electrical Resilience https://www.gao.gov/products/gao-23-105203.

critcal infrastructure↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Characterization of Rare-earth Doped Thermal Barrier Coatings for Phosphor Thermometry

Thermal Barrier Coatings have been extensively used to protect and insulate the metallic components in turbine engines from extreme environments to achieve higher turbine inlet temperatures, resulting in an increase in combined engine cycle efficiency, lowering NOx emissions and fuel consumption. Additionally, as the major failure mechanisms determining lifetime are thermally activated during engine operation, uncertainty in temperature measurements affects lifetime prediction. Early detection of Thermal Barrier Coatings spallation symptoms, associated with local delamination induced temperature changes, can reduce forced engine outages. Further improvements are envisioned with the development of more reliable measurement techniques. For this purpose, Phosphor Thermometry has been considered a promising method for precision monitoring of turbine blade coatings that contain embedded phosphor dopants. In this work, a modified four-flux Kubelka-Munk model for luminescent rare-earth doped Thermal Barrier Coating configurations supported the design and the fabrication of viable sensing coatings for potential industrial implementation. Phosphor Thermometry instrumentation was developed with the objective of expanding capabilities of the technique, using a synchronized acquisition method on sensing coatings. Experiments on an innovative Erbium-Europium co-doped Yttria-Stabilized Zirconia coating have demonstrated the effectiveness of this advanced Phosphor Thermometry instrument with enhanced sensitivity and extended temperature range. Delamination progression monitoring was achieved for the first time using a Thermal Barrier Coating configuration subjected to indentation that includes a thin luminescent layer deposited on the surface and associating the multi-layer configuration with a predictive model that evaluates the advancement of the degradation of the coatings. To further ensure the integrity of the phosphor doped coatings, synchrotron X-ray diffraction was performed to characterize the specific residual strains and thermal expansion of the materials, determining mechanical robustness and compatibility with state-of-the-art Thermal Barrier Coatings. The outcomes of this work pave the way for in-situ temperature measurements on phosphor-doped turbine blade coatings with increased performance and accuracy.

Fouliard, Quentin↗

Best Practices for Resilience in Smart Grid-Interactive Efficient Buildings

The Federal Energy Management Program (FEMP) supports federal agencies' energy decisions with information and guidance on design, funding, and operations to ensure federal buildings are efficient and resilient. The modernization of building infrastructure and the evolution of buildings to support decarbonization involves complex implementation of multiple components across several systems. This includes energy-efficient equipment, on-site energy generation and storage systems, and control systems. These systems have operational modes that can operate more efficiently if they are able to behave responsively to the conditions of the electrical grid. These grid-interactive efficient buildings (GEB) allow facilities to manage power demand according to operational constraints and market signals issued by grid operators. With proper design and planning, these same capabilities have the potential to enable building and facility resilience - coordinating with microgrids, maintaining power on critical circuits to sustain essential operations, and monitoring building health and safety status during an outage. By managing the load of buildings, GEBs can also reduce the cost of backup generation and make better use of renewable power sources on site. This document outlines some of the processes and considerations to guide the design and operation of GEBs in ways that promote facility resilience.

building decarbonization↗