Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Zodiacal light dynamics experiment: A wideband imaging Fabry-Perot interferometer

The Solar Probe will provide an ideal platform from which to study dynamics of dust particles near the sun by measuring the detailed character of the Fraunhofer structure of the zodiacal light. The suggested instrument is a wideband imaging Fabry-Perot interferometer with state of the art technology in both the optics and the detector. The instrument would function as a high-resolution imaging device providing wavelength resolution of 0.03 A over about a 20 A range. The wideband imaging capability would provide sky maps of the zodiacal light on a despun spacecraft without mechanical scanning. The Solar Probe mission would allow the velocity distribution of the dust to be mapped along most of the trajectory of the spacecraft.

Torr, D. G.↗

Phase conjugate Twyman-Green interferometer for testing spherical surfaces and lenses and for measuring refractive indices of liquids or solid transparent materials

The present paper describes an application of a phase conjugate Twyman-Green interferometer using barium titanate as a self-pumping mirror for testing optical components like concave and convex spherical mirrors and lenses. The aberrations introduced by the beam splitter while testing concave or convex spherical mirrors of large aperture are automatically eliminated due to self-focussing property of the phase conjugate mirror. There is no necessity for a good spherical surface as a reference surface unlike in classical Twyman-Green interferometer or Williams interferometer. The phase conjugate Twyman Green interferometer with a divergent illumination can be used as a test plate for checking spherical surfaces. A nondestructive technique for measuring the refractive indices of a Fabry Perot etalon by using a phase conjugate interferometer is also suggested. The interferometer is found to be useful for measuring the refractive indices of liquids and solid transparent materials with an accuracy of the order of + or - 0.0004.

Shukla, R. P.↗

A real time interferometry system for unsteady flow measurements

A simple real-time interferometer system was developed for use in dynamic stall and other unsteady flow research at compressible flow speeds. A conventional schlieren system was modified to operate as a point diffraction interferometer. The implementation of this interferometer is discussed, and results of trials with different point diffractors are presented in this paper. The performance of the interferometer under various flow conditions was investigated. Results are presented which show the effects of the interferometer parameters such as pinhole size and pinhole-plate optical density on the performance of the system.

Brock, N. J.↗

Evolutionary Design of Controlled Structures

Basic physical concepts of structural delay and transmissibility are provided for simple rod and beam structures. Investigations show the sensitivity of these concepts to differing controlled-structures variables, and to rational system modeling effects. An evolutionary controls/structures design method is developed. The basis of the method is an accurate model formulation for dynamic compensator optimization and Genetic Algorithm based updating of sensor/actuator placement and structural attributes. One and three dimensional examples from the literature are used to validate the method. Frequency domain interpretation of these controlled structure systems provide physical insight as to how the objective is optimized and consequently what is important in the objective. Several disturbance rejection type controls-structures systems are optimized for a stellar interferometer spacecraft application. The interferometric designs include closed loop tracking optics. Designs are generated for differing structural aspect ratios, differing disturbance attributes, and differing sensor selections. Physical limitations in achieving performance are given in terms of average system transfer function gains and system phase loss. A spacecraft-like optical interferometry system is investigated experimentally over several different optimized controlled structures configurations. Configurations represent common and not-so-common approaches to mitigating pathlength errors induced by disturbances of two different spectra. Results show that an optimized controlled structure for low frequency broadband disturbances achieves modest performance gains over a mass equivalent regular structure, while an optimized structure for high frequency narrow band disturbances is four times better in terms of root-mean-square pathlength. These results are predictable given the nature of the physical system and the optimization design variables. Fundamental limits on controlled performance are discussed based on the measured and fit average system transfer function gains and system phase loss.

Masters, Brett P.↗

Common path point diffraction interferometer using liquid crystal phase shifting

A common path point diffraction interferometer uses dyed, parallel nematic liquid crystals which surround an optically transparent microsphere. Coherent, collimated and polarized light is focused on the microsphere at a diameter larger than that of the microsphere. A portion of the focused light passes through the microsphere to form a spherical wavefront reference beam and the rest of the light is attenuated by the dyed liquid crystals to form an object beam. The two beams form an interferogram which is imaged by a lens onto an electronic array sensor and into a computer which determines the wavefront of the object beam. The computer phase shifts the interferogram by stepping up an AC voltage applied across the liquid crystals without affecting the reference beam.

Mercer, Carolyn R.↗

NASA Tech Briefs, November 2010

Topics covered include: Portable Handheld Optical Window Inspection Device; Salience Assignment for Multiple-Instance Data and Its Application to Crop Yield Prediction; Speech Acquisition and Automatic Speech Recognition for Integrated Spacesuit Audio Systems ; Predicting Long-Range Traversability from Short-Range Stereo-Derived Geometry; Browser-Based Application for Telemetry Monitoring of Robotic Assets; Miniature Low-Noise G-Band I-Q Receiver; Methods of Using a Magnetic Field Response Sensor Within Closed, Electrically Conductive Containers; Differential Resonant Ring YIG Tuned Oscillator; Microfabricated Segmented-Involute-Foil Regenerator for Stirling Engines; Reducing Seal Adhesion in Low Impact Docking Systems; Optimal Flow Control Design; Corrosion-Resistant Container for Molten-Material Processing; Reusable Hot-Wire Cable Cutter; Deployment of a Curved Truss; High-Volume Airborne Fluids Handling Technologies to Fight Wildfires; Modeling of Alkane Oxidation Using Constituents and Species; Fabrication of Lanthanum Telluride 14-1-11 Zintl High-Temperature Thermoelectric Couple; A Computer Model for Analyzing Volatile Removal Assembly; Analysis of Nozzle Jet Plume Effects on Sonic Boom Signature; Optical Sidebands Multiplier; Single Spatial-Mode Room-Temperature-Operated 3.0 to 3.4 micrometer Diode Lasers; Self-Nulling Beam Combiner Using No External Phase Inverter; Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis; Maximum Likelihood Time-of-Arrival Estimation of Optical Pulses via Photon-Counting Photodetectors; Handheld White Light Interferometer for Measuring Defect Depth in Windows; Decomposition Algorithm for Global Reachability on a Time-Varying Graph; Autonomous GN and C for Spacecraft Exploration of Comets and Asteroids; Efficient Web Services Policy Combination; Using CTX Image Features to Predict HiRISE-Equivalent Rock Density; Isolation of the Paenibacillus phoenicis, a Spore-Forming Bacterium; Monolithically Integrated, Mechanically Resilient Carbon-Based Probes for Scanning Probe Microscopy; Cell Radiation Experiment System; Process to Produce Iron Nanoparticle Lunar Dust Simulant Composite; Inversion Method for Early Detection of ARES-1 Case Breach Failure; Use of ILTV Control Laws for LaNCETS Flight Research;and Evaluating Descent and Ascent Trajectories Near Non-Spherical Bodies.

Source record↗

Space-based Interferometric Telescopes for the Far Infrared

We discuss concepts for deploying direct detection interferometers in space which are optimized for the wavelength range 40 meu to 500 meu. In particular we introduce two missions in NASA's current strategic plan: SPIRIT (SPace InfraRed Interferometric Telescope) and SPECS (Submillimeter Probe of the Evolution of Cosmic Structure).

infrared↗

Truncated non-linear interferometer-based sensor system

A truncated non-linear interferometer-based sensor system includes an input that receives an optical beam and a non-linear amplifier that generates a probe beam and a conjugate beam from the optical beam. The system's local oscillators are related to the probe beam and the conjugate beam. The system includes a sensor that transduces an input with the probe beam and the conjugate beam. The transduction detects changes in the phase of each of the probe beam and the conjugate beam. The system's phase sensitive detectors detect phase modulations between the respective local oscillators, the probe beam, and the conjugate beam and outputs phase signals based on detected phase modulations. The system measures phase signals indicative of the sensor's input resulting from a sum or difference of the phase signals. The measurement exhibits a quantum noise reduction in an intensity difference, a phase sum, or an amplitude difference quadrature.

47 OTHER INSTRUMENTATION↗

Demonstration of spectral calibration for stellar interferometry

A breadboard is under development to demonstrate the calibration of spectral errors in microarcsecond stellar interferometers. Analysis shows that thermally and mechanically stable hardware in addition to careful optical design can reduce the wavelength dependent error to tens of nanometers. Calibration of the hardware can further reduce the error to the level of picometers. The results of thermal, mechanical and optical analysis supporting the breadboard design will be shown.

spectral calibration↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

A Transportable Gravity Gradiometer Based on Atom Interferometry

A transportable atom interferometer-based gravity gradiometer has been developed at JPL to carry out measurements of Earth's gravity field at ever finer spatial resolutions, and to facilitate high-resolution monitoring of temporal variations in the gravity field from ground- and flight-based platforms. Existing satellite-based gravity missions such as CHAMP and GRACE measure the gravity field via precise monitoring of the motion of the satellites; i.e. the satellites themselves function as test masses. JPL's quantum gravity gradiometer employs a quantum phase measurement technique, similar to that employed in atomic clocks, made possible by recent advances in laser cooling and manipulation of atoms. This measurement technique is based on atomwave interferometry, and individual laser-cooled atoms are used as drag-free test masses. The quantum gravity gradiometer employs two identical atom interferometers as precision accelerometers to measure the difference in gravitational acceleration between two points (Figure 1). By using the same lasers for the manipulation of atoms in both interferometers, the accelerometers have a common reference frame and non-inertial accelerations are effectively rejected as common mode noise in the differential measurement of the gravity gradient. As a result, the dual atom interferometer-based gravity gradiometer allows gravity measurements on a moving platform, while achieving the same long-term stability of the best atomic clocks. In the laboratory-based prototype (Figure 2), the cesium atoms used in each atom interferometer are initially collected and cooled in two separate magneto-optic traps (MOTs). Each MOT, consisting of three orthogonal pairs of counter-propagating laser beams centered on a quadrupole magnetic field, collects up to 10(exp 9) atoms. These atoms are then launched vertically as in an atom fountain by switching off the magnetic field and introducing a slight frequency shift between pairs of lasers to create a moving rest frame for the trapped atoms. While still in this moving-frame molasses, the laser frequencies are further detuned from the atomic resonance (while maintaining this relative frequency shift) to cool the atom cloud's temperature to 2 K or below, corresponding to an rms velocity of less than 2 cm/s. After launch, the cold atoms undergo further state and velocity selection to prepare for atom interferometry. The atom interferometers are then realized using laser-induced stimulated Raman transitions to perform the necessary manipulations of each atom, and the resulting interferometer phase is measured using laser-induced fluorescence for state-normalized detection. More than 20 laser beams with independent controls of frequency, phase, and intensity are required for this measurement sequence. This instrument can facilitate the study of Earth's gravitational field from surface and air vehicles, as well as from space by allowing gravity mapping from a low-cost, single spacecraft mission. In addition, the operation of atom interferometer-based instruments in space offers greater sensitivity than is possible in terrestrial instruments due to the much longer interrogation times available in the microgravity environment. A space-based quantum gravity gradiometer has the potential to achieve sensitivities similar to the GRACE mission at long spatial wavelengths, and will also have resolution similar to GOCE for measurement at shorter length scales.

Yu, Nan↗

The optical very large array and its moon-based version

An Optical Very Large Array (OVLA) is currently in early prototyping stages for ground-based sites, such as Mauna Kea and perhaps the VLT site in Chile. Its concept is also suited for a moon-based interferometer. With a ring of bi-dimensionally mobile telescopes, there is maximal flexibility in the aperture pattern, and no need for delay lines. A circular configuration of many free-flying telescopes, TRIO, is also considered for space interferometers. Finally, the principle of gaseous mirrors may become applicable for moon-based optical arrays. Fifteen years after the first coherent linkage of two optical telescopes, the design of an ambitious imaging array, the OVLA, is now well advanced. Two 1.5 m telescopes have been built and now provide astronomical results. Elements of the OVLA are under construction. Although primarily conceived for ground-based sites, the OVLA structure appears to meet the essential requirements for operation on the Moon.

Labeyrie, Antoine↗

Ultra-Low Noise Laser and Optical Frequency Comb-Based Timing System for the Event Horizon Explorer (EHE) Mission

Very Long Baseline Interferometry (VLBI) requires a highly stable time reference and synchronization system to maintain coherence between observations recorded independently at multiple stations – for example, the array of ground-based radio telescopes that comprise the Event Horizon Telescope (EHT). Instability in the time reference or inaccuracy in the synchronization impacts phase conference and reduces the performance of the VLBI system. For space-based telescopes like the Event Horizon Explorer (EHE) mission, the precision timing system must meet the size, weight, and power (SWaP) constraints of the spacecraft platform and be capable of operating in the space environment. The EHE mission is a proposed extension to the EHT that can improve the angular and time resolution of observations by enabling longer interferometric baselines than are possible on the Earth and sampling a wide range of Fourier spatial frequencies throughout the orbital motion. In this effort, we demonstrate the performance of one option for the EHE mission: the use of a space-qualified, ultra-low noise laser developed as part of the Laser Interferometer Space Antenna (LISA) mission as the timing reference, and an optical frequency comb to transfer the stability of this laser to the microwave regime for instrumentation use. We describe the implementation of the microwave down-conversion, in which the LISA cavity-stabilized laser is locked to a self-referenced optical frequency comb to divide the optical frequency down to 100 MHz. The phase noise of the 100 MHz signal is measured and validated using a phase noise analyzer that is referenced to a separate laboratory ultra-stable laser system. We present the results of this experiment, which demonstrates that the performance of this system meets the EHE requirement: a relative frequency error of 1e-14 from 1 to 30 seconds.

Hannah Tomio↗

Thermal Stability Analysis for a Heliocentric Gravitational Radiation Detection Mission

The Laser Interferometer Space Antenna (LISA) mission is designed for detailed studies of low-frequency gravitational radiation. The mission is currently a candidate for ESA's post-Horizon 2000 program. Thermal noise affects the measurement in at least two ways. Thermal variation of the length of the optical cavity to which the lasers are stabilized introduces phase variations in the interferometer signal, which have to be corrected for by using data from the two arms separately.

Laser Interferometer Space Antenna LISA gravitatio↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

Optically thin cirrus clouds over oceans and possible impact on sea surface temperature of warm pool in western Pacific

Over the convectively active tropical ocean regions, the measurement made from space in the IR and visible spectrum have revealed the presence of optically thin cirrus clouds, which are quite transparent in the visible and nearly opaque in the IR. The Nimbus-4 IR Interferometer Spectrometer (IRIS), which has a field of view (FOV) of approximately 100 km, was utilized to examine the IR optical characteristics of these cirrus clouds. From the IRIS data, it was observed that these optically thin cirrus clouds prevail extensively over the warm pool region of the equatorial western Pacific, surrounding Indonesia. It is found that the seasonal cloud cover caused by these thin cirrus clouds exceeds 50 percent near the central regions of the warm pool. For most of these clouds, the optical thickness in the IR is less than or = 2. It is deduced that the dense cold anvil clouds associated with deep convection spread extensively and are responsible for the formation of the thin cirrus clouds. This is supported by the observation that the coverage of the dense anvil clouds is an order of magnitude less than that of the thin cirrus clouds. From these observations, together with a simple radiative-convective model, it is inferred that the optically thin cirrus can provide a greenhouse effect, which can be a significant factor in maintaining the warm pool. In the absence of fluid transports, it is found that these cirrus clouds could lead to a runaway greenhouse effect. The presence of fluid transport processes, however, act to moderate this effect. Thus, if a modest 20 W/sq m energy input is considered to be available to warm the ocean, then it is found that the ocean mixed-layer of a 50-m depth will be heated by approximately 1 C in 100 days.

Prabhakara, C.↗

Advanced Optical Measurement Techniques

This research analyzes four areas: (1) Improved Techniques for Optical Measurement; (2) KC-135 Low Gravity Simulation Flight Preparation; (3) In-Line Holographic Microscopy; and (4) Holographic Optical Schlieren System (HOSS). The first task provides for laboratory breadboarding of advanced optical measurement techniques which appear promising for use in Material Processing System (MPS) flight experiments. A laboratory schlieren system has been constructed which simulates a similar optical system on the Fluids Experiment System (FES) which is to be flown on Spacelab 3. The second task allows improved optical systems and breadboards to be built for experiments and hardware tests on the KC-135 aircraft. A new, more stable Mach-Zehnder interferometer has been developed and components have been ordered. The third task is concerned with improvements on the optical system being used to study immiscible fluids. Experiments studying the dynamics of nucleation and the separation of immiscible fluids have been conducted. The four task involves building breadboard reconstruction systems for holograms taken in the HOSS. The HOSS is an early prototype of the Fluids Experiments System (FES) which is scheduled to fly on Spacelab 3.

Owen, R. B.↗