Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operational carbon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Exploring the Feasibility of a Carbon Dioxide Storage Hub in Western North Dakota

The University of North Dakota Energy & Environmental Research Center (EERC) and project partner ONEOK, Inc. (ONEOK) are investigating the feasibility of establishing a CO2 (carbon dioxide) storage hub in western North Dakota—in the heart of the Williston Basin. The conceived Roughrider Carbon Storage Hub would store CO2 captured from six gas-processing plants owned and operated by project partner ONEOK and a planned gas-to-liquids plant. This 2-year U.S. Department of Energy-sponsored Carbon Storage Assurance Facility Enterprise (CarbonSAFE) Phase II feasibility study is evaluating the aggregation of the CO2 captured from these seven sources for injection into stacked geologic storage complexes. The proposed hub includes several aspects that make it a highly qualified candidate for a feasibility study with a notably reduced project risk profile. These include 1) a project partner (ONEOK) with a committed goal to reduce greenhouse gas emissions; 2) prior subsurface data analysis supporting a potential stacked storage configuration with adequate CO2 storage resource; 3) commitment from local, regional, and state-level stakeholders; and 4) a state with U.S. Environmental Protection Agency underground injection control Class VI primacy. ONEOK’s assets in the Williston Basin provide significant environmental benefits by capturing and processing natural gas that may otherwise be flared or vented. Storing CO2 from these gas-processing facilities will reduce overall CO2 emissions in the basin while providing essential services to producers there and contributing to continued energy independence in the domestic markets.

03 NATURAL GAS↗

The Impact of Back-Sputtered Carbon on the Accelerator Grid Wear Rates of the NEXT and NSTAR Ion Thrusters

A study was conducted to quantify the impact of back-sputtered carbon on the downstream accelerator grid erosion rates of the NEXT (NASA's Evolutionary Xenon Thruster) Long Duration Test (LDT1). A similar analysis that was conducted for the NSTAR (NASA's Solar Electric Propulsion Technology Applications Readiness Program) Life Demonstration Test (LDT2) was used as a foundation for the analysis developed herein. A new carbon surface coverage model was developed that accounted for multiple carbon adlayers before complete surface coverage is achieved. The resulting model requires knowledge of more model inputs, so they were conservatively estimated using the results of past thin film sputtering studies and particle reflection predictions. In addition, accelerator current densities across the grid were rigorously determined using an ion optics code to determine accelerator current distributions and an algorithm to determine beam current densities along a grid using downstream measurements. The improved analysis was applied to the NSTAR test results for evaluation. The improved analysis demonstrated that the impact of back-sputtered carbon on pit and groove wear rate for the NSTAR LDT2 was negligible throughout most of eroded grid radius. The improved analysis also predicted the accelerator current density for transition from net erosion to net deposition considerably more accurately than the original analysis. The improved analysis was used to estimate the impact of back-sputtered carbon on the accelerator grid pit and groove wear rate of the NEXT Long Duration Test (LDT1). Unlike the NSTAR analysis, the NEXT analysis was more challenging because the thruster was operated for extended durations at various operating conditions and was unavailable for measurements because the test is ongoing. As a result, the NEXT LDT1 estimates presented herein are considered preliminary until the results of future posttest analyses are incorporated. The worst-case impact of carbon back-sputtering was determined to be the full power operating condition, but the maximum impact of back-sputtered carbon was only a four percent reduction in wear rate. As a result, back-sputtered carbon is estimated to have an insignificant impact on the first failure mode of the NEXT LDT at all operating conditions.

Soulas, George C.↗

Membrane Separation of Gases From The Martian Atmosphere

A test bed has been constructed to test membrane modules for separation of gases under temperature and pressure conditions normally encountered on the surface of Mars. The test bed allows independent control of (1) feed flow rates, (2) feed composition, (3) feed pressure, (4) permeate pressure, and (5) operating temperature. Preliminary data obtained at a nominal feed pressure of 760 torr and permeate pressure of 10 torr has demonstrated the ability of one membrane module to operate at temperatures as low as -70 C. At temperatures below -40 C, however, significant loss of carbon dioxide and argon was observed, probably indicating condensation at the relatively high pressure used. As expected, permeation flow rates decreased with decreasing temperature, the flow at -30 C approximately 37% of the value at +23 C. Values of permeability for individual gas components showed similar decreases with decreasing temperature, but permeability ratios changed significantly. For example, the ratio of the permeabilities of carbon dioxide and nitrogen increased from 2.6 at 23 C to 5.6 at -30 C. Additional data at lower operating pressures and temperatures must be obtained in order to optimize design of a usable separation system.

Jennings, Paul A.↗

Membrane Separation of Gases from the Martian Atmosphere

A test bed has been constructed to test membrane modules for separation of gases under temperature and pressure conditions normally encountered on the surface of Mars. The test bed allows independent control of: (1) feed flow rates, (2) feed composition, (3) feed pressure, (4) permeate pressure, and (5) operating temperature. Preliminary data obtained at a nominal feed pressure of 760 torr and permeate pressure of 10 torr has demonstrated the ability of one membrane module to operate at temperatures as low as -70 C. At temperatures below -40 C, however, significant loss of carbon dioxide and argon was observed, probably indicating condensation at the relatively high pressure used. As expected, permeation flow rates decreased with decreasing temperature, the flow at -30 C approximately 37% of the value at +23 C. Values of permeability for individual gas components showed similar decreases with decreasing temperature, but permeability ratios changed significantly. For example, the ratio of the permeabilities of carbon dioxide and nitrogen increased from 2.6 at 23 C to 5.6 at -30 C. Additional data at lower operating pressures and temperatures must be obtained in order to optimize design of a usable separation system.

Jennings, Paul A.↗

Heat Based Power Augmentation for Modular Pumped Hydro Storage in Smart Buildings Operation

In the U.S., building sector is responsible for around 40% of total energy consumption and contributes about 40% of carbon emissions since 2012. Within the past several years, various optimization models and control strategies have been studied to improve buildings energy efficiency and reduce operational expenses under the constraints of satisfying occupants’ comfort requirements. However, the majority of these studies consider building electricity demand and thermal load being satisfied by unidirectional electricity flow from the power grid or on-site renewable energy generation to electrical and thermal home appliances. Opportunities for leveraging low grade heat for electricity have largely been overlooked due to impracticality at small scale. In 2016, a modular pumped hydro storage technology was invented in Oak Ridge National Laboratory, named Ground Level Integrated Diverse Energy Storage (GLIDES). In GLIDES, employing high efficiency hydraulic machinery instead of gas compressor/turbine, liquid is pumped to compress gas inside high-pressure vessel creating head on ground-level. This unique design eliminates the geographical limitation associated with existing state of the art energy storage technologies. It is easy to be scaled for building level, community level and grid level applications. Using this novel hydro-pneumatic storage technology, opportunities for leveraging low-grade heat in building can be economical. In this research, the potential of utilizing low-grade thermal energy to augment electricity generation of GLIDES is investigated. Since GLIDES relies on gas expansion in the discharge process and the gas temperature drops during this non-isothermal process, available thermal energy, e.g. from thermal storage, Combined Cooling, Heat and Power system (CCHP), can be utilized by GLIDES to counter the cooling effect of the expansion process and elevate the gas temperature and pressure and boost the roundtrip efficiency. Several groups of comparison experiments have been conducted and the experimental results show that a maximum 12.9% cost saving could be achieved with unlimited heat source for GLIDES, and a moderate 3.8% cost improvement can be expected when operated coordinately with CCHP and thermal energy storage in a smart building.

Chen, Yang↗

Conformal LiF Stabilized Interfaces via Electrochemical Fluorination on High Voltage Spinel Cathodes (≈4.9 V) for Lithium-Ion Batteries

The high voltage LiNi 0.5 Mn 1.5 O 4 (LNMO) spinel is one of the promising cathodes for the lithium-ion batteries due to its high energy densities, good rate performance. However, its high operating potential (≈4.75 V) causes extensive oxidation of conventional carbonate electrolytes, resulting an unstable and thick cathode electrolyte interphase (CEI) layer with a large irreversible capacity and low coulombic efficiency. In this work, we report the formation of thin LiF stabilized interfaces on LNMO via electrochemical fluorination that significantly improves the cycling stability and enhanced the capacity. An electrochemically induced conformal LiF layer acts as a part of a robust CEI by reducing the leakage of electrons and allowing the conduction of Li ions through it. Because of the robust LiF stabilized CEI, LNMO delivers a discharge capacity of ≈148.5 and ≈117.1 mAh g -1 at 0.1 and 1 C rate, respectively. It exhibits excellent cyclability with 80% capacity retention (CR) after 600 cycles in lithium-half cell and ≈90% CR after 200 cycles in full cell with only 0.03% and 0.05% capacity decay per cycle in conventional carbonate electrolytes without additives. Such an excellent electrochemical performance could lead to the potential development of high energy density batteries with high voltage cathodes for grid-based applications.

25 ENERGY STORAGE↗

Lithium Storage Mechanisms and Electrochemical Behavior of a Molybdenum Disulfide Nanoparticle Anode

This study investigates the electrochemical behavior of molybdenum disulfide (MoS 2 ) as an anode in Li-ion batteries, focusing on the extra capacity phenomenon. Employing advanced characterization methods such as in situ and ex situ X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, and transmission electron microscopy, the research unravels the complex structural and chemical evolution of MoS 2 throughout its cycling. A key discovery is the identification of a unique Li intercalation mechanism in MoS 2 , leading to the formation of reversible Li x MoS 2 phases that contribute to the extra capacity of the MoS 2 electrode. Density function theory calculations suggest the potential for overlithiation in MoS 2 , predicting Li 5 MoS 2 as the most energetically favorable phase within the lithiation–delithiation process. Additionally, the formation of a Li-rich phase on the surface of Li 4 MoS 2 is considered energetically advantageous. After the first discharge, the battery system engages in two main reactions. One involves operation as a Li-sulfur battery within the carbonate electrolyte, and the other is the reversible intercalation and deintercalation of Li in Li x MoS 2 . The latter reaction contributes to the extra capacity of the battery. The incorporation of reduced graphene oxide as a conductive additive in MoS 2 electrodes notably improves their rate capability and cycling stability.

Lithium Rich Phase↗

OR-AGENT framework – Architecting electrified heavy-duty drayage applications

The widespread adoption of zero-emission vehicles in heavy-duty (HD) commercial freight transportation faces considerable technoeconomic challenges. For heavy-duty trucks, ensuring high uptime, cost parity with diesel, and safety standards is especially critical as these vehicles operate over long distances with heavy loads, where any downtime or off-nominal behaviors significantly impacts logistics, productivity, and the total cost of ownership. Unlike traditional diesel refueling, BEV charging infrastructure must be co-optimized with vehicle deployment, operational demands, and grid capacity to ensure cost-effective and reliable freight operations. However, the lack of a standardized ownership and service model has led to a fragmented approach—where commercial vehicle operators may invest in, own, and maintain both vehicle/batteries and charging/energy infrastructure. This disconnect may exclude energy service providers from the equation, forcing fleet operators to explore ‘behind-the-fence’ energy solutions that increase capital investment, operational downtime, overhead costs, and, in some cases, net carbon emissions. To address these issues, this study introduces OR-AGENT (Optimal Regional Architecture Generation for Efficient National Transport), a comprehensive modeling framework that integrates powertrain architectures, charging infrastructures, and energy backbone systems into a cohesive strategy. In this paper, OR-AGENT is applied to develop an interconnected systems architecture for energy efficiency and resiliency enhancement of heavy-duty drayage vehicles at the Port of Savannah, GA. This framework showcases an interconnected systems approach to electrifying heavy-duty drayage vehicles at the Port of Savannah, GA. The study assessed BEVs with 400–1200 kWh battery capacities, accounting for seasonal variations in weather and freight routing. A diverse charging mix (150 kW–1250 kW) was evaluated alongside grid capacity constraints, cost, and carbon intensity analysis, leading to the development of a strategic microgrid/Distributed Energy Resources (DER) deployment architecture to ensure a reliable and sustainable transition. However, the findings also highlight the need for alternative zero-emission solutions for remaining trips, such as larger batteries, electrified roadways, hydrogen powertrains, or net-zero emission fuels. In conclusion, the findings are incorporated into a Total Cost of Ownership (TCO) model to identify optimal architectures for an interconnected electrified ecosystem.

Commercial vehicles↗

Effects of various parameters of different porous transport layers in proton exchange membrane water electrolysis

Porous transport layers (PTLs) play an important role in proton exchange membrane water electrolysis (PEMWE) cells. The PTL facilitates water and gas transport, as well as thermal and electrical conduction, and is required to sustain good contact with adjacent components. It is expected that using PTLs with variations in material properties such as structure, composition, thickness and wettability results in performance changes of the PEMWE. Here, a general mathematical PEMWE model is developed that separates and analyzes the contributions of ohmic, activation, diffusion and Nernst potentials. For model validation, three inherently different anode PTL structures (carbon paper, sintered titanium particles, and titanium felt) are operated over a range of conditions. Additionally, the effects of PTL wettability were used to verify the model using Polytetrafluoroethylene (PTFE) treated Toray papers with PTFE loading ranging from 0% to 20%. The modeling results of both PTFE treated and untreated materials show good agreement with the experimental data. Mass transport or diffusion loss is the primary reason for performance differences between PTFE treated and untreated PTLs. Sintered titanium PTLs with thicknesses above 1 mm suffer from up to 33% increased ohmic losses without indicating any obvious changes in activation and diffusion losses when compared to untreated PTLs. The losses of the cell increase when using PTFE treated Toray paper. Individual contributions are quantified and assigned to increased ohmic, activation, and diffusion losses. In conclusion, the proposed model offers insights into the overpotential contributions of a PEMWE. It is a useful tool for predicting performance of various PTL materials and can be applied for PTL development and optimization efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inertia-induced mixing and reaction maximization in laminar porous media flows

Solute transport and biogeochemical reactions in porous and fractured media flows are controlled by mixing, as are subsurface engineering operations such as contaminant remediation, geothermal energy production, and carbon sequestration. Porous media flows are generally regarded as slow, so the effects of fluid inertia on mixing and reaction are typically ignored. Here, we demonstrate through microfluidic experiments and numerical simulations of mixing-induced reaction that inertial recirculating flows readily emerge in laminar porous media flows and dramatically alter mixing and reaction dynamics. An optimal Reynolds number that maximizes the reaction rate is observed for individual pore throats of different sizes. This reaction maximization is attributed to the effects of recirculation flows on reactant availability, mixing, and reaction completion, which depend on the topology of recirculation relative to the boundary of the reactants or mixing interface. Recirculation enhances mixing and reactant availability, but a further increase in flow velocity reduces the residence time in recirculation, leading to a decrease in reaction rate. The reaction maximization is also confirmed in a flow channel with grain inclusions and randomized porous media. Interestingly, the domain-wide reaction rate shows a dramatic increase with increasing Re in the randomized porous media case. This is because fluid inertia induces complex three-dimensional flows in randomized porous media, which significantly increases transverse spreading and mixing. This study shows how inertial flows control reaction dynamics at the pore scale and beyond, thus having major implications for a wide range of environmental systems.

Chen, Michael A. (ORCID:0000000294614710)↗

Evaluating the Effect of Vane Trailing Edge Flow on Turbine Rim Sealing

Abstract Modern gas turbine development continues to move toward increased overall efficiency, driven in part by higher firing temperatures that point to a need for more cooling air to prevent catastrophic component failure. However, using additional cooling flow bled from the upstream compressor causes a corresponding detriment to overall efficiency. A primary candidate for cooling flow optimization is purge flow, which contributes to sealing the stator–rotor cavity and prevents ingestion of hot main gas path (MGP) flow into the wheelspace. Previous research has identified that the external main gas path flow physics play a significant role in driving rim seal ingestion. However, the potential impact of other cooling flow features on ingestion behavior, such as vane trailing edge (VTE) flow, is absent in the open literature. This paper presents experimental measurements of rim cavity cooling effectiveness collected from a one-stage turbine operating at engine-representative Reynolds and Mach numbers. Carbon dioxide (CO2) was used as a tracer gas in both the purge flow and vane trailing edge flow to investigate flow migration into and out of the wheelspace. Results show that the vane trailing edge flow does in fact migrate into the rim seal and that there is a superposition relationship between individual cooling flow contributions. Computational fluid dynamics (CFD) simulations using unsteady Reynolds-averaged Navier–Stokes (URANS) were used to confirm VTE flow ingestion into the rim seal cavity. Radial and circumferential traverse surveys were performed to quantify cooling flow radial migration through the main gas path with and without vane trailing edge flow. The surveys confirmed that vane trailing edge flow is entrained into the wheelspace as purge flow is reduced. Local CO2 measurements also confirmed the presence of VTE flow deep in the wheelspace cavity.

Engineering↗

Data-Driven Co-optimization of Energy Efficiency and Indoor Environmental Quality in Commercial Buildings

In this paper, we use publicly available data of a highly instrumented building to estimate how zonal temperature and carbon dioxide (CO2) concentration are related to some key operational and environmental measurements. Subsequently, we have developed, simulated, and evaluated an optimization framework for minimizing the energy consumption of the central heating, ventilation and air conditioning (HVAC) unit while meeting zonal temperature and indoor air quality (IAQ) standards. Finally, we have evaluated the achievable energy savings for our proposed approach as compared to a baseline approach and reported significant savings potential.

Naqvi, Syed Ahsan Raza↗

MCM (Marine Carbon Management) [SWR-24-122]

The marine carbon management software is an open-source Python based software that contains generic models for marine carbon capture, marine carbon dioxide removal, marine carbon capture and utilization, marine carbon capture and storage. The models include design parameters, operational conditions and scenarios and technology costs.

Niffenegger, James↗

Particulate organic matter (POM) transport and transformation at the terrestrial-aquatic interface (Final Report)

This project investigates the input, transport, and degradation of particulate organic matter (POM) in near-surface riverbed sediments at the Hanford 300 Area of the Columbia River, a dynamic, regulated river system influenced by upstream dam operations. Riverbed sediments are biogeochemical hot spots where organic carbon inputs stimulate intense microbial activity, affecting nutrient cycling and redox transformations in the hyporheic zone (HZ). While dissolved organic matter (DOM) cycling has been studied extensively, little is known about the infiltration and transformation of POM—particularly under variable flow regimes common in large, regulated rivers.

54 ENVIRONMENTAL SCIENCES↗

Glass Furnace Decarbonization Technology Stack (Final Technical Report)

This report summarizes the objectives, approach, and outcomes of the Glass Furnace Decarbonization Technology Stack project undertaken by Owens-Brockway Glass Container Incorporated under award number DE-CD0000093. The project aimed to implement a pioneering combination of furnace technologies at the Zanesville, OH manufacturing site to reduce carbon intensity (CI) by 20–40% compared to baseline operations. The proposed Furnace Technology Stack included a Gas/Oxy-fuel system, OPTIMELT™ Heat Recovery System, raw material pre-heating, electric boosting, and forehearth electrification—designed to demonstrate commercial feasibility and drive industry-wide decarbonization.

42 ENGINEERING↗

Low-Temperature Plasma-Based Metrology of Lithium-Ion Battery Electrode Materials (CRADA Final Report)

As part of the Cyclotron Road program, SirenOpt Inc. evaluated its low-temperature plasma-based metrology sensor prototype for measuring multiple critical properties of lithium-ion battery electrode materials in parallel and in real-time. Cost-effective, minimal-waste manufacturing of high-performance battery electrode materials will be vital for achieving society’s net-zero carbon emission goals. Because existing electrode metrology sensors cannot operate within most sections of manufacturing lines, manufacturers often complete hundreds of processing steps before they can test their products and detect problems. When manufacturers perform these offline tests, they typically only test a small portion of the manufactured products. Current electrode manufacturing thus often yields many low-quality products, or off-spec products that must be thrown away all together. For example, at least 6% of the total lithium-ion battery manufacturing cost (i.e., over $250 million/year for the average gigafactory) is devoted to processing defective electrodes that are not scrapped until performance tests are failed during late-stage quality control checks. Electrode variability also leads manufacturers to build extra cells into battery packs to reduce the risk of poor performance. For example, many electric vehicle (EV) manufacturers include up to 10% more cells than needed, which substantially increases the cost and weight of the final EV product. The SirenOpt sensor can potentially enable early detection of poorly manufactured electrodes and allow them to be removed earlier from manufacturing lines, which can save battery manufacturers (hundreds of) millions of dollars per year. The sensor can further be used to improve product quality by accelerating R&D and process optimization, improving quality control, and enabling real-time process control. Overall, a real-time, in-situ metrology strategy can create unprecedented opportunities for implementation of smart manufacturing practices and advanced quality and process control solutions to realize higher battery electrode throughput and performance.

25 ENERGY STORAGE↗