Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “material sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Printed Electrochemical Sensor for Quantifying Bone Density Loss in Microgravity

Printed electrochemical biosensors have been developed for astronaut point-of-care testing. Our fabrication approach is complimentary with in-space manufacturing for an on-demand and hands-free fabrication process. These sensors are developed using a combination of thin film materials printing and 3D printing and are comprised of carbon nanotube, gold nanoparticle, silver nanoparticle and dielectric inks to make traditional electrochemical sensor devices. Initial prototyped printed electrochemical sensors demonstrate good electrochemical performance while also displaying low batch to batch variability. Here we report the development of a printed sensor to monitor bone turnover. The absence of load bearing forces experienced in microgravity causes a reduction of overall bone mass and results in the development of space osteopenia/osteoporosis.(1,2) Our approach to identify space osteopenia/osteoporosis is to monitor the change in bone mass indirectly through an excreted biomarker of bone remodeling, amino-terminal collagen crosslinks (NTX). Antibodies specific to NTX are added to the sensor’s electrode ink and applied during the manufacturing process. NTX is measured from a urine sample by changes in voltammetry and electrochemical impedance as it binds to the antibody modified electrode surface. The measurement is rapid, quantitative and requires only small handheld electronics to perform the measurement. By this process, ground and flight physicians will receive frequent and real-time insight into the development of space osteopenia/osteoporosis to guide appropriate countermeasures. REFERENCES [1] Nabavi, N. et al (2011) Bone 49, 965-974. [2] Tamma, R. et al (2009) FASEB J 23, 2549-2554.

in-space manufacturing↗

Laser-induced graphene gas sensors for environmental monitoring

Artemesia tridentatais a foundational plant taxon in western North America and an important medicinal plant threatened by climate change. Low-cost fabrication of sensors is critical for developing large-area sensor networks for understanding and monitoring a range of environmental conditions. However, the availability of materials and manufacturing processes is still in the early stages, limiting the capacity to develop cost-effective sensors at a large scale. In this study, we demonstrate the fabrication of low-cost flexible sensors using laser-induced graphene (LIG); a graphitic material synthesized using a 450-nm wavelength bench top laser patterned onto polyimide substrates. We demonstrate the effect of the intensity and focus of the incident beam on the morphology and electrical properties of the synthesized material. Raman analyses of the synthesized LIG show a defect-rich graphene with a crystallite size in the tens of nanometers. This shows that the high level of disorder within the LIG structure, along with the porous nature of the material provide a good surface for gas adsorption. The initial characterization of the material has shown an analyte response represented by a change in resistance of up to 5% in the presence of volatile organic compounds (VOCs) that are emitted and detected byArtemisiaspecies. Bend testing up to 100 cycles provides evidence that these sensors will remain resilient when deployed across the landscapes to assess VOC signaling in plant communities. The versatile low-cost laser writing technique highlights the promise of low-cost and scalable fabrication of LIG sensors for gas sensor monitoring.

Chemistry↗

Low-Temperature Plasma-Based Metrology of Lithium-Ion Battery Electrode Materials (CRADA Final Report)

As part of the Cyclotron Road program, SirenOpt Inc. evaluated its low-temperature plasma-based metrology sensor prototype for measuring multiple critical properties of lithium-ion battery electrode materials in parallel and in real-time. Cost-effective, minimal-waste manufacturing of high-performance battery electrode materials will be vital for achieving society’s net-zero carbon emission goals. Because existing electrode metrology sensors cannot operate within most sections of manufacturing lines, manufacturers often complete hundreds of processing steps before they can test their products and detect problems. When manufacturers perform these offline tests, they typically only test a small portion of the manufactured products. Current electrode manufacturing thus often yields many low-quality products, or off-spec products that must be thrown away all together. For example, at least 6% of the total lithium-ion battery manufacturing cost (i.e., over $250 million/year for the average gigafactory) is devoted to processing defective electrodes that are not scrapped until performance tests are failed during late-stage quality control checks. Electrode variability also leads manufacturers to build extra cells into battery packs to reduce the risk of poor performance. For example, many electric vehicle (EV) manufacturers include up to 10% more cells than needed, which substantially increases the cost and weight of the final EV product. The SirenOpt sensor can potentially enable early detection of poorly manufactured electrodes and allow them to be removed earlier from manufacturing lines, which can save battery manufacturers (hundreds of) millions of dollars per year. The sensor can further be used to improve product quality by accelerating R&D and process optimization, improving quality control, and enabling real-time process control. Overall, a real-time, in-situ metrology strategy can create unprecedented opportunities for implementation of smart manufacturing practices and advanced quality and process control solutions to realize higher battery electrode throughput and performance.

25 ENERGY STORAGE↗

Using AVIRIS Data to Map and Characterize Subaerially and Subaqueously Erupted BasalticVolcanic Tephras: The Challenge of Mapping Low-Albedo Materials

Increases in the signal-to-noise ratio (SNR) in AVIRIS has enabled the mapping and characterization of low albedo materials. Low albedo materials of interest include certain soils, man-made materials (asphalt, certain building materials, tires, etc.), and basaltic lava flows and ashes. Early in its history, the response of the AVIRIS sensor was not sensitive enough so that these low albedo materials could be reliably mapped. However, as indicated by Green and Pavri (2002) the noise equivalent delta radiance (NEdL) of AVIRIS in the 2001 flight season was below 0.010 in all but the shortest wavelength channels. This is approximately a ten-fold improvement from the 1989 flight season when NEdL was closer to 0.1 (Green et al., 1990). In the current investigation, AVIRIS data from the 2002 flight season collected over the Pavant Butte tuff cone, Tabernacle Hill tuff ring, and an associated lava flow in the Black Rock Desert of west central Utah were examined to determine how well these generally low albedo volcanic lavas and tephras could be discriminated from background materials. The Pavant Butte tuff cone was examined by the author in an earlier study with a 1989 AVIRIS dataset (Farrand and Singer,

Farrand, William H.↗

Process and control systems for composites manufacturing

A precise control of composite material processing would not only improve part quality, but it would also directly reduce the overall manufacturing cost. The development and incorporation of sensors will help to generate real-time information for material processing relationships and equipment characteristics. In the present work, the thermocouple, pressure transducer, and dielectrometer technologies were investigated. The monitoring sensors were integrated with the computerized control system in three non-autoclave fabrication techniques: hot-press, self contained tool (self heating and pressurizing), and pressure vessel). The sensors were implemented in the parts and tools.

Tsiang, T. H.↗

A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation

A system for wirelessly measuring the volume of fluid in tanks at non-horizontal orientation is predicated upon two technologies developed at Langley Research Center. The first is a magnetic field response recorder that powers and interrogates magnetic field response sensors [ Magnetic Field Response Measurement Acquisition System, (LAR-16908), NASA Tech Briefs, Vol. 30, No. 6 (June 2006), page 28]. Magnetic field response sensors are a class of sensors that are powered via oscillating magnetic fields and when electrically active respond with their own magnetic fields whose attributes are dependent upon the magnitude of the physical quantity being measured. The response recorder facilitates the use of the second technology, which is a magnetic field response fluid-level sensor ["Wireless Fluid- Level Sensors for Harsh Environments," (LAR-17155), NASA Tech Briefs, Vol. 33, No. 4 (April 2009), page 30]. The method for powering and interrogating the sensors allows them to be completely encased in materials (Fig. 1) that are chemically resilient to the fluid being measured, thereby facilitating measurement of substances (e.g., acids, petroleum, cryogenic, caustic, and the like) that would normally destroy electronic circuitry. When the sensors are encapsulated, no fluid (or fluid vapor) is exposed to any electrical component of the measurement system. There is no direct electrical line from the vehicle or plant power into a fuel container. The means of interrogating and powering the sensors can be completely physically and electrically isolated from the fuel and vapors by placing the sensor on the other side of an electrically non-conductive bulkhead (Fig. 2). These features prevent the interrogation system and its electrical components from becoming an ignition source.

Woodward, Stanley E.↗

Correlating structural changes in thermoresponsive hydrogels to the optical response of embedded plasmonic nanoparticles

Stimuli-responsive microgels, composed of small beads with soft, deformable polymer networks swollen through a combination of synthetic control over the polymer and its interaction with water, form a versatile platform for development of multifunctional and biocompatible sensors. The interfacial structural variation of such materials at a nanometer length scale is essential to their function, but not yet fully comprehended. Here, we take advantage of the plasmonic response of a gold nanorod embedded in a thermoresponsive microgel (AuNR@PNIPMAm) to monitor structural changes in the hydrogel directly near the nanorod surface. By direct comparison of the plasmon response against measurements of the hydrogel structure from dynamic light scattering and nuclear magnetic resonance, we find that the microgel shell of batch-polymerized AuNR@PNIPMAm exhibits a heterogeneous volume phase transition reflected by different onset temperatures for changes in the hydrodyanmic radius (R H ) and plasmon resonance, respectively. The new approach of contrasting plasmonic response (a measure of local surface hydrogel structure) with R H and relaxation times paves a new path to gain valuable insight for the design of plasmonic sensors based on stimuli-responsive hydrogels.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unconventional Photocurrents from Surface Fermi Arcs in Topological Chiral Semimetals

The nonlinear optical responses from topological semimetals are crucial in both understanding the fundamental properties of quantum materials and designing next-generation light sensors or solar cells. However, previous work focused on the optical effects from bulk states only, disregarding the responses from topological surface states. Here, we propose a new surface-only photocurrent response from chiral Fermi arcs. Using the ideal topological chiral semimetal RhSi as a representative, we quantitatively compute the photogalvanic currents from Fermi arcs on different surfaces. By rigorous crystal symmetry analysis, we demonstrate that Fermi arc photogalvanic currents can be perpendicular to the bulk injection currents regardless of the choice of materials surface. We then generalize this finding to other cubic chiral space groups and predict material candidates. Our theory reveals a powerful notion where common crystalline symmetry can be used to completely disentangle bulk and surface optical responses in many conducting material families.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enabling novel space and terrestrial applications using transducing materials at JPL

Transducing materials are being used in many aspects of our daily life serving as actuators, sensors, displays, communications and other components of commercial mechanisms. At JPL, such materials are being used to enable novel space and terrestrial applications. This effort involves mostly the use of piezoelectric, electroactive polymers (EAP), and shape memory alloys (SMA). The piezoelectric based devices and mechanisms that were developed include ultrasonic motors, piezopump, ultrasonic/sonic drilledcorer (USDC), and ferrosource. Further, the electroactive polymers were used to demonstrate a gripper, wiper, lifter and haptic interfaces. The research and develop tasks consists of analytical modeling, experimental corroboration, material characterization as well as devices and mechanisms design, construction and demonstration.

electroactive↗

Semiselective Optoelectronic Sensors for Monitoring Microbes

Sensor systems are under development for use in real-time detection and quantitation of microbes in water without need for sampling. These systems include arrays of optical sensors; miniature, portable electronic data-acquisition circuits; and optoelectronic interfaces between the sensor arrays and data-acquisition circuits. These systems are intended for original use in long-term, inline monitoring of waterborne micro-organisms in water-reclamation systems aboard future spacecraft. They could also be adapted to similar terrestrial uses with respect to municipal water supplies, stored drinking water, and swimming water; for detecting low-level biological contamination in biotechnological, semiconductor, and pharmaceutical process streams; and in verifying the safety of foods and beverages. In addition, they could be adapted to monitoring of airborne microbes and of surfaces (e.g., to detect and/or quantitate biofilms). The designs of the sensors in these systems are based partly on those of sensors developed previously for monitoring airborne biological materials. The designs exploit molecular- recognition and fluorescence-spectroscopy techniques, such that in the presence of micro-organisms of interest, fluorescence signals change and the changes can be measured. These systems are characterized as semiselective because they respond to classes of micro-organisms and can be used to discriminate among the classes. This semiselectivity is a major aspect of the design: It is important to distinguish between (1) the principle of detection and quantitation of classes of micro-organisms by use of these sensors and (2) the principle of detection and quantitation of individual microbiological species by means of prior immuno-diagnostic and/or molecular-biology techniques. Detection of classes (in contradistinction to species) is particularly valuable when the exact nature of a contaminant is unknown.

Tabacco, Mary Beth↗

Liquid Bismuth Propellant Management System for the Very High Specific Impulse Thruster with Anode Layer

Two prototype bismuth propellant feed systems were constructed and operated in conjunction with a propellant vaporizer. One system provided bismuth to a vaporizer using gas pressurization but did not include a means to measure the flow rate. The second system incorporated an electromagnetic pump to provide fine control of the hydrostatic pressure and a new type of in-line flow sensor that was developed for accurate, real-time measurement of the mass flow rate. High-temperature material compatibility was a driving design requirement for the pump and flow sensor, leading to the selection of Macor for the main body of both components. Posttest inspections of both components revealed no degradation of the material. The gas pressurization system demonstrated continuous pressure control over a range from zero to 200 torr. In separate proof-of-concept experiments, the electromagnetic pump produced a linear pressure rise as a function of current that compared favorably with theoretical pump pressure predictions, producing a pressure rise of 10 kPa at 30 A. Preliminary flow sensor operation indicated a bismuth flow rate of 6 mg/s with an uncertainty of plus or minus 6%. An electronics suite containing a real-time controller was successfully used to control the entire system, simultaneously monitoring all power supplies and performing data acquisition duties.

Polzin, K. A.↗

Nanomanipulation and Lithography for Carbon Nanotube Based Nondestructive Evaluation Sensor Development

Carbon nanotubes (CNTs) offer great potential for advanced sensor development due to the unique electronic transport properties of the material. However, a significant obstacle to the realization of practical CNT devices is the formation of reliable and reproducible CNT to metallic contacts. In this work, scanning probe techniques are explored for both fabrication of metallic junctions and positioning of singlewalled CNTs across these junctions. The use of a haptic force feedback interface to a scanning probe microscope is used to enable movement of nanotubes over micron length scales with nanometer precision. In this case, imaging of the surface is performed with light or intermittent contact to the surface. Increased tip-to-sample interaction forces are then applied to either create junctions or position CNTs. The effect of functionalization of substrate surfaces on the movement and tribology of the materials is also studied. The application of these techniques to the fabrication of CNT-based sensors for nondestructive evaluation applications is discussed.

Wincheski, Buzz↗

Cryogenic Chamber for Servo-Hydraulic Materials Testing

A compact cryogenic test chamber can be cooled to approximately 5 to 6 Kelvin for materials testing. The system includes a temperature controller and multiple sensors to measure specimen temperature at different locations. The testing chamber provides a fast and easy method to perform materials testing at lower than liquid nitrogen temperature (77 K). The purpose of the chamber is to cool a composite lap shear specimen to approximately 20 K so that tensile test force and displacement data may be acquired at this cryogenic temperature range.

Francis, John J.↗

On-Demand Manufacturing of Electronics

The On-Demand Manufacturing of Electronics (ODME) project develops materials, processes, and device designs to enable electronics, sensors, and semiconductors to be produced in microgravity environments. The demonstration of these technologies provides a pathway for space-based manufacturing of circuits, wearables, energy storage devices, and other electronics. This has facilitated the terrestrial production of devices including a wide range of sensors, printed batteries, and circuits that are additively manufactured using techniques available on the Advanced Toolplate System (ATS). Recent parabolic flight campaigns conducted with the ATS suggest that direct ink write (DIW) technology is suitable for depositing functional material inks in reduced gravity environments. The development of the Advanced Toolplate system also includes several other new tools, including miniaturized versions of the direct write head, fused filament fabrication head, micro-mill, component pick & place head, and two newly developed deposition technologies, the Electrohydrodynamic (EHD) inkjet head (for semiconductors), and the Electrodeposition head (for high performance circuits). These experiments are designed to compare processing and material behavior in zero gravity versus ground-based data for validation of microgravity advantages and de-risking of future orbital demonstrations of these technologies. The ability to conduct experiments in microgravity is a pivotal step in enabling electronic manufacturing technology in space for both terrestrial and deep space applications.

Cadre Francis↗

Advanced ACTPol Multichroic Polarimeter Array Fabrication Process for 150 mm Wafers

Advanced ACTPol (AdvACT) is a third-generation cosmic microwave background receiver to be deployed in 2016 on the Atacama Cosmology Telescope (ACT). Spanning five frequency bands from 25 to 280 GHz and having just over 5600 transition-edge sensor (TES) bolometers, this receiver will exhibit increased sensitivity and mapping speed compared to previously fielded ACT instruments. This paper presents the fabrication processes developed by NIST to scale to large arrays of feedhorn-coupled multichroic AlMn-based TES polarimeters on 150-mm diameter wafers. In addition to describing the streamlined fabrication process which enables high yields of densely packed detectors across larger wafers, we report the details of process improvements for sensor (AlMn) and insulator (SiN(sub x)) materials and microwave structures, and the resulting performance improvements.

Atacama Cosmology Telescope(ACT)↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments

The goal of our activities in FY24 was to enable advanced materials accountancy for molten salt reactors (MSRs) through the development and optimization of robust flow-enhanced electrochemical sensors (FEES) using a safeguards-focused sensor testing platform called the modular flow instrumentation testbed (MFIT). Flow-enhanced electrochemical sensors are a type of electroanalytical sensor that have been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. This year, the FEES technical readiness was increased by (1) demonstrating the use of optimized sensor techniques to achieve measurements in very high-concentration MSR-relevant salts, (2) leveraging new multimodal sensors and automation approaches to reduce measurement uncertainties, and (3) fabricating and deploying sensors to industrial partners to improve their ability to make measurements in challenging environments. Additionally, we also ran the sensors during complex system operations involving combined flow and purification activities to demonstrate safeguards-relevant measurements during online processing for MSRs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗