Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Descriptive Analytics-Based Anomaly Detection for Cybersecure Load Forecasting

As power delivery systems evolve and become increasingly reliant on accurate forecasts, they will be more and more vulnerable to cybersecurity issues. A coordinated data attack by sophisticated adversaries can render existing data corrupt or outlier detection methods ineffective. This would have a very negative impact on operational decisions. The focus of this paper is to develop descriptive analytics-based methods for anomaly detection to protect the load forecasting process against cyberattacks to essential data. We propose an integrated solution (IS) and a hybrid implementation of IS (HIIS) that can detect and mitigate cyberattack induced long sequence anomalies. HIIS is also capable of improving true positive rates and reducing false positive rates significantly comparing with IS. The proposed HIIS can serve as an online cybersecure load forecasting scheme.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Speed to Power: Solutions for Accelerating Large Load Connections

Rapid growth in demand from data centers and other large loads is creating a range of new challenges for electricity planners, investors, system operators, and regulators, leading to bottlenecks that have slowed connection of large loads to the electric grid. In response, innovative solutions for accelerating large load connections are beginning to emerge across the U.S. Drawing on an extensive document and literature review, this report identifies more than 40 potential solutions for accelerating large load connections, organized into five functional areas: load forecasting, interconnection, resource planning and procurement, markets and operations, and cost allocation and ratemaking. The five functional areas provide a framework for organizing challenges and solutions to large load connection bottlenecks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ERDA/NASA 100 kilowatt mod-o wind turbine operations and performance

The ERDA/NASA 100 kW Mod-0 wind turbine is operating at the NASA Plum Brook Station near Sandusky, Ohio. The operation of the wind turbine has been fully demonstrated and includes start-up, synchronization to the utility network, blade pitch control for control of power and speed, and shut-down. Also, fully automatic operation has been demonstrated by use of a remote control panel, 50 miles from the site, similar to what a utility dispatcher might use. The operation systems and experience with the wind turbine loads, electrical power and aerodynamic performance obtained from testing are described.

Thomas, R. L.↗

Distribution Feeder-Scale Fast Frequency Response via Optimal Coordination of Net-load Resources Part II: Large-Scale Demonstration

This work is the second of a two-part series in which we develop and experimentally demonstrate a hierarchical control solution for optimally coordinating thousands of deferrable loads and distributed energy resources (DERs) to provide fast frequency response (FFR) from an entire distribution feeder. In Part I, we developed and proved practical algorithms for fast, cost-based optimal dispatch and for determining the optimal amount of headroom to operate solar inverters with to support FFR dispatch while minimizing opportunity cost. Simulation results in Part I demonstrated the advantages of the hierarchical dispatch approach in being able to maintain fast solution times needed for FFR even when the problem size increases. In Part II, we implement the algorithms developed in Part I in a novel, large-scale power hardware-in-the-loop experiment including embedded controllers and more than 100 powered appliance loads and DER connected to a simulated real-world distribution system with more than 10,000 controlled devices. Experimental results from multiple scenarios confirm that the optimal FFR dispatch approach scales well and can optimally coordinate more than 10,000 net-load resources across a distribution network while achieving hardware response times within 500 ms, which is not possible using state-of-the-art optimal coordination approaches.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A multi-scale time-series dataset with benchmark for machine learning in decarbonized energy grids

The electric grid is a key enabling infrastructure for the ambitious transition towards carbon neutrality as we grapple with climate change. With deepening penetration of renewable resources, the reliable operation of the electric grid becomes increasingly challenging. In this paper, we present PSML, a first-of-its-kind open-access multi-scale time-series dataset, to aid in the development of data-driven machine learning (ML)-based approaches towards reliable operation of future electric grids. The dataset is synthesized from a joint transmission and distribution electric grid to capture the increasingly important interactions and uncertainties of the grid dynamics, containing power, voltage and current measurements over multiple spatio-temporal scales. Using PSML, we provide state-of-the-art ML benchmarks on three challenging use cases of critical importance to achieve: (i) early detection, accurate classification and localization of dynamic disturbances; (ii) robust hierarchical forecasting of load and renewable energy; and (iii) realistic synthetic generation of physical-law-constrained measurements. We envision that this dataset will provide use-inspired ML research in safety-critical systems, while simultaneously enabling ML researchers to contribute towards decarbonization of energy sectors.

54 ENVIRONMENTAL SCIENCES↗

Electrical power generation from moderate-temperature radiative thermal sources

Moderate-temperature thermal sources (100° to 400°C) which radiate waste heat are often the by-product of mechanical work, chemical or nuclear reactions, or information processing. We demonstrate conversion of thermal radiation into electrical power using a bipolar grating-coupled complementary metal-oxide-silicon (CMOS) tunnel diode. A two-step photon-assisted tunneling charge pumping mechanism results in separation of charge carriers in pn-junction wells leading to a large open-circuit voltage developed across a load. Electrical power generation from a broadband blackbody thermal source has been experimentally demonstrated with converted power densities of 27 to 61 microwatts per square centimeter for thermal sources between 250° and 400°C. Scalable, efficient conversion of radiated waste heat into electrical power can be used to reduce energy consumption or to power electronics and sensors.

30 DIRECT ENERGY CONVERSION↗

Assessing Dynamic Behaviors in Converter- Dominated Power Systems via RMS and EMT Simulations: A Study of Hawaii’s NELHA Microgrid

The transition from conventional power systems to converter-based microgrids has significantly advanced sustainability, clean energy integration, and operational reliability. However, this paradigm shift introduces operational challenges due to the intermittent nature of renewable energy sources and the non-linear characteristics of power electronic loads, inducing voltage fluctuations and harmonic distortions that complicate voltage and frequency regulation. Accurate dynamic modeling is hypothesized to be critical for capturing such effects, enabling reliable simulation and control strategy development. This study introduces an innovative dynamic modeling framework for a real-world converter-based microgrid, utilizing both root mean square (RMS) and electromagnetic transient (EMT) simulation methods. The microgrid was modeled in DIgSILENT PowerFactory, with simulations calibrated against high-resolution field measurements from SEL-735 power quality meters. Results show that RMS simulations effectively characterize steady-state dynamics, while EMT simulations are essential for capturing high-frequency transients and non-linear effects from photovoltaic inverters and variable frequency drives (VFDs). This complementary approach provides a comprehensive understanding of microgrid behavior, providing critical insights for improving simulation accuracy, advancing protection schemes, and improving resilience in future low-inertia power networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic simulation and load-following control of an integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture

Load-following control of future integrated gasification combined cycle (IGCC) plants with pre-combustion CO{sub 2} capture is expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. To study control performance during load following, a plant-wide dynamic simulation of a coal-fed IGCC plant with CO{sub 2} capture has been developed. The slurry-fed gasifier is a single-stage, downward-fired, oxygen-blown, entrained-flow type with a radiant syngas cooler (RSC). The syngas from the outlet of the RSC goes to a scrubber followed by a two-stage sour shift process with inter-stage cooling. The acid gas removal (AGR) process is a dual-stage physical solvent-based process for selective removal of H{sub 2}S in the first stage and CO{sub 2} in the second stage. Sulfur is recovered using a Claus unit with tail gas recycle to the AGR. The recovered CO{sub 2} is compressed by a split-shaft multistage compressor and sent for sequestration after being treated in an absorber with triethylene glycol for dehydration. The clean syngas is sent to two advanced “F”-class gas turbines (GTs) partially integrated with an elevated-pressure air separation unit. A subcritical steam cycle is used for heat recovery steam generation. A treatment unit for the sour water strips off the acid gases for utilization in the Claus unit. The steady-state model developed in Aspen Plus® is converted to an Aspen Plus Dynamics® simulation and integrated with MATLAB® for control studies. The results from the plant-wide dynamic model are compared qualitatively with the data from a commercial plant having different configuration, operating condition, and feed quality than what has been considered in this work. For load-following control, the GT-lead with gasifier-follow control strategy is considered. A modified proportional–integral–derivative (PID) control is considered for the syngas pressure control. For maintaining the desired CO{sub 2} capture rate while load-following, a linear model predictive controller (LMPC) is implemented in MATLAB®. A combined process and disturbance model is identified by considering a number of model forms and choosing the final model based on an information-theoretic criterion. The performance of the LMPC is found to be superior to the conventional PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

01 COAL, LIGNITE, AND PEAT↗

Development of an Adaptive Droop Control Method for Interconnected Lunar DC Microgrids Using Power Hardware-in-the-Loop

NASA’s Artemis Program outlines the need for a habitat capable of sustaining human life as well as mining and producing raw materials on the lunar surface. This mission is viewed as a means towards deeper space exploration, with plans for reaching Mars and beyond. Human presence on the moon is not possible without the ability to generate and distribute energy, namely electricity, through a network of energy sources, loads, and power converters called a microgrid. Multiple microgrids can be deployed on the moon based on location and need. Separate microgrids will require interconnection to increase resiliency and reliability given the mission’s high criticality. A method for adaptive control over power converters connecting two dc microgrids is proposed. A simulation is modeled after the lunar power system with two approaches to power converter droop control, allowing for a more flexible and adaptive microgrid architecture. Further experiments are conducted using the control methods in a power hardware-in-the-loop test environment to study the performance of hardware converter control used in this application.

dc microgrid↗

Distributed Automatic Load-Frequency Control with Optimality in Power Systems: Preprint

With increasing penetrations of renewable energy resources, power systems face new challenges in balancing supply and demand and maintaining nominal frequency. This paper studies load control to handle these challenges. In particular, a fully distributed automatic load control algorithm, which needs only local measurement and local communications, is proposed. We prove that the control algorithm globally converges to an optimal operating point that minimizes the total disutility of users, restores the nominal frequency and the scheduled tie-line power flows, and respects the thermal constraints of transmission lines. We also show that the convergence holds even when inaccurate system parameters are used in the control algorithm. Last, the effectiveness, optimality, and robustness of the proposed algorithm are demonstrated via numerical simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermion: Verification of a thermionic heat pipe in microgravity

The Idaho National Engineering Laboratory (INEL) is conducting intensive research in the design and development of a small excore heat-pipe-thermionic space nuclear reactor power system (SEHPTR). The SEHPTR spacecraft will be able to supply 40 kW of power in any given orbit. The key components in this reactor are the thermionic heat pipes. The heat pipes have two major functions: (1) to convert heat energy into electrical energy, and (2) to radiate the excess heat to space. Thermionic power conversion is the process of converting heat energy into electrical energy with no moving parts. Heat is applied to the cathode surface. This heat will boil off electrons that will jump across the gap to the cooler surface of the anode, which will cause a potential difference between the two plates and induce a current through the load. Thermionic power conversion is incorporated as part of the heat pipe. The heat pipe, which is being developed by Thermacore Inc., is actually two heat pipes. It uses a radial heat pipe, called the emitter, and an axial heat pipe collector. The emitter heat pipe will pass the heat from the nuclear core to the cathode surface. The collector heat pipe keeps the anode surface cooler by transferring the heat from the anode surface and radiating it to space.

Source record↗

Microgrid for Lunar Surface Power

Sustained lunar surface operations will require access to continuous and highly reliable power to support mission needs and an ability to evolve and grow over time (years). The first initial loads that arrive on the lunar surface will contain their own dedicated power sources. Over time, as the lunar surface operations and power demands grow, these individual power loads will require more power than can be generated with any single power device. This demand drives the need for inter-connecting loads and power devices to share power between them, resulting in a micro-grid. One advantage of developing a lunar surface micro-grid is that it will allow lunar surface operations to resemble electrical utility operations on Earth; it allows power to be generated where it is convenient and allows power to be consumed where it is convenient and required. The micro-grid concept also provides another benefit of affording the ability to increase overall system reliability by integrating dissimilar power generation and energy storage devices together, for example modifying the power generation strategy to include both solar arrays and nuclear. This talk provides an overview of NASA’s interest in developing a lunar microgrid and provides areas where external entities can play a role in developing futuristic power needs.

Jeffrey Csank↗

Artificial Intelligence Techniques in Smart Grid: A Survey

The smart grid is enabling the collection of massive amounts of high-dimensional and multi-type data about the electric power grid operations, by integrating advanced metering infrastructure, control technologies, and communication technologies. However, the traditional modeling, optimization, and control technologies have many limitations in processing the data; thus, the applications of artificial intelligence (AI) techniques in the smart grid are becoming more apparent. This survey presents a structured review of the existing research into some common AI techniques applied to load forecasting, power grid stability assessment, faults detection, and security problems in the smart grid and power systems. It also provides further research challenges for applying AI technologies to realize truly smart grid systems. Finally, this survey presents opportunities of applying AI to smart grid problems. The paper concludes that the applications of AI techniques can enhance and improve the reliability and resilience of smart grid systems.

energy systems↗

Power Management Solution for Growing Loads at Airport Rental Facilities

Growing electrical loads across airport facilities could expand beyond local grid capacities. Coordinating flexible loads with generation and storage assets can reduce coincident peaks, mitigate costly upgrades, and reduce electricity costs. This report outlines how The Athena Team has developed a suite of tools, resources, and solutions to leverage load flexibility with energy assets to harness this value potential.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Research on stability and uniformity of multi-wavelength Brillouin-erbium fiber laser based on FWM

In this paper, we experimentally and theoretically investigate the stability and uniformity of multi-wavelength Brillouin-erbium fiber laser based on four-wave mixing (FWM). Multi-wavelength generation is limited by cross-gain saturation between different wavelengths from homogeneous broadening of erbium-doped fiber. Modeling coupled-mode equation for FWM and analyzing the influence of FWM on multi-wavelength generation. 16 orders Brillouin Stokes (BS) waves with a wavelength spacing of 0.084 nm are obtained experimentally within a 3 dB bandwidth by the FWM effect in a 100 m highly nonlinear fiber (HNLF), power distribution of each laser is uniform and peak power fluctuation is less than 1.184 dB within a 10 dB bandwidth, the outputs exhibit good time stability and uniformity. Compared with the same configuration, the laser without HNLF has only 9 orders stable BS waves within 3 dB bandwidth, and high-order Stokes wave shows significant waveform jitter and power fluctuation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Cost of Transmission for Wind Energy: A Review of Transmission Planning Studies

The rapid development of wind power that the United States has experienced over the last several years has been coupled with a growing concern that wind development will require substantial additions to the nation's transmission infrastructure. Transmission is particularly important for wind power due to the locational dependence of wind resources, the relatively low capacity factor of wind plants, and the mismatch between the short lead time to build a new wind project and the longer lead time often needed to plan, permit, and construct transmission. It is clear that institutional issues related to transmission planning, siting, and cost allocation will pose major obstacles to accelerated wind power deployment, but also of concern is the potential cost of this infrastructure build out. Simply put, how much extra cost will society bear to deliver wind power to load centers? Without an answer to this question, there can be no consensus on whether or not the cost of developing transmission for wind will be a major barrier to further wind deployment, or whether the institutional barriers to transmission expansion are likely to be of more immediate concern. In this report, we review a sample of 40 detailed transmission studies that have included wind power. These studies cover a broad geographic area, and were completed from 2001-2008. Our primary goal in reviewing these studies is to develop a better understanding of the transmission costs needed to access growing quantities of wind generation. A secondary goal is to gain a better appreciation of the differences in transmission planning approaches in order to identify those methodologies that seem most able to estimate the incremental transmission costs associated with wind development. Finally, we hope that the resulting dataset and discussion might be used to inform the assumptions, methods, and results of higher-level assessment models that are sometimes used to estimate the cost of wind deployment (e.g. NEMS and WinDS). The authors and general location of the 40 detailed transmission studies included in our review are illustrated in Figure ES-1. As discussed in the body of the report, these studies vary considerably in scope, authorship, objectives, methodology, and tools. Though we recognize this diversity and are cognizant that comparisons among these studies are therefore somewhat inappropriate, we nonetheless emphasize such simple comparisons in this report. We do so in order to improve our understanding of the range of transmission costs needed to access greater quantities of wind, and to highlight some of the drivers of those costs. In so doing, we gloss over many important details and differences among the studies in our sample. In emphasizing simple comparisons, our analysis focuses primarily on the unit cost of transmission implied by each of the studies. The unit cost of transmission for wind in $/kW terms on a capacity-weighted basis is estimated by simply dividing the total transmission cost in a study by the total amount of incremental generation capacity (wind and non-wind) modeled in that study. In so doing, this metric assumes that within any individual study all incremental generation capacity imposes transmission costs in proportion to its nameplate capacity rating. The limitations to this approach are described in some detail in the body of the report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fuel cell powerplant operation in Apollo spacecraft.

Primary electrical power for loads in the Apollo Command and Service Modules is furnished by a system of three fuel cell powerplants. The powerplants convert cryogenic hydrogen and oxygen into direct current. Water formed in the fuel cell reactions is supplied to the spacecraft for crew use. Waste heat is rejected through a coolant loop to a spacecraft radiator. The ability of the fuel cell to meet its voltage-power requirements and to control its own operating temperature under the environmental extremes of launch, ascent, earth orbit, translunar flight, and lunar orbit was demonstrated on successively more difficult missions leading up to the first lunar landing.

Ching, A. C.↗