Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Java Software Extensibility Library

The Java Software Extensibility Library provides tools that help Java software developers produce flexible and extensible Java applications. The major components include a Plugin Library and a Polymorphic Map data structure. The Plugin Library provides developers with a Plugin Registry and a standard pattern for designing, versioning, registering, retrieving, and annotating plugins. It also enables advanced capabilities such as loading plugins at runtime, and creating/loading encrypted plugin packages. The Polymorphic Map data structure facilitates the storage and retrieval of objects of varying types within a single data structure; while maintaining type safety. The library also provides a standard design pattern for producing application-specific "Domain Maps" and "Closed Domain Maps".SAND2020-3816 M Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Fleschute, Christopher↗

Regional Medium-Term Hourly Electricity Demand Forecasting Based on LSTM

This paper aims to forecast high-resolution (hourly) aggregated load for a certain region in the medium term (a few days to over a year). One region is defined as some places with similar climate characteristics because the climate influences people's daily lifestyles and hence the electric usage. We decompose the electric usage records into two parts: base load and seasonal load. Considering both temperature and time factors, different deep-learning methods are adopted to characterize them. The first goal of our approach is to predict the peak load which is critical for power system planning. Furthermore, our proposed forecast method can provide the depiction of the hourly load profile to provide customized load curves for high-level real-time applications. The proposed method is tested on real-world historical data collected by CAISO, BPA, and PACW. The experimental results show that trained by three years of data, our method could reduce the prediction error for a one-year lead hourly load below $5\%$ MAPE, and predict the occurrence of the peak load for next year in CAISO with an error within three days. Furthermore, as a byproduct, an interesting observation on the impact of COVID-19 on human life was made and discussed based on these case studies.

deep learning↗

Regional Medium-Term Hourly Electricity Demand Forecasting Based on LSTM: Preprint

This paper aims to forecast high-resolution (hourly) aggregated load for a certain region in the medium term (a few days to over a year). One region is defined as some places with similar climate characteristics because the climate influences people's daily lifestyles and hence the electric usage. We decompose the electric usage records into two parts: base load and seasonal load. Considering both temperature and time factors, different deep-learning methods are adopted to characterize them. The first goal of our approach is to predict the peak load which is critical for power system planning. Furthermore, our proposed forecast method can provide the depiction of the hourly load profile to provide customized load curves for high-level real-time applications. The proposed method is tested on real-world historical data collected by CAISO, BPA, and PACW. The experimental results show that trained by three years of data, our method could reduce the prediction error for a one-year lead hourly load below 5% MAPE, and predict the occurrence of the peak load for next year in CAISO with an error within three days. Furthermore, as a byproduct, an interesting observation on the impact of COVID-19 on human life was made and discussed based on these case studies.

deep learning↗

Comparative Analysis of ML Techniques for Data-Driven Anomaly Detection, Classification and Localization in Distribution System

High penetration of Distributed Energy Resources (DERs), fundamental load behavior changes, controllable loads, and significant increase in Electrical Vehicles (EVs) lead to complex dynamic behavior of the electric distribution system. Increasing number of components also means more measurements, more data and more data anomalies. Detecting, classifying and localizing these anomalies are important for situational awareness, and at the same time, very challenging given increasing complexity of the system. Highly accurate and high-resolution analytical techniques are needed to support anomaly detection, classification and localization (AD-C-L) for monitoring, root cause analysis and decision making. This paper provides comprehensive review and analysis of the existing spatio-temporal AD-C-L techniques within the distribution system. Challenges for specific problems in AD-C- L have been also discussed in this paper. Existing AD-C- L techniques have been categorized and synthesized for specific merits and limitations of multiple Machine Learning (ML) methodologies using common developed metrics of performance. The comparative analysis is summarized and presented with the open research challenges and path forward for future research needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of sodium loading on Pt/ZrO 2 during ethanol steam reforming

Ethanol steam reforming (ESR) was investigated on unpromoted and several sodium promoted Pt/ZrO 2 catalysts. From DRIFTS experiments, the following steps during ESR were inferred: dissociation of ethanol to produce ethoxy species; oxidative dehydrogenation of ethoxy species to acetate; and acetate decomposition. Acetate decomposition depends on the catalyst formulation. Decarboxylation is the most favored route at high sodium loading (2.5 and 5 wt.%); acetate decomposes in the forward direction to CH 4 and a carbonate, which further decomposes to CO 2 . In contrast, decarbonylation is prevalent for the unpromoted catalyst or catalysts having low sodium loading. Furthermore, acetate likely decomposes to CH 3 OH and CO. Adsorbed methanol may undergo further steam reforming by oxidative dehydrogenation to formate species, which decarbonylates via reverse decomposition to CO and H 2 O. Temperature programmed desorption/reaction and activity data confirmed that alkali promotion, especially at 1.8 %Na and higher loading, facilitates the forward acetate decomposition step, favoring decarboxylation over decarbonylation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HEPnOS: a Specialized Data Service for High Energy Physics Analysis

In this paper, we present HEPnOS, a distributed data service for managing data produced by high-energy physics (HEP) experiments. Using HEPnOS, HEP applications can use HPC resources more effciently than traditional fle-based applications. The fle-based model leads to a rigid, chunk-based allocation of computational resources and limits the number of cores that can be used concurrently by an HEP application. The fundamental problem is that organizing domain-specifc data into fles inadvertently introduces a single, artifcial, confated tuning parameter that puts key optimization goals into confict: larger fle sizes reduce metadata overhead and thus improve I/O effciency, but smaller fle sizes provide more opportunity for workfow parallelism and load balancing. In this work, we introduce a domain-specifc data service that decouples that constraint so that data can be accessed and processed in its natural granularity while still maintaining I/O effciency. By removing the constraints introduced by fle handling we are able to obtain better scaling and make effcient use of more cores for processing a fxed-sized data sample. We demonstrate the improved scalability by using an application developed in the fle-based paradigm and comparing it to a version modifed to use HEPnOS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Robust Medium-Voltage Distribution System State Estimation using Multi-Source Data

Due to the lack of sufficient online measurements for distribution system observability, pseudo-measurements from short-term load or distributed renewable energy resources (DERs) forecasting are used. However, the accuracy of them is low and thus significantly limits the performance of distribution system state estimation (DSSE). In this paper, a robust DSSE that integrates multi-source measurement data is proposed. Specifically, the historical low-voltage (LV) side smart meters are used to forecast load and DERs injections via the support vector machine (SVM) with optimally tuned parameters. By contrast, the online smart meters at LV side are utilized to derive equivalent power injections at the MV/LV transformers, yielding more accurate pseudo-measurements compared to the forecasted injections. Furthermore, to deal with bad data caused by communication loss, instrumental errors and cyber attacks, robust DSSE that relies on generalized maximum-likelihood (GM)-estimation criterion is developed. The projection statistics are developed to adjust the weights of each measurement, leading to better balance between pseudo- and real-time measurements. Numerical results conducted on modified IEEE 33-bus system with DG integration demonstrate the effectiveness and robustness of the proposed method.

distribution system state estimation↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BEYONDPLANCK III. Commander3

We describe the computational infrastructure for end-to-end Bayesian cosmic microwave background (CMB) analysis implemented by the BeyondPlanck Collaboration. The code is called Commander3. It provides a statistically consistent framework for global analysis of CMB and microwave observations and may be useful for a wide range of legacy, current, and future experiments. The paper has three main goals. Firstly, we provide a high-level overview of the existing code base, aiming to guide readers who wish to extend and adapt the code according to their own needs or re-implement it from scratch in a different programming language. Secondly, we discuss some critical computational challenges that arise within any global CMB analysis framework, for instance in-memory compression of time-ordered data, fast Fourier transform optimization, and parallelization and load-balancing. Thirdly, we quantify the CPU and RAM requirements for the current BEYONDPLANCK analysis, finding that a total of 1.5 TB of RAM is required for efficient analysis and that the total cost of a full Gibbs sample for LFI is 170 CPU-hrs, including both low-level processing and high-level component separation, which is well within the capabilities of current low-cost computing facilities. The existing code base is made publicly available under a GNU General Public Library (GPL) license.

79 ASTRONOMY AND ASTROPHYSICS↗

Occupant-driven end use load models for demand response and flexibility service participation of residential grid-interactive buildings

As demand response becomes increasingly used as a tool to support improved grid flexibility, it is important to consider that there are many potential types of energy end uses that may be used to support such flexibility. Residential appliances, often accounting for 30 % or more of residential energy use, are a currently untapped source of demand flexibility, particularly when aggregated together across homes. To date there has been very limited analysis of residential appliances for use as grid-interactive loads. As such, this research uses disaggregated energy end use data for 564 households, to model the electricity demand flexibility potential of the use of residential dishwashers, clothes washers, clothes dryers, ovens, and ranges (oven + stovetop) on both weekdays and weekends. This includes both at the building level, as well as aggregated to the grid level, specifically the Midcontinent Independent System Operator (MISO) region. This study was divided into two parts. Part 1 focuses on determining appliance-level loads, and Part 2, which involves aggregation to the grid. Findings suggest that among the studied appliances, clothes dryers provide the greatest demand reduction potential for most times of the day, followed by dishwashers and clothes washers. The maximum potential reduction for clothes dryers is found to be approximately at 11:00 a.m. and this potential sustains throughout most of the daytime period. When considering the willingness of households to participate, based on a survey of households in the Midwest region, clothes dryers still have the most potential for demand reduction. The availability of appliances for load modulation on weekdays and weekends indicates similar load reduction potential for all appliances. Overall, the results of this study suggest that there is an opportunity for shifting appliance usage to optimize grid efficiency and enhance demand response strategies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System and method of storing and analyzing information

A system and method of storing and analyzing information is disclosed. The system includes a compiler layer to convert user queries to data parallel executable code. The system further includes a library of multithreaded algorithms, processes, and data structures. The system also includes a multithreaded runtime library for implementing compiled code at runtime. The executable code is dynamically loaded on computing elements and contains calls to the library of multithreaded algorithms, processes, and data structures and the multithreaded runtime library.

Feo, John T.↗

Fuel Property Effects on Stochastic Preignition Events During Engine Load Transitions

Stochastic preignition (SPI) is an abnormal combustion phenomenon that can cause catastrophic engine damage. There have been several proposed mechanisms of SPI, where a uniform source is still not certain, however, SPI tendencies have been shown to be influenced by engine operating conditions, oil composition, engine age, and fuel chemical and physical properties. Laboratory research and testing for SPI propensity is challenging given the stochastic nature of events, as well as the potential for significant degradation of the engine platform and measuring equipment over time. Thus, SPI specific experiments are generally conducted under either sustained or cyclic patterning of steady-state operating conditions to avoid the influence of transient engine boundary conditions on test parameters of interest (e.g. oil additive package, fuel properties, engine speed/load, etc.). In this work a cyclically varying SPI test sequence involves a 5 min engine warmup period at a low engine load of around 4 bar gross indicated mean effective pressure (IMEPg), followed by a transition to high load (~20 bar IMEPg) at a constant 2000 rev/min engine speed for a total of 25 min. This individual test sequence load schedule is then sequentially repeated 10 times to generate significant statistical data for analysis. This work examines the influence of fuel chemical and physical properties on SPI tendency during the unsteady portion of the 10-cycle sequence (the first 5 min of the high load operation in each sequence of the loading cycle) which has been discarded from previous analyses due to the uncertainty in engine operating and thermal boundary conditions. Results from this analysis suggest an increasing trend in the ratio of SPI events during the unsteady test period relative to the steady test period with increasing fuel Reid Vapor Pressure (RVP), implying differences in uncontrolled ignition source terms, possibly from, fuel wall interactions and retention during the load transition phase of the test.

Splitter, Derek [ORNL] (ORCID:0000000174044047)↗

Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-the-Meter Solar

The ever-growing high penetration of ubiquitously distributed energy resources, especially behind-the-meter solar (BTM) generations, has significant impacts on nodal load (i.e., net injection) profiles and consequently caused imperative operational challenges to system operators such as regional transmission organizations (RTOs). Illustrated by real-world nodal data and examples at PJM Interconnection, this paper first discusses the application and necessity of effectively extracting daily nodal load profiles in a non-intrusive manner. More importantly, a novel bi-level architecture, including Factorization Machines (FM) learning procedure has been proposed to effectively disaggregate not only one node but every node in an RTO service territory. Specifically, FM leaning is adopted to capture the interconnections between related features to better utilize the correlation between buses in the same region and between a single bus and the zonal load. The proposed bi-level technique is numerically validated using real-world, minute-level, normalized, and anonymized nodal data at PJM service territory.

behind the meter solar, load disaggregation, load ↗

HIV drug resistance during antiretroviral therapy scale-up in Uganda, 2012–19: a population-based, longitudinal study

Background With scale-up of antiretroviral therapy (ART) in sub-Saharan Africa, increasing pretreatment HIV drug resistance has been reported; however, the broader effect of ART expansion on population-level resistance patterns remains insufficiently quantified. We aimed to estimate the longitudinal prevalence of drug resistance and resistance-conferring mutations. Methods This study used data collected as part of the Rakai Community Cohort Study (RCCS), an open population-based census and cohort study conducted in southern Uganda. At each survey round, residents aged 15–49 years are invited to participate and receive a structured questionnaire that obtains sociodemographic, behavioural, and health information, including self-reported past and current ART use. Voluntary HIV testing is conducted using a rapid test algorithm and a venous blood sample. People with HIV provide samples for viral load quantification and deep sequencing. We analysed RCCS survey, HIV viral load, and deep sequencing (which was used to predict resistance) data from five survey rounds. The key outcomes were the population prevalence of viraemic people with HIV with non-nucleoside reverse transcriptase inhibitor (NNRTI), nucleoside reverse transcriptase inhibitor (NRTI), protease inhibitor, or multiclass resistance among all participants (regardless of HIV serostatus) in the 2015 and 2017 surveys. Prevalence of class-specific resistance and resistance-conferring substitutions were estimated using robust log-Poisson regression. Findings Between Aug 10, 2011, and Nov 4, 2020, there were 43 361 participants in the RCCS and 7923 (18·27%) people with HIV. Over five survey rounds, 93 622 participant visits occurred, among which 17 460 (18·65%) were from people with HIV. Over the analysis period, the median age of study participants remained similar (28 years [22–35] in 2012 and 29 years [21–38] in 2019). Sufficient data were available to reliably genotype 4072 (90·03%) of 4523 participant visits from 3407 people with HIV for at least one drug. Overall population prevalence of resistance contributed by viraemic pretreatment people with HIV decreased between 2012 and 2017 from 0·56% (95% CI 0·42–0·75) to 0·25% (0·18–0·33) for NNRTI and from 0·24% (0·15–0·37) to 0·05% (0·02–0·10) for NRTI (prevalence ratio 0·44 [0·29–0·68] for NNRTI and 0·21 [0·09–0·47] for NRTI). Between 2012 and 2017, NNRTI resistance among viraemic pretreatment people with HIV increased from 4·86% (3·69–6·42) to 9·61% (7·27–12·7; prevalence ratio 1·98 [1·34–2·91]). The prevalence of NNRTI and NRTI resistance was substantially higher among viraemic treatment-experienced people with HIV (51·49% [46·24–57·34] for NNRTI and 36·46% [30·06–44·22] for NRTI in 2017) than among pretreatment people with HIV. NNRTI and NRTI resistance was predominantly attributable to rtK103N and rtM184V. inT97A was observed at a similar prevalence among viraemic treatment-experienced (9·96% [6·41–15·48]) and viraemic pretreatment (10·56% [8·01–13·93]) people with HIV; no major dolutegravir resistance mutations were observed. Interpretation Despite rising NNRTI resistance among pretreatment people with HIV, overall population prevalence of pretreatment HIV drug-resistant viraemia decreased due to increasing ART uptake and viral suppression. This finding underscores the crucial role of achieving and maintaining high ART coverage in reducing transmission of drug-resistant HIV. The high prevalence of mutations conferring resistance to components of first-line ART regimens among viraemic people with HIV is potentially concerning. Funding National Institutes of Health, Johns Hopkins University Center for AIDS Research, Bill & Melinda Gates Foundation, and the US Centers for Disease Control and Prevention.

59 BASIC BIOLOGICAL SCIENCES↗

A data-driven peridynamic continuum model for upscaling molecular dynamics

Nonlocal models, including peridynamics, often use integral operators that embed lengthscales in their definition. However, the integrands in these operators are difficult to define from the data that are typically available for a given physical system, such as laboratory mechanical property tests. In contrast, molecular dynamics (MD) does not require these integrands, but it suffers from computational limitations in the length and time scales it can address. To combine the strengths of both methods and to obtain a coarse-grained, homogenized continuum model that efficiently and accurately captures materials’ behavior, we propose a learning framework to extract, from MD data, an optimal Linear Peridynamic Solid (LPS) model as a surrogate for MD displacements. To maximize the accuracy of the learnt model we allow the peridynamic influence function to be partially negative, while preserving the well-posedness of the resulting model. To achieve this, we provide sufficient well-posedness conditions for discretized LPS models with sign-changing influence functions and develop a constrained optimization algorithm that minimizes the equation residual while enforcing such solvability conditions. This framework guarantees that the resulting model is mathematically well-posed, physically consistent, and that it generalizes well to settings that are different from the ones used during training. We illustrate the efficacy of the proposed approach with several numerical tests for single layer graphene. Our two-dimensional tests show the robustness of the proposed algorithm on validation data sets that include thermal noise, different domain shapes and external loadings, and discretizations substantially different from the ones used for training.

homogenization↗

Simulink Model of a New Energy EVG-005 5kW Hydropower Turbine

Simulink model for a New Energy 5kW hydropower turbine. ADCP data ("ds_streamwise_7_13.nc") and DC voltage, DC current, and rotor rotation observed from the New Energy EVG-005 Current Energy Converter (CEC) ("electrical_7_13_10ohms.nc") were collected at the Tanana River Test Site (TRTS) near Nenana Alaska. - Data was collected on July 13th, 2023 with a constant 10 ohms resistance applied with a DC load bank. - Simulink model is meant to resemble the electrical setup at the TRTS. - Model is initialized by running the "NewEnergy_2023_10hz.m" Matlab script. Then the Simulink model ("New_Energy_Model_PMSM.slx") can be run. - Results are processed with the "NewEnergy_2023_processing.m" Matlab code. The Matlab results are also saved in the "New_Energy_7_13_model_validation_results.mat" Matlab file. This can be directly loaded into the Matlab Workspace using the "Load()" command. - The timetable variables "electrical_model_downsampled" is the model results and the "electrical_limited" is the experimental data from the TRTS.

16 TIDAL AND WAVE POWER↗

Machine Learning Travel Time emulator

This notebook makes seismic phase travel time predictions using machine learning. There are 3 different machine learning models corresponding to the three regimes: local, regional, and teleseismic. After reading in the test data and splitting into the 3 regimes, we use precomputed scalers to scale the input features used to make the travel time predictions. We then load the machine learning models and use them to predict travel times for test data.

Anderson, Gemma↗

Experimental investigation of advanced turbine control strategies and load-mitigation measures with a model-scale floating offshore wind turbine system

To advance the control co-design of offshore wind energy systems, the authors perform basin-scale experiments with a fully instrumented and actuated floating offshore wind turbine model. The model consists of a 1:70 scale performance-matched model of the International Energy Agency Wind Technology Collaboration Programme 15-MW reference turbine atop the VolturnUS-S semisubmersible platform. The Reference OpenSource Controller provides real-time blade pitch and generator torque control. Here we aim to develop an open data set for the validation of numerical models in predicting the influence of turbine control and load-mitigation measures. For this purpose, we measure the effects of advanced turbine control features, including peak shaving and floating feedback as well as hull-based control using tuned mass dampers on the system. Overall, the results demonstrate measurable and consistent influences from the control and load-mitigation measures, thus confirming the usefulness as a validation data set. Peak shaving attenuates the response to wind turbulence at near-rated wind speed. Floating feedback reduces the load and platform pitch motion associated with the negative damping induced by blade pitch control. The tuned mass dampers also attenuate the system response near the targeted frequencies under suitable conditions. We also identify detrimental side effects of each load-mitigation measure.

17 WIND ENERGY↗