Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light field imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Plot-level rapid screening for photosynthetic parameters using proximal hyperspectral imaging

Abstract Photosynthesis is currently measured using time-laborious and/or destructive methods which slows research and breeding efforts to identify crop germplasm with higher photosynthetic capacities. We present a plot-level screening tool for quantification of photosynthetic parameters and pigment contents that utilizes hyperspectral reflectance from sunlit leaf pixels collected from a plot (~2 m×2 m) in <1 min. Using field-grown Nicotiana tabacum with genetically altered photosynthetic pathways over two growing seasons (2017 and 2018), we built predictive models for eight photosynthetic parameters and pigment traits. Using partial least squares regression (PLSR) analysis of plot-level sunlit vegetative reflectance pixels from a single visible near infra-red (VNIR) (400–900 nm) hyperspectral camera, we predict maximum carboxylation rate of Rubisco (Vc,max, R2=0.79) maximum electron transport rate in given conditions (J1800, R2=0.59), maximal light-saturated photosynthesis (Pmax, R2=0.54), chlorophyll content (R2=0.87), the Chl a/b ratio (R2=0.63), carbon content (R2=0.47), and nitrogen content (R2=0.49). Model predictions did not improve when using two cameras spanning 400–1800 nm, suggesting a robust, widely applicable and more ‘cost-effective’ pipeline requiring only a single VNIR camera. The analysis pipeline and methods can be used in any cropping system with modified species-specific PLSR analysis to offer a high-throughput field phenotyping screening for germplasm with improved photosynthetic performance in field trials.

59 BASIC BIOLOGICAL SCIENCES↗

Direct Imaging of Resonant Phonon-Magnon Coupling

Detection of phonons is critical for research on the interconversion between resonantly coupled magnons and phonons. Here we report the direct visualization of the resonant coupling of magnons and phonons by microfocused Brillouin light scattering on the Ni/Li Nb O 3 hybrid heterostructure. The static patterns of surface acoustic wave phonons, originating from the interference between the incident wave ψ 0 (A 0 , k, φ 0 ) and reflected wave ψ 1 (A 1 , - k, φ 1 ), can be modulated by magnetic field due to the magnon-phonon coupling. By analyzing the information of phonons obtained from Brillouin spectroscopy, the properties of the magnon system (Ni film), e.g., ferromagnetic resonance field and resonance linewidth, can be determined. The results provide spatially resolved information about phonon manipulation and detection in a coupled magnon-phonon system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hubble illuminates the universe

Latest observations by the Hubble Space Telescope (HST) are described, including the first 'parallel' observations (on January 6, 1992) by the two of the Hubble's instruments of two different targets at the same time. On this date, the faint-object camera made images of the quasar 3C 273 in Virgo, while the wide-field and planetary camera recorded an adjacent field. The new HST images include those of the nucleus and the jet of M85, the giant elliptical galaxy at the heart of the Virgo cluster, and what appears to be a black hole of mass 2.6 billion solar masses in M87, and an image of N66, a planetary nebula in the LMC. Other images yield evidence of 'blue stragglers' in the core of 47 Tucanae, a globular cluster about 16,000 light-years from earth. The Goddard spectrograph recorded the spectrum of the star Capella at very high wavelength resolution, which made it possible to measure deuterium from the Big Bang.

Maran, Stephen P.↗

Using Computational Flow Imaging to Optimize Filtered Rayleigh Scattering Measurements of an Isolator Shock Train

Filtered Rayleigh scattering (FRS) is a laser diagnostic where the intensity of elastically scattered light is measured after it passes through a molecular absorption filter. The filter removes background interference that overwhelms the relatively weak scattering from the gas molecules. However, with a filter, the measured light intensity depends on many of the scattering gas properties, including pressure, density, temperature, and velocity. In this work, CFD simulations of an isolator shock train flow field are input into a physics-based model to predict the values of FRS intensity measurements in a proposed experiment. The goal is to evaluate if a simplistic FRS setup (that utilizes one camera, laser, and absorption filter) can be used to accurately quantify number density despite the fact that the scattered light intensity also depends on other gas properties. It is found that the experimental setup can be optimized such that a linear relationship describes the number density with an average prediction error of 2%. The vast majority of the flow exhibits prediction errors of less than 3%, but small regions of the flow reach up to 11% error. A sensitivity analysis shows that the prediction error increases with the central wavelength of the incident laser light and decreases with the angle between the camera and laser propagation directions. The optimal experimental parameters are chosen based on a compromise between the prediction error, spatial resolution, and the amount of unfiltered light. In the future, the proposed FRS setup will be implemented to acquire new and valuable information on an isolator shock train, a flow field that has been traditionally studied using wall static pressure measurements and path-integrated visualization techniques, such as schlieren and shadowgraphy.

Hunt, Robin L.↗

Single-particle scattering spectroscopy: fundamentals and applications

Metallic nanoparticles supporting a localized surface plasmon resonance have emerged as promising platforms for nanoscopic labels, sensors, and (photo-) catalysts. To use nanoparticles in these capacities, and to gain mechanistic insight into the reactivity of inherently heterogeneous nanoparticles, single-particle characterization approaches are needed. Single-particle scattering spectroscopy has become an important, highly sensitive tool for localizing single plasmonic nanoparticles and studying their optical properties, local environment, and reactivity. In this review, we discuss approaches taken for collecting the scattered light from single particles, their advantages and disadvantages, and present some recent applications. We introduce techniques for the excitation and detection of single-particle scattering such as high-angle dark-field excitation, total internal reflection dark-field excitation, scanning near-field microscopy, and interferometric scattering. We also describe methods to achieve polarization-resolved excitation and detection. We then discuss different approaches for scanning, ratiometric, snapshot, and interferometric hyperspectral imaging techniques used to extract spectral information. Finally, we provide a brief overview of specialized setups for in situ measurements of nanoparticles in liquid systems and setups coupled to scanning tip microscopes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Idealized simulation study of the relationship of disdrometer sampling statistics with the precision of precipitation rate measurement

Due to the discretized nature of rain, the measurement of a continuous precipitation rate by disdrometers is subject to statistical sampling errors. Here, Monte Carlo simulations are employed to obtain the precision of rain detection and rate as a function of disdrometer collection area and compared with World Meteorological Organization guidelines for a 1 min sample interval and 95 % probability. To meet these requirements, simulations suggest that measurements of light rain with rain rates R ≤ 0.50 mm h-1 require a collection area of at least 6 cm × 6 cm, and for R = 1 mm h -1 , the minimum collection area is 13 cm × 13 cm. For R = 0.01 mm h -1 , a collection area of 2 cm × 2 cm is sufficient to detect a single drop. Simulations are compared with field measurements using a new hotplate device, the Differential Emissivity Imaging Disdrometer. The field results suggest an even larger plate may be required to meet the stated accuracy, likely in part due to non-Poissonian hydrometeor clustering.

54 ENVIRONMENTAL SCIENCES↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

A chemical analysis of soil-water mixtures and the first microscopic images of martian soil will be among the results to be returned by the Mars Environmental Compatibility Assessment (MECA) payload on the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's primary goal is to evaluate potential geochemical and environmental hazards that may confront future martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. As a survey of soil properties, the MECA data set will also be rich in information relevant to basic geology, paleoclimate, and exobiology. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. MECA is allocated a mass of 10 kg and a peak power usage of 15 W within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases. Cyclic voltammetry will address oxidants, and anodic stripping voltammetry will probe potentially hazardous trace metals. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in a controlled illumination environment to image dust and soil particles from millimeters to nanometers in size. Careful selection of substrates and an abrasion tool allows experimental study of size distribution, adhesion, abrasion, hardness, color, shape, aggregation, magnetic and other properties. Mounted on the end of the robot arm, MECA's electrometer consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultra-violet- light-induced ions and a low-voltage break-down threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. In addition, the electrostatic environment is key to transport of dust and, consequently, martian meteorology. MECA will also observe natural dust accumulation on engineering materials. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the inter-action between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. Dust accumulation as a function of conductivity, magnetic field strength, and other parameters will be explored. The MECA instruments described above will assess potential hazards that the Martian soil might present to human explorers and their equipment. In addition, MECA will provide information on the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation. Additional information is contained in the original extended abstract.

Hecht, M. H.↗

Gravity Sensors and the Role of 3-D Visualization and Simulation in Biomedical Research

Ross 3.0 software was developed in the Biocomputation Center for semi-automated reconstruction of objects from serial thin sections. Data are captured directly from a transmission electron microscope via a video camera to a graphics workstation where the sections are mosaicked and contours are traced, registered and displayed by semi-automated methods. For the first time, macular type II cells are described completely for their innervation patterns. The purposes are to learn more about the fundamental circuitry of the macula and to demonstrate whether the terminals are altered morphologically by space flight. Current examples, from the medial part of the macula, are from maculas collected in-flight on the Space Life Sciences-2 mission, 4.5 hrs post-flight, and from a ground control. Results show that the typical type 11 cell receives processes from up to six nearby calyces or afferents. Nearly all the processes are elongated; some have bouton-like swellings and numerous vesicles. Multiple (2 to 4) processes from a single calyx to a type II cell are common, and approx. 1/3 of the processes innervate 2 type II cells of a neighboring cluster of 3 cells. About 2% of type II cells resemble type I cells morphologically and are surrounded by demicalyces. Differences in size or shape of the terminals under flight conditions could not be determined because the sample size is still too small; but it is clear that reconstruction methods provide insights into macular circuitry not obtainable by other techniques. The results demonstrate a morphological basis for interactions between adjacent receptive fields, through feedback-feedforward connections, during preprocessing of linear acceleratory information by the maculas. While the methods are currently being tested using vestibular maculas as the model system, it is clear that the technology is applicable to any tissue that can be physically or optically sectioned. ROSS software has already been implemented for reconstructing objects from tissues studied by confocal and by transmitted light microscopy, and research into magnetic resonance imaging-computational tomography combined visualization are underway.

Ross, Muriel D.↗

Substrate-enhanced photothermal nano-imaging of surface polaritons in monolayer graphene

Surface polaritons comprise a wealth of light–matter interactions with deep sub-wavelength scale confinement of electromagnetic modes. However, their nanoscale localized dissipation and thermalization processes are not readily accessible experimentally. Here, we introduce photothermal force microscopy to image surface plasmon polaritons (SPPs) in monolayer graphene through their non-radiative SiO2 substrate dissipation. We demonstrate the real-space SPP imaging via photo-induced atomic force detection, and from comparison with scattering-type scanning near-field optical microscopy imaging attribute the force response to substrate dissipation-enhanced thermal expansion. This work illustrates that nano-optical tip–sample induced dissipative forces facilitate a direct mechanical detection of surface polariton interactions with monolayer sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High speed ultraviolet digital image correlation (UV-DIC) for dynamic strains at extreme temperatures

Digital Image Correlation (DIC) is a camera-based method of measuring full-field displacements and strains from the surface of a deforming object. It can be applied at any length scale (determined by the lenses) and any time scale (determined by the camera), and because it is non-contacting, it can also be used at temperatures much higher than can be withstood by bonded strain gauges. At extreme temperatures, materials emit light in the form of blackbody radiation, which can saturate the camera sensor. It has previously been shown that the emitted light can be effectively screened by using ultraviolet (UV) cameras, lenses, and filters; however, commercially available UV cameras are relatively slow, which limits the speed of combined UV-DIC measurements. In this study, a UV intensifier was paired with a high-speed camera, and its ability to perform UV-DIC at high temperature and high speed was investigated. The system was compared over three different experiments: (A) a quasi-static thermal expansion test at high temperature, (B) a vibration test at room temperature, and (C) the same vibration test repeated at high temperature. The system successfully performed DIC up to at least 1600 °C at frame rates of 5000 fps, which is more than 100 times faster than other examples of UV-DIC in the literature. In all cases, measurements made using the UV intensifier were much noisier than those made without the intensifier, but the intensifier enabled measurements at temperatures well above those which an unfiltered high-speed camera otherwise saturates.

47 OTHER INSTRUMENTATION↗

Facilitating the exploitation of ERTS imagery using snow enhancement techniques

The author has identified the following significant results. New fracture detail within New England test area has been interpreted from ERTS-1 images. Comparative analysis of snow-free imagery (1096-15065 and 1096-15072) has demonstrated that MSS bands 5 and 7 supply the greatest amount of geological fracture detail. Interpretation of the first snow-covered ERTS-1 images (1132-15074 and 1168-15065) in correlation with ground snow depth data indicates that a heavy blanket of snow (less than 9 inches) accentuates major structural features while a light dusting (greater than 1 inch) accentuates more subtle topographic expressions. Snow cover was found to accentuate drainage patterns which are indicative of lithological and/or structural variations. Snow cover provided added enhancement for viewing and detecting topographically expressed fractures and faults. A recent field investigation was conducted within the New England test area to field check lineaments observed from analysis of ERTS-1 imagery, collect snow depth readings, and obtain structural joint readings at key locations in the test area.

Wobber, F. J.↗

The Ames MER Microscopic Imager Toolkit

The Mars Exploration Rovers, Spirit and Opportunity, have spent several successful months on Mars, returning gigabytes of images and spectral data to scientists on Earth. One of the instruments on the MER rovers, the Athena Microscopic Imager (MI), is a fixed focus, megapixel camera providing a plus or minus mm depth of field and a 3lx31mm field of view at a working distance of 63 mm from the lens to the object being imaged. In order to maximize the science return from this instrument, we developed the Ames MI Toolkit and supported its use during the primary mission. The MI Toolkit is a set of programs that operate on collections of MI images, with the goal of making the data more understandable to the scientists on the ground. Because of the limited depth of field of the camera, and the often highly variable topography of the terrain being imaged, MI images of a given rock are often taken as a stack, with the Instrument Deployment Device (IDD) moving along a computed normal vector, pausing every few millimeters for the MI to acquire an image. The MI Toolkit provides image registration and focal section merging, which combine these images to form a single, maximally in-focus image, while compensating for changes in lighting as well as parallax due to the motion of the camera. The MI Toolkit also provides a 3-D reconstruction of the surface being imaged using stereo and can embed 2-D MI images as texture maps into 3-D meshes produced by other imagers on board the rover to provide context. The 2-D images and 3-D meshes output from the Toolkit are easily viewed by scientists using other mission tools, such as Viz or the MI Browser. This paper describes the MI Toolkit in detail, as well as our experience using it with scientists at JPL during the primary MER mission.

Sargent, Randy↗

Landsat 9: Status and Plans

The Landsat 9 mission, currently under development and proceeding towards a targeted launch in late 2020, will be very similar to the Landsat 8 mission, launched in 2013. Like Landsat 8, Landsat 9 is a joint effort between NASA and USGS with two sensors, the Operational Land Imager 2 (OLI-2), essentially a copy of the OLI on Landsat 8 and the Thermal Infrared Sensor 2 (TIRS-2), very similar to the TIRS on Landsat 8. The OLI-2, like OLI, provides 14-bit image data, though for Landsat 9, all 14 bits will be retained and transmitted to the ground. The focal plane modules to be used for OLI-2 were flight spares for OLI and are currently being retested by Ball Aerospace. Results indicate radiometric performance comparable to OLI. The TIRS was a class C instrument, with a 3-year design lifetime, and therefore had limited redundancy. TIRS-2 will be a class B instrument, with a 5-year design lifetime, like OLI (and OLI-2), necessitating design changes to increase redundancy. The stray light and Scene Select Mechanism (SSM) encoder problems observed on orbit with TIRS have also instigated a few design changes to TIRS-2. Stray light analysis and testing have indicated that additional baffles in the TIRS-2 optical system will suppress the out-of-field response. The SSM encoder problems have not been definitively traced to a route cause, though conductive anodic filament growth in the circuit boards is suspected. Improved designs for the encoder are being considered for TIRS-2. The spare Focal Plane Array (FPA) from TIRS is planned for use in TIRS-2; FPA spectral and radiometric performance testing is scheduled for September of this year at NASA's Goddard Space Flight Center.

Landsat↗

Giant Enhancement of Four-Wave Mixing by Doubly Zone-Folded Nonlocal Metasurfaces

Resonant optical metasurfaces hold promise for enhancing nonlinear optical signals and manipulating their fundamental properties. However, they rarely excel at amplifying signals from nonlinear processes with two incident pump beams, such as four-wave mixing (FWM) or sum-frequency generation. Frequency-mixing experiments impose challenging requirements for metasurface design due to the need to support multiple optical resonances with compatible field profiles at specified resonant wavelengths, often across a substantial spectral separation. Here, in this work, we introduce nonlocal ‘quadromer’ metasurfaces containing four nanostructures per unit cell as the key to unlocking configurable, multiresonant metasurfaces that enhance frequency-mixing processes. As a proof of concept, we experimentally demonstrate enhanced FWM using quadromer metasurfaces made of silicon and silicon-rich silicon nitride. The results are relevant for applications such as imaging of infrared light upconverted into the visible spectrum and the generation of quantum light via spontaneous FWM.

four-wave mixing↗

Polarimetric Multispectral Imaging Technology

The Jet Propulsion Laboratory is developing a remote sensing technology on which a new generation of compact, lightweight, high-resolution, low-power, reliable, versatile, programmable scientific polarimetric multispectral imaging instruments can be built to meet the challenge of future planetary exploration missions. The instrument is based on the fast programmable acousto-optic tunable filter (AOTF) of tellurium dioxide (TeO2) that operates in the wavelength range of 0.4-5 microns. Basically, the AOTF multispectral imaging instrument measures incoming light intensity as a function of spatial coordinates, wavelength, and polarization. Its operation can be in either sequential, random access, or multiwavelength mode as required. This provides observation flexibility, allowing real-time alternation among desired observations, collecting needed data only, minimizing data transmission, and permitting implementation of new experiments. These will result in optimization of the mission performance with minimal resources. Recently we completed a polarimetric multispectral imaging prototype instrument and performed outdoor field experiments for evaluating application potentials of the technology. We also investigated potential improvements on AOTF performance to strengthen technology readiness for applications. This paper will give a status report on the technology and a prospect toward future planetary exploration.

Cheng, L.-J.↗

Terrestrial Planet Finder Coronagraph Optical Modeling

The Terrestrial Planet Finder Coronagraph will rely heavily on modeling and analysis throughout its mission lifecycle. Optical modeling is especially important, since the tolerances on the optics as well as scattered light suppression are critical for the mission's success. The high contrast imaging necessary to observe a planet orbiting a distant star requires new and innovative technologies to be developed and tested, and detailed optical modeling provides predictions for evaluating design decisions. It also provides a means to develop and test algorithms designed to actively suppress scattered light via deformable mirrors and other techniques. The optical models are used in conjunction with structural and thermal models to create fully integrated optical/structural/thermal models that are used to evaluate dynamic effects of disturbances on the overall performance of the coronagraph. The optical models we have developed have been verified on the High Contrast Imaging Testbed. Results of the optical modeling verification and the methods used to perform full three-dimensional near-field diffraction analysis are presented.

space telescopes↗

Video Guidance Sensor and Time-of-Flight Rangefinder

A proposed video guidance sensor (VGS) would be based mostly on the hardware and software of a prior Advanced VGS (AVGS), with some additions to enable it to function as a time-of-flight rangefinder (in contradistinction to a triangulation or image-processing rangefinder). It would typically be used at distances of the order of 2 or 3 kilometers, where a typical target would appear in a video image as a single blob, making it possible to extract the direction to the target (but not the orientation of the target or the distance to the target) from a video image of light reflected from the target. As described in several previous NASA Tech Briefs articles, an AVGS system is an optoelectronic system that provides guidance for automated docking of two vehicles. In the original application, the two vehicles are spacecraft, but the basic principles of design and operation of the system are applicable to aircraft, robots, objects maneuvered by cranes, or other objects that may be required to be aligned and brought together automatically or under remote control. In a prior AVGS system of the type upon which the now-proposed VGS is largely based, the tracked vehicle is equipped with one or more passive targets that reflect light from one or more continuous-wave laser diode(s) on the tracking vehicle, a video camera on the tracking vehicle acquires images of the targets in the reflected laser light, the video images are digitized, and the image data are processed to obtain the direction to the target. The design concept of the proposed VGS does not call for any memory or processor hardware beyond that already present in the prior AVGS, but does call for some additional hardware and some additional software. It also calls for assignment of some additional tasks to two subsystems that are parts of the prior VGS: a field-programmable gate array (FPGA) that generates timing and control signals, and a digital signal processor (DSP) that processes the digitized video images. The additional timing and control signals generated by the FPGA would cause the VGS to alternate between an imaging (direction-finding) mode and a time-of-flight (range-finding mode) and would govern operation in the range-finding mode.

Bryan, Thomas↗

Effect of Inductive Coil Geometry on the Operating Characteristics of a Pulsed Inductive Plasma Accelerator

Operational characteristics of two separate inductive thrusters with coils of different cone angles are explored through thrust stand measurements and time-integrated, un- filtered photography. Trends in impulse bit measurements indicate that, in the present experimental configuration, the thruster with the inductive coil possessing a smaller cone angle produced larger values of thrust, in apparent contradiction to results of a previous thruster acceleration model. Areas of greater light intensity in photographs of thruster operation are assumed to qualitatively represent locations of increased current density. Light intensity is generally greater in images of the thruster with the smaller cone angle when compared to those of the thruster with the larger half cone angle for the same operating conditions. The intensity generally decreases in both thrusters for decreasing mass ow rate and capacitor voltage. The location of brightest light intensity shifts upstream for decreasing mass ow rate of propellant and downstream for decreasing applied voltage. Recognizing that there typically exists an optimum ratio of applied electric field to gas pressure with respect to breakdown efficiency, this result may indicate that the optimum ratio was not achieved uniformly over the coil face, leading to non-uniform and incomplete current sheet formation in violation of the model assumption of immediate formation where all the injected propellant is contained in a magnetically-impermeable current sheet.

Hallock, Ashley K.↗