Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Wireless Power Transfer

Wireless Power Transfer is an innovative approach using magnetic resonance coupling of air core transformers designed for today's growing plug-in electric vehicle market. This technology can provide a convenient, safe and flexible means to charge electric vehicles under stationary and dynamic conditions. Plug-in Electric Vehicles (PEV) are burdened by the need for cable and plug charger, galvanic isolation of the on-board electronics, bulk and cost of this charger and the large energy storage system (ESS) packs needed. With a system where you have to physically plug in there are a number of occasions where the owner could very well forget to charge the vehicle. For stationary applications (like charging of a PHEV at home), ORNL's innovative wireless power transfer technology adds a convenience factor compared to actually plugging in which will mean that the vehicle will have a full charge every morning. Electric vehicle charging must be safe, compact and efficient in order to be convenient for customers. By reconfiguring the transformer and altering the resonance frequency, energy is transferred to the battery with lower energy losses and with fewer demands on the primary circuit by the rest of the transformer system. The ORNL discovery shows that sufficient power for the battery can be transferred from the primary to secondary circuits without significant energy losses if the operating frequency is set at 50% to 95% of the resonance frequency of the circuit. The electrical power is then transmitted to the chargeable battery, which is electrically coupled to the secondary circuit through the air core transformer. Some advantages include: Reduced energy losses during transfer of energy to the battery; A charge potential that is relatively unaffected by up to 25% misalignment of vehicle; and Other receiving components draw less power from the primary circuit. These advantages allow wireless power technology applications to expand at the workplace and beyond as the demand for EV rises. For vehicles that operate over a fixed route such as busses and shuttle vehicles, Wireless Power Transfer (WPT) means that a smaller battery pack can be used. In the traditional system, the battery pack is designed to accommodate the needs of the entire route or shift. With WPT the battery can be downsized because it can be charged when the vehicle stops on its route (a rental car shuttle bus, for example, can charge when it waits in the terminal and again when it waits at the rental car place. Thus the battery only needs enough charge to get to the next stop. This decrease in battery size means significant cost savings to electrify the vehicle. This technology enables efficient "opportunity charging stations" for predefined routes and planned stops reducing down time. Charging can occur in minutes. This improvement also eliminates the harmful emissions that occur in garages while buses are at idle during charging. In larger cities, dynamic charging offers an even greater impact utilizing existing infrastructure. As vehicles travel along busy freeways and interstate systems, wireless charging can occur while the vehicle is in motion. With this technology a vehicle essentially has unlimited electric range while using a relatively small battery pack. In-motion charging stations use vehicle sensors to alert the driver. Traveling at normal speeds, sensors establish in-motion charging. WPT transmit pads sequentially energize to the negotiated power level based on vehicle speed and its requested charging energy. Lower power when vehicle speed is slow and much higher power for faster moving vehicles. Vehicle to Infrastructure communications (V2I) coordinates WPT charging level according to on-board battery pack state-of-charge. V2I activates the roadway transmit pads placing them in standby mode and negotiates charging fee based on prevailing grid rate and vehicle energy demand. Dynamic charging would allow electricity to supply a very large fraction of the energy for the transportation sector and reduce greatly petroleum consumption. Previously worrisome traffic delays now provide longer periods of charge while passing over in-motion chargers. Inclement weather such as rain and snow do not affect the charging capability. At ORNL, we are working to develop the robust nature of wireless power technology to provide a convenient, safe and flexible means to charge electric vehicles under stationary and dynamic conditions.

33 ADVANCED PROPULSION SYSTEMS↗

A SIMULATION BASED APPROACH TO IMPACT ASSESSMENT OF PHYSICAL FAULTS: LARGE COMMERCIAL BUILDING HVAC CASE STUDY

We develop a simulation-based approach to fault impact analysis for a single duct VAV system, and analyze the dynamic and steady-state impact of equipment physical faults on building operation. The simulation model, a virtual testbed, can capture physical faults in the HVAC system of a large commercial building. The model can be utilized for generating data that can then be analyzed to quantify the impact of single or multiple faults. We illustrate the implementation of three physical faults: supply air temperature sensor bias, outdoor air temperature sensor bias, and cooling coil valve stuck. We simulate each fault with several fault intensity levels and at different seasonal operating conditions. Then, we analyze the impact of the above-mentioned faults using the metrics. The results show that the impact of a given physical fault depends on implemented control logic sequence and the seasonal operating conditions.

Chen, Yan↗

Fission-powered in-core thermoacoustic sensor

A thermoacoustic engine is operated within the core of a nuclear reactor to acoustically telemeter coolant temperature (frequency-encoded) and reactor power level (amplitude-encoded) outside the reactor, thus providing the values of these important parameters without external electrical power or wiring. We present data from two hydrophones in the coolant (far from the core) and an accelerometer attached to a structure outside the reactor. Furthermore, these signals have been detected even in the presence of substantial background noise generated by the reactor's fluid pumps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing the limitations of commercial sensors and models for supporting marine carbon dioxide removal monitoring: a case study

Several unknowns remain surrounding marine Carbon Dioxide Removal (mCDR) monitoring, reporting, and verification (MRV) practices and capabilities. Current in-situ sensor technology is limited (primarily pH and pCO 2 ), requiring calculations and assumptions to estimate changes in carbonate chemistry parameters, including total alkalinity (TA). Considering that cost, energy consumption, and accuracy of commercial sensors can vary by orders of magnitude, understanding how well existing sensors perform in an mCDR context is important for this emerging community. Likewise, documenting sensor limitations and how relatively simple models can optimize sensor deployments will improve MRV efforts and support protocol development. Here we (1) compare performance a variety of commercially available sensors in a blind mesocosm experiment simulating ocean alkalinity enhancement (OAE), and how sensor performance impacted carbonate chemistry estimates; (2) evaluate if sensors can distinguish the OAE signal from natural variability during a small scale OAE field test in Sequim Bay, WA, USA, and (3) use an idealized ocean biogeochemistry model to explore optimal sensor network design based on (1) and (2). Our mesocosm results indicate that correctly constraining pH uncertainty will be critical for accurate TA estimates with current sensor technology compared to the less impactful variation caused by uncertainty in pCO 2 (pH data that are presented throughout are reported on the total scale (pH T ) unless otherwise noted). Our pilot field test demonstrated that sensors were capable of distinguishing mCDR signatures from natural variability under optimal real-world conditions. Idealized modeling simulations of the field test showed that a range of sparse and dense (3 to 100) sensors sampling areas of detectable increases will underestimate the net change in surface pH by at least 35–55%, at both realistic and highly elevated alkalinity input levels. We also highlight the limitations of current sensing technology for MRV, and the importance of ocean biogeochemistry models as critical tools for predicting when and where mCDR signals will be detectable using available sensors. Overall, our findings suggest that commercially available pCO 2 sensors and some pH sensors will form an important backbone for mCDR MRV tasks, though complete MRV characterization will require these data to be used in combination with other tools.

OAE↗

Assessment of Flow-Enhanced Sensors for Actinide Quantification in MSRs

This report serves as the deliverable for Milestone M2RS-22AN0401062 that is part of Work Package RS-22AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone is to assess the capabilities of flow-enhanced electrochemical sensors (FEES) to quantify actinides in molten salt reactors. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits in order to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. To support this work, Argonne constructed a molten salt flow system to serve as a testbed for the development of safeguards and process monitoring-relevant sensors in challenging molten salt flow conditions. Through extensive flow testing using UCl3-bearing salts, Argonne has been able to show that the FEES are able to make good measurements of salt composition. Concentration measurements with a mean absolute error of 0.09 wt% have been achieved for representative fuel salt mixtures across a range of UCl3 loadings. Repeatability was also good, with the relative standard deviation from repeated measurements being less than 1.0%. These sensors have also been shown to be able to measure the flow rate of the salt within the flow system’s transfer line. Although the accuracy of the sensors has been good, the sensors have thus far not been able to achieve performance good enough to satisfy the nuclear material accountancy requirements in 10 CFR 74. To do so, accuracy levels of 0.1% must be achieved; the FEES when operated in Argonne’s flow system have so far only been able to achieve relative errors of approximately 5.0%. Much of the error that has been observed at this stage is due to challenges in maintaining a stable salt composition in the molten salt flow system, and it is not believed that there are any inherent flaws in the sensor design. Nonetheless, the high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will likely be needed to push the measurement accuracy to the needed level.

Moore, Colin E.↗

Microvesicles released constitutively from prostate cancer cells differ biochemically and functionally to stimulated microvesicles released through sublytic C5b-9

We have classified microvesicles into two subtypes: larger MVs released upon stimulation of prostate cancer cells, sMVs, and smaller cMVs, released constitutively. cMVs are released as part of cell metabolism and sMVs, released at 10-fold higher levels, produced upon activation, including sublytic C5b-9. From electron microscopy, nanosight tracking analysis, dynamic light scattering and flow cytometry, cMVs (194–210 nm in diameter) are smaller than sMVs (333–385 nm). Furthermore, using a Quartz Crystal Microbalance measuring changes in resonant frequency (Δf) that equate to mass deposited on a sensor, an sMV and a cMV are estimated at 0.267 and 0.241 pg, respectively. sMVs carry more calcium and protein, express higher levels of lipid rafts, GPI-anchored CD55 and phosphatidylserine including deposited C5b-9 compared to cMVs. This may allude to biological differences such as increased bound C4BP on sMVs inhibiting complement more effectively. - Highlights: • Prostate cells release microvesicles constitutively (cMVs) or upon stimulus (sMVs). • sMVs are larger than cMVs and carry more protein, lipid rafts and surface PstSer. • sMVs inhibit complement more effectively than cMVs.

60 APPLIED LIFE SCIENCES↗

Heralded Generation of an Atomic NOON State

We report the heralded generation of an atomic NOON state by observation of phase super resolution in a motion-sensitive spin-wave (SW) interferometer. The SW interferometer is implemented by generating a superposition of two SWs and observing the interference between them, where the interference fringe is sensitive to the atomic collective motion. By heralded generation of a second order NOON state in the SW interferometer, we observe the interference pattern which provides strong evidence of phase super resolution. The demonstrated SW interferometer can in principle be scaled up to a highly entangled state, and thus is of fundamental importance, and might be used as an inertial sensor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Opportunities and challenges for structural health monitoring of radioactive waste systems and structures

Radioactive waste systems and structures (RWSS) are safety-critical facilities in need of monitoring over prolonged periods of time. Structural health monitoring (SHM) is an emerging technology that aims at monitoring the state of a structure through the use of networks of permanently mounted sensors. SHM technologies have been developed primarily within the aerospace and civil engineering communities. This paper addresses the issue of transitioning the SHM concept to the monitoring of RWSS and evaluates the opportunities and challenges associated with this process. Guided wave SHM technologies utilizing structurally-mounted piezoelectric wafer active sensors (PWAS) have a wide range of applications based on both propagating-wave and standing-wave methodologies. Hence, opportunities exist for transitioning these SHM technologies into RWSS monitoring. However, there exist certain special operational conditions specific to RWSS such as: radiation field, caustic environments, marine environments, and chemical, mechanical and thermal stressors. In order to address the high discharge of used nuclear fuel (UNF) and the limited space in the storage pools the U.S. the Department of Energy (DOE) has adopted a 'Strategy for the Management and Disposal of Used Nuclear Fuel and High-Level Radioactive Waste' (January 2013). This strategy endorses the key principles that underpin the Blue Ribbon Commission's on America's Nuclear Future recommendations to develop a sustainable program for deploying an integrated system capable of transporting, storing, and disposing of UNF and high-level radioactive waste from civilian nuclear power generation, defense, national security, and other activities. This will require research to develop monitoring, diagnosis, and prognosis tools that can aid to establish a strong technical basis for extended storage and transportation of UNF. Monitoring of such structures is critical for assuring the safety and security of the nation's spent nuclear fuel until a national policy for closure of the nuclear fuel cycle is defined and implemented. In addition, such tools can provide invaluable and timely information for verification of the predicted mechanical performance of RWSS (e.g. concrete or steel barriers) during off-normal occurrence and accident events such as the tsunami and earthquake event that affected Fukushima Daiichi nuclear power plant. The ability to verify the conditions, health, and degradation behavior of RWSS over time by applying nondestructive testing (NDT) as well as development of nondestructive evaluation (NDE) tools for new degradation processes will become challenging. The paper discusses some of the challenges associated to verification and diagnosis for RWSS and identifies SHM technologies which are more readily available for transitioning into RWSS applications. Fundamental research objectives that should be considered for the transition of SHM technologies (e.g., radiation hardened piezoelectric materials) for RWSS applications are discussed. The paper ends with summary, conclusions, and suggestions for further work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Application Space Expansion for the Sensor Fish

The Pacific Northwest National Laboratory has developed an instrument known as the sensor fish that can be released into downstream passage routes at hydropower facilities to collect data on the physical conditions that a fish might be exposed to during passage through a turbine. The US Department of Energy Wind and Water Power Program sees value in expanding the sensor fish application space beyond large Kaplan turbines in the northwest United States to evaluate conditions to which a greater variety of fish species are exposed. Development of fish-friendly turbines requires an understanding of both physical passage conditions and biological responses to those conditions. Expanding the use of sensor fish into other application spaces will add to the knowledge base of physical passage conditions and could also enhance the use of sensor fish as a site-specific tool in mitigating potential impacts to fish populations from hydropower. The Oak Ridge National Laboratory (ORNL) National Hydropower Assessment Program (NHAAP) database contains hydropower facility characteristics that, along with national fish distribution data, were used to evaluate potential interactions between fish species and project characteristics related to downstream passage issues. ORNL developed rankings for the turbine types in the NHAAP database in terms of their potential to impact fish through injury or mortality during downstream turbine passage. National-scale fish distributions for 31 key migratory species were spatially intersected with hydropower plant locations to identify facilities where turbines with a high threat to fish injury or mortality overlap with the potential range of a sensitive fish species. A dataset was produced that identifies hydropower facilities where deployment of the sensor fish technology might be beneficial in addressing issues related to downstream fish passage. The dataset can be queried to target specific geographic regions, fish species, license expiration dates, generation capacity levels, ownership characteristics, turbine characteristics, or any combination of these metrics.

13 HYDRO ENERGY↗

Streamflow measurements from four sites on the Tuolumne River in Yosemite National Park from Water Years 2002 to 2021

Regions with remote and complex terrain experience spatially varying streamflow patterns, but are often poorly sampled due to difficult access. This data package includes streamflow measurements collected using low-visibility and low-impact installations at four sites on the Tuolumne River in Yosemite National Park, for water years 2002 to 2021. The resulting data set offers a unique opportunity to explore hydrologic processes in complex terrain.This data package contains half-hourly recordings of unvented pressure, vented pressure, and water temperature are measured and used to estimate discharge and stage height. Discharge flags provide insight into data anomalies. This dataset is formatted in accordance with ESS-Dive's Hydrologic Monitoring and File Level Metadata Formats. It contains the following files:1) Folder containing four csv files of time series streamflow measurements (unvented pressure, vented pressure, estimated discharge, water temperature, stage height, and discharge flag) from four locations on the Tuolumne River2) Data dictionary (dd.csv) containing units, definitions, human readable column names, and data type for all column headers throughout the dataset3) File-level metadata (FLMD.csv) containing metadata for files contained in the dataset4) Installation methods (InstallationMethods.csv) containing metadata on sensor installation

54 ENVIRONMENTAL SCIENCES↗

Pressure Sensor and Telemetry Methods for Measurement While Drilling in Geothermal Wells (Final Technical Report)

The development and demonstration in this digital telemetry project has brought SiC-based high temperature electronics to a new level of complexity and integration with the active electronic devices and the packaging materials operating at 300°C for greater than 2000 hours. Our highest level of integration is a 6x6mm die with 474 transistors with the most complex functionality to date. Advances were made in the area of device modeling and fabrication, circuit simulation and design, device testing, and packaging. The technologies developed here would help enable sensor systems in enhanced geothermal systems, as well as other applications with high temperature requirements.

15 GEOTHERMAL ENERGY↗

Assembly and Functional Test of NRAD Heated Instrumentation Rig

This is a technical report (TEV-4296) which documents the configuration and materials of construction for a heated sensor test conducted in the NRAD reactor. It is being reviewed for external release so that operators of university reactors can evaluate whether this level of documentation will be acceptable for similar tests conducted in their reactors. The Objective section of this TEV is reproduced below. The purpose of this TEV is to document assembly and functional testing of a device which is designed to allow advanced sensors to be temporarily placed at the periphery of the NRAD reactor. While in this location, the operational characteristics of the sensors can be evaluated while they are exposed to a neutron flux. This device (or “rig”) consists of a cartridge heater surrounded by six guide tubes, which are in turn surrounded by insulation and an aluminum dry tube. The heater allows for the sensors to be tested while at elevated temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Temporal Study 2022-2024: Sample-Based Surface Water Dissolved Inorganic Carbon, Dissolved Organic Carbon, Total Nitrogen, Stable Isotopes, and Total Suspended Solids from across Multiple Watersheds in the Yakima River Basin, Washington, USA

This dataset supports a broader study examining the drivers of temporal variability in sediment respiration rates in the Yakima River Basin. The dataset provides geochemistry data generated from samples collected at bi-weekly or monthly intervals at six sites across the Yakima River Basin in Washington, USA. Sample and sensor data from previous years (2021-2022) can be found at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1898912 and https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1892054, respectively. Related sensor data from 2022-2024 will be published separately. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) readme; (4) field metadata; (5) dissolved inorganic carbon (DIC) and averages; (6) dissolved organic carbon (DOC; reported as non-purgeable organic carbon; NPOC) and averages; (7) total dissolved nitrogen (TN) and averages; (8) total suspended solids (TSS); (9) stable isotopes; (10) surface water sampling protocol; (11) sensor protocol; (12) methods codes; and (13) international generic sample number (IGSN) mapping file. All files are .csv or .pdf. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About. For data and scripts associated with "Shifts in rain-snow partitioning drive faster water transit times in the US Pacific Northwest" (Butler et al., 2026), go to https://data.ess-dive.lbl.gov/datasets/doi:10.15485/3025481

18-O↗

Acoustic Environment of Admiralty Inlet: Broadband Noise Measurements

Admiralty Inlet has been selected as a potential tidal energy site. It is located near shipping lanes, is a highly variable acoustic environment, and is frequented by the highly endangered southern resident killer whale (SRKW). Resolving environmental impacts is the first step to receiving approval to deploy tidal turbines at Admiralty Inlet. Of particular concern is the potential for blade strike or other negative interactions between the SRKW and the tidal turbine. A variety of technologies including passive and active monitoring systems are being considered as potential tools to determine the presence of SRKW in the vicinity of the turbines. Broadband noise level measurements are critical for the determination of design and operation specifications of all marine and hydrokinetic energy capture technologies. Acoustic environment data at the proposed site was acquired at different depths using a cabled vertical line array (VLA) with four calibrated hydrophones. The sound pressure level (SPL) power spectrum density was estimated based on the fast Fourier transform. This study describes the first broadband SPL measurements for this site at different depths with frequency ranging from 10 kHz to 480 kHz in combination with other information. To understand the SPL caused by this bedload transport, three different pressure sensors with temperature and conductivity were also assembled on the VLA to measure the conditions at the hydrophone deployment depth. The broadband SPL levels at frequency ranges of 3 kHz to 7 kHz as a function of depth were estimated. Only the hydrophone at an average depth of 40 m showed the strong dependence of SPL with distance from the bottom, which was possibly caused by the cobbles shifting on the seabed. Automatic Identification System data were also studied to understand the SPL measurements.

16 TIDAL AND WAVE POWER↗

Optical 14 C Tracing for Biological and Pharmaceutical Applications Using Two-Color Cavity Ringdown Spectroscopy

Laser-based 14 C quantitation has been proposed as a more affordable, higher-throughput, table-top alternative to accelerator mass spectrometry (AMS). Here, we demonstrate the feasibility of a mid-IR 14 C detector based on two-color cavity ringdown spectroscopy (2C-CRDS) for low-level 14 C isotope tracing in biological studies. The 2C-CRDS technique quantifies the sample 14 C content by measuring the 14 CO 2 absorption signals from the combusted samples with mid-IR lasers. With 2C-CRDS, we previously demonstrated the most sensitive and accurate optical measurements of 14 CO 2 . The current detection sensitivity and quantitation accuracy of the instrument, at a few parts per quadrillion (where a quadrillion = 10 15 ) 14 C/C mole fraction, is competitive against AMS. Here, by applying the 2C-CRDS 14 C sensor to two applications relevant to 14 C-labeled biochemical analysis and pharmaceutical studies, we demonstrate sub-fCi level (where 1 fCi = 10 –15 Ci) quantitation of sample 14 C activity, with a minimum sample-size requirement of 3 mg of carbon. The current measurement throughput, ~25 min/sample, is largely limited by the sampling efficiency of the online combustion and CO 2 processing interface to the 2C-CRDS instrument. The possibility of a significantly improved measurement throughput of a few minutes per sample is suggested by the results of a flow-through 14 CO 2 sampling scheme. In conclusion, this improved measurement efficiency, combined with the relatively low cost and compact size of a 2C-CRDS sensor, could potentially revolutionize high-sensitivity 14 C tracing in biological, pharmaceutical, and clinical studies.

60 APPLIED LIFE SCIENCES↗

Technical Advances for Sustainable Remediation: In Situ Monitoring and Climate Resiliency - 18436

Recent advances in sustainable remediation techniques show promise as solutions for contaminant removal in soil and groundwater media. Although passive remediation (or natural attenuation) has gained momentum as an acceptable technique, there are still challenges in regulatory frameworks as well as in public acceptance. Leaving contaminants in subsurface requires increased burden of proof to show that plumes are stable and residual contaminants do not pose a significant health risk. Climate changes and frequent extreme climate events contribute another level of complexity and make it difficult to demonstrate system stability and predict future plume conditions. In this study, we show two coupled approaches to tackle this challenge: (1) in situ groundwater monitoring based on advanced sensor and data analytics technologies (i.e., Big Data), and (2) state-of-art modeling for optimizing monitoring and site closure strategies. In the new monitoring approach, in situ sensors are used to continuously measure the key variables that control contaminant plume mobility and its spatial and temporal distribution (such as pH, redox potential, electrical conductivity, and groundwater level). Coupled with a limited number of groundwater sampling, the data analytics methods - data mining and machine learning - allow us to estimate contaminant concentrations, and also to detect any significant changes associated with the plume mobility. In parallel, the state-of-art numerical flow and reactive transport model - ASCEM software under DOE Office of Environmental Management - provides a physical and mechanistic understanding of the system behavior, and predicts the long-term plume migration for optimizing the monitoring and closure strategies. In particular, we focus on the effects of extreme precipitation or drought on the site closure as well as monitoring strategies. We demonstrate this approach at the Savannah River Site (SRS) F-Area, where groundwater is contaminated by various radionuclides, including uranium, tritium and technetium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection of saliva-range glucose concentrations using organic thin-film transistors

We describe the development of a glucose sensor through direct incorporation of an enzyme (glucose oxidase) into the gate of an organic thin film transistor (OTFT). We show that glucose diffusion is the key determinant of the device response time and present a mechanism of glucose sensing in these devices that involves protonic doping of the transistor channel via enzymatic oxidation of glucose. The integrated OTFT sensor is sensitive across 4 decades of glucose concentration; a range that encompasses both the blood and salivary glucose concentration levels. As such, this work acts as a proof-of-concept for low-cost printed biosensors for salivary glucose.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resonator Stabilization Architecture to Suppress Switching Transient Crosstalk in I-CDM

The ever-increasing sizes of transition-edge sensor (TES) microcalorimeter arrays motivates improved multiplexed readout with large multiplexing factors, low power dissipation, and low levels of crosstalk. Current-summed code division multiplexing (I-CDM) has been proposed as an alternative to flux-summed code division multiplexing (Φ-CDM) because of its lower power dissipation and greater robustness against the failure of individual readout elements. Simulating I-CDM arrays, we find that unswitched circuit components provide a mechanism for crosstalk, the magnitude of which is determined by their inductance. To mitigate this source of crosstalk, we propose a technique called resonator-stabilized I-CDM (RI-CDM), which the simulations predict will reduce crosstalk by an order of magnitude. RI-CDM reads out dc-biased TESs on an amplitude-modulated carrier wave.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗