Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Porous media heat transfer for injection molding

The cooling of injection molded plastic is targeted. Coolant flows into a porous medium disposed within an injection molding component via a porous medium inlet. The porous medium is thermally coupled to a mold cavity configured to receive injected liquid plastic. The porous medium beneficially allows for an increased rate of heat transfer from the injected liquid plastic to the coolant and provides additional structural support over a hollow cooling well. When the temperature of the injected liquid plastic falls below a solidifying temperature threshold, the molded component is ejected and collected.

36 MATERIALS SCIENCE↗

Feasibility of a Deep Direct-Use Geothermal System at the University of Illinois Urbana-Champaign

This study assesses the feasibility of using deep direct-use (DDU) geothermal energy in agricultural research facilities on the University of Illinois at Urbana-Champaign campus to exploit low-temperature sedimentary basins, such as the Illinois Basin. Subsurface components of the system include extraction and injection wells and downhole pumps. Surface equipment includes heat pumps/exchangers, and fluid transport and monitoring systems. Two geologic formations in the region exhibit a potential as sources for geothermal energy, based on pre initial temperatures and flow rates of fluids. The St. Peter and Mt. Simon Sandstones lie at depths of 634 and 1,280 m, respectively. Geocellular modeling is used to characterize the reservoirs. A St. Peter Sandstone model was made for an area south of the campus. Petrophysical and geothermal properties used are based on data from the closest wells penetrating the formations. Characterization of the Mt. Simon Sandstone is in progress and is not discussed here. Extraction and injection flows simulated with different wellbore configurations provide estimates of fluid flow out of and into the reservoir. The models are used to optimize flow rates, bottomhole pressure, and temperature of the produced fluid. Individual wellbore models simulate subsurface heat loss and gain, providing guidance on the optimal type and amount of insulation in the wellbore. Design of the surface facilities will address aspects of fluid delivery, heat exchange, capital operating costs, heat loss, and corrosion. Heat capacity and flow rates are assessed to estimate life-cycle costs and benefits, including the environmental benefits of reducing greenhouse gases and water use and increased energy efficiency. A preliminary analysis of surface configurations for the DDU system (including cascading applications) based on building heat loads is being conducted to identify multiple system designs that will maximize performance, energy efficiency, and cost recovery.

15 GEOTHERMAL ENERGY↗

Experimental, numerical and analytical evaluation of j × B -thrust for fast-liquid-metal-flow divertor systems of nuclear fusion devices

Abstract Divertor systems of fusion devices are exposed to intense heat loads from plasmas, which degrade solid plasma-facing components. Fast liquid metal (LM) flow divertors may be more advantageous for this purpose but have risk of piling due to intense magnetohydrodynamic (MHD) drag. However, severe deceleration of the flow could be countered with the injection of currents that are transverse to external magnetic fields, allowing to thrust the flow with j × B (Lorentz) forces. Given that the injection of currents as an approach to propel LM-divertor flows has remained experimentally understudied, this article focuses on the evaluation of j × B -thrust and finding its drawbacks. j × B -thrust was experimentally tested with free-surface-LM flows, a vertical magnetic field and an externally applied current. Experiments were reviewed with a theoretical model, showing agreement in the trends of theory and experiments. Full 3D-MHD-free-surface-flow simulations were also performed with FreeMHD and confirmed the sensitivity to unstable flow behavior in LM systems when applying external currents. Furthermore, excessive power requirements are expected for the implementation of j × B -thrust at the reactor scale, making these systems inefficient for commercial devices. This paper evidences that the simple operation of a LM-flow divertor with j × B -thrust, without any of the instabilities caused from reactor plasmas or parasitic currents, already presents intrinsic challenges.

Magnetohydrodynamics↗

Observations of Reduced Electron Gyro-scale Fluctuations in National Spherical Torus Experiment H-mode Plasmas with Large E × B Flow Shear

Electron gyro-scale fluctuation measurements in National Spherical Torus Experiment (NSTX) H-mode plasmas with large toroidal rotation reveal fluctuations consistent with electron temper- ature gradient (ETG) turbulence. Large toroidal rotation in NSTX plasmas with neutral beam injection generates E × B flow shear rates comparable to ETG linear growth rates. Enhanced fluctuations occur when the electron temperature gradient is marginally stable with respect to the ETG linear critical gradient. Fluctuation amplitudes decrease when the E × B flow shear rate exceeds ETG linear growth rates. The observations indicate E × B flow shear can be an effective suppression mechanism for ETG turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three Dimensional Solution of Pneumatic Active Control of Forebody Vortex Asymmetry

Pneumatic active control of asymmetric vortical flows around a slender pointed forebody is investigated using the three dimensional solution for the compressible thin-layer Navier-Stokes equation. The computational applications cover the normal and tangential injection control of asymmetric flows around a 5 degree semi-apex angle cone at a 40 degree angle of attack, 1.4 freestream Mach number and 6 x 10(exp 6) freestream Reynolds number (based on the cone length). The effective tangential angle range of 67.5 approaches minus 67.5 degrees is used for both normal and tangential ports of injection. The effective axial length of injection is varied from 0.03 to 0.05. The computational solver uses the implicit, upwind, flux difference splitting finite volume scheme, and the grid consists of 161 x 55 x 65 points in the wrap around, normal and axial directions, respectively. The results show that tangential injection is more effective than normal injection.

Kandil, Osama A.↗

Computational Fluid Dynamics Simulation of Dual Bell Nozzle Film Cooling

Marshall Space Flight Center (MSFC) and Armstrong Flight Research Center (AFRC) are working together to advance the technology readiness level (TRL) of the dual bell nozzle concept. Dual bell nozzles are a form of altitude compensating nozzle that consists of two connecting bell contours. At low altitude the nozzle flows fully in the first, relatively lower area ratio, nozzle. The nozzle flow separates from the wall at the inflection point which joins the two bell contours. This relatively low expansion results in higher nozzle efficiency during the low altitude portion of the launch. As ambient pressure decreases with increasing altitude, the nozzle flow will expand to fill the relatively large area ratio second nozzle. The larger area ratio of the second bell enables higher Isp during the high altitude and vacuum portions of the launch. Despite a long history of theoretical consideration and promise towards improving rocket performance, dual bell nozzles have yet to be developed for practical use and have seen only limited testing. One barrier to use of dual bell nozzles is the lack of control over the nozzle flow transition from the first bell to the second bell during operation. A method that this team is pursuing to enhance the controllability of the nozzle flow transition is manipulation of the film coolant that is injected near the inflection between the two bell contours. Computational fluid dynamics (CFD) analysis is being run to assess the degree of control over nozzle flow transition generated via manipulation of the film injection. A cold flow dual bell nozzle, without film coolant, was tested over a range of simulated altitudes in 2004 in MSFC's nozzle test facility. Both NASA centers have performed a series of simulations of that dual bell to validate their computational models. Those CFD results are compared to the experimental results within this paper. MSFC then proceeded to add film injection to the CFD grid of the dual bell nozzle. A series of nozzle pressure ratios and film coolant flow rates are investigated to determine the effect of the film injection on the nozzle flow transition behavior. The results of this CFD study of a dual bell with film injection are presented in this paper.

Braman, Kalen↗

Aerosol mobility size spectrometer

A device for measuring aerosol size distribution within a sample containing aerosol particles. The device generally includes a spectrometer housing defining an interior chamber and a camera for recording aerosol size streams exiting the chamber. The housing includes an inlet for introducing a flow medium into the chamber in a flow direction, an aerosol injection port adjacent the inlet for introducing a charged aerosol sample into the chamber, a separation section for applying an electric field to the aerosol sample across the flow direction and an outlet opposite the inlet. In the separation section, the aerosol sample becomes entrained in the flow medium and the aerosol particles within the aerosol sample are separated by size into a plurality of aerosol flow streams under the influence of the electric field. The camera is disposed adjacent the housing outlet for optically detecting a relative position of at least one aerosol flow stream exiting the outlet and for optically detecting the number of aerosol particles within the at least one aerosol flow stream.

Wang, Jian↗

Analysis of a six-component, flow-through, strain-gage, force balance used for hypersonic wind tunnel models with scramjet exhaust flow simulation

The thermal effects of simulant gas injection and aerodynamic heating at the model's surface on the measurements of a non-watercooled, flow through balance were investigated. A stainless steel model of a hypersonic air breathing propulsion cruise missile concept (HAPCM-50) was used to evaluate this balance. The tests were conducted in the 20-inch Mach 6 wind tunnel at NASA-Langley. The balance thermal effects were evaluated at freestream Reynolds numbers ranging from .5 to 7 x 10(exp 6) ft and angles of attack between -3.5 to 5 deg at Mach 6. The injection gases considered included cold air, hot air, and a mixture of 50 percent Argon and 50 percent Freon-12. The stagnation temperatures of the cold air, hot air, and Ar-Fr(12) reached 111, 214, and 283 F, respectively within the balance. A bakelite sleeve was inserted into the inner tube of the balance to minimize the thermal effects of these injection gases. Throughout the tests, the normal force, side force, yaw moment, roll moment, and pitching moment balance measurements were unaffected by the balance thermal effects of the injection gases and the wind tunnel flow. However, the axial force (AF) measurement was significantly affected by balance heating. The average zero shifts in the AF measurements were 1.9, 3.8, and 5.9 percent for cold air, hot air, and Ar-Fr(12) injection, respectively. The AF measurements decreased throughout these tests which lasted from 70 to 110 seconds. During the cold air injection tests, the AF measurements were accurate up to at least ten seconds after the model was injected into the wind tunnel test section. For the hot air and Ar-Fr(12) tests, the AF measurements were accurate up to at least five seconds after model injection.

Kniskern, Marc W.↗

Parameters of an electric-discharge generator of iodine atoms for a chemical oxygen-iodine laser

Laser-induced fluorescence is used for measuring the concentration of iodine molecules at the output of an electric-discharge generator of atomic iodine. Methyl iodide CH{sub 3}I is used as the donor of atomic iodine. The fraction of iodine extracted from CH{sub 3}I in the generator is {approx}50%. The optimal operation regimes are found in which 80%-90% of iodine contained in the output flow of the generator was in the atomic state. This fraction decreased during the iodine transport due to recombination and was 20%-30% at the place where iodine was injected into the oxygen flow. The fraction of the discharge power spent for dissociation was {approx}3%. (elements of laser setups)

74 ATOMIC AND MOLECULAR PHYSICS↗

A simulation of the atmospheric cloud physics laboratory to aid in its design and the design of the experiments within the laboratory

Using the finite difference method with overrelaxation, numerical solutions of the steady-state vorticity transport equation were obtained for a continuous flow diffusion chamber of the Hudson-Squires type. The calculation neglected the effects due to temperature, gravity, and saturation. The size and shape of the manifold used to inject the aerosol laden flow were varied to obtain a design which would improve the performance of the chamber from strictly low Reynolds number (less than 20) fluid dynamical considerations.

Winchester, L. W., Jr.↗

Impact of Air Injection on Jet Noise

The objective of this viewgraph presentation is to review the program to determine impact of core fluidic chevrons on noise produced by dual stream jets (i.e., broadband shock noise - supersonic, and mixing noise - subsonic and supersonic). The presentation reviews the sources of jet noise. It shows designs of Generation II Fluidic Chevrons. The injection impacts shock structure and stream disturbances through enhanced mixing. This may impact constructive interference between acoustic sources. The high fan pressures may inhibit mixing produced by core injectors. A fan stream injection may be required for better noise reduction. In future the modification of Gen II nozzles to allow for some azimuthal control: will allow for higher mass flow rates and will allow for shallower injection angles A Flow field study is scheduled for spring, 2008 The conclusions are that injection can reduce well-defined shock noise and injection reduces mixing noise near peak jet noise angle

Henderson, Brenda↗

Modelling the Alfvén eigenmode induced fast-ion flow measured by an imaging neutral particle analyzer

An imaging neutral particle analyzer (INPA) provides energy and radially resolved measurements of the confined fast-ion population ranging from the high-field side to the edge on the midplane of the DIII-D tokamak. In recent experiments, it was used to diagnose fast-ion flow in the INPA-interrogated phase-space driven by multiple, marginally unstable Alfvén eigenmodes (AEs). Here, the key features of this measured fast-ion flow are: (I) a fast-ion flow from q min and the injection energy (81 keV) towards lower energies and plasma periphery.(II) A flow from the same location towards higher energies and the plasma core, (III) a phase-space 'hole' at the injected energy and plasma core and (IV) a pile-up at the plasma core at lower energies (~60 keV). Ad hoc energetic particle diffusivity modelling of TRANSP significantly deviates from the observation. Comparably, a reduced modelling, i.e. a combination of NOVA-K and ASCOT5 code with the measured mode structure and amplitude, generally reproduce some key features of the observed phase-space flow, but largely failed to interpret fast ion depletion near the plasma axis. At last, self-consistent, first-principle multi-phase hybrid simulations that include realistic neutral beam injection and collisions are able to reproduce most features of the time-resolved phase-space flow. During consecutive hybrid phases, an RSAE consistent with the experiment grows and saturates, redistributing the injected fast ions. The resulting synthetic INPA images are in good agreement with the measurement near the injection energy. The simulations track the fast-ion redistribution within the INPA range, confirming that the measured fast-ion flow follows streamlines defined by the intersection of phase-space surfaces of constant magnetic moment μ and constant E' = nE + ωP φ , where n and ω are the instability toroidal mode number and frequency, and E and P φ the ion energy and toroidal canonical momentum. Nonperturbative effects are required to reproduce the depletion of fast ions near the magnetic axis at the injection energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Potential Formation Damage: An Integrated Reservoir Characterization Study of the Naturally Fractured Carbonate Middle Duperow Formation at the Kevin Dome, Montana

In this study, we integrate geologic and engineering data of a naturally fractured carbonate reservoir at the Kevin Dome, Montana. Well test data are correlated with core description, geochemical and lithology study to determine the flow behavior and communication within the injection test interval and to the surrounding area. Based on a dual-continuum geologic model, numerical brine injection simulations are carried out to validate the interpretation results from our well test analytical models and forecast the probability of CO 2 injection success using current reservoir properties. As a result, our well test analytical models as well as lithology/core description suggest that fluid flow may be mainly restricted to the injection interval and the assumption of radial (horizontal) flow may be appropriate. The well test models also indicate that there is potentially formation damage with a positive skin factor although prior to brine injection well tests, well stimulation through acid treatment was performed. Our numerical simulation results appear to confirm this formation damage by showing additional pressure buildup in the injection data during later test periods. To explain this, acid may have dissolved dolomite then dolomite or calcite may have been formed again further into the matrix/fracture system. Another possible explanation is mechanical clogging of the fractures due to acid dissolving dolomite and dislodging fine grains. Our work also predicts that if no additional well stimulation is performed, the project will have a lower probability of successfully injecting 1 million tons of CO 2 into the Middle Duperow formation over 4 years.

42 ENGINEERING↗

Numerical modeling of injection, stress and permeability enhancement during shear stimulation at the Desert Peak Enhanced Geothermal System

Creation of an Enhanced Geothermal System relies on stimulation of fracture permeability through self-propping shear failure that creates a complex fracture network with high surface area for efficient heat transfer. In 2010, shear stimulation was carried out in well 27-15 at Desert Peak geothermal field, Nevada, by injecting cold water at pressure less than the minimum principal stress. An order-of-magnitude improvement in well injectivity was recorded. In this work, we describe a numerical model that accounts for injection-induced stress changes and permeability enhancement during this stimulation. We use the coupled thermo-hydrological–mechanical simulator FEHM to (i) construct a wellbore model for non-steady bottom-hole temperature and pressure conditions during the injection, and (ii) apply these pressures and temperatures as a source term in a numerical model of the stimulation. A Mohr–Coulomb failure criterion and empirical fracture permeability is developed to describe permeability evolution of the fractured rock. The numerical model is calibrated using laboratory measurements of material properties on representative core samples and wellhead records of injection pressure and mass flow during the shear stimulation. The model captures both the absence of stimulation at low wellhead pressure (WHP ≤1.7 and ≤2.4 MPa) as well as the timing and magnitude of injectivity rise at medium WHP (3.1 MPa). Results indicate that thermoelastic effects near the wellbore and the associated non-local stresses further from the well combine to propagate a failure front away from the injection well. Elevated WHP promotes failure, increases the injection rate, and cools the wellbore; however, as the overpressure drops off with distance, thermal and non-local stresses play an ongoing role in promoting shear failure at increasing distance from the well.

15 GEOTHERMAL ENERGY↗

String flash-boiling in gasoline direct injection simulations with transient needle motion

A computational study was performed to investigate the influence of transient needle motion on gasoline direct injection (GDI) internal nozzle flow and near-field sprays. Simulations were conducted with a compressible Eulerian flow solver modeling liquid, vapor, and non-condensable gas phases with a diffuse interface. Variable rate generation and condensation of fuel vapor were captured using the homogeneous relaxation model (HRM). The non-flashing (spray G) and flashing (spray G2) conditions specified by the Engine Combustion Network were modeled using the nominal spray G nozzle geometry and transient needle lift and wobble were based upon ensemble averaged x-ray imaging preformed at Argonne National Lab. The minimum needle lift simulated was 5 μm and dynamic mesh motion was achieved with Laplacian smoothing. The results were qualitatively validated against experimental imaging and the experimental rate of injection profile was captured accurately using pressure boundary conditions and needle motion to actu- ate the injection. Needle wobble was found to have no measurable effect on the flow. Low needle lift is shown to result in vapor generation as fuel rushes past the needle. In conclusion, the internal injector flow is shown to contain many transient and interacting vortices which cause perturbations in the spray angle, fluctuations in the mass flux, and frequently result in string flash-boiling.

33 ADVANCED PROPULSION SYSTEMS↗

Visualization studies of turbulent transition flows in a porous medium

Results are reported for flow-visualization studies of the flow regimes of water passing through a porous medium consisting of cylindrical glass and plexiglas rods arranged in a complex and fixed three-dimensional geometry. The Reynolds number (Re) varied from 50 to 700; the flow was visualized by injecting a 5% potassium permanganate dye solution into the pores and photographing the resulting dye streaklines with both a still camera and a movie camera. The results indicate that four distinct flow regimes exist in the porous medium: (1) Darcy or creeping flow up to Re = 3; (2) steady inertia-dominated laminar flow for Re = 3-150; (3) unsteady transitional laminar flow for Re = 150-250; and (4) fully turbulent flow for Re greater than 250. It is concluded that a laminar wake instability mechanism typical of the external flow about bluff bodies may be responsible for the overall transition from laminar to turbulent flow in porous media.

Bilardo, V. J.↗