Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A liquid xenon imaging telescope for 1-30 MeV gamma-ray astrophysics

A study of the primary scintillation light in liquid xenon excited by 241 Am alpha particles and 207 Bi internal conversion electrons are discussed. The time dependence and the intensity of the light at different field strengths have been measured with a specifically designed chamber, equipped with a CaF sub 2 light transmitting window coupled to a UV sensitive PMT. The time correlation between the fast light signal and the charge signal shows that the scintillation signals produced in liquid xenon by ionizing particles provides an ideal trigger in a Time Projection type LXe detector aiming at full imaging of complex gamma-ray events. Researchers also started Monte Carlo calculations to establish the performance of a LXe imaging telescope for high energy gamma-rays.

Aprile, Elena↗

TITUS: Visualization of Neutrino Events in Liquid Argon Time Projection Chambers

The amount and complexity of data recorded by high energy physics experiments are rapidly growing, and with these grow the difficulties in visualizing such data. To study the physics of neutrinos, a type of elementary particle, scientists use liquid argon time projection chamber (LArTPC) detectors, among other technologies. LArTPCs have a very high spatial resolution and resolve many of the elementary particles that come out of a neutrino interacting within the argon in the detector. Visualizing these neutrino interactions is of fundamental importance to understanding the properties of neutrinos, but also monitoring and checking on the detector conditions and operations. From these ideas, we have developed TITUS, an event display that shows images recorded by these neutrino detectors. TITUS is a piece of software that reads data coming from LArTPC detectors (as well as the corresponding simulation) and allows users to explore such data in multiple ways. TITUS is flexible to enable fast prototyping and customization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The prototype MOSAIC detector

The prototype of the MOSAIC (Mosaicked Optical Self-scanned Array Imaging Camera) system, a photon-counting detector designed for use in the far ultraviolet, is described. MOSAIC has a two-dimensional format of 2400 x 2400 pixels, and is easily expandable. Readout is accomplished electronically via charge-coupled devices, making possible remote observations. Preliminary results of computer simulations of the system are presented.

Weistrop, D.↗

Multiple Waveband Temperature Sensor (MWTS)

This slide presentation reviews the development of Multiple Waveband Temperature Sensor (MWTS). The MWTS project will result in a highly stable, monolithically integrated, high resolution infrared detector array sensor that records registered thermal imagery in four infrared wavebands to infer dynamic temperature profiles on a laser-irradiated ground target. An accurate surface temperature measurement of a target in extreme environments in a non-intrusive manner is required. The development challenge is to: determine optimum wavebands (suitable for target temperatures, nature of the targets and environments) to measure accurate target surface temperature independent of the emissivity, integrate simultaneously readable multiband Quantum Well Infrared Photodetectors (QWIPs) in a single monolithic focal plane array (FPA) sensor and to integrate the hardware/software and system calibration for remote temperature measurements. The charge was therefore to develop and demonstrate a multiband infrared imaging camera with the detectors simultaneously sensitive to multiple distinct color bands for front surface temperature measurements Wavelength ( m) measurements. Amongst the requirements are: that the measurement system will not affect target dynamics or response to the laser irradiation and that the simplest criterion for spectral band selection is to choose those practically feasible spectral bands that create the most contrast between the objects or scenes of interest in the expected environmental conditions. There is in the presentation a review of the modeling and simulation of multi-wave infrared temperature measurement and also a review of the detector development and QWIP capacities.

infrared photodector↗

ASTER TIR subsystem and calibration

Viewgraphs are given on the purpose of TIR, major functions, characteristics and design of various components, and calibration. The major functions are to acquire image data on the earth's surface in thermal infrared wavelength band, using mercury cadmium telluride (HgCdTe) detectors; to convert the obtained image data into the digital data to meet the Common Signal Processor (CSP) interface, and output the signals; pointing function in cross-track direction to get the wide swath of 232 km; and to calibrate the whole TIR with the blackbody on orbit, then the amplifier and subsequent transmission units are calibrated electrically.

Ohmae, Hirokazu↗

Wave-Optics Simulation Framework of Fourier Transform Holography with XMCD

We present a wave-optics simulation framework, implemented within the SRW, for modeling FTH with XMCD contrast. The framework propagates coherent, circularly polarized X-ray wavefronts from an undulator source through the sample and optics to the detector, reconstructing real-space images from the resulting holograms. Three principal extensions are introduced: (i) incorporation of polarization-dependent refractive indices in the sample plane, enabling direct simulation of XMCD contrast, (ii) a memory-efficient wavefront-splitting propagation scheme that treats individual apertures independently and coherently combines their fields at detector, and (iii) an integrated reconstruction module that delivers holographic images within the same framework. Together, these advances establish a versatile tool for quantitative exploration of coherence, aperture geometry, and detector sampling, and for the design and interpretation of XMCD-FTH experiments at synchrotron beamlines.

43 PARTICLE ACCELERATORS↗

Proton imaging of high-energy-density laboratory plasmas

Proton imaging has become a key diagnostic for measuring electromagnetic fields in high-energy-density (HED) laboratory plasmas. Compared to other techniques for diagnosing fields, proton imaging is a measurement that can simultaneously offer high spatial and temporal resolution and the ability to distinguish between electric and magnetic fields without the protons perturbing the plasma of interest. Consequently, proton imaging has been used in a wide range of HED experiments, from inertial-confinement fusion to laboratory astrophysics. An overview is provided on the state of the art of proton imaging, including a discussion of experimental considerations like proton sources and detectors, the theory of proton-imaging analysis, and a survey of experimental results demonstrating the breadth of applications. As a result, topics at the frontiers of proton-imaging development are also described, along with an outlook on the future of the field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Silicon solid/state linear arrays for multispectral high resolution imaging systems

Solid-state, electronically scanned, linear detector arrays are now available which can be used in a pushbroom scan mode imaging system for high-resolution multispectral earth resource survey applications. These arrays provide high performance in the visible to near-IR region. Two performance criteria must be assessed in the choice of a detector array: signal-to-noise ratio and spectral response. Consideration of diffraction limitations shows that optics size cannot be significantly reduced by using very low-noise detectors. The required spectral response for a viable detector array should not have spectral ripples that cause a low-level, but significant, error in the detected effective reflectance of the target.

Thompson, L. L.↗

National Diagnostic Working Group (NDWG) for inertial confinement fusion (ICF)/high-energy density (HED) science: The whole exceeds the sum of its parts

The National Diagnostic Working Group (NDWG) has led the effort to fully exploit the major inertial confinement fusion/high-energy density facilities in the US with the best available diagnostics. These diagnostics provide key data used to falsify early theories for ignition and suggest new theories, recently leading to an experiment that exceeds the Lawson condition required for ignition. The factors contributing to the success of the NDWG, collaboration and scope evolution, and the methods of accomplishment of the NDWG are discussed in this Review. Examples of collaborations in neutron and gamma spectroscopy, x-ray and neutron imaging, x-ray spectroscopy, and deep-ultraviolet Thomson scattering are given. Here, an abbreviated history of the multi-decade collaborations and the present semiformal management framework is given together with the latest National Diagnostic Plan.

47 OTHER INSTRUMENTATION↗

Sub-millimeter wave frequency heterodyne detector system

The present invention relates to sub-millimeter wave frequency heterodyne imaging systems. More specifically, the present invention relates to a sub-millimeter wave frequency heterodyne detector system for imaging the magnitude and phase of transmitted power through or reflected power off of mechanically scanned samples at sub-millimeter wave frequencies.

Siegel, Peter H.↗

Sub-millimeter wave frequency heterodyne detector system

The present invention relates to sub-millimeter wave frequency heterodyne imaging systems. More specifically, the present invention relates to a sub-millimeter wave frequency heterodyne detector system for imaging the magnitude and phase of transmitted power through or reflected power off of mechanically scanned samples at sub-millimeter wave frequencies.

Siegel, Peter H.↗

Digital cartography of Io

A high resolution controlled mosaic of the hemisphere of Io centered on longitude 310 degrees is produced. Digital cartographic techniques were employed. Approximately 80 Voyager 1 clear and blue filter frames were utilized. This mosaic was merged with low-resolution color images. This dataset is compared to the geologic map of this region. Passage of the Voyager spacecraft through the Io plasma torus during acquisition of the highest resolution images exposed the vidicon detectors to ionized radiation, resulting in dark-current buildup on the vidicon. Because the vidicon is scanned from top to bottom, more charge accumulated toward the bottom of the frames, and the additive error increases from top to bottom as a ramp function. This ramp function was removed by using a model. Photometric normalizations were applied using the Minnaert function. An attempt to use Hapke's photometric function revealed that this function does not adequately describe Io's limb darkening at emission angles greater than 80 degrees. In contrast, the Minnaert function accurately describes the limb darkening up to emission angles of about 89 degrees. The improved set of discrete camera angles derived from this effort will be used in conjunction with the space telemetry pointing history file (the IPPS file), corrected on 4 or 12 second intervals to derive a revised time history for the pointing of the Infrared Interferometric Spectrometer (IRIS). For IRIS observations acquired between camera shutterings, the IPPS file can be corrected by linear interpolation, provided that the spacecraft motions were continuous. Image areas corresponding to the fields of view of IRIS spectra acquired between camera shutterings will be extracted from the mosaic to place the IRIS observations and hotspot models into geologic context.

Mcewen, Alfred S.↗

Charge collection efficiency of diamond and silicon sensors irradiated with alpha particles

To evaluate the viability of using semiconductors as sensor materials in a detector for the Associated Particle Imaging technique, the radiation hardness of silicon and diamond diodes to alpha particles has been assessed. Here, the detector lifetimes for both silicon and diamond sensors were measured under the prolonged exposure to alpha particles emitted by an 241 Am source. The silicon detector was exposed to alpha radiation for approximately two months, reaching an accumulated fluence of ~ 1.5 x 10 12 α cm –2 . Additionally, by using a high purity single-crystal diamond with coplanar electrodes operating with full charge collection, the diamond detector response was measured over approximately ten months reaching an accumulated fluence of over 6 x 10 12 α cm –2 cm.

47 OTHER INSTRUMENTATION↗

JPSS-2 VIIRS Day-Night Band Pre-launch Radiometric Calibration and Performance

The first two flight models of the Visible Infrared Imaging Radiometer Suite (VIIRS) instrument continue to operate onboard the Suomi National Polar-orbiting Partnership (S-NPP) and NOAA-20 spacecrafts. The third flight model is set to be launched as one of a complement of instruments onboard the Joint Polar–orbiting Satellite System-2 (JPSS-2) satellite. In addition to its 14 reflective solar bands and 7 thermal emissive bands, VIIRS has a unique Day-Night Band (DNB). The DNB is a panchromatic imager based on CCD detectors, covering a spectral range of about 500 – 900 nm. The DNB is made up of three gain stages, allowing the sensor to operate over a large dynamic range (3×10(−9) - 0.02 W⁄cm(2)/sr). As part of VIIRS pre-launch ground testing, the DNB has been characterized to determine its functionality and performance under a space-like environment. The results are compared against the design specification and to previous VIIRS flight models when applicable. This paper presents a comprehensive summary of the VIIRS DNB prelaunch testing and the results of radiometric and spectral assessments. The expected impact to on-orbit operations and calibrated data products are also discussed.

Infrared Imaging Radiometer Suite (VIIRS)↗

Explosion dynamics of thin flat foils at high current density

This paper presents characteristic features of the explosion of thin flat foils for currents and pulse risetimes ranging from 8 kA at 350 ns to 1000 kA at ~100 ns. Foils made of aluminum, copper, nickel, and titanium with thicknesses of 1–100 µm are tested. Various diagnostics in the optical, UV, and x-ray spectral ranges are used to image the exploding foils from initial breakdown to complete destruction or pinching. It is shown that foil explosion is a complex process that depends on many factors, but features common to all foils are found that do not depend on the parameters of the generators or, accordingly, on the energy deposited in the foil: for example, the breakdown of flat foils under different conditions occurs at the edges of the foil. For the first time, the formation of a precursor over the central part of the foil is shown, which significantly changes the dynamics of the foil explosion.

36 MATERIALS SCIENCE↗

The Clementine instrument complement

The recent successes of the Galileo solid-state imaging (SSI) experiment at the Moon and Gaspra show the utility of multispectral imaging of planetary objects. 'Clementine' is the planetary community's 'code name' for the SDIO (Space Defense Initiative Organization), mission to the Moon and the asteroid Geographos. This mission is designed as a long term stressing test on sensors and space systems developed for SDIO. In the course of this test Clementine will obtain science data using a varied and powerful array of remote sensing instruments which were developed by or for Lawrence Livermore National Laboratory in Livermore, California. Clementine carries five cameras, one for navigation and four for science experiments. In addition, a laser ranger is included which will serve as a laser altimeter. The Clementine cameras cover a wider range of spatial resolutions and wavelength range than did Galileo and are almost ideally suited to mapping of mafic rock types as are present on the Moon and expected at Geographos. Calibration of the cameras will occur at the sensor calibration laboratory at LLNL. In flight calibrations, using standard stars and other standards should improve the stated accuracies. Signal-to-noise ratios (SNRs) include the following noise sources: shot noise, calibration error, digitization noise, readout noise, and frame transfer noise (where applicable). The achieved SNRs are a balance between detector saturation and acceptable image smear. The 'worst' case uses the longest possible integration times.

Lucey, Paul G.↗

Delta Method Application for the Correlation of IR Detector Thermal Parasitic Loads with Statistically Accurate Results

The Linear Etalon Imaging Spectral Array (LEISA) is a cryogenic IR detector that is passively cooled below 110K. LEISA is part of the L’Ralph instrument, which is going on the Lucy mission, with planned flyby’s of the Trojan asteroids around 5.5 AU. One of the primary thermal challenges is to successfully quantify each significant parasitic heat flow value with statistical certainty.Simulation of flight-like thermal environments and correlation of thermal models is an important part of this challenge, which can be critical for thermally sensitive systems such as cryogenic detectors that are passively cooled. It is common practice during TVAC to achieve several thermal balance points and then to correlate several design variables in order to achieve the closest match to all balance points tested. This approach lends itself to high levels of uncertainty in the correlated values due to the cumulative effect of absolute temperature uncertainty and differences between the sensors used for the measurement. Accuracy can be improved with the use of more accurate sensors, by calibrating all sensors with respect to each other, and by using Zero-Q methodologies, all of which add cost and complexity to the test.The Delta Method uses the difference in temperature caused by the changes in the boundary conditions to calculate heat flows and/or thermal resistances across temperature differentials. This eliminates the problem of high uncertainties with absolute temperature measurements, and yields statistically accurate results down to the sensor resolution of 1mK at < 100K, by taking the sensor’s calibration errors out of the equation. During testing, this method relies on parametric variations around an initial balance point, by varying the boundary conditions of the different parasitic heat sources. The Delta Method, as well as its application on the LEISA thermal test, will be discussed in detail.

Daniel G. Bae↗

Characterization of a CMOS camera based film digitization platform for gated x-ray imaging diagnostics at the National Ignition Facility

Hardened gated x-ray detectors use photographic film as the data recording medium due to its low sensitivity to the high-yield neutron environments at the National Ignition Facility (NIF). The photographic film is digitized with a Photometric Data Systems (PDS) microdensitometer, which measures the film’s optical density. The PDS scanner is able to measure a dynamic range of 0–5 OD; however, raster scanning the film is time consuming and maintenance of the instrument is challenging due to legacy technology. Since film usage at NIF is expected to continue in the foreseeable future, a digitization platform that is faster and more maintainable would benefit the NIF’s current and future operations. Here, this work presents the characterization of the digital transitions (DT) atom, a CMOS camera-based digitization platform that records film data in a single image capture very quickly and has widely available user support. The preliminary results suggest that the DT atom is able to reconstruct exposures accurately enough to be a competitive alternative to the PDS Scanner.

47 OTHER INSTRUMENTATION↗