Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-C-209-03: Anti-Scatter Grid-Line Artifact Minimization for Removing the Grid Lines for Three Different Grids Used with a High Resolution CMOS Detector

Purpose: Demonstrate the effectiveness of an anti-scatter grid artifact minimization method by removing the grid-line artifacts for three different grids when used with a high resolution CMOS detector. Method: Three different stationary x-ray grids were used with a high resolution CMOS x-ray detector (Dexela 1207, 75 µm pixels, sensitivity area 11.5cm × 6.5cm) to image a simulated artery block phantom (Nuclear Associates, Stenosis/Aneurysm Artery Block 76–705) combined with a frontal head phantom used as the scattering source. The x-ray parameters were 98kVp, 200mA, and 16ms for all grids. With all the three grids, two images were acquired: the first for a scatter-less flat field including the grid and the second of the object with the grid which may still have some scatter transmission. Because scatter has a low spatial frequency distribution, it was represented by an estimated constant value as an initial approximation and subtracted from the image of the object with grid before dividing by an average frame of the grid flat-field with no scatter. The constant value was iteratively changed to minimize residual grid-line artifact. This artifact minimization process was used for all the three grids. Results: Anti-scatter grid lines artifacts were successfully eliminated in all the three final images taken with the three different grids. The image contrast and CNR were also compared before and after the correction, and also compared with those from the image of the object when no grid was used. The corrected images showed an increase in CNR of approximately 28%, 33% and 25% for the three grids, as compared to the images when no grid at all was used. Conclusion: Anti-scatter grid-artifact minimization works effectively irrespective of the specifications of the grid when it is used with a high spatial resolution detector. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

A model for radar images and its application to adaptive digital filtering of multiplicative noise

Standard image processing techniques which are used to enhance noncoherent optically produced images are not applicable to radar images due to the coherent nature of the radar imaging process. A model for the radar imaging process is derived in this paper and a method for smoothing noisy radar images is also presented. The imaging model shows that the radar image is corrupted by multiplicative noise. The model leads to the functional form of an optimum (minimum MSE) filter for smoothing radar images. By using locally estimated parameter values the filter is made adaptive so that it provides minimum MSE estimates inside homogeneous areas of an image while preserving the edge structure. It is shown that the filter can be easily implemented in the spatial domain and is computationally efficient. The performance of the adaptive filter is compared (qualitatively and quantitatively) with several standard filters using real and simulated radar images.

Frost, V. S.↗

Optical Correlation of Images With Signal-Dependent Noise Using Constrained-Modulation Filter Devices

Images with signal-dependent noise present challenges beyond those of images with additive white or colored signal-independent noise in terms of designing the optimal 4-f correlation filter that maximizes correlation-peak signal-to-noise ratio, or combinations of correlation-peak metrics. Determining the proper design becomes more difficult when the filter is to be implemented on a constrained-modulation spatial light modulator device. The design issues involved for updatable optical filters for images with signal-dependent film-grain noise and speckle noise are examined. It is shown that although design of the optimal linear filter in the Fourier domain is impossible for images with signal-dependent noise, proper nonlinear preprocessing of the images allows the application of previously developed design rules for optimal filters to be implemented on constrained-modulation devices. Thus the nonlinear preprocessing becomes necessary for correlation in optical systems with current spatial light modulator technology. These results are illustrated with computer simulations of images with signal-dependent noise correlated with binary-phase-only filters and ternary-phase-amplitude filters.

Downie, John D.↗

[Overview of the GSFC Effort to Build Microwave Detectors for CMB Polarization]

Filled arrays of bolometers are currently being employed for use in astronomy from the far-infrared through millimeter portion of the electromagnetic spectrum. Because of the large range of wavelengths for which such detectors are applicable, the size of a pixel (p) relative to the wavelength (lambda) will vary according to the specific application of a given available technology. As the pixel size becomes comparable to a wavelength of the absorbed radiation, correlations in the radiation field at the pixel can affect the imaging properties of the system independent of the correlations introduced by the front-end optics. We study the dependence of image fidelity and induced polarization on the size of the pixel by employing a formalism in which diffraction due to the pixel boundary is treated by propagating the second-order statistical correlations of the radiation field through a model optical system. We construct simulated polarized images of square pixels for various ratios of p lambda. For the limit in which few modes are supported by the pixel (p lambda lesssiml), we find that the diffraction due to the pixel edges is non-negligible and hence must be considered along with the telescope diffraction pattern in modeling the ultimate spatial resolution of an imaging system. For the case in which the pixel is over-moded (p lambda ggl), the geometric limit is approached as expected. This technique provides a quantitative approach to understand and optimize the imaging properties of planar detectors in the few-mode limit.

Chuss, David↗

A Synthetic Roman Space Telescope High-Latitude Time-Domain Survey: Supernovae in the Deep Field

NASA will launch the Nancy Grace Roman Space Telescope (hereafter Roman ) in the second half of this decade, which will allow for a generation-defining measurement of dark energy through multiple probes, including Type Ia supernovae (SNe Ia). To impro v e decisions on surv e y strate gy, we hav e created the first simulations of realistic Roman images that include artificial SNe Ia injected as point sources in the images. Our analysis combines work done on Roman simulations for weak gravitational lensing studies as well as catalogue-level simulations of SN Ia samples. We have created a time series of images o v er 2 yr containing ∼1050 SNe Ia, co v ering a 1 deg 2 subarea of a planned 5 deg 2 deep survey. We have released these images publicly for community use along with input catalogues of all injected sources. We create secondary products from these images by generating coadded images and demonstrating reco v ery of transient sources using image subtraction. We perform first-use analyses on these images in order to measure galaxy detection efficiency, point source detection efficiency, and host-galaxy association biases. The simulated images can be found here at https:// roman.ipac.caltech.edu/sims/ SN Survey Image sim.html .

supernovae↗

Performance of today’s dual energy CT and future multi energy CT in virtual non-contrast imaging and in iodine quantification: A simulation study

Purpose: To study the performance of different dual energy computed tomography (DECT) techniques, which are available today, and future multi energy CT (MECT) employing novel photon counting detectors in an image-based material decomposition task. Methods: The material decomposition performance of different energy-resolved CT acquisition techniques is assessed and compared in a simulation study of virtual non-contrast imaging and iodine quantification. The material-specific images are obtained via a statistically optimal image-based material decomposition. A projection-based maximum likelihood approach was used for comparison with the authors’ image-based method. The different dedicated dual energy CT techniques are simulated employing realistic noise models and x-ray spectra. The authors compare dual source DECT with fast kV switching DECT and the dual layer sandwich detector DECT approach. Subsequent scanning and a subtraction method are studied as well. Further, the authors benchmark future MECT with novel photon counting detectors in a dedicated DECT application against the performance of today’s DECT using a realistic model. Additionally, possible dual source concepts employing photon counting detectors are studied. Results: The DECT comparison study shows that dual source DECT has the best performance, followed by the fast kV switching technique and the sandwich detector approach. Comparing DECT with future MECT, the authors found noticeable material image quality improvements for an ideal photon counting detector; however, a realistic detector model with multiple energy bins predicts a performance on the level of dual source DECT at 100 kV/Sn 140 kV. Employing photon counting detectors in dual source concepts can improve the performance again above the level of a single realistic photon counting detector and also above the level of dual source DECT. Conclusions: Substantial differences in the performance of today’s DECT approaches were found for the application of virtual non-contrast and iodine imaging. Future MECT with realistic photon counting detectors currently can only perform comparably to dual source DECT at 100 kV/Sn 140 kV. Dual source concepts with photon counting detectors could be a solution to this problem, promising a better performance.

60 APPLIED LIFE SCIENCES↗

A dust scattered halo in starburst galaxy M82?

The source of the halo about M82 has been under discussion for several years. One explanation for it is the dust model of Solinger, Morrison and Markert in which they propose a diffuse cloud of dust through the M81 group, with M82 traveling through the group holding a denser cloud of dust around it. The feasibility of the dust theory is examined in the X-ray range, using the halo in the X-ray image of M82 taken by the Einstein Observatory. To this end the X-ray cross section for dust is presented, along with the single scattered image of an X-ray source surrounded by a dust cloud; multiply scattered images were simulated with a Monte Carlo program; profiles of the halo along the major and minor axes of M82 are presented. Also presented is an accounting for line spectrographs of M82 that show unusual splitting, using the dust model. The final model proposed for the X-ray image requires dust of radius 50 to 300 A, with density on the order of 10 to the -7th power cu cm, out to a distance of about 9 kpc for some regions.

Rohan, Michael↗

A simulation and diagnostic study of water vapor image dry bands

Limited Area Mesoscale Prediction System model simulation and a special 3-hr radiosonde data set were used to investigate warm bands in the 6.7-micron water-vapor satellite imagery on March 6-7, 1982. It was found that the model reproduces major characteristics of the observed blackbody temperature, T(B), field. A 'development' dry image feature was found to occur in conjunction with an upper level shortwave trough, and an 'advective' feature was found associated with a polar jet streak. Both model and observed T(B) features were associated with vorticity maxima.

Muller, Bradley M.↗

Simulation and analysis of image-based navigation system for rotorcraft low-altitude flight

The automation of helicopter NOE flight entails the modification of nominal trajectories on the basis of the detection and location of obstacles by means of onboard sensors. This process is presently studied using a sequence of images from a passive sensor mounted at the helicopter's center of gravity and oriented with the viewing axis along the rotorcraft's longitudinal body-axis. Three different Kalman filters are used to estimate the location of an object on the ground during the course of various simulated helicopter maneuvers; two of the three filters are found to yield good object location estimates.

Sridhar, Banavar↗

TU-H-CAMPUS-JeP1-04: Deformable Image Registration Performances in Pelvis Patients: Impact of CBCT Image Quality

Purpose: To investigate the accuracy and robustness, against image noise and artifacts (typical of CBCT images), of a commercial algorithm for deformable image registration (DIR), to propagate regions of interest (ROIs) in computational phantoms based on real prostate patient images. Methods: The Anaconda DIR algorithm, implemented in RayStation was tested. Two specific Deformation Vector Fields (DVFs) were applied to the reference data set (CTref) using the ImSimQA software, obtaining two deformed CTs. For each dataset twenty-four different level of noise and/or capping artifacts were applied to simulate CBCT images. DIR was performed between CTref and each deformed CTs and CBCTs. In order to investigate the relationship between image quality parameters and the DIR results (expressed by a logit transform of the Dice Index) a bilinear regression was defined. Results: More than 550 DIR-mapped ROIs were analyzed. The Statistical analysis states that deformation strenght and artifacts were significant prognostic factors of DIR performances, while noise appeared to have a minor role in DIR process as implemented in RayStation as expected by the image similarity metric built in the registration algorithm. Capping artifacts reveals a determinant role for the accuracy of DIR results. Two optimal values for capping artifacts were found to obtain acceptable DIR results (DICE> 075/ 0.85). Various clinical CBCT acquisition protocol were reported to evaluate the significance of the study. Conclusion: This work illustrates the impact of image quality on DIR performance. Clinical issues like Adaptive Radiation Therapy (ART) and Dose Accumulation need accurate and robust DIR software. The RayStation DIR algorithm resulted robust against noise, but sensitive to image artifacts. This result highlights the need of robustness quality assurance against image noise and artifacts in the commissioning of a DIR commercial system and underlines the importance to adopt optimized protocols for CBCT image acquisitions in ART clinical implementation.

60 APPLIED LIFE SCIENCES↗

Use of AVIRIS data to the definition of optimised specifications for land applications with future spaceborne imaging spectrometers

Recent experience with airborne imaging spectrometers demonstrated the advantages of narrow band sensors over broad band scanners for characterizing the nature, extent, and physical status of typical land surfaces. Information on key spectral features associated with various land surfaces can be obtained from the data of such instruments, which can be used to simulate spaceborne imaging spectrometer data and to assess their information content if comprehensive underpinning is provided by ground data. The collection of such information was an issue of airborne imaging spectrometer campaigns like the NASA MAC-Europe 1991. Airborne and ground data obtained from different test sites in Europe are utilized for a comparative analysis of the spectral signatures of various land surfaces (vegetation, bare soils and rocks, and mixed soil/rock-vegetation) as seen from different imaging spectrometers like Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), GERIS 63 band scanner, and CASI. The following items are discussed: (1) the significance of different spectral regions within the wavelength interval between 0.4 m and 2.5 m for the differentiation of different land units; (2) recommendations on the optimum band selection and band-widths to be used for the application of future satellite-based imaging spectrometers for land applications; (3) the boundaries for the detection of plant features in mixed-soil plant spectra and the influence of different soil properties on the mixture of the spectra; (4) recommendations on the optimum spatial resolution and recording dates for the discrimination of spectral features of various surface types; and (5) evaluation of different data compressing techniques for the optimum extraction of spectral information from imaging spectrometry data.

Bodechtel, J.↗

A synthetic Roman Space Telescope High-Latitude Time-Domain Survey: supernovae in the deep field

ABSTRACT NASA will launch the Nancy Grace Roman Space Telescope (hereafter Roman) in the second half of this decade, which will allow for a generation-defining measurement of dark energy through multiple probes, including Type Ia supernovae (SNe Ia). To improve decisions on survey strategy, we have created the first simulations of realistic Roman images that include artificial SNe Ia injected as point sources in the images. Our analysis combines work done on Roman simulations for weak gravitational lensing studies as well as catalogue-level simulations of SN Ia samples. We have created a time series of images over 2 yr containing ∼1050 SNe Ia, covering a 1 deg2 subarea of a planned 5 deg2 deep survey. We have released these images publicly for community use along with input catalogues of all injected sources. We create secondary products from these images by generating coadded images and demonstrating recovery of transient sources using image subtraction. We perform first-use analyses on these images in order to measure galaxy detection efficiency, point source detection efficiency, and host-galaxy association biases. The simulated images can be found here at https://roman.ipac.caltech.edu/sims/SN_Survey_Image_sim.html.

Astronomy & Astrophysics↗

Recent advances and applications of deep learning methods in materials science

Deep learning (DL) is one of the fastest-growing topics in materials data science, with rapidly emerging applications spanning atomistic, image-based, spectral, and textual data modalities. DL allows analysis of unstructured data and automated identification of features. The recent development of large materials databases has fueled the application of DL methods in atomistic prediction in particular. In contrast, advances in image and spectral data have largely leveraged synthetic data enabled by high-quality forward models as well as by generative unsupervised DL methods. In this article, we present a high-level overview of deep learning methods followed by a detailed discussion of recent developments of deep learning in atomistic simulation, materials imaging, spectral analysis, and natural language processing. For each modality we discuss applications involving both theoretical and experimental data, typical modeling approaches with their strengths and limitations, and relevant publicly available software and datasets. We conclude the review with a discussion of recent cross-cutting work related to uncertainty quantification in this field and a brief perspective on limitations, challenges, and potential growth areas for DL methods in materials science.

36 MATERIALS SCIENCE↗

Piloted Simulation Investigation of a Supersonic Transport Configuration (LaRC.4)

This report contains a description of the test facilities and software utilized during a joint NASA/aerospace industry study of improved control laws and desired inceptor characteristics for a candidate supersonic transport air-craft design. Details concerning the characteristics of the simulation cockpit, image generator and display systems, and motion platform are described. Depictions of the various display formats are included. The test schedule, session log, and flight cards describing the maneuvers performed is included. A brief summary of high-lights of the study is given. Modifications made to the industry-provided simulation model are described. This report is intended to serve as a reference document for industry researchers.

Jackson, E. Bruce↗

Rehybridization dynamics into the pericyclic minimum of an electrocyclic reaction imaged in real-time

Abstract Electrocyclic reactions are characterized by the concerted formation and cleavage of both σ and π bonds through a cyclic structure. This structure is known as a pericyclic transition state for thermal reactions and a pericyclic minimum in the excited state for photochemical reactions. However, the structure of the pericyclic geometry has yet to be observed experimentally. We use a combination of ultrafast electron diffraction and excited state wavepacket simulations to image structural dynamics through the pericyclic minimum of a photochemical electrocyclic ring-opening reaction in the molecule α-terpinene. The structural motion into the pericyclic minimum is dominated by rehybridization of two carbon atoms, which is required for the transformation from two to three conjugated π bonds. The σ bond dissociation largely happens after internal conversion from the pericyclic minimum to the electronic ground state. These findings may be transferrable to electrocyclic reactions in general.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-E-I-12: Flexible Geometry Computed Tomography

Purpose: The concept separates the mechanical connection between the radiation source and detector. This design allows the trajectory and orientation of the radiation source/detector to be customized to the object that is being imaged. This is in contrast to the formulaic rotation-translation image acquisition of conventional computed tomography(CT).Background/significance:CT devices that image a full range of: anatomy, patient populations, and imaging procedures are large. The root cause of the expanding size of comprehensive CT is due to the commitment to helical geometry that is hardwired into the image reconstruction. FGCT extends the application of alternative reconstruction techniques, i.e. tomosynthesis, by separating the two main components— radiation source and detector— and allow for 6 degrees of freedom motion for radiation source, detector, or both. The image acquisition geometry is then tailored to how the patient/object is positioned. This provides greater flexibility on the position and location that the patient/object is being imaged. Additionally, removing the need of a rotating gantry reduces the footprint so that CT is more mobile and more available to move to where the patient/object is at, instead of the other way around. Methods: As proof-of-principle, a reconstruction algorithm is designed to produce FGCT images. Using simulated detector data, voxels intersecting a line drawn between the radiation source and an individual detector are traced and modified using the detector signal. The detector signal is modified to compensate for changes in the source to detector distance. Adjacent voxels are modified in proportion to the detector signal, providing a simple image filter. Results: Image-quality from the proposed FGCT reconstruction technique is proving to be a challenge, producing hardily recognizable images from limited projections angles. Conclusion: Preliminary assessment of the reconstruction technique demonstrates the inevitable tradeoff of producing meaningful image-quality verses the practicality of how to obtain sufficient image data.

60 APPLIED LIFE SCIENCES↗

REFLECTED LIGHT CURVES, SPHERICAL AND BOND ALBEDOS OF JUPITER- AND SATURN-LIKE EXOPLANETS

Reflected light curves observed for exoplanets indicate that a few of them host bright clouds. We estimate how the light curve and total stellar heating of a planet depends on forward and backward scattering in the clouds based on Pioneer and Cassini spacecraft images of Jupiter and Saturn. We fit analytical functions to the local reflected brightnesses of Jupiter and Saturn depending on the planet’s phase. These observations cover broadbands at 0.59–0.72 and 0.39–0.5 μ m, and narrowbands at 0.938 (atmospheric window), 0.889 (CH4 absorption band), and 0.24–0.28 μ m. We simulate the images of the planets with a ray-tracing model, and disk-integrate them to produce the full-orbit light curves. For Jupiter, we also fit the modeled light curves to the observed full-disk brightness. We derive spherical albedos for Jupiter and Saturn, and for planets with Lambertian and Rayleigh-scattering atmospheres. Jupiter-like atmospheres can produce light curves that are a factor of two fainter at half-phase than the Lambertian planet, given the same geometric albedo at transit. The spherical albedo is typically lower than for a Lambertian planet by up to a factor of ∼1.5. The Lambertian assumption will underestimate the absorption of the stellar light and the equilibrium temperature of the planetary atmosphere. We also compare our light curves with the light curves of solid bodies: the moons Enceladus and Callisto. Their strong backscattering peak within a few degrees of opposition (secondary eclipse) can lead to an even stronger underestimate of the stellar heating.

79 ASTRONOMY AND ASTROPHYSICS↗