Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Imaging electron motion in graphene

A cooled scanning probe microscope (SPM) is an ideal tool to image electronic motion in graphene: the SPM tip acts as a scanning gate, which interacts with the electron gas below. We introduce the technique using our group's previous work on imaging electron flow from a quantum point contact in a GaAs 2DEG and tuning an InAs quantum dot in an InAs/InP nanowire. Carriers in graphene have very different characteristics: electrons and holes travel at a constant speed with no bandgap, and they pass through potential barriers via Klein tunneling. In this paper, we review the extension of SPM imaging techniques to graphene. We image the cyclotron orbits passing between two narrow contacts in a single-atomic-layer graphene device in a perpendicular magnetic field. Magnetic focusing produces a peak in transmission between the contacts when the cyclotron diameter is equal to the contact spacing. The charged SPM tip deflects electrons passing from one contact to the other, changing the transmission when it interrupts the flow. By displaying the change in transmission as the tip is raster scanned above the sample, an image of flow is obtained. In addition, we have developed a complementary technique to image electronic charge using a cooled scanning capacitance microscope (SCM) that uses a sensitive charge preamplifier near the SPM tip to achieve a charge noise level 0.13 e Hz -1/2 with high spatial resolution 100 nm. The cooled SPM and SCM can be used to probe the motion of electrons on the nanoscale in graphene devices.

36 MATERIALS SCIENCE↗

A Window into Longer Lasting Batteries

There’s a new tool in the push to engineer rechargeable batteries that last longer and charge more quickly. An X-ray microscopy technique recently developed at Berkeley Lab has given scientists the ability to image nanoscale changes inside lithium-ion battery particles as they charge and discharge. The real-time images provide a new way to learn how batteries work, and how to improve them. The method was developed at Berkeley Lab’s Advanced Light Source, a DOE Office of Science User Facility, by a team of researchers from the Department of Energy’s SLAC National Accelerator Laboratory, Berkeley Lab, Stanford University, and other institutions.

25 ENERGY STORAGE↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

Delta-doped CCD's as low-energy particle detectors and imagers

The back surface of a thinned charged-coupled device (CCD) is treated to eliminate the backside potential well that appears in a conventional thinned CCD during backside illumination. The backside of the CCD includes a delta layer of high-concentration dopant confined to less than one monolayer of the crystal semiconductor. The thinned, delta-doped CCD is used to detect very low-energy particles that penetrate less than 1.0 nm into the CCD, including electrons having energies less than 1000 eV and protons having energies less than 10 keV.

Nikzad, Shouleh↗

Thrust Measurements in Ballistic Pendulum Ablative Laser Propulsion Experiments

This paper describes a setup for thrust measurement in ablative laser propulsion experiments, based on a simple ballistic pendulum associated to an imaging system, which is being assembled at IEAv. A light aluminium pendulum holding samples is placed inside a 100 liters vacuum chamber with two optical windows: the first (in ZnSe) for the laser beam and the second (in fused quartz) for the pendulum visualization. A TEA-CO{sub 2} laser beam is focused to the samples providing ablation and transferring linear moment to the pendulum as a whole. A CCD video camera captures the oscillatory movement of the pendulum and the its trajectory is obtained by image processing. By fitting the trajectory of the pendulum to a dumped sinusoidal curve is possible to obtain the amplitude of the movement which is directly related to the momentum transfered to the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-crystal oxoborate (Pb{sub 3}O){sub 2}(BO{sub 3}){sub 2}WO{sub 4}: Growth and characterization

Highlights: ► (Pb{sub 3}O){sub 2}(BO{sub 3}){sub 2}WO{sub 4}, has been prepared by solid-state reaction methods below 620 °C. ► Single-crystal XRD analysis showed that it crystallizes in the orthorhombic group. ► The crystal structure is composed of one-dimensional 1/∞ [Pb{sub 3}O]{sup 4+} chains. ► BO{sub 3} and WO{sub 4} groups are located around the chains to hold them via Pb-O bonds. ► The IR spectra further confirmed the presence of BO{sub 3} groups. -- Abstract: An oxoborate, (Pb{sub 3}O){sub 2}(BO{sub 3}){sub 2}WO{sub 4}, has been prepared by solid-state reaction methods below 620 °C. Single-crystal XRD analysis shows that it crystallizes in the orthorhombic group Cmcm with a = 18.480(4) Å, b = 6.3567(13) Å, c = 11.672(2) Å, Z = 4. The crystal structure is composed of one-dimensional 1/∞ [Pb{sub 3}O]{sup 4+} chains formed by corner-sharing OPb{sub 4} tetrahedra. BO{sub 3} and WO{sub 4} groups are located around the chains to hold them together via Pb-O bonds. The IR spectra further confirmed the presence of BO{sub 3} groups. Furthermore we have performed theoretical calculations by employing the all-electron full potential linearized augmented plane wave (FP-LAPW) method to solve the Kohn Sham equations. Starting from our XRD data we have optimized the atomic positions by minimizing the forces. These are used to calculate the electronic band structure, the atomic site-decomposed density of states, electron charge density and the chemical bonding features. The calculated electronic band structure and densities of states suggest that this oxoborate possesses a wide energy band gap. The valence band maxima and the conduction band minima are located at Y point in the Brillouin zone resulting in a direct energy band gap of 2.3 eV using the local density approximation and 2.6 eV for the Engel–Vosko generalized gradient approximation. This compares well with our experimentally measured energy band gap of 2.9 eV. From our calculated electron charge density distribution, we obtain an image of the electron clouds that surround the molecules in the unit cell of the crystal. The chemical bonding features were analyzed and the substantial covalent interactions are observed between Pb and O, B and O and W and O atoms.

36 MATERIALS SCIENCE↗

SPECKLE INTERFEROMETRY AT THE U.S. NAVAL OBSERVATORY. XV

Results of 2433 intensified CCD observations of double stars, made with the 26 inch refractor of the U.S. Naval Observatory, are presented. Each observation of a system represents a combination of over 2000 short-exposure images. These observations are averaged into 1013 mean relative positions and range in separation from 0.''96 to 58.''05, with a mean separation of 13.''50. This paper is the 15th in the series of papers and covers the period 2008 January 3 through 2008 December 21.

79 ASTRONOMY AND ASTROPHYSICS↗

Application of a silicon photodiode array for solar edge tracking in the Halogen Occultation Experiment

The optical and electronic design of the Halogen Occultation Experiment (HALOE) elevation sunsensor is described. This system uses a Galilean telescope to form a solar image on a linear silicon photodiode array. The array is a self-scanned, monolithic charge coupled device. The addresses of both solar edges imaged on the array are used by the control/pointing system to scan the HALOE science instantaneous-field-of-view (IFOV) across the vertical solar diameter during instrument calibration, and then maintain the science IFOV four arcmin below the top edge during the science data occultation event. Vertical resolution of 16 arcsec and a radiometric dynamic range of 100 are achieved at the 0.7 micrometer operating wavelength. The design provides for loss of individual photodiode elements without loss of angular tracking capability. The HALOE instrument is a gas correlation radiometer that is now being developed by NASA Langley Research Center for the Upper Atmospheric Research Satellite.

Mauldin, L. E., III↗

Far Ultraviolet Imaging from the Image Spacecraft: Wideband FUV Imaging - 2

The Far Ultraviolet Wideband Imaging Camera (WIC) complements the magnetospheric images taken by the IMAGE satellite instruments with simultaneous global maps of the terrestrial aurora. Thus, a primary requirement of WIC is to image the total intensity of the aurora in wavelength regions most representative of the aurora] source and least contaminated by dayglow, have sufficient field of view to cover the entire polar region from spacecraft apogee and have resolution that is Sufficient to resolve auroras on a scale of 1 to 2 latitude degrees, The instrument is sensitive in the spectral region from 140- 190 nm. The WIC is mounted on the rotating, IMAGE spacecraft viewing radially outward and has a field of view of 17 deg in the direction parallel to the spacecraft spin axis. Its field of view is 30 deg in the direction perpendicular to the spin axis, although only a 17 deg x 17 deg image of the Earth is recorded. The optics was an all-reflective, inverted Cassegrain Burch camera using concentric optics with a small convex primary and a large concave secondary mirror. The mirrors were coated by a special multi-layer coating, which has low reflectivity in the visible and near UV region, The detector consists of a MCP-Intensified CCD. The MCP is curved to accommodate the focal surface of the concentric optics. Tile phosphor of the image intensifier is deposited on a concave fiberoptic window, which is then Coupled to the CCD with a fiberoptic taper. The camera head operates in a fast frame transfer mode with the CCD being read approximately 30 full frames (512 by 256 pixel) per second with an exposure time of 0.033 s. The image motion (file to the satellite spin is minimal during such a short exposure. Each image is electronically distortion corrected using the look up table scheme. An offset is added to each memory address that is proportional to the image shift due to satellite rotation, and the charge signal is digitally summed in memory. On orbit, approximately 300 frames will be added to produce one WIC image in memory. The advantage of the electronic motion compensation and distortion correction is that it is extremely flexible, permitting several kinds of corrections including motions parallel and perpendicular to the predicted axis of rotation. File instrument was calibrated by applying ultraviolet light through a vacuum monochromator and measuring the absolute responsivity of the instrument. To obtain the data for the distortion look up table the camera was turned through various angles and the input angles corresponding to a pixel matrix were recorded. It was found that the spectral response peaked at 150 nm and fell off in either direction. The equivalent aperture of the camera, including mirror reflectivities and effective photocathode quantum efficiency, is about 0.04 sq cm. Thus, a 100 Rayleigh LBH aurora is expected to produce 23 equivalent counts per pixel per 10 s exposure at the peak of instrument response.

Mende, S. B.↗

X-ray phase contrast imaging: Transmission functions separable in cylindrical coordinates

A Fresnel-Kirchhoff integral can be used to calculate x-ray phase contrast images when the transmission function is known. Here expressions for image intensity are derived for objects with axial symmetry for an x-ray source with non-vanishing dimensions. An expression for the image intensity is given for an x-ray source whose intensity distribution is described by a Gaussian function, from which an expression for the limiting case of a point source of radiation is found. The expressions for image intensity are evaluated for cases where the magnification is substantially greater than one, as would be employed in biological imaging. Experiments using a microfocus x-ray tube and charge coupled device camera are reported to determine the capability of the method for imaging small spherical objects, such as gold particles, which might find application as contrast agents in biomedical imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mapping charge excitations in generalized Wigner crystals

Transition metal dichalcogenide-based moiré superlattices exhibit strong electron-electron correlations, thus giving rise to strongly correlated quantum phenomena such as generalized Wigner crystal states. Evidence of Wigner crystals in transition metal dichalcogenide moire superlattices has been widely reported from various optical spectroscopy and electrical conductivity measurements, while their microscopic nature has been limited to the basic lattice structure. Theoretical studies predict that unusual quasiparticle excitations across the correlated gap between upper and lower Hubbard bands can arise due to long-range Coulomb interactions in generalized Wigner crystal states. However, the microscopic proof of such quasiparticle excitations is challenging because of the low excitation energy of the Wigner crystal. Here, in this study, we describe a scanning single-electron charging spectroscopy technique with nanometre spatial resolution and single-electron charge resolution that enables us to directly image electron and hole wavefunctions and to determine the thermodynamic gap of generalized Wigner crystal states in twisted WS 2 moiré heterostructures. High-resolution scanning single-electron charging spectroscopy combines scanning tunnelling microscopy with a monolayer graphene sensing layer, thus enabling the generation of individual electron and hole quasiparticles in generalized Wigner crystals. We show that electron and hole quasiparticles have complementary wavefunction distributions and that thermodynamic gaps of ~50 meV exist for the 1/3 and 2/3 generalized Wigner crystal states in twisted WS 2 .

36 MATERIALS SCIENCE↗

Characterization and correction of charge-induced pixel shifts in DECam

Interaction of charges in CCDs with the already accumulated charge distribution causes both a flux dependence of the point-spread function (an increase of observed size with flux, also known as the brighter/fatter effect) and pixel-to-pixel correlations of the Poissonian noise in flat fields. We describe these effects in the Dark Energy Camera (DECam) with charge dependent shifts of effective pixel borders, i.e. the Antilogus et al. (2014) model, which we fit to measurements of flat-field Poissonian noise correlations. The latter fall off approximately as a power-law r -2.5 with pixel separation r, are isotropic except for an asymmetry in the direct neighbors along rows and columns, are stable in time, and are weakly dependent on wavelength. They show variations from chip to chip at the 20% level that correlate with the silicon resistivity. The charge shifts predicted by the model cause biased shape measurements, primarily due to their effect on bright stars, at levels exceeding weak lensing science requirements. We measure the flux dependence of star images and show that the effect can be mitigated by applying the reverse charge shifts at the pixel level during image processing. Differences in stellar size, however, remain significant due to residuals at larger distance from the centroid.

79 ASTRONOMY AND ASTROPHYSICS↗

Future of Electron Scattering and Diffraction

The ability to correlate the atomic- and nanoscale-structure of condensed matter with physical properties (e.g., mechanical, electrical, catalytic, and optical) and functionality forms the core of many disciplines. Directing and controlling materials at the quantum-, atomic-, and molecular-levels creates enormous challenges and opportunities across a wide spectrum of critical technologies, including those involving the generation and use of energy. The workshop identified next generation electron scattering and diffraction instruments that are uniquely positioned to address these grand challenges. The workshop participants identified four key areas where the next generation of such instrumentation would have major impact: A – Multidimensional Visualization of Real Materials B – Atomic-scale Molecular Processes C – Photonic Control of Emergence in Quantum Materials D – Evolving Interfaces, Nucleation, and Mass Transport Real materials are comprised of complex three-dimensional arrangements of atoms and defects that directly determine their potential for energy applications. Understanding real materials requires new capabilities for three-dimensional atomic scale tomography and spectroscopy of atomic and electronic structures with unprecedented sensitivity, and with simultaneous spatial and energy resolution. Many molecules are able to selectively and efficiently convert sunlight into other forms of energy, like heat and electric current, or store it in altered chemical bonds. Understanding and controlling such process at the atomic scale require unprecedented time resolution. One of the grand challenges in condensed matter physics is to understand, and ultimately control, emergent phenomena in novel quantum materials that necessitate developing a new generation of instruments that probe the interplay among spin, charge, orbital, and lattice degrees of freedom with intrinsic time- and length-scale resolutions. Molecules and soft matter require imaging and spectroscopy with high spatial resolution without damaging their structure. The strong interaction of electrons with matter allows high-energy electron pulses to gather structural information before a sample is damaged. Electron ScatteringImaging, diffraction, and spectroscopy are the fundamental capabilities of electron-scattering instruments. The DOE BES-funded TEAM (Transmission Electron Aberration-corrected Microscope) project achieved unprecedented sub-atomic spatial resolution in imaging through aberration-corrected transmission electron microscopy. To further advance electron scattering techniques that directly enable groundbreaking science, instrumentation must advance beyond traditional two-dimensional imaging. Advances in temporal resolution, recording the full phase and energy spaces, and improved spatial resolution constitute a new frontier in electron microscopy, and will directly address the BES Grand Challenges, such as to “control the emergent properties that arise from the complex correlations of atomic and electronic constituents” and the “hidden states” “very far away from equilibrium”. Ultrafast methods, such as the pump-probe approach, enable pathways toward understanding, and ultimately controlling, the chemical dynamics of molecular systems and the evolution of complexity in mesoscale and nanoscale systems. Central to understanding how to synthesize and exploit functional materials is having the ability to apply external stimuli (such as heat, light, a reactive flux, and an electrical bias) and to observe the resulting dynamic process in situ and in operando, and under the appropriate environment (e.g., not limited to UHV conditions). To enable revolutionary advances in electron scattering and science, the participants of the workshop recommended three major new instrumental developments: A. Atomic-Resolution Multi-Dimensional Transmission Electron Microscope: This instrument would provide quantitative information over the entire real space, momentum space, and energy space for visualizing dopants, interstitials, and light elements; for imaging localized vibrational modes and the motion of charged particles and vacancies; for correlating lattice, spin, orbital, and charge; and for determining the structure and molecular chemistry of organic and soft matter. The instrument will be uniquely suited to answer fundamental questions in condensed matter physics that require understanding the physical and electronic structure at the atomic scale. Key developments include stable cryogenic capabilities that will allow access to emergent electronic phases, as well as hard/soft interfaces and radiation- sensitive materials. B. Ultrafast Electron Diffraction and Microscopy Instrument: This instrument would be capable of nano-diffraction with 10 fs temporal resolution in stroboscopic mode, and better than 100 fs temporal resolution in single shot mode. The instrument would also achieve single- shot real-space imaging with a spatial/temporal resolution of 10 nm/10 ps, representing a thousand fold improvement over current microscopes. Such a capability would be complementary to x-ray free electron lasers due to the difference in the nature of electron and x-ray scattering, enabling space-time mapping of lattice vibrations and energy transport, facilitating the understanding of molecular dynamics of chemical reactions, the photonic control of emergence in quantum materials, and the dynamics of mesoscopic materials. C. Lab-In-Gap Dynamic Microscope: This instrument would enable quantitative measurements of materials structure, composition, and bonding evolution in technologically relevant environments, including liquids, gases and plasmas, thereby assuring the understanding of structure function relationship at the atomic scale with up to nanosecond temporal resolution. This instrument would employ a versatile, modular sample stage and holder geometry to allow the multi-modal (e.g., optical, thermal, mechanical, electrical, and electrochemical) probing of materials’ functionality in situ and in operando. The electron optics encompasses a pole piece that can accommodate the new stage, differential pumping, detectors, aberration correctors, and other electron optical elements for measurement of materials dynamics. To realize the proposed instruments in a timely fashion, BES should aggressively support research and development of complementary and enabling instruments, including new electron sources, advanced electron optics, new tunable specimen pumps and sample stages, and new detectors. The proposed instruments would have transformative impact on physics, chemistry, materials science, engineering

43 PARTICLE ACCELERATORS↗

Higgs and Z assisted stop searches at hadron colliders

Current searches for the light top squark (stop) mostly focus on the decay channels of \( \tilde{t}\to t{\chi}_1^0 \) or \( \tilde{t}\to b{\chi}_1^{\pm}\to bW{\chi}_1^0 \) , leading to Open image in new window final states for stop pair productions at the LHC. However, in supersymmetric scenarios with light neutralinos and charginos other than the neutralino lightest supersymmetric particle (LSP), more than one decay mode of the stop could be dominant. While those new decay modes could significantly weaken the current stop search limits at the LHC, they also offer alternative discovery channels for stop searches. In this paper, we studied the scenario with light Higgsino next-to-LSPs (NLSPs) and Bino LSP. The light stop decays primarily via \( {\tilde{t}}_1\to t{\chi}_2^0/{\chi}_3^0 \) , with the neutralinos subsequent decaying to a Z boson or a Higgs boson: χ 2° /χ 3 ° → χ 1 ° h/Z. Pair production of light stops at the LHC leads to final states of Open image in new window or Open image in new window . We consider three signal regions: one charged lepton (1ℓ), two opposite sign charged leptons (2 OS ℓ) and at least three charged leptons (≥3ℓ). We found that the 1ℓ signal region of channel Open image in new window has the best reach sensitivity for light stop searches. For 14 TeV LHC with 300 fb -1 integrated luminosity, a stop mass up to 900 GeV can be discovered at 5σ significance, or up to 1050 GeV can be excluded at 95% C.L. Combining all three decay channels for 1ℓ signal region extends the reach for about 100–150 GeV. We also studied the stop reach at the 100 TeV pp collider with 3 ab -1 luminosity, with discovery and exclusion reach being 6 TeV and 7 TeV, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

NASA Tech Briefs, March 2009

Topics covered include: Improved Instrument for Detecting Water and Ice in Soil; Real-Time Detection of Dust Devils from Pressure Readings; Determining Surface Roughness in Urban Areas Using Lidar Data; DSN Data Visualization Suite; Hamming and Accumulator Codes Concatenated with MPSK or QAM; Wide-Angle-Scanning Reflectarray Antennas Actuated by MEMS; Biasable Subharmonic Membrane Mixer for 520 to 600 GHz; Hardware Implementation of Serially Concatenated PPM Decoder; Symbolic Processing Combined with Model-Based Reasoning; Presentation Extensions of the SOAP; Spreadsheets for Analyzing and Optimizing Space Missions; Processing Ocean Images to Detect Large Drift Nets; Alternative Packaging for Back-Illuminated Imagers; Diamond Machining of an Off-Axis Biconic Aspherical Mirror; Laser Ablation Increases PEM/Catalyst Interfacial Area; Damage Detection and Self-Repair in Inflatable/Deployable Structures; Polyimide/Glass Composite High-Temperature Insulation; Nanocomposite Strain Gauges Having Small TCRs; Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling; Modeling Unsteady Cavitation and Dynamic Loads in Turbopumps; Continuous-Flow System Produces Medical-Grade Water; Discrimination of Spore-Forming Bacilli Using spoIVA; nBn Infrared Detector Containing Graded Absorption Layer; Atomic References for Measuring Small Accelerations; Ultra-Broad-Band Optical Parametric Amplifier or Oscillator; Particle-Image Velocimeter Having Large Depth of Field; Enhancing SERS by Means of Supramolecular Charge Transfer; Improving 3D Wavelet-Based Compression of Hyperspectral Images; Improved Signal Chains for Readout of CMOS Imagers; SOI CMOS Imager with Suppression of Cross-Talk; Error-Rate Bounds for Coded PPM on a Poisson Channel; Biomorphic Multi-Agent Architecture for Persistent Computing; and Using Covariance Analysis to Assess Pointing Performance.

Source record↗

800 x 800 charge-coupled device /CCD/ camera for the Galileo Jupiter Orbiter mission

During January 1982 the NASA space transportation system will launch a Galileo spacecraft composed of an orbiting bus and an atmospheric entry probe to arrive at the planet Jupiter in July 1985. A prime element of the orbiter's scientific instrument payload will be a new generation slow-scan planetary imaging system based on a newly developed 800 x 800 charge-coupled device (CCD) image sensor. Following Jupiter orbit insertion, the single, narrow-angle, CCD camera, designated the Solid State Imaging (SSI) Subsystem, will operate for 20 months as the orbiter makes repeated encounters with Jupiter and its Galilean Satellites. During this period the SSI will acquire 40,000 images of Jupiter's atmosphere and the surfaces of the Galilean Satellites. This paper describes the SSI, its operational modes, and science objectives.

Clary, M. C.↗

Mars Science Laboratory Engineering Cameras

NASA's Mars Science Laboratory (MSL) Rover, which launched to Mars in 2011, is equipped with a set of 12 engineering cameras. These cameras are build-to-print copies of the Mars Exploration Rover (MER) cameras, which were sent to Mars in 2003. The engineering cameras weigh less than 300 grams each and use less than 3 W of power. Images returned from the engineering cameras are used to navigate the rover on the Martian surface, deploy the rover robotic arm, and ingest samples into the rover sample processing system. The navigation cameras (Navcams) are mounted to a pan/tilt mast and have a 45-degree square field of view (FOV) with a pixel scale of 0.82 mrad/pixel. The hazard avoidance cameras (Haz - cams) are body-mounted to the rover chassis in the front and rear of the vehicle and have a 124-degree square FOV with a pixel scale of 2.1 mrad/pixel. All of the cameras utilize a frame-transfer CCD (charge-coupled device) with a 1024x1024 imaging region and red/near IR bandpass filters centered at 650 nm. The MSL engineering cameras are grouped into two sets of six: one set of cameras is connected to rover computer A and the other set is connected to rover computer B. The MSL rover carries 8 Hazcams and 4 Navcams.

Maki, Justin N.↗

Effects of Surface Processing on the Response of CZT Gamma Detectors: Studies with a Collimated Synchrotron X-Ray Beam

Using a microscale X-ray mapping technique incorporating a synchrotron beam, we are able to reveal the fine details of the surface properties in cadmium zinc telluride (CZT) semiconductor detectors. A detector, with various degrees of surface roughness, was irradiated by a high-spatial-resolution X-ray beam. The detector's response was analyzed and displayed as a two-dimensional (2-D) map, and the charge collection was obtained from the peak positions in the spectra versus the beam's location, which reflects the local material properties. We noted the correlation between the 2-D image and the spectral response of the charge collection at different locations on the surface area, which indicates that a rough surface tends to contain trapping centers, thereby enhancing leakage current and distorting the signal. We also discuss our observations on the transition effect at the boundary area of a rough and a smooth surface under identical conditions.

43 PARTICLE ACCELERATORS↗