Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

An Eddy Current Case Study using NASA’s Transfer Function and Limited-Sample Probability of Detection Guidebooks

Probability of detection (POD) requirements for NASA fracture-critical human-rated systems can be met by (1) claiming ‘similarity’ to NASA Standard Nondestructive Evaluation (NDE) flaw sizes or (2) by inspector-specific POD demonstration, known as NASA Special NDE. Standard NDE flaw sizes are intended to represent the detection capability of most qualified inspectors, and were primarily based on POD studies in the development of the Space Shuttle Program Orbiter fracture control plan. However, these Standard NDE flaw sizes were based on fatigue cracks in flat panels of one material alloy over a limited range of panel thicknesses. While the POD study was comprehensive, the inspection conditions are relatively narrow. An evaluation of similarity between the Standard NDE POD study and flight component conditions is required to apply Standard NDE to specific flight component inspections. A similarity evaluation may include differences in materials, surface finish, component geometry (e.g., curvature, corners, welds), and inspection access. Similarity is typically based on a qualitative engineering evaluation. Recently, NASA published a quantitative methodology to assess similarity. If similarity is not supported by test and analysis, then the methodology provides a transfer function of flaw size for Special NDE POD demonstration. NASA recommends that Special POD demonstrations use flaws that are flight-like or more difficult to detect than flight component flaws, which are commonly induced fatigue cracks. Often, it is not feasible to induce fatigue cracks in flight component geometry, and therefore, a simpler representative geometry is used, commonly a flat panel, for POD demonstration. Inducing cracks in simple geometry specimens can be time-consuming and expensive, and thus, minimizing the number of flawed specimens is desired. Traditionally, NASA Special NDE demonstration was limited to MIL-HDBK-1823A methods or the binomial point-estimate method (PEM), commonly known as 29/29. Recently, NASA published a limited-sample POD (LS-POD) methodology for signal-response NDE techniques (e.g., eddy current) that provides POD demonstration with fewer specimens than previous approaches. LS-POD suggests a minimum of 10 flawed specimens, compared to 29 in the PEM and the suggested minimum of 40 from MIL-HDBK-1823A. The methodology also includes new guidance on evaluating the probability of false calls. In this presentation, these new transfer function and LS-POD methodologies are described and illustrated through an eddy current detection capability of far-side flaws on thin welded panels. A geometry-based transfer function is developed using electro-discharge machined (EDM) notches in flight component and simple geometry to estimate the Special NDE flaw size that is representative of the critical initial flaw size required by the fracture analysis. Then, fatigue cracks are induced in simple flat panels of the transferred flaw size, and the LS-POD methodology is used for Special NDE demonstration.

P. A. Parker↗

Non-invasive (non-contact) measurements of human thermal physiology signals and thermal comfort/discomfort poses -A review

Heating, ventilation and air-conditioning (HVAC) systems have been adopted to create comfortable, healthy and safe indoor environments. In the control loop, the technical feature of the human demand-oriented supply can help operate HVAC effectively. Among many technical options, real time monitoring based on feedback signals from end users has been frequently reported as a critical technology to confirm optimizing building performance. Recent studies have incorporated human thermal physiology signals and thermal comfort/discomfort status as real-time feedback signals. A series of human subject experiments used to be conducted by primarily adopting subjective questionnaire surveys in a lab-setting study, which is limited in the application for reality. With the help of advanced technologies, physiological signals have been detected, measured and processed by using multiple technical formats, such as wearable sensors. Nevertheless, they mostly require physical contacts with the skin surface in spite of the small physical dimension and compatibility with other wearable accessories, such as goggles, and intelligent bracelets. Most recently, a low cost small infrared camera has been adopted for monitoring human facial images, which could detect the facial skin temperature and blood perfusion in a contactless way. Also, according to latest pilot studies, a conventional digital camera can generate infrared images with the help of new methods, such as the Euler video magnification technology. Human thermal comfort/discomfort poses can also be detected by video methods without contacting human bodies and be analyzed by the skeleton keypoints model. Here, new sensing technologies were summarized, their cons and pros were discussed, and extended applications for the demand-oriented ventilation were also reviewed as potential development and applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Describing Point Defect Topology in 2D Energy Materials through Computer Vision

Point defects such as vacancies and impurity atoms strongly impact the performance of 2D materials. Traditional efforts often rely on manual detection, a process that is time-intensive, prone to human error, and challenging to scale. Here we leverage machine learning (ML) methods to identify and quantify vacancies within 2D transition metal carbides (Ti3C2, MXenes), aiming to expedite detection while improving accuracy. MXenes exhibit valuable defect-defined electrochemical properties, but we currently lack statistical understanding of defect topology needed to fully harness these materials. Here we employ a convolutional neural network for semantic segmentation of experimental MXene images, opening an opportunity to conduct a rigorous statistical study on defect hierarchy while investigating local relaxation in the lattice. We show how the integration of ML can yield fundamental insight into point defects, providing a powerful tool that will play an increasingly crucial role in the future of materials science.

2d materials↗

Describing Point Defect Topology in 2D Energy Materials Through Computer Vision

Point defects such as vacancies and impurity atoms strongly impact the performance of 2D materials. Traditional efforts often rely on manual detection, a process that is time-intensive, prone to human error, and challenging to scale. Here we leverage machine learning (ML) methods to identify and quantify vacancies within 2D transition metal carbides (Ti3C2, MXenes), aiming to expedite detection while improving accuracy. MXenes exhibit valuable defect-defined electrochemical properties, but we currently lack statistical understanding of defect topology needed to fully harness these materials. We employ a convolutional neural network for semantic segmentation of experimental MXene images, opening an opportunity to conduct a rigorous statistical study on defect hierarchy while investigating local relaxation in the lattice. We show how the integration of ML can yield fundamental insight into point defects, providing a powerful tool that will play an increasingly crucial role in the future of materials science.

2D materials↗

Describing Point Defect Topology in 2D Energy Materials Through Computer Vision

Point defects such as vacancies and impurity atoms strongly impact the performance of 2D materials. Traditional efforts often rely on manual detection, a process that is time-intensive, prone to human error, and challenging to scale. Here we leverage machine learning (ML) methods to identify and quantify vacancies within 2D transition metal carbides (Ti3C2, MXenes), aiming to expedite detection while improving accuracy. MXenes exhibit valuable defect-defined electrochemical properties, but we currently lack statistical understanding of defect topology needed to fully harness these materials. Here we employ a convolutional neural network for semantic segmentation of experimental MXene images, opening an opportunity to conduct a rigorous statistical study on defect hierarchy while investigating local relaxation in the lattice. We show how the integration of ML can yield fundamental insight into point defects, providing a powerful tool that will play an increasingly crucial role in the future of materials science. ML is often not just a matter of straightforward application, and pretrained models proved ineffective in this case. Instead, we trained our own neural network (NN) and applied data augmentation techniques and fine-tuning to the training dataset. Since labeled microscopy data is often scarce, we developed training data from a previously published wide-frame MXene image, using customized Gaussian fitting to locate atomic positions. Our trained model was then applied to a large dataset of experimental images, enabling a statistical study of defect configurations across three samples prepared with different HF etchant concentrations (5%, 9.1%, and 12.5%), as shown in Fig. 1. This also allowed us to investigate local strain around vacancies, though we find that we are limited by the precision of measurements using high-angle annular dark field (HAADF) images, as shown in Fig. 2. This study demonstrates how ML enables large-scale, quantitative analysis of atomic defects - an otherwise infeasible task with traditional methods. While our NN was specialized for Ti3C2 MXenes, the pipeline we developed provides a foundation for future ML models tailored to other materials. Ultimately, we envision embedding the NN onto the microscope to give real-time feedback to the user. To make this a reality, continued work is necessary to fully understand the NN's capabilities and limitations. This study gets one step closer to our goals of automated experimentation moving away from traditional methods of manual labeling. As ML capabilities advance, we hope to continue adapting and applying these techniques in microscopy.

2D materials↗

Human auditory evoked potentials. II - Effects of attention

Attention directed toward auditory stimuli, in order to detect an occasional fainter 'signal' stimulus, caused a substantial increase in the N1 (83 msec) and P2 (161 msec) components of the auditory evoked potential without any change in preceding components. This evidence shows that human auditory attention is not mediated by a peripheral gating mechanism. The evoked response to the detected signal stimulus also contained a large P3 (450 msec) wave that was topographically distinct from the preceding components. This late positive wave could also be recorded in response to a detected omitted stimulus in a regular train and therefore seemed to index a stimulus-independent perceptual decision process.

Picton, T. W.↗

Detection of Drugstore Beetles in 9975 Packages using Acoustic Emissions

This report documents the initial feasibility tests performed using a commercial acoustic emission instrument for the purpose of detecting beetles in Department of Energy 9975 shipping packages. The device selected for this testing was a commercial handheld instrument and probe developed for the detection of termites, weevils, beetles and other insect infestations in wooden structures, trees, plants and soil. The results of two rounds of testing are presented. The first tests were performed by the vendor using only the hand-held instrument’s indications and real-time operator analysis of the audio signal content. The second tests included hands-free positioning of the instrument probe and post-collection analysis of the recorded audio signal content including audio background comparisons. The test results indicate that the system is promising for detecting the presence of drugstore beetles, however, additional work would be needed to improve the ease of detection and to automate the signal processing to eliminate the need for human interpretation. Mechanisms for hands-free positioning of the probe and audio background discrimination are also necessary for reliable detection and to reduce potential operator dose in radiation environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A cell-based Papain-like Protease (PLpro) activity assay for rapid detection of active SARS-CoV-2 infections and antivirals

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its variants are a continuous threat to human life. An urgent need remains for simple and fast tests that reliably detect active infections with SARS-CoV-2 and its variants in the early stage of infection. Here we introduce a simple and rapid activity-based diagnostic (ABDx) test that identifies SARS-CoV-2 infections by measuring the activity of a viral enzyme, Papain-Like protease (PLpro). The test system consists of a peptide that fluoresces when cleaved by SARS PLpro that is active in crude, unprocessed lysates from human tongue scrapes and saliva. Test results are obtained in 30 minutes or less using widely available fluorescence plate readers, or a battery-operated portable instrument for on-site testing. Proof-of-concept was obtained in a study on clinical specimens collected from patients with COVID-19 like symptoms who tested positive (n = 10) or negative (n = 10) with LIAT RT-PCR using nasal mid turbinate swabs. When saliva from these patients was tested with in-house endpoint RT-PCR, 17 were positive and only 5 specimens were negative, of which 2 became positive when tested 5 days later. PLpro activity correlated in 17 of these cases (3 out of 3 negatives and 14 out of 16 positives, with one invalid specimen). Despite the small number of samples, the agreement was significant (p value = 0.01). Two false negatives were detected, one from a sample with a late Ct value of 35 in diagnostic RT-PCR, indicating that an active infection was no longer present. The PLpro assay is easily scalable and expected to detect all viable SARS-CoV-2 variants, making it attractive as a screening and surveillance tool. Additionally, we show feasibility of the platform as a new homogeneous phenotypic assay for rapid screening of SARS-CoV-2 antiviral drugs and neutralizing antibodies.

60 APPLIED LIFE SCIENCES↗

An Automated Microfluidic Assay for Photonic Crystal Enhanced Detection and Analysis of an Antiviral Antibody Cancer Biomarker in Serum

Here, we report on the implementation of an automated platform for detecting the presence of an antibody biomarker for human papillomavirus-associated oropharyngeal cancer from a single droplet of serum, in which a nanostructured photonic crystal surface is used to amplify the output of a fluorescence-linked immunosorbent assay. The platform is comprised of a microfluidic cartridge with integrated photonic crystal chips that interfaces with an assay instrument that automates the introduction of reagents, wash steps, and surface drying. Upon assay completion, the cartridge interfaces with a custom laser-scanning instrument that couples light into the photonic crystal at the optimal resonance condition for fluorescence enhancement. The instrument is used to measure the fluorescence intensity values of microarray spots corresponding to the biomarkers of interest, in addition to several experimental controls that verify correct functioning of the assay protocol. In this work, we report both dose-response characterization of the system using anti-E7 antibody introduced at known concentrations into serum and characterization of a set of clinical samples from which results were compared with a conventional enzyme-linked immunosorbent assay (ELISA) performed in microplate format. Finally, the demonstrated capability represents a simple, rapid, automated, and high-sensitivity method for multiplexed detection of protein biomarkers from a low-volume test sample.

59 BASIC BIOLOGICAL SCIENCES↗

Structural and Functional Studies of Influenza Virus A/H6 Hemagglutinin

In June 2013, the first human infection by avian influenza A(H6N1) virus was reported in Taiwan. This incident raised the concern for possible human epidemics and pandemics from H6 viruses. In this study, we performed structural and functional investigation on the hemagglutinin (HA) proteins of the human-infecting A/Taiwan/2/2013(H6N1) (TW H6) virus and an avian A/chicken/Guangdong/S1311/2010(H6N6) (GD H6) virus that transmitted efficiently in guinea pigs. Our results revealed that in the presence of HA1 Q226, the triad of HA1 S137, E190 and G228 in GD H6 HA allows the binding to both avian- and human-like receptors with a slight preference for avian receptors. Its conservation among the majority of H6 HAs provides an explanation for the broader host range of this subtype. Furthermore, the triad of N137, V190 and S228 in TW H6 HA may alleviate the requirement for a hydrophobic residue at HA 1 226 of H2 and H3 HAs when binding to human-like receptors. Consequently, TW H6 HA has a slight preference for human receptors, thus may represent an intermediate towards a complete human adaptation. Importantly, the triad observed in TW H6 HA is detected in 74% H6 viruses isolated from Taiwan in the past 14 years, suggesting an elevated threat of H6 viruses from this region to human health. The novel roles of the triad at HA 1 137, 190 and 228 of H6 HA in binding to receptors revealed here may also be used by other HA subtypes to achieve human adaptation, which needs to be further tested in laboratory and closely monitored in field surveillance.

59 BASIC BIOLOGICAL SCIENCES↗

Detection of Carbon Monoxide Using Polymer-Composite Films with a Porphyrin-Functionalized Polypyrrole

Post-fire air constituents that are of interest to NASA include CO and some acid gases (HCl and HCN). CO is an important analyte to be able to sense in human habitats since it is a marker for both prefire detection and post-fire cleanup. The need exists for a sensor that can be incorporated into an existing sensing array architecture. The CO sensor needs to be a low-power chemiresistor that operates at room temperature; the sensor fabrication techniques must be compatible with ceramic substrates. Early work on the JPL ElectronicNose indicated that some of the existing polymer-carbon black sensors might be suitable. In addition, the CO sensor based on polypyrrole functionalized with iron porphyrin was demonstrated to be a promising sensor that could meet the requirements. First, pyrrole was polymerized in a ferric chloride/iron porphyrin solution in methanol. The iron porphyrin is 5, 10, 15, 20-tetraphenyl-21H, 23Hporphine iron (III) chloride. This creates a polypyrrole that is functionalized with the porphyrin. After synthesis, the polymer is dried in an oven. Sensors were made from the functionalized polypyrrole by binding it with a small amount of polyethylene oxide (600 MW). This composite made films that were too resistive to be measured in the device. Subsequently, carbon black was added to the composite to bring the sensing film resistivity within a measurable range. A suspension was created in methanol using the functionalized polypyrrole (90% by weight), polyethylene oxide (600,000 MW, 5% by weight), and carbon black (5% by weight). The sensing films were then deposited, like the polymer-carbon black sensors. After deposition, the substrates were dried in a vacuum oven for four hours at 60 C. These sensors showed good response to CO at concentrations over 100 ppm. While the sensor is based on a functionalized pyrrole, the actual composite is more robust and flexible. A polymer binder was added to help keep the sensor material from delaminating from the electrodes, and carbon was added to improve the conductivity of the material.

Homer, Margie L.↗

Label-free detection of Herceptin ® using suspended silicon microring resonators

In this paper, highly sensitive detection of heat denatured Herceptin ® (trastuzumab), an important monoclonal antibody used in breast cancer therapeutics, is demonstrated using transverse magnetic (TM) mode suspended microring resonators (MRRs). The suspended MRRs are surface functionalized with a single chain fragment variable (scFv) recombinant antibody molecule (designated 2B4) that enables selective capture of denatured Herceptin molecules. Interaction between guided modes in suspended MRRs and Herceptin molecules captured on the surfaces of the suspended MRRs enable straightforward optical detection and quantification of the bound Herceptin molecules. Clinically relevant Herceptin detection at a concentration of 100 nM is demonstrated and negligible signal was obtained from the sensor when exposed to Avastin ® (bevacizumab), a negative control human therapeutic monoclonal antibody. Importantly, at least a 2-fold enhanced detection sensitivity is obtained by suspending the microring (MRR) over the underlying substrate, effectively increasing the sensing surface area. Experimental results are supported by three-dimensional finite-difference time-domain simulations and optical mode analysis. Finally, the use of a label-free silicon photonic platform for high sensitivity molecular detection is compatible with high-throughput, low-cost diagnostics employing on-chip sensor arrays.

47 OTHER INSTRUMENTATION↗

Low power cw-laser signatures on human skin

Impact of cw laser radiation on autofluorescence features of human skin is studied. Two methods of autofluorescence detection are applied: the spectral method with the use of a fibreoptic probe and spectrometer for determining the autofluorescence recovery kinetics at a fixed skin area of {approx}12 mm{sup 2}, and the multispectral visualisation method with the use of a multispectral imaging camera for visualising long-term autofluorescence changes in a skin area of {approx}4 cm{sup 2}. The autofluorescence recovery kinetics after preliminary laser irradiation is determined. Skin autofluorescence images with visible long-term changes - 'signatures' of low power laser treatment are acquired. (application of lasers and laser-optical methods in life sciences)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of the JPL Electronic Nose to detect leaks and spills in an enclosed environment

An electronic nose to be used as an air quality monitor in human habitats in space has been developed at the Jet Propulsion Laboratory. This device is capable of detecting, identifying and quantifying several organic and inorganic chemical species which might be present as contaminants in spacecraft air. The complete portable device, including sensors, electronics, and software for data analysis, has been extensively tested.

environmental monitoring↗

Ch. 12. A Theoretical Approach to Management of Limited Attentional Resources to Support the m:N Operation in Advanced Air Mobility Ecosystem

Advanced air mobility (AAM) technologies incorporate increasingly autonomous systems that allow fully remote, independent, and intelligent operation of air vehicles to support the transportation of goods and passengers within and across urban and rural areas. With a myriad of automated technologies enabling the AAM ecosystem, the human operator’s role will likely be a passive supervisory monitor of the air vehicles, involving increasingly fewer humans (m) that manage many more autonomous systems (N), or m:N operations. Unfortunately, the human performance literature suggests that human operators will exhibit poor supervision of numerous autonomous agents due to the limits of attentional resources in the operators. In the general human information-processing model, a human operator exercises a limited pool of attentional resources to engage various information-processing stages including detecting, perceiving, comprehending, and predicting objects around them. Yamani and Horrey (2018) expanded the human information-processing model to characterize a tradeoff between information-processing demand and resource relief that automation brings in the context of automated driving. In their model, a driver interacting with an automated driving system is assumed to reallocate resources “freed” by automation to support other information-processing stages required for successful task performance. A future AAM ecosystem enabled by an orchestration of advanced automated systems, however, requires a single operator to interact with more than one air vehicle with varying levels and degrees of automated systems, making the traditional framework of human-automation interaction insufficient. To address this gap, we provide a review of the literature on situation assessment and trust, two constructs identified as critical for a fuller understanding of intimate and intricate interactions between a human operator and multiple air vehicles equipped with increasingly autonomous systems. Then, we propose an expansion of Yamani and Horrey’s (2018) model to motivate systematic research on the human operator’s role, identify factors that influence resource allocation and guide human-centered design of an interface supporting the m:N operation in the AAM environment.

Advanced Air Mobility↗

Evaluation of geophysical and anthropogenic sources of hydroacoustic noise in the Alaskan arctic

Quantifying the ocean soundscape is crucial for ocean-based seismoacoustic monitoring; it sets a baseline for the kinds and sizes of signals that can be detected above the background noise. As sea ice recedes, human activity in and around the Arctic Ocean is increasing, elevating sound levels and heightening the urgency of monitoring. Here, seven years of passive acoustic recordings from a National Oceanographic and Atmospheric Administration hydrophone in the Beaufort Sea are analyzed, focusing on frequencies between 1 and 125 Hz, a band of interest for detecting regional earthquakes and similar events. Sound is related to geophysical and anthropogenic sources, and seasonal and intraseasonal variations in the soundscape are examined. Sea ice emerges as a keystone feature of the Arctic Ocean acoustic environment, controlling or contributing to ambient sound levels at all frequencies studied. During low-ice months, sound levels are dominated by wind and sea surface waves, and in ice-covered months, wind-driven ice noise dominates. Seismic air gun surveys are prominent during low-ice periods, with sound levels decreasing with increasing distance and bathymetric complexity along the propagation path. The implications of this baseline soundscape for event detection in the Alaskan Arctic are discussed.

Niklasson, Siobhan [Los Alamos National Laboratory↗

Coincidence anomaly detection for unsupervised locating of edge localized modes in the DIII-D tokamak dataset

Using supervised learning to train a machine learning model to predict an on-coming edge localized mode (ELM) requires a large number of labeled samples. Creating an appropriate data set from the very large database of discharges at a long-running tokamak, such as DIII-D, would be a very time-consuming process for a human. Considering this need and difficulty, we use coincidence anomaly detection, an unsupervised learning technique, to train an ELM-identifier to identify and label ELMs in the DIII-D discharge database. This ELM-identifier shows, simultaneously, a precision of 0.68 and a recall of 0.63 (AUC is 0.73) on identifying ELMs in example time series pulled from thousands of discharges spanning five years. In a test set of 50 discharges, the algorithm finds over 26 thousand ELM candidates, more than 5 times the existing catalog of ELMs labeled by humans.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The human as a detector of changes in variance and bandwidth

The detection of changes in random process variance and bandwidth was studied. Psychophysical thresholds for these two parameters were determined using an adaptive staircase technique for second order random processes at two nominal periods (1 and 3 seconds) and damping ratios (0.2 and 0.707). Thresholds for bandwidth changes were approximately 9% of nominal except for the (3sec,0.2) process which yielded thresholds of 12%. Variance thresholds averaged 17% of nominal except for the (3sec,0.2) process in which they were 32%. Detection times for suprathreshold changes in the parameters may be roughly described by the changes in RMS velocity of the process. A more complex model is presented which consists of a Kalman filter designed for the nominal process using velocity as the input, and a modified Wald sequential test for changes in the variance of the residual. The model predictions agree moderately well with the experimental data. Models using heuristics, e.g. level crossing counters, were also examined and are found to be descriptive but do not afford the unification of the Kalman filter/sequential test model used for changes in mean.

Curry, R. E.↗