Shuttle active thermal control system development testing. Volume 5: Integrated radiator/expendable cooling system tests

Tests were conducted to gather data on a space shuttle active control system (ATCS) incorporating both radiators and an expendable cooling device to provide vehicle heat removal. Two systems were tested and design information was provided for both nominal and limit conditions. The tests verified the concept that an integrated radiator/expendable cooling system can adequately maintain desired water quantities while responding to variations in heat loads and environments. In addition, the need for duct heating was demonstrated, while exhaust nozzle heating was also shown to be unnecessary.

Scheps, P. B.↗

Winter performance of a domestic solar-heating system--Duffield, Virginia

Sunlight supplies 39 percent of heat load, saving 9 barrels of fuel oil in one heating season. Report describes system installation in two-story, single-family residence. Energy is collected with roof-mounted air flat-plate collectors, stored in rock bin, and transferred to water preheat tank whenever system is storing energy; heat pump supplies heat to house.

Source record↗

Test results of a pumped two-phase mounting plate with ammonia

The design, fabrication, and testing of full-scale prototype units of a two-phase mounting plate (TPMP), which will be used in a two-phase ammonia-based thermal control system for a large spacecraft, are described. The mounting plate uses an evaporator design in which liquid is mechanically pumped through porous feed tubes within the plate. The prototype TPMPs were tested with ammonia at heat loads over 3000 W (3.2 W/sq cm) and local heat fluxes of up to 4 W/sq cm. Calculated total heat transfer coefficients from these tests were between 0.8 and 1.0 W/sq cm per C. This represents a better than twenty-fold improvement over comparable single-phase heat transfer coefficients. Design diagrams are included.

Swanson, T. D.↗

A study of high-temperature heat pipes with multiple heat sources and sinks. I - Experimental methodology and frozen startup profiles. II - Analysis of continuum transient and steady-state experimental data with numerical predictions

Experimental profiles for heat pipe startup from the frozen state were obtained, using a high-temperature sodium/stainless steel pipe with multiple heat sources and sinks to investigate the startup behavior of the heat pipe for various heat loads and input locations, with both low and high heat rejection rates at the condensor. The experimental results of the performance characteristics for the continuum transient and steady-state operation of the heat pipe were analyzed, and the performance limits for operation with varying heat fluxes and location are determined.

Faghri, A.↗

Closed Form Equations for the Preliminary Design of a Heat-Pipe-Cooled Leading Edge

A set of closed form equations for the preliminary evaluation and design of a heat-pipe-cooled leading edge is presented. The set of equations can provide a leading-edge designer with a quick evaluation of the feasibility of using heat-pipe cooling. The heat pipes can be embedded in a metallic or composite structure. The maximum heat flux, total integrated heat load, and thermal properties of the structure and heat-pipe container are required input. The heat-pipe operating temperature, maximum surface temperature, heat-pipe length, and heat pipe-spacing can be estimated. Results using the design equations compared well with those from a 3-D finite element analysis for both a large and small radius leading edge.

Glass, David E.↗

Small Spacecraft Active Thermal Control: Micro-Vascular Composites Enable Small Satellite Cooling

The Small Spacecraft Integrated Power System with Active Thermal Control project endeavors to achieve active thermal control for small spacecraft in a practical and lightweight structure by circulating a coolant through embedded micro-vascular channels in deployable composite panels. Typically, small spacecraft rely on small body mounted passive radiators to discard heat. This limits cooling capacity and leads to the necessity to design for limited mission operations. These restrictions severely limit the ability of the system to dissipate large amounts of heat from radios, propulsion systems, etc. An actively pumped cooling system combined with a large deployable radiator brings two key advantages over the state of the art for small spacecraft: capacity and flexibility. The use of a large deployable radiator increases the surface area of the spacecraft and allows the radiation surface to be pointed in a direction allowing the most cooling, drastically increasing cooling capacity. With active coolant circulation, throttling of the coolant flow can enable high heat transfer rates during periods of increased heat load, or isolate the radiator during periods of low heat dissipation.

Deployable radiator↗

Calorimeter Heat Flux Trends in NASA’s Subscale Rotating Detonation Rocket Engine

A calorimeter-style rotating detonation rocket engine (RDRE) outer chamber body was designed, additively manufactured in GRCop-42, and hot-fire tested in test cell 105 at NASA Marshall Space Flight Center (MSFC) in Huntsville, AL in August 2024. Steady-state, spatially resolved heat flux and chamber pressure were measured at 13 and 9 locations from the injector face, respectively, for a variety of test conditions and hardware configurations with gaseous methane and oxygen propellants. The 2-in. diameter highly instrumented design, enabled by metal additive manufacturing (AM), allowed for simultaneous measurement of heat flux and chamber pressure through 44 long duration hot-fire tests without failure. Of the 44 tests, only 3 of the tests featured chamber pressures below 100 psia and are discussed in this work. Heat flux trends for this subscale hardware are explored with respect to local propellant mass flux for several different injectors, chamber lengths, and chamber “subsonic” area ratios (contraction ratios). Results show that for increasing chamber pressure, a reduced amount of energy per kilogram of propellant is transferred to the wall. Switching injectors affects the near-face heat flux and chamber pressure profiles. Chamber length does not noticeably affect the heat flux profile but increases bulk heat load. A subsonic area ratio greater than 1 reduces heat losses to the wall compared to a straight annulus case. Equivalence ratio shift did not significantly affect heat flux. Computational fluid dynamics (CFD) and conjugate heat transfer (CHT) analyses were performed to delineate 3-D heat transfer and coolant mass flow maldistribution effects and create a calorimeter transfer function to transform heat flux data and mitigate the profile distortions. Additional CFD/CHT simulations were performed using experimental data as boundary conditions to assess local nucleate boiling propensity during testing and to assess projected hot wall temperatures for future fatigue assessment. Vapor fractions were observed locally for several cases. It is anticipated that this effort will provide a common framework for coolant system design/analysis in calorimeter systems for rocket-based and air-breathing combustors, ensuring greater repeatability in calorimetry measurements across the research community.

Joseph Hernandez-McCloskey↗

Implosion dynamics and x-ray generation in small-diameter wire-array Z pinches

It is known from experiments that the radiated x-ray energy appears to exceed the calculated implosion kinetic energy and Spitzer resistive heating [C. Deeney et al., Phys. Rev. A 44, 6762 (1991)] but possible mechanisms of the enhanced x-ray production are still being discussed. Enhanced plasma heating in small-diameter wire arrays with decreased calculated kinetic energy was investigated, and a review of experiments with cylindrical arrays of 1-16 mm in diameter on the 1 MA Zebra generator is presented in this paper. The implosion and x-ray generation in cylindrical wire arrays with different diameters were compared to find a transition from a regime where thermalization of the kinetic energy is the prevailing heating mechanism to regimes with other dominant mechanisms of plasma heating. Loads of 3-8 mm in diameter generate the highest x-ray power at the Zebra generator. The x-ray power falls in 1-2 mm loads which can be linked to the lower efficiency of plasma heating with the lack of kinetic energy. The electron temperature and density of the pinches also depend on the array diameter. In small-diameter arrays, 1-3 mm in diameter, ablating plasma accumulates in the inner volume much faster than in loads of 12-16 mm in diameter. Correlated bubblelike implosions were observed with multiframe shadowgraphy. Investigation of energy balance provides evidence for mechanisms of nonkinetic plasma heating in Z pinches. Formation and evolution of bright spots in Z pinches were studied with a time-gated pinhole camera. A comparison of x-ray images with shadowgrams shows that implosion bubbles can initiate bright spots in the pinch. Features of the implosions in small-diameter wire arrays are discussed to identify mechanisms of energy dissipation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coupling strategies for high-speed aeroheating problems.

A common purpose for performing an aerodynamic analysis is to calculate the resulting loads on a solid body immersed in the flow. Pressure or heat loads are often of interest for characterizing the structural integrity or thermal survivability of the structure. This document describes two algorithms for tightly coupling the mass, momentum and energy conservation equations for a compressible fluid and the energy conservation equation for heat transfer through a solid. We categorize both approaches as monolithically coupled, where the conservation equations for the fluid and the solid are assembled into a single residual vector. Newton's method is then used to solve the resulting nonlinear system of equations. These approaches are in contrast to other popular coupling schemes such as staggered coupling methods were each discipline is solved individually and loads are passed between as boundary conditions, and demonstrates the viability of the monolithic approach for aeroheating problems.

99 GENERAL AND MISCELLANEOUS↗

Performance and cost of automotive fuel cell systems with ultra-low platinum loadings.

An automotive polymer-electrolyte fuel cell (PEFC) system with ultra-low platinum loading (0.15 mg-Pt cm{sup -2}) has been analyzed to determine the relationship between its design-point efficiency and the system efficiency at part loads, efficiency over drive cycles, stack and system costs, and heat rejection. The membrane electrode assemblies in the reference PEFC stack use nanostructured, thin-film ternary catalysts supported on organic whiskers and a modified perfluorosulfonic acid membrane. The analyses show that the stack Pt content can be reduced by 50% and the projected high-volume manufacturing cost by >45% for the stack and by 25% for the system, if the design-point system efficiency is lowered from 50% to 40%. The resulting penalties in performance are a <1% reduction in the system peak efficiency; a 2-4% decrease in the system efficiency on the urban, highway, and LA92 drive cycles; and a 6.3% decrease in the fuel economy of the modeled hybrid fuel-cell vehicle on the combined cycle used by EPA for emission and fuel economy certification. The stack heat load, however, increases by 50% at full power (80 kW{sub e}) but by only 23% at the continuous power (61.5 kW{sub e}) needed to propel the vehicle on a 6.5% grade at 55 mph. The reduced platinum and system cost advantages of further lowering the design-point efficiency from 40% to 35% are marginal. The analyses indicate that thermal management in the lower efficiency systems is very challenging and that the radiator becomes bulky if the stack temperature cannot be allowed to increase to 90-95 C under driving conditions where heat rejection is difficult.

30 DIRECT ENERGY CONVERSION↗

A Novel Approach for Bounding the Stress Experienced by the Core of Utility-Scale Printed Circuit Heat Exchangers Under Thermohydraulic Loads

Printed circuit heat exchangers (PCHEs) have rapidly gained popularity since being introduced nearly three decades ago, and they are currently widely deployed in the petrochemical and aviation industry. Their compactness, thermohydraulic efficiency, inherent suitability for high temperature/pressure fluids containment, and demonstrated durability are some of the reasons the nuclear industry is seeking to adopt this technology as well. However, the relatively strict nuclear-related regulatory design code, especially when classified as critical to the safety of the reactors, is posing challenges to adopting the technology. From stress analysis point of view, one undesirable feature of PCHEs is their geometrical complexity, which is implied by their multilength-scale features. As a result, a full-scale model of a utility-scale exchanger cannot simply be solved on a computer because meshing such components results in a vast number of degrees-of-freedom. Here, this work seeks to address the challenge of stress analyses to PCHEs by presenting a method to simplify the geometry of PCHE designs. The models proposed by this work can be practically analyzed on a standard computer and provide a path for implementing ASME design rules. The analyses presented herein are divided into five separate investigations. Each is carried out to incrementally simplify the analyzed model by addressing features such as the shapes of the flow passages, the complex distribution of stress in large components, the three-dimensionality of the stress and strain, the thermal stresses caused by thermohydraulic operation observed experimentally and more.

42 ENGINEERING↗

Carbon and energy cost impacts of electrification of space heating with heat pumps in the US

In order to meet climate goals, it will be necessary to significantly reduce the greenhouse gases emitted by homes. A key factor in the US is to reduce the on-site combustion of fossil fuels for heating end-uses and to replace this with use of electric heat pump technologies connected to a low-carbon grid. The replacement of natural gas furnaces with electric heat pumps is a key home decarbonization strategy. However, the potential for space heating electrification to reduce greenhouse gas emissions depends on the carbon dioxide equivalent (CO 2 e) content of the electricity used by the heat pump. This varies considerably depending on the source of electricity, with large state to state variability. Furthermore, household energy costs are likely to be impacted by the electrification of space heating, because retail energy prices for both natural gas and electricity in each state vary by factors of seven and four, respectively. Contractors, energy programs, government and building code officials, as well as consumers need clear indications of the likely CO 2 e and energy cost impacts of proposed electrification projects, because these will affect decarbonization choices and rationales around scaled heating electrification. Government and utility programs also need to be aware of the likely outcomes of any supported/incentivized measures. Here, in this paper, we investigate these effects by looking at new metrics to analyze the change in CO 2 e emitted and the cost to meet home heating loads when switching from a natural gas furnace to a heat pump for the contiguous 48 states of the mainland US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Combination Forced-Air Space and Tankless Domestic Hot Water Heating Systems

This document describes design and application guidance for combination space and tankless domestic hot water heating systems (combination systems) used in residential buildings, based on field evaluation, testing, and industry meetings conducted by Building Science Corporation. As residential building enclosure improvements continue to drive heating loads down, using the same water heatingequipment for both space heating and domestic water heating becomes attractive from an initial cost and space-saving perspective. This topic is applicable to single- and multi-family residential buildings, both new and retrofitted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Innovative Air-Source Heat Pumps for Cold-Climate Heating Applications

Air-source heat pumps (ASHPs) have historically found application in milder climates in the United States (US). Their application in cold climates has been hindered by reduced performance as outdoor temperatures fall below freezing and the need for backup or auxiliary electric resistance heaters to meet peak heating loads. Recent advances in cold-climate air-source heat pumps (ccASHPs) with features such as variable-speed compressors, multistage systems, and highly optimized thermal design have improved performance by increasing the coefficient of performance (COP), low-ambient-temperature capacity, and heating seasonal performance factor (HSPF) dramatically. Despite their benefits, ccASHPs are still not widely prescribed for cold climate conditions. This is due in part to a lack of verified, demonstrated performance and analysis in cold climates. Ultimately, high-efficiency ccASHPs play a key role in emerging energy/grid renovation efforts in addition to their potential energy savings and avoided carbon emissions, but their actual performance in various cold climate field settings must be better understood. The primary objective of this project was to measure the in-field performance of variable-capacity air-source heat pumps in cold climates with the goal of enabling the development of field-based performance maps. Specifically, the study looked at how the heat pumps operated in the field, the frequency of cycling, the frequency of defrost events, and the time spent in each mode of operation. The results are intended to be used by DOE to inform research and development of energy-efficient equipment and to develop guidelines for optimizing primary energy savings when using air-source heat pumps in heating-dominated regions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rotary Joint for Heat Transfer

Rotary joint exchanges heat between two heat pipes - one rotating and one stationary. Joint accommodates varying heat loads with little temperature drop across interface. According to concept, heat pipe enters center of disklike stationary section of joint. There, wicks in central artery of heat pipe separate into multiple strands that lead to concentric channels on rotaryinterface side of stationary disk. Thin layer of liquid sodium/potassium alloy carries heat from one member of rotary joint to other. Liquid conducts heat efficiently while permitting relative motion between members. Polypropylene rings contain liquid without interfering with rotation.

Shauback, R.↗

Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets

This design of the liquid-cooling garment for NASA spacesuits allows the suit to remove metabolic heat from the human body more effectively, thereby increasing comfort and performance while reducing system mass. The garment is also more flexible, with fewer restrictions on body motion, and more effectively transfers thermal energy from the crewmember s body to the external cooling unit. This improves the garment s performance in terms of the maximum environment temperature in which it can keep a crewmember comfortable. The garment uses flexible, highly thermally conductive sheet material (such as graphite), coupled with cooling water lines of improved thermal conductivity to transfer the thermal energy from the body to the liquid cooling lines more effectively. The conductive sheets can be layered differently, depending upon the heat loads, in order to provide flexibility, exceptional in-plane heat transfer, and good through-plane heat transfer. A metal foil, most likely aluminum, can be put between the graphite sheets and the external heat source/sink in order to both maximize through-plane heat transfer at the contact points, and to serve as a protection to the highly conductive sheets. Use of a wicking layer draws excess sweat away from the crewmember s skin and the use of an outer elastic fabric ensures good thermal contact of the highly conductive underlayers with the skin. This allows the current state of the art to be improved by having cooling lines that can be more widely spaced to improve suit flexibility and to reduce weight. Also, cooling liquid does not have to be as cold to achieve the same level of cooling. Specific areas on the human body can easily be targeted for greater or lesser cooling to match human physiology, a warmer external environment can be tolerated, and spatial uniformity of the cooling garment can be improved to reduce vasoconstriction limits. Elements of this innovation can be applied to other embodiments to provide effective heat transfer over a flexible and surface-conformable fashion without the limitation of fluid freeze points.

Ruemmele, Warren P.↗

Safe, High Power/Voltage Battery Module Design Challenges

NASA seeks to demonstrate a path for achieving safe, high power, and high performing Li-ion battery designs for the purpose of establishing design guidelines for our aeronautic and spacecraft applications. Safe means passively resistant to thermal runaway propagation of any single cell catastrophic thermal runaway. High power means capable of 3C continuous discharge without overheating. High performing means achieving > 160 Wh/kg, 200 Wh/L. The biggest challenge has been balancing a high flux light weight path for cell heat dissipation during the high rate discharge that minimizes thermal gradients between cells and also protects adjacent cells from the heat load of thermal runaway cell. Our solution includes an oscillating heat pipe spine that contacts every 18650 cell in the pack and careful cell design selection to maximize the range of initial temperatures conditions where the battery can safely complete the 3C discharge.

Thermal runaway↗

NASA Team Develops a Test Article to Demonstrate “Zero Boil-Off” Storage of Liquid Hydrogen via Cryocoolers and a Two-Stage Cooling Approach

Funded by NASA’s Technology Demonstration Mission Program and managed by the Cryogenic Fluid Management Portfolio Project, a NASA team is developing a test article to demonstrate the “zero boil-off” storage of liquid hydrogen using active cooling (cryocoolers) and a two-stage cooling approach. The current state of the art for storage of liquid hydrogen on-orbit is on the order of hours while future missions may require storage for months or even years. To enable such extended storage durations, “near zero” propellant loss, or “zero boil-off”, must be achieved. This may be accomplished with the implementation of “near zero” leakage components, a high performing suite of passive technologies to minimize the environmental heat loads, and active cooling via cryocoolers to intercept and remove heat from the propellant tanks and associated structure. Of course, with any cryogenic vehicle and mission, a mass and power trade should be conducted to determine if it is indeed feasible to carry the additional dry mass associated with active cooling, or if one could simply carry additional propellants to accommodate propellant loss which is typically not an option for a long duration mission.

Hydrogen Storage↗