Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

The effect of test-cell pressure on resistojet nozzle flow

Previous experimental work has shown that measured resistojet thrust decreases from that obtained at hard vacuum conditions as the test-cell pressure rises above 0.001 torr. Thrust losses have been observed for both cold and heated flow conditions, and the most significant losses have been experienced using thrusters with low Reynolds number flow and high area ratio nozzles. In order to further investigate nozzle flow characteristics, a pressure probe having four degrees of freedom has been used to obtain stagnation pressure surveys across the nozzle exit planes of four resistojets. The surveys show a change in the ratio of the supersonic core to the viscous boundary layer flow areas as the test-cell pressure increases. The surveys are also used for detecting whether an oblique shock is present in an overexpanded nozzle flow. Thruster temperature measurements and nozzle exit plane pressure surveys indicate that thrust losses are the combined result of convection heat losses and nozzle flow momentum effects.

Penko, Paul F.↗

BOILING HEAT TRANSFER TO LIQUID HYDROGEN AND NITROGEN IN FORCED FLOW

Boiling heat transfer to liquid hydrogen and nitrogen was investigated experimentally. Results are presented from a study of bulk boiling inside a cylindrical tube under vertically upward forced-flow conditions. A 0.555-inch-inside-diameter and 16 (1/8)-inch-long electrically heated stainless-steel tube was used. The range of variables studied for hydrogen were mass velocity of 2850 to 17,000 pounds per hour per square foot, local heat flux of 3600 to 40,000 Btu per hour per square foot, inlet pressure of 30 to 74 pounds per square inch absolute, and inlet subcooling of 0° to 9° R. Nitrogen test conditions were mass velocity of 15,000 to 56,000 pounds per hour per square foot, local heat flux of 2300 to 40,000 Btu per hour per square foot, inlet pressure of 47 to 56 pounds per square inch absolute, and inlet sub cooling of 1° to 6° R. The axial distribution of the tube-wall temperatures is presented. A transition in the type of boiling heat transfer was obtained. The critical heat flux corresponding to this transition was determined over a range of flow and heating rates and local qualities. At specific combinations of flow and transition location, a range of critical-heat-flux values was obtained and maximum values were determined. The maximum critical heat flux increased with increasing fluid-flow rate and decreased with increasing length of tube before transition. Similar variations of the maximum critical heat flux have been reported for water. The tube-inner-wall temperatures upstream of transition were essentially uniform and were only slightly greater than the fluid saturation temperature. The Wall-temperature profiles downstream of transition generally resembled those obtained in film-boiling studies and appeared to be strongly dependent upon local quality at the point of transition. Maximum wall temperatures of 9000 and 18000 R were obtained with hydrogen and nitrogen, respectively. Fluctuations of pressure, flow rate, and temperature occurred during some of the boiling tests. Under some conditions, maximum critical-heat-flux values were attained during steady-state operation with fluctuations. In other cases the fluctuations became uncontrolled, and critical-flux values less than the maximum values were obtained upon restabilization of the test conditions. No measurable pressure drop across the test section was obtained at any condition.

LIQUID HYDROGEN↗

The effect of the liquid-solid system properties on the interline heat transfer coefficient

A theoretical procedure to determine the heat transfer characteristics of the interline region of an evaporating meniscus using the macroscopic optical and thermophysical properties of the system is outlined. The analysis is based on the premise that the interline transport processes are controlled by the London-van der Waals forces between condensed phases (solid and liquid). The procedure is used to compare the relative size of the interline heat sink of various systems using a constant heat flux model. This solution demonstrates the importance of the interline heat flow number which is evaluated for various systems. The heat transfer characteristics of the decane-steel system are numerically compared with those of the carbon tetrachloride-quartz system.

Wayner, P. C., Jr.↗

Heat cascading regenerative sorption heat pump

A simple heat cascading regenerative sorption heat pump process with rejected or waste heat from a higher temperature chemisorption circuit (HTCC) powering a lower temperature physisorption circuit (LTPC) which provides a 30% total improvement over simple regenerative physisorption compression heat pumps when ammonia is both the chemisorbate and physisorbate, and a total improvement of 50% or more for LTPC having two pressure stages. The HTCC contains ammonia and a chemisorbent therefor contained in a plurality of canisters, a condenser-evaporator-radiator system, and a heater, operatively connected together. The LTPC contains ammonia and a physisorbent therefor contained in a plurality of compressors, a condenser-evaporator-radiator system, operatively connected together. A closed heat transfer circuit (CHTC) is provided which contains a flowing heat transfer liquid (FHTL) in thermal communication with each canister and each compressor for cascading heat from the HTCC to the LTPC. Heat is regenerated within the LTPC by transferring heat from one compressor to another. In one embodiment the regeneration is performed by another CHTC containing another FHTL in thermal communication with each compressor. In another embodiment the HTCC powers a lower temperature ammonia water absorption circuit (LTAWAC) which contains a generator-absorber system containing the absorbent, and a condenser-evaporator-radiator system, operatively connected together. The absorbent is water or an absorbent aqueous solution. A CHTC is provided which contains a FHTL in thermal communication with the generator for cascading heat from the HTCC to the LTAWAC. Heat is regenerated within the LTAWAC by transferring heat from the generator to the absorber. The chemical composition of the chemisorbent is different than the chemical composition of the physisorbent, and the absorbent. The chemical composition of the FHTL is different than the chemisorbent, the physisorbent, the absorbent, and ammonia.

Jones, Jack A.↗

Thermal Interface Evaluation of Heat Transfer from a Pumped Loop to Titanium-Water Thermosyphons

Titanium-water thermosyphons are being considered for use in the heat rejection system for lunar outpost fission surface power. Key to their use is heat transfer between a closed loop heat source and the heat pipe evaporators. This work describes laboratory testing of several interfaces that were evaluated for their thermal performance characteristics, in the temperature range of 350 to 400 K, utilizing a water closed loop heat source and multiple thermosyphon evaporator geometries. A gas gap calorimeter was used to measure heat flow at steady state. Thermocouples in the closed loop heat source and on the evaporator were used to measure thermal conductance. The interfaces were in two generic categories, those immersed in the water closed loop heat source and those clamped to the water closed loop heat source with differing thermal conductive agents. In general, immersed evaporators showed better overall performance than their clamped counterparts. Selected clamped evaporator geometries offered promise.

Jaworske, Donald A.↗

Review and Assessment of JPL's Thermal Margins

JPL has captured its experience from over four decades of robotic space exploration into a set of design rules. These rules have gradually changed into explicit requirements and are now formally implemented and verified. Over an extended period of time, the initial understanding of intent and rationale for these rules has faded and rules are now frequently applied without further consideration. In the meantime, mission classes and their associated risk postures have evolved, coupled with resource constraints and growing design diversity, bringing into question the current "one size fits all" thermal margin approach. This paper offers a systematic review of the heat flow path from an electronic junction to the eventual heat rejection to space. This includes the identification of different regimes along this path and the associated requirements. The work resulted in a renewed understanding of the intent behind JPL requirements for hot thermal margins and a framework for relevant considerations, which in turn enables better decision making when a deviation to these requirements is considered.

derating↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

Mantle viscosity stratification and flow geometry - Implications for surface motions on earth and Venus

For a fixed heat flow, the surface flow velocity of a convecting layer is not strongly sensitive to the variation of viscosity as a function of depth. Thus, the inferred absence of a low viscosity asthenosphere on Venus can not account for the limited surface motions there. The surface velocity is dependent on the convective geometry. Cartesian geometry convection can produce large surface velocities if the high viscosity surface layer is broken in places by weak zones. On the other hand, a high viscosity surface layer may inhibit the development of large surface velocities in axisymmetric convection.

Kiefer, Walter S.↗

Investigation of bubbles in arterial heat pipes

The behavior of gas occlusions in arterial heat pipes has been studied experimentally and theoretically. Specifically, the gas-liquid system properties, solubility and diffusivity, have been measured from -50 to 100 C for helium and argon in ammonia, Freon-21 (CHC12F), and methanol. Properties values obtained were then used to experimentally test models for gas venting from a heat pipe artery under isothermal conditions (i.e., no-heat flow), although the models, as developed, are also applicable to heat pipes operated at power, with some minor modifications. Preliminary calculations indicated arterial bubbles in a stagnant pipe require from minutes to days to collapse and vent. It has been found experimentally that a gas bubble entrapped within an artery structure has a very long lifetime in many credible situations. This lifetime has an approximately inverse exponential dependence on temperature, and is generally considerably longer for helium than for argon. The models postulated for venting under static conditions were in general quantitative agreement with experimental data. Factors of primary importance in governing bubble stability are artery diameter, artery wall thickness, noncondensible gas partial pressure, and the property group (the Ostwald solubility coefficient multiplied by the gas/liquid diffusivity).

Saaski, E. W.↗

Heat pipe heat rejection system

A prototype of a battery heat rejection system was developed which uses heat pipes for more efficient heat removal and for temperature control of the cells. The package consists of five thermal mock-ups of 100 amp-hr prismatic cells. Highly conductive spacers fabricated from honeycomb panels into which heat pipes are embedded transport the heat generated by the cells to the edge of the battery. From there it can be either rejected directly to a cold plate or the heat flow can be controlled by means of two variable conductance heat pipes. The thermal resistance between the interior of the cells and the directly attached cold plate was measured to be 0.08 F/Watt for the 5-cell battery. Compared to a conductive aluminum spacer of equal weight the honeycomb/heat pipe spacer has approximately one-fifth of the thermal resistance. In addition, the honeycomb/heat pipe spacer virtually eliminates temperature gradients along the cells.

Kroliczek, E. J.↗

Main Geomagnetic Field Models from Oersted and Magsat Data Via a Rigorous General Inverse Theory with Error Bounds

The purpose of the grant was to study how prior information about the geomagnetic field can be used to interpret surface and satellite magnetic measurements, to generate quantitative descriptions of prior information that might be so used, and to use this prior information to obtain from satellite data a model of the core field with statistically justifiable error estimates. The need for prior information in geophysical inversion has long been recognized. Data sets are finite, and faithful descriptions of aspects of the earth almost always require infinite-dimensional model spaces. By themselves, the data can confine the correct earth model only to an infinite-dimensional subset of the model space. Earth properties other than direct functions of the observed data cannot be estimated from those data without prior information about the earth. Prior information is based on what the observer already knows before the data become available. Such information can be "hard" or "soft". Hard information is a belief that the real earth must lie in some known region of model space. For example, the total ohmic dissipation in the core is probably less that the total observed geothermal heat flow out of the earth's surface. (In principle, ohmic heat in the core can be recaptured to help drive the dynamo, but this effect is probably small.) "Soft" information is a probability distribution on the model space, a distribution that the observer accepts as a quantitative description of her/his beliefs about the earth. The probability distribution can be a subjective prior in the sense of Bayes or the objective result of a statistical study of previous data or relevant theories.

Backus, George E.↗

Final Mission and Navigation Design for the 2016 Mars InSight Mission

Project Overview: NASA’s 12th Discovery Program mission that will place a single geophysical lander on Mars to study its deep interior using seismic (tidal, marsquake, and impact), rotational, and thermal measurements -First mission to unveil the composition, structure and thermal state of martian crust, mantle and core; Rebuild of the Phoenix flight system, upgraded with Juno/GRAIL avionics -Phoenix cruise stage: 3-axis stabilized, 3.2 square meter UTJ (Ultra Triple-Junction) solar array, X-band telecom -Phoenix aeroshell (heat shield, backshell, parachute) -Phoenix lander: radar, pulsed thrusters, legs, payload deck, 5.1 square meter UTJ solar arrays, two redundant Li-ion batteries, UHF (Ultra High Frequency)/X-band telecom -Dual string: Internally or functionally-redundant equipment; Science Payload -SEIS (Seismic Experiment for Interior Structure) / CNES (Centre National d’Etudes Spatiales); Three-axis seismometry, to measure seismic waves traveling through the interior -HP3 (Heat Flow and Physical Properties Probe) / DLR (German Aerospace Center) -Subsurface heat probe, to measure the heat flux from the interior - RISE (Rotation and Interior Structure Experiment) / JPL (Jet Propulsion Laboratory) -Radiometric geodesy, to determine precession & nutation of the planet’s rotation axis. 2016 Disclaimer: The InSight launch in 2016 was suspended due to critical issues with the Seismic Experiment for Interior Structure (SEIS) instrument that could not be fixed prior to the planned launch period. This presentation and its corresponding paper represent the state of the design for the 2016 mission. No attempt has been made to reflect the latest developments. [2018 Note: InSight (Mars Lander) was later launched and arrived on Mars on Nov. 26, 2018.]

Abilleira, F.↗

Valuation of Novel Waste Heat Sources and a Path Towards Adoption: Preprint

It is recognized that beneficial electrification of most space heating will be necessary to avert the worst consequences of climate change. Fifth generation district heating and cooling (5GDHC) networks operate at near-ambient temperatures and thus facilitate heating electrification, as well as the use of waste heat sources at a wide range of temperatures. In this paper, we analyze the potential of waste heat to supply the required heat to these networks and describe the business models that could expand the use of these waste heat sources. Showcase single family and commercial districts in the US are discussed to demonstrate emerging technologies, district infrastructure approaches, and third-party thermal utility funding models for these leading 5GDHC networks. As part of this work, heat flow and temperature profiles from five different types of waste heat sources are analyzed. An example district is used to examine the integration potential and to quantify the potential reduction in energy consumption. The results indicate that 5GDHC networks are highly suitable systems for utilizing low to moderate temperature waste heat sources. In the studied district, waste heat can cover a share of up to 66% of the heat supplied to the ambient loop and reduce the overall electricity consumption for heating by up to 51%, depending on the characteristics of the specific power, temperature, and type of waste heat source. Through their moderate operating temperatures and use of waste heat sources combined with third party financed infrastructure, 5GDHC districts have significant potential to reduce carbon emissions associated with space conditioning.

district energy↗

Optimal Energy Scheduling and Sensitivity Analysis for Integrated Power-Water-Heat Systems

The conventionally independent power, water, and heating networks are becoming more tightly connected, which motivates their joint optimal energy scheduling to improve the overall efficiency of an integrated energy system. However, such a joint optimization is known as a challenging problem with complex network constraints and couplings of electric, hydraulic, and thermal models that are nonlinear and nonconvex. We formulate an optimal power-water-heat flow (OPWHF) problem and develop a computationally efficient heuristic to solve it. The proposed heuristic decomposes OPWHF into subproblems, which are iteratively solved via convex relaxation and convex-concave procedure. Simulation results validate that the proposed framework can improve operational flexibility and social welfare of the integrated system, wherein the water and heating networks respond as virtual energy storage to time-varying energy prices and solar photovoltaic generation. Moreover, we perform sensitivity analysis to compare two modes of heating network control: by flow rate and by temperature. Our results reveal that the latter is more effective for heating networks with a wider space of pipeline parameters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dish stirling solar receiver combustor test program

The operational and energy transfer characteristics of the Dish Stirling Solar Receiver (DSSR) combustor/heat exchanger system was evaluated. The DSSR is designed to operate with fossil fuel augmentation utilizing a swirl combustor and cross flow heat exchanger consisting of a single row of 4 closely spaced tubes that are curved into a conical shape. The performance of the combustor/heat exchanger system without a Stirling engine was studied over a range of operating conditions and output levels using water as the working fluid. Results show that the combustor may be started under cold conditions, controlled safety, and operated at a constant air/fuel ratio (10 percent excess air) over the required range of firing rates. Furthermore, nondimensional heat transfer coefficients based on total heat transfer are plotted versus Reynolds number and compared with literature data taken for single rows of closely spaced tubes perpendicular to cross flow. The data show enhanced heat transfer for the present geometry and test conditions. Analysis of the results shows that the present system meets specified thermal requirements, thus verifying the feasibility of the DSSR combustor design for final prototype fabrication.

Bankston, C. P.↗