Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guidance document”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Proof Testing of Small-Scale HE Press Shielding

High explosives pressing activities at Los Alamos National Laboratory have played a critical role in meeting the core missions of the lab since its early days. Small scale pressing (25 grams of energetic material or less) constitutes a significant portion of current production and much of this occurs as an attended operation. Workers that are present during HE pressing operations are to be protected from blast and fragment dangers associated with the potential violent reaction of the energetic material being pressed. Safety is paramount in all HE operations, and the ongoing evolution of analysis and mitigation of hazards contributes strongly to the development of adequate protections for personnel. Attended pressing operations satisfying Class 1 Level Protection criteria, until recently, have been allowed for small scale pressing activities on the basis of an undocumented design of shielding enclosures used at LANL. Recent review of the shield design has determined the necessity of proof testing an adequate enclosure and thoroughly documenting the test results and fabrication specifications. This will provide a basis for continuing attended operations and guidance for future design iterations. The results of the testing described in this report provide sufficient assurance that the new shield design is adequate to protect attendant workers against injury from direct blast and fragments resulting from full detonation of the maximum allowable mass of explosives (less than 25 grams) confined in a uniaxial pressing configuration typical for Los Alamos National Laboratory.

42 ENGINEERING↗

Use of the Tool to Support Renewable Energy Auctions Processes (RE Data Explorer)

Renewable energy auctions are now a common competitive approach to procure low-cost renewable power around the world. Ensuring a successful auction process increasingly depends on the capabilities of auction designers and participants to identify actionable and defensible insights from large data sets (on renewable energy resources and complementary data) to both attract potential investors and address stakeholder concerns. The Renewable Energy (RE) Data Explorer is a user-friendly geospatial analysis tool for analyzing renewable energy potential and informing decisions. Developed by the National Renewable Energy Laboratory (NREL) and supported by the U.S. Agency for International Development (USAID), RE Data Explorer performs visualization and analysis of renewable energy potential that can be customized for different scenarios. RE Data Explorer can support prospecting, integrated planning, policymaking, and other decision-making activities to accelerate renewable energy deployment. The broader RE Explorer website provides guidance and information to link the RE Data Explorer geospatial analysis tool to key decision areas. This document provides information on how the RE Data Explorer can be used to support renewable energy auction processes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

TCV software test and validation tools and technique

The paper describes techniques for testing and validating software for the TCV (Terminal Configured Vehicle) program which is intended to solve problems associated with operating a commercial transport aircraft in the terminal area. The TCV research test bed is a Boeing 737 specially configured with digital computer systems to carry out automatic navigation, guidance, flight controls, and electronic displays research. The techniques developed for time and cost reduction include automatic documentation aids, an automatic software configuration, and an all software generation and validation system.

Straeter, T. A.↗

Assessment of Microphone Phased Array for Measuring Launch Vehicle Lift-off Acoustics

The specific purpose of the present work was to demonstrate the suitability of a microphone phased array for launch acoustics applications via participation in selected firings of the Ares I Scale Model Acoustics Test. The Ares I Scale Model Acoustics Test is a part of the discontinued Constellation Program Ares I Project, but the basic understanding gained from this test is expected to help development of the Space Launch System vehicles. Correct identification of sources not only improves the predictive ability, but provides guidance for a quieter design of the launch pad and optimization of the water suppression system. This document contains the results of the NASA Engineering and Safety Center assessment.

Garcia, Roberto↗

FEMP Facility Evaluation (Audit) Decision Tree

This document is a resource to be used in concert with FEMP Audit Definitions, FEMP Consolidated Facility Management Guidance, and agency best practices and expert judgment—for agencies to use to determine the best approaches to evaluate their facilities. It features a decision tree that provides a framework for agencies to interpret gathered facility data to understand the existing conditions; benchmark the facility against others in the portfolio to determine whether an on-site or remote audit is appropriate for a facility; determine the best remote or on-site audit level of detail to meet agency facility auditing goals, such as meeting Energy Independence and Security Act of 2007 requirements and developing projects; and improve their energy and water management programs.

auditing↗

Guidance for decommissioning plants entering safe storage - 15280

Although a number of plants worldwide have been placed into safe storage after permanent shutdown, there is no generic guidance for establishment of safe storage conditions. To address this need, EPRI is conducting a project to document the best practices to reduce risk, maintenance and monitoring requirements during safe storage, as well as practices that optimize decommissioning following the safe storage period. This project additionally evaluates potential options for establishment of safe storage conditions, such as performance of chemical decontamination, completion of environmental remediation activities, early removal of highly activated components, dismantlement of non-power block structures and partial site release in advance of completion of decommissioning of the nuclear island. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Revisions to ANSI Z136.1-2007 : safe use of lasers.

The parent document and cornerstone of the Z136 series of laser safety standards, the revised ANSI Z136.1 (2007) provides guidance for the safe use of lasers and laser systems by defining control measures for each of the four laser classes. As a result of advances in laser devices and applications, new guidelines have been incorporated into this 2007 revision. The new revision should be obtained by all laser end users and is a must for users of class 3B and 4 lasers as it renders all previous editions obsolete. Since the ANSI Z136.1 standard is the foundation of laser safety programs for industrial, military, medical, and educational applications nationwide, revisions to the previous version can and will affect the training and practice of laser safety in these environments. Changes to the previous version include the addition of new laser hazard classification definitions, new requirements for refresher training, and changes to medical surveillance requirements. The ANSI Z136.1 (2007) standard provides an updated and thorough set of guidelines for implementing a safe laser program. In addition to these changes, the standard covers laser safety program provisions including the duties and responsibilities of the LSO, non-beam hazards, administrative/engineering control measures, definitions, optical density, nominal hazard zone (NHZ), MPEs, accessible emission limit (AEL), bioeffects, standard operating procedures (SOPs), and example calculations.

59 BASIC BIOLOGICAL SCIENCES↗

Cockpit Interfaces, Displays, and Alerting Messages for the Interval Management Alternative Clearances (IMAC) Experiment

This document describes the IM cockpit interfaces, displays, and alerting capabilities that were developed for and used in the IMAC experiment, which was conducted at NASA Langley in the summer of 2015. Specifically, this document includes: (1) screen layouts for each page of the interface; (2) step-by-step instructions for data entry, data verification and input error correction; (3) algorithm state messages and error condition alerting messages; (4) aircraft speed guidance and deviation indications; and (5) graphical display of the spatial relationships between the Ownship aircraft and the Target aircraft. The controller displays for IM will be described in a separate document.

Baxley, Brian T.↗

Advancing practice relating to SEA alternatives

Developing and assessing alternatives is a key and central stage to Strategic Environmental Assessment (SEA). However, research has repeatedly reported this stage as one of the most poorly undertaken aspects of the SEA process. Current practice limitations include belated consideration of reasonable alternatives, narrow scope of alternatives that often include unrealistic or retrofitted options, limited stakeholder and public involvement in their identification, assessment and selection, lack of systematic approaches to their assessment and comparison, and inadequate reporting of the ‘storyline’ on how they were identified, what the potential impacts are and why the preferred alternative was selected. These issues have resulted in objections and judicial reviews. On the positive side, a number of good practice case studies enable extraction of key lessons and formulation of a set of general recommendations to advance practice in SEA alternatives. In this paper, practical guidance on the identification and development of alternatives, their assessment and comparison, selection of the preferred option, and documentation of the process and the reasons for selection is provided and discussed to frame good practice approaches. - Highlights: • Alternatives are one of the most poorly completed aspects of Strategic Environmental Assessment. • Current practice limitations need to be addressed to enhance SEA effectiveness. • A set of recommendations are extracted from good practice case studies. • These recommendations can be applied across jurisdictions and sectors and tailored as necessary.

54 ENVIRONMENTAL SCIENCES↗

Site 300 (Facility ID N-472) Toxic Emissions Inventory Plan

The Air Toxics "Hot Spots" Information and Assessment Act (AB 2588 or the “Act”) was enacted in September 1987. Under the Act, stationary sources are required to report the types and quantities of certain toxic substances their facilities routinely release into the air. AB 2588 is designed to provide information to state and local agencies and to the general public on the extent of airborne emissions from stationary sources and the potential public health impacts of those emissions. The San Joaquin Valley Air Pollution Control District (the District) is mandated by the State to implement AB 2588. On March 6, 2015, The State Office of Environmental Health Hazard Assessment (OEHHA) adopted changes to the Air Toxics Hot Spots Program Guidance Manual for the Preparation of Health Risk Assessments. These revisions were designed to incorporate three technical support documents and to provide enhanced protection of children as required under state law (SB 25, Escutia, 1999). Due to these recent changes, and the corresponding potential increases in calculated health risk, the District notified LAWRENCE LIVERMORE NATL SECURITY, LLC that we must be re-evaluated under AB 2588. Pursuant to the Air Toxics "Hot Spots" Information and Assessment Act of 1987, we have prepared a comprehensive, site-specific Toxics Emissions Inventory Plan. The plan specifies in detail how LAWRENCE LIVERMORE NATL SECURITY, LLC will inventory our facility's emissions of all toxic substances on the list of substances subject to the Act. The plan provides a comprehensive and detailed description of the methods that will be used to quantify air releases or potential air releases of listed substances from all points of release. The plan also includes quantification methods which result in accurate and comprehensive characterization of releases and comply with all applicable requirements of the “Hot Spots” regulation.

54 ENVIRONMENTAL SCIENCES↗

Lawrence Livermore National Security, LLCSite 300: Toxic Emissions Inventory Plan for ABA 2588 California Air Toxics "Hot Spots" Information and Assessment Act of 1987 (Revision 3.0)

The Air Toxics "Hot Spots" Information and Assessment Act (AB 2588 or the “Act”) was enacted in September 1987. Under the Act, stationary sources are required to report the types and quantities of certain toxic substances their facilities routinely release into the air. AB 2588 is designed to provide information to state and local agencies and to the general public on the extent of airborne emissions from stationary sources and the potential public health impacts of those emissions. The San Joaquin Valley Air Pollution Control District (the District) is mandated by the State to implement AB 2588. On March 6, 2015, The State Office of Environmental Health Hazard Assessment (OEHHA) adopted changes to the Air Toxics Hot Spots Program Guidance Manual for the Preparation of Health Risk Assessments. These revisions were designed to incorporate three technical support documents and to provide enhanced protection of children as required under state law (SB 25, Escutia, 1999). Due to these recent changes, and the corresponding potential increases in calculated health risk, the District notified LAWRENCE LIVERMORE NATIONAL SECURITY, LLC that we must be re-evaluated under AB 2588. Pursuant to the Air Toxics "Hot Spots" Information and Assessment Act of 1987, we have prepared a comprehensive, site-specific Toxics Emissions Inventory Plan. The plan specifies in detail how LAWRENCE LIVERMORE NATIONAL SECURITY, LLC will inventory our facility's emissions of all toxic substances on the list of substances subject to the Act. The plan provides a comprehensive and detailed description of the methods that will be used to quantify air releases or potential air releases of listed substances from all points of release. The plan also includes quantification methods which result in accurate and comprehensive characterization of releases and comply with all applicable requirements of the “Hot Spots” regulation.

54 ENVIRONMENTAL SCIENCES↗

RECOMMENDATIONS FOR SAMPLING OF TANK 19 IN F TANK FARM

Representative sampling is required for characterization of the residual material in Tank 19 prior to operational closure. Tank 19 is a Type IV underground waste storage tank located in the F-Tank Farm. It is a cylindrical-shaped, carbon steel tank with a diameter of 85 feet, a height of 34.25 feet, and a working capacity of 1.3 million gallons. Tank 19 was placed in service in 1961 and initially received a small amount of low heat waste from Tank 17. It then served as an evaporator concentrate (saltcake) receiver from February 1962 to September 1976. Tank 19 also received the spent zeolite ion exchange media from a cesium removal column that once operated in the Northeast riser of the tank to remove cesium from the evaporator overheads. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual waste, Huff and Thaxton [2009] developed a plan to sample the waste during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 19 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 19. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North and South hemispheres is currently supported by a single Mantis rover sample in each hemisphere. A floor scrape sample was obtained from a compact region near the center riser slightly in the South hemisphere and has been analyzed for a shortened list of key analytes. There is not enough additional material from the floor scrape sample material for completing the full suite of constituents. No floor scrape samples have been previously taken from the North hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 19 residual floor material, four additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Three of the four additional samples from each hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape sample results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially the analyte concentrations in the residual material on the floor of Tank 19 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 19 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.

36 MATERIALS SCIENCE↗

RECOMMENDATIONS FOR SAMPLING OF TANK 18 IN F TANK FARM

Representative sampling is required for characterization of the residual floor material in Tank 18 prior to operational closure. Tank 18 is an 85-foot diameter, 34-foot high carbon steel tank with nominal operating volume of 1,300,000 gallons. It is a Type IV tank, and has been in service storing radioactive materials since 1959. Recent mechanical cleaning of the tank removed all mounds of material. Anticipating a low level of solids in the residual material, Huff and Thaxton [2009] developed a plan to sample the material during the final clean-up process while it would still be resident in sufficient quantities to support analytical determinations in four quadrants of the tank. Execution of the plan produced fewer solids than expected to support analytical determinations in all four quadrants. Huff and Thaxton [2009] then restructured the plan to characterize the residual floor material separately in the North and the South regions: two 'hemispheres.' This document provides sampling recommendations to complete the characterization of the residual material on the tank bottom following the guidance in Huff and Thaxton [2009] to split the tank floor into a North and a South hemisphere. The number of samples is determined from a modification of the formula previously published in Edwards [2001] and the sample characterization data for previous sampling of Tank 18 described by Oji [2009]. The uncertainty is quantified by an upper 95% confidence limit (UCL95%) on each analyte's mean concentration in Tank 18. The procedure computes the uncertainty in analyte concentration as a function of the number of samples, and the final number of samples is determined when the reduction in the uncertainty from an additional sample no longer has a practical impact on results. The characterization of the full suite of analytes in the North hemisphere is currently supported by a single Mantis rover sample obtained from a compact region near the center riser. A floor scrape sample was obtained from a compact region near the northeast riser and has been analyzed for a shortened list of key analytes. Since the unused portion of the floor scrape sample material is archived and available in sufficient quantity, additional analyses need to be performed to complete results for the full suite of constituents. The characterization of the full suite of analytes in the South hemisphere is currently supported by a single Mantis rover sample; there have been no floor scrape samples previously taken from the South hemisphere. The criterion to determine the number of additional samples was based on the practical reduction in the uncertainty when a new sample is added. This was achieved when five additional samples are obtained. In addition, two archived samples will be used if a contingency such as failing to demonstrate the comparability of the Mantis samples to the floor scrape samples occurs. To complete sampling of the Tank 18 residual floor material, three additional samples should be taken from the North hemisphere and four additional samples should be taken from the South hemisphere. One of the samples from each hemisphere will be archived in case of need. Two of the three additional samples from the North hemisphere and three of the four additional samples from the South hemisphere will be analyzed. Once the results are available, differences between the Mantis and three floor scrape samples (the sample previously obtained near NE riser plus the two additional samples that will be analyzed) results will be evaluated. If there are no statistically significant analyte concentration differences between the Mantis and floor scrape samples, those results will be combined and then UCL95%s will be calculated. If the analyte concentration differences between the Mantis and floor scrape samples are statistically significant, the UCL95%s will be calculated without the Mantis sample results. If further reduction in the upper confidence limits is needed and can be achieved by the addition of the archived samples, they will be analyzed and included in the statistical computations. Initially, the analyte concentrations in the residual material on the floor of Tank 18 will be determined separately in the North and the South hemispheres. However, if final sampling results show that differences between the North and South samples are consistent within sampling variation, then the final computations can be based on consolidating all sample results from the tank floor. Recommended locations may be subject to physical tank access and sampling constraints for the additional samples. The recommendations have been discussed in Section 4 and are based on partitioning the Tank 18 floor into an inner and an outer ring and six 60{sup o} sectors depicted in Figure 1. The location of the border between the inner and outer rings is based on dividing the residual material into two approximately equal volumes.

36 MATERIALS SCIENCE↗

Real-Time EDL Navigation Performance Using Spacecraft to Spacecraft Radiometric Data

A two-year task sponsored by NASA's Mars Technology Program's Advanced Entry, Descent and Landing (EDL) work area includes investigation of improvements to EDL navigation by processing spacecraft-to-spacecraft radiometric data. Spacecraft-to-spacecraft navigation will take advantage of the UHF link between two spacecraft (i.e. to an orbiter from an approaching lander for EDL telemetry relay) to build radiometric data, specifically the velocity between the two spacecraft along the radio beam, that are processed to determine position and velocity in real time. The improved onboard state knowledge provided by spacecraft-to-spacecraft navigation will improve the performance of entry guidance by providing a more accurate state estimate and ultimately reduce the landed position error. A previous paper documented the progress of the first year of this task, including the spacecraft definitions, selection and documentation of the required algorithms and analysis results used to define the algorithm set. The final year of this task is reported here. Topics include modifications to the previously selected algorithm set for implementation, and performance of the implemented algorithms in a stand-alone filter, on an emulator of the target processor and finally on a breadboard processing unit.

navigation↗

Decarbonizing Industrial Heat and Electricity Applications Using Advanced Nuclear Energy

Idaho National Laboratory (INL) is investigating the technical pathways to assist industrial heat and electricity users to meet their decarbonization goals through integration with advanced nuclear power plants (NPPs). This project will deliver a library of process models and accompanying documents that guide specific industries in choosing potential nuclear technologies based on their needs. Considerations in providing this guidance include specific hazards from the industrial facility, heat transport requirements and associated technologies, and feasibility with site-specific demand profiles. The library of facility process models will be based on real data from industrial facilities in the United States. The industrial processes will be identified in this project based on the following: (1) operational heat characteristics that nuclear systems can provide, (2) sufficient energy requirements to merit the capital investment for nuclear plant construction, and (3) environmental benefits of replacing existing energy production with carbon-free nuclear power. Other decarbonization opportunities considered are the addition of nuclear-powered electrolysis processes or high-temperature electric heating where the thermal requirements exceed nuclear generation conditions. In addition to assessing the technical feasibility, INL is evaluating the impact of hazards introduced by the industrial facilities on the siting requirements of advanced NPPs. Site characterization of an industrial plant is essential to determine the feasibility and suitable integration methods for each industry. The assessment of siting and technical data will reveal opportunities for a single-use nuclear integration as well as integration of multiple industrial facilities with a single NPP.

02 PETROLEUM↗

Criticality Safety Controls and the Safety Basis at PFP

With the implementation of DOE Order 420.1B, Facility Safety, and DOE-STD-3007-2007, 'Guidelines for Preparing Criticality Safety Evaluations at Department of Energy Non-Reactor Nuclear Facilities', a new requirement was imposed that all criticality safety controls be evaluated for inclusion in the facility Documented Safety Analysis (DSA) and that the evaluation process be documented in the site Criticality Safety Program Description Document (CSPDD). At the Hanford site in Washington State the CSPDD, HNF-31695, 'General Description of the FH Criticality Safety Program', requires each facility develop a linking document called a Criticality Control Review (CCR) to document performance of these evaluations. Chapter 5, Appendix 5B of HNF-7098, Criticality Safety Program, provided an example of a format for a CCR that could be used in lieu of each facility developing its own CCR. Since the Plutonium Finishing Plant (PFP) is presently undergoing Deactivation and Decommissioning (D&D), new procedures are being developed for cleanout of equipment and systems that have not been operated in years. Existing Criticality Safety Evaluations (CSE) are revised, or new ones written, to develop the controls required to support D&D activities. Other Hanford facilities, including PFP, had difficulty using the basic CCR out of HNF-7098 when first implemented. Interpretation of the new guidelines indicated that many of the controls needed to be elevated to TSR level controls. Criterion 2 of the standard, requiring that the consequence of a criticality be examined for establishing the classification of a control, was not addressed. Upon in-depth review by PFP Criticality Safety staff, it was not clear that the programmatic interpretation of criterion 8C could be applied at PFP. Therefore, the PFP Criticality Safety staff decided to write their own CCR. The PFP CCR provides additional guidance for the evaluation team to use by clarifying the evaluation criteria in DOE-STD-3007-2007. In reviewing documents used in classifying controls for Nuclear Safety, it was noted that DOE-HDBK-1188, 'Glossary of Environment, Health, and Safety Terms', defines an Administrative Control (AC) in terms that are different than typically used in Criticality Safety. As part of this CCR, a new term, Criticality Administrative Control (CAC) was defined to clarify the difference between an AC used for criticality safety and an AC used for nuclear safety. In Nuclear Safety terms, an AC is a provision relating to organization and management, procedures, recordkeeping, assessment, and reporting necessary to ensure safe operation of a facility. A CAC was defined as an administrative control derived in a criticality safety analysis that is implemented to ensure double contingency. According to criterion 2 of Section IV, 'Linkage to the Documented Safety Analysis', of DOESTD-3007-2007, the consequence of a criticality should be examined for the purposes of classifying the significance of a control or component. HNF-PRO-700, 'Safety Basis Development', provides control selection criteria based on consequence and risk that may be used in the development of a Criticality Safety Evaluation (CSE) to establish the classification of a component as a design feature, as safety class or safety significant, i.e., an Engineered Safety Feature (ESF), or as equipment important to safety; or merely provides defense-in-depth. Similar logic is applied to the CACs. Criterion 8C of DOE-STD-3007-2007, as written, added to the confusion of using the basic CCR from HNF-7098. The PFP CCR attempts to clarify this criterion by revising it to say 'Programmatic commitments or general references to control philosophy (e.g., mass control or spacing control or concentration control as an overall control strategy for the process without specific quantification of individual limits) is included in the PFP DSA'. Table 1 shows the PFP methodology for evaluating CACs. This evaluation process has been in use since February of 2008 and has proven to be simple and effective. Each control identified in the applicable new/revised CSE is evaluated via the table. The results of this evaluation are documented in tables attached to the CCR as an appendix, for each CSE, to the base document.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

DEVELOPMENT OF AN ANTIFOAM TRACKING SYSTEM AS AN OPTION TO SUPPORT THE MELTER OFF-GAS FLAMMABILITY CONTROL STRATEGY AT THE DWPF

The Savannah River National Laboratory (SRNL) has been working with the Savannah River Remediation (SRR) Defense Waste Processing Facility (DWPF) in the development and implementation of an additional strategy for confidently satisfying the flammability controls for DWPF’s melter operation. An initial strategy for implementing the operational constraints associated with flammability control in DWPF was based upon an analytically determined carbon concentration from antifoam. Due to the conservative error structure associated with the analytical approach, its implementation has significantly reduced the operating window for processing and has led to recurrent Slurry Mix Evaporator (SME) and Melter Feed Tank (MFT) remediation. To address the adverse operating impact of the current implementation strategy, SRR issued a Technical Task Request (TTR) to SRNL requesting the development and documentation of an alternate strategy for evaluating the carbon contribution from antifoam. The proposed strategy presented in this report was developed under the guidance of a Task Technical and Quality Assurance Plan (TTQAP) and involves calculating the carbon concentration from antifoam based upon the actual mass of antifoam added to the process assuming 100% retention. The mass of antifoam in the Additive Mix Feed Tank (AMFT), in the Sludge Receipt and Adjustment Tank (SRAT), and in the SME is tracked by mass balance as part of this strategy. As these quantities are monitored, the random and bias uncertainties affecting their values are also maintained and accounted for. This report documents: 1) the development of an alternate implementation strategy and associated equations describing the carbon concentration from antifoam in each SME batch derived from the actual amount of antifoam introduced into the AMFT, SRAT, and SME during the processing of the batch. 2) the equations and error structure for incorporating the proposed strategy into melter off-gas flammability assessments. Sample calculations of the system are also included in this report. Please note that the system developed and documented in this report is intended as an alternative to the current, analytically-driven system being utilized by DWPF; the proposed system is not intended to eliminate the current system. Also note that the system developed in this report to track antifoam mass in the AMFT, SRAT, and SME will be applicable beyond just Sludge Batch 8. While the model used to determine acceptability of the SME product with respect to melter off-gas flammability controls must be reassessed for each change in sludge batch, the antifoam mass tracking methodology is independent of sludge batch composition and as such will be transferable to future sludge batches.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗