Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Predicting Turbulent Convective Heat Transfer in Three-Dimensional Duct Flows

The performance of an explicit algebraic stress model is assessed in predicting the turbulent flow and forced heat transfer in straight ducts, with square, rectangular, trapezoidal and triangular cross-sections, under fully developed conditions over a range of Reynolds numbers. Iso-thermal conditions are imposed on the duct walls and the turbulent heat fluxes are modeled by gradient-diffusion type models. At high Reynolds numbers (>/= 10(exp 5)), wall functions are used for the velocity and temperature fields; while at low Reynolds numbers damping functions are introduced into the models. Hydraulic parameters such as friction factor and Nusselt number are well predicted even when damping functions are used, and the present formulation imposes minimal demand on the number of grid points without any convergence or stability problems. Comparison between the models is presented in terms of the hydraulic parameters, friction factor and Nusselt number, as well as in terms of the secondary flow patterns occurring within the ducts.

Rokni, M.↗

Predicting Turbulent Convective Heat Transfer in Fully Developed Duct Flows

The performance of an explicit algebraic stress model (EASM) is assessed in predicting the turbulent flow and forced heat transfer in both straight and wavy ducts, with rectangular, trapezoidal and triangular cross-sections, under fully developed conditions. A comparison of secondary flow patterns. including velocity vectors and velocity and temperature contours, are shown in order to study the effect of waviness on flow dynamics, and comparisons between the hydraulic parameters. Fanning friction factor and Nusselt number, are also presented. In all cases. isothermal conditions are imposed on the duct walls, and the turbulent heat fluxes are modeled using gradient-diffusion type models. The formulation is valid for Reynolds numbers up to 10(exp 5) and this minimizes the need for wall functions that have been used with mixed success in previous studies of complex duct flows. In addition, the present formulation imposes minimal demand on the number of grid points without any convergence or stability problems. Criteria in terms of heat transfer and friction factor needed to choose the optimal wavy duct cross-section for industrial applications among the ones considered are discussed.

Rokni, Masoud↗

Multi-Timescale Integrated Dynamic and Scheduling Model (MIDAS-Solar)

Solar photovoltaic (PV) installations have experienced unprecedented growth in the United States. PV will become not only an energy producer but also a necessary provider of ancillary services at multiple timescales. Conventional methods to simulate power system operations - such as long-term production simulation (which typically considers schedules from hours to minutes by using an optimization framework) and short-term transient studies (which simulate dynamics from seconds to sub-seconds using state variables and differential equations) are not sufficient for studying the multiple-timescale variation of solar generation and its impact on system reliability. Long-term system economics and short-term system dynamics are highly coupled, particularly when the penetration level of renewable generation is extremely high, because the uncertainty and variability of solar generation will impact both power systems steady-state and dynamic performance. This project helps meet and exceed the Solar Energy Technologies Office goal of systems integration by directly addressing this stability and reliability challenge for electric grid planning and operation. This will be accomplished by developing temporally comprehensive, closed-loop simulation models that seamlessly simulate power systems operations from economic scheduling (day-ahead to hours) to dynamic response analysis (seconds to sub-seconds). Both a multi-timescale grid model and an integrated PV model will be developed in this project to accurately study the impacts of PV variability and uncertainty on system reliability at multiple timescales. Using quasi-dynamic simulation methods and data-driven security assessment (DSA) criteria will allow the dynamic characteristics of PV to be fed forward into longer-timescale scheduling models for a complete understanding of the effect of short-term PV dynamics on bulk systems operations (e.g., reserve scheduling and deployment). Upon completion of the proposed model, this project will help operators accurately assess system reliability by deploying energy and reserve scheduling under critical contingency conditions and studying interactions among all types of essential reliability services provided by modern PV power plants.

14 SOLAR ENERGY↗

Battery Storage Unlocked: Lessons Learned From Emerging Economies

The Clean Energy Ministerial (CEM) is a global forum that promotes policies and programs that advance clean energy technology. The CEM's mission is to bring together a community of global leaders to scale clean energy, amplifying the impact to all the sectors of the economy and applying a whole-of-society approach to meet collective climate and clean energy goals. At COP28 in Dubai, United Arab Emirates, the CEM announced the Supercharging Battery Storage Initiative as a vehicle to accelerate battery storage deployment around the world. The initiative supports countries around the world in co-creating strategies that enhance policy, regulation, supply chain, manufacturing, and financing solutions for battery energy storage deployment. Additionally, the initiative seeks to reduce the cost of the technology and promote diversified, sustainable, and secure supply chains (CEM n.d.). Through international collaboration, the initiative supports the integration of renewable energy globally, while securing the stability and reliability of the electricity grid.

batteries↗

Interactive Power to Frequency Dynamics Between Grid-Forming Inverters and Synchronous Generators in Power Electronics-Dominated Power Systems

With increased attention on grid-forming inverters as a power system stabilizing device during high shares of inverter-based resource operations, there is a present need for a transparent and methodical investigation of the inverted and direct power to frequency control capabilities and impacts of these devices on emerging power systems. Here, analysis of the frequency dynamics of the droop-controlled grid-forming inverter and the synchronous generator illuminates the inverted active power-frequency relationship and the frequency response order reduction, forming the basis for novel, nonlinear frequency control approaches. Device-level electromagnetic transient domain simulations corroborate the order-reduction findings, establish that a properly designed dc-side system has a negligible impact on power transfer and will not impede frequency regulation, and confirm the primary frequency response improvement with nonlinear control. Simulations of the 9- and 39-bus test systems validate the order reduction and associated decoupling of the nadir and rate of change of frequency in larger networks. Oscillatory mode analysis confirms the grid-forming benefit of increased damping; decreased damping is observed at shares above 80%, but not at 100%. Finally, simulations on a validated Maui power system model with a 96% of inverter-based resources model yield a trend toward a first-order response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of Grid-Forming and Grid-Following Inverters for Dynamic Simulation of Large-Scale Distribution Systems

Historically, distribution system planning studies mainly focused on steady state and quasi-steady state analysis, with limited attention paid to dynamic analysis. This paper develops three-phase, electromechanical models for both grid-forming and grid-following inverters, and integrates them into an open source, three-phase distribution network solver, thereby enabling dynamic simulation of large-scale, three-phase unbalanced distribution systems with high penetration of inverter-based DERs. The proposed inverter models are validated against electromagnetic simulation and field test data from the CERTS/AEP microgrid testbed, and simulated in an islanded 5252 node distribution system in the GridLAB-D simulation environment. Simulation verifies the effectiveness of the proposed inverter models for large-scale distribution system analysis. Finally, study results show that compared to traditional grid-following inverters, the high penetration of grid-forming inverters can improve the voltage and frequency stability of islanded distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Power-Hardware-in-the-Loop Evaluation of Inverter-Based Resources (IBRs)

Power-hardware-in-the-loop evaluation of IBRs has become more and more important as it provides reliable testing results to investigate the real responses of inverters with interconnected systems. A successful laboratory PHIL testing gives confidence of the hardware system to be deployed and de-risk technology integration prior to field deployment. So far, there are two important applications for PHIL evaluation: (1) test stability and functionality of large utility inverters into the system when it interconnects to the distribution systems/microgrids; and (2) test the collective grid service that inverters can provide to the grid. For the first application, the PHIL evaluation has high requirements for the stability and accuracy of the PHIL interface as the close-loop in digital real time simulator (DRTS) should replicate the actual current and voltage dynamics in the inverter. This is challenging because of the delays, sensing errors, nonlinearities of inverters, and hardware bandwidth limitations of the elements in the HIL loop. For the second application, multiple inverters will be tested resulting in multiple PCCs, which naturally causes competing dynamics and oscillations among hardware inverters if traditional PHIL interface is used. Therefore, new PHIL interface should be developed to compromise between stability and accuracy and represent the dispatched grid services for the hardware inverters. In this presentation, we will share our latest work in developing PHIL interface in these two applications to address the two key challenges.

DERMS↗

Small-Signal Stability Constrained Optimal Power Flow of Inverter-Dominated Power Systems with Flexible Operation Mode Selection

Given the intermittence and low inertia nature of inverter-based resources (IBRs), modern power systems with high penetration of IBRs challenge the conventional optimal power flow (OPF) analysis and the system may experience unexpected failures if stability constraints are not incorporated. This study proposes a small-signal stability-constrained OPF (SSSC-OPF) with flexible operation mode selection between grid-forming (GFM) and grid-following (GFL) modes for IBRs to address these challenges. The approach aims to maintain system stability with a sufficient stability margin while minimizing operation costs. The effectiveness of the proposed method is validated through extensive case studies on the IEEE 14-bus system. The results demonstrate that the proposed method is able to support system-level power flow analysis, reduce generation costs, and ensure stability under various disturbances.

grid-following↗

Subgrid Treatment of Spacer Grids in the 2D/1D Subplane Approach

Recent efforts have focused on improving the performance of the 2D/1D subplane implementation in MPACT. One of the developments recently added, presented here, focuses on treating spacer grids using a subgrid approach within each subplane, avoiding the extra computation and potentially improving stability issues that can be present by explicitly modeling the spacer grid with a separate MOC plane. From the cases analyzed, it seems that the approach does a sufficient job of maintaining the accuracy of explicitly meshing the spacer grid (<10 pcm and <1% max pin power error) while offering relatively modest performance gains. Overall, the success of the approach with spacer grids opens up possibilities to apply similar approaches to other structural components, particularly those in the axial reflectors to reduce the number of MOC planes and overall computational burden.

Stimpson, Shane G.↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration: Preprint

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

Distribution-Connected PV's Response to Voltage Sags at Transmission-Scale

The ever increasing amount of residential- and commercial-scale distribution-connected PV generation being installed and operated on the U.S.'s electric power system necessitates the use of increased fidelity representative distribution system models for transmission stability studies in order to ensure the continued safe and reliable operation of the grid. This paper describes a distribution model-based analysis that determines the amount of distribution-connected PV that trips off-line for a given voltage sag seen at the distribution circuit's substation. Such sags are what could potentially be experienced over a wide area of an interconnection during a transmission-level line fault. The results of this analysis show that the voltage diversity of the distribution system does cause different amounts of PV generation to be lost for differing severity of voltage sags. The variation of the response is most directly a function of the loading of the distribution system. At low load levels the inversion of the circuit's voltage profile results in considerable differences in the aggregated response of distribution-connected PV Less variation is seen in the response to specific PV deployment scenarios, unless pushed to extremes, and in the total amount of PV penetration attained. A simplified version of the combined CMPLDW and PVD1 models is compared to the results from the model-based analysis. Furthermore, the parameters of the simplified model are tuned to better match the determined response. The resulting tuning parameters do not match the expected physical model of the distribution system and PV systems and thus may indicate that another modeling approach would be warranted.

14 SOLAR ENERGY↗

Modeling Primary Frequency Response for Grid Studies

For the electric power grid, maintaining nearly constant frequency is important measure of system reliability and stability. Primary frequency response (PFR) is one of the important reserve services used by grid operators to uphold steady frequency. Modeling PFR is historically rare in grid integration and planning studies, but could become more importantly with greater deployment of non-synchronous generators. In this work, we illustrate how a PFR constraint can be implemented into production cost models, which are a key component of grid planning studies. We also discuss the complexities and nuances associated with PFR modeling and provide results of a case study implementing PFR in a section of the western U.S. power grid.

14 SOLAR ENERGY↗

Frequency Recovery in Power Grids Using High-Performance Computing

Maintaining electric power system stability is paramount, especially in extreme contingencies involving unexpected outages of multiple generators or transmission lines that are typical during severe weather events. Such outages often lead to large supply-demand mismatches followed by subsequent system frequency deviations from their nominal value. The extent of frequency deviations is an important metric of system resilience, and its timely mitigation is a central goal of power system operation and control. This paper develops a novel nonlinear model predictive control (NMPC) method to minimize frequency deviations when the grid is affected by an unforeseen loss of multiple components. Our method is based on a novel multi-period alternating current optimal power flow (ACOPF) formulation that accurately models both nonlinear electric power flow physics and the primary and secondary frequency response of generator control mechanisms. We develop a distributed parallel Julia package for solving the large-scale nonlinear optimization problems that result from our NMPC method and thereby address realistic test instances on existing high-performance computing architectures. Our method demonstrates superior performance in terms of frequency recovery over existing industry practices, where generator levels are set based on the solution of single-period classical ACOPF models.

nonlinear model predictive control↗

Enhancing the Flexibility of Generation of Run-Of-the-River Hydro Power Plants

Run-of-the-River Hydro Power Plants (ROR HPPs) output can be characterized as fixed and predictable output with low cost of both installation and operation. ROR HPP generation is proportional to the water flow and cannot be adjusted to provide inertia to the grid, which is critical to power systems stability. Hence ROR HPP can only participate in low profit energy markets and not in the high profit ancillary service market. With the advances in energy storage, they can help build a synthetic energy reservoir. The combined operation of ROR HPPs and energy storage are capable of both ramping and variable power output, allowing participation in the ancillary service markets. However, energy storage technologies such as supercapacitors and flywheels, which are power dense can quickly charge/discharge within a short duration. Energy dense storage technologies such as batteries can provide long duration energy injection while the maximum ramping rate is much lower than power dense energy storage. In order to provide long duration fast ramping capability, Hybrid Energy Storage Systems (HESSs) including both power and energy dense energy storage are proposed to be integrated to enable the flexible operation of ROR HPP. Power dense energy storage with quick burst of energy can assist in regulation, whereas energy dense storage can provide energy balance over larger time. In this paper, the properties of different types of energy storage including the ramping rate, affordable energy storage capacity, thermal management, etc. are analyzed. The size of each type of energy storage is determined to ensure optimal combination of HESS and ROR HPP. A generic Front End Controller (FEC) is developed and customized for ROR HPP to provide real time control and cohesive operation of multiple units. FEC serves as the interface between utility management systems and ROR HPPs to ensure their integration with the centralized controls. Using the Automatic Generation Control (AGC) signal received from grid operator, FEC optimizes the ROR HPP turbine and HESS so that the aggregated generation can satisfy the market needs. Based on the study, system operator can acquire extra inertia support for system stability, and the ROR HPP operators can enhance their revenues by participating in wider market avenues.

13 HYDRO ENERGY↗

Inverter-Based Power Systems From an Electric Circuit Perspective

This presentation reports a twin circuit theory that enables us to interpret power system dynamics from a electric circuit perspective. Our proposed twin circuit theory can roughly prove the dissipating energy flow (DEF) method, and shows the positive impacts of well-designed grid-forming (GFM) inverters on power systems stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗