Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grazing incidence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Development of Constellation-X Optics Technologies at MSFC

One of the major technological challenges for the Constellation X-ray Mission is the development of light-weight, high-resolution, grazing-incidence optics. NASA's Marshall Space Flight Center is developing and evaluating candidate technologies, based upon full-shell replication off precision mandrels. Here we report on recent progress in meeting the weight and imaging-performance requirements, using very thin, high-strength electroformed nickel alloys. In addition, we briefly describe MSFC's optics fabrication, metrology, and x-ray test facilities.

Odell, S. L.↗

Interferometry in the Extreme Ultraviolet and X-Ray

We report on demonstration of an x-ray interferometer that uses plane mirrors at grazing incidence to create interference fringes in the extreme ultraviolet and soft x-ray portions of the spectrum. X-ray interferometry has historically been implemented through narrow band, diffractive systems that split the wavefront. Our system, by using two separate optical channels to create interference from two areas of the wavefront, has broad band response and much higher efficiency. We discuss some applications of this technique to astronomy and microscopy including the possibility of eventually capturing a micro-arcsecond image of a black hole.

Cash, W.↗

Cylindrical Optic Polishing Dwell Time Optimization

The Constellation-X x-ray telescope consists of replicated grazing incidence optics. The polishing of the "master' mandrel is accomplished by moving a polishing tool along a helical path on the surface of this almost cylindrical surface. The measurement of the surface is, however, performed along "axial" scan lines which intercept this helical path. This approach to polishing and measuring permits a relatively simple scheme to be implemented for the determination of the optimal dwell times of the polishing tool. These optimal dwell times are determined by a deconvolution which approaches the problem as a linear programming problem and uses the simplex method. This approach maximizes the amount of material removed at any point subject to inequality constraints. The effects of using these "optimum" dwell times is to significantly improve the "tools" effectiveness at removing the higher spatial frequencies while staying (strictly) within the bounds and constraints imposed by the hardware. In addition the "ringing" at the edges of the optic, frequently present in deconvolution problems, is completely eliminated.

Waluschka, Eugene↗

Development of Constellation-X Optics Technologies at MSFC

One of the major technological challenges for the Constellation X-ray Mission is the development of light-weight, high-resolution, grazing-incidence optics. NASA's Marshall Space Flight Center is developing and evaluating candidate technologies, based upon full-shell replication off precision mandrels. Here we report on recent progress in meeting the weight and imaging-performance requirements, using very thin, high- strength electroformed nickel alloys, In addition, we briefly describe MSFC's optics fabrication, metrology, and x-ray test facilities.

Ramsey, B. D.↗

HERO: High Energy Replicated Optics for a Hard-X-Ray Balloon Payload

We are developing high-energy grazing-incidence replicated optics for a balloon-borne hard-x-ray telescope. When completed, the instrument will have 170 cm2 of effective collecting area at 40 keV and 130 square cm at 60 keV with <= 30 arc seconds half power diameter. This payload will offer unprecedented sensitivity in the hard-x-ray region, with around 250 microCrab sensitivity on long-duration flights and 50-100 microCrab on ultra- long-duration balloon missions The payload consists of 16 mirror modules, each with 14 nested mirrors made from a high-strength nickel alloy, and a corresponding array of 16 focal plane detectors. An engineering demonstration flight is scheduled for the Spring of 2000, using just two mirror modules each with 3 shells, above a pair of gas-scintillation-proportional counters. This flight is intended to test a newly designed gondola pointing and aspect system and the stability of the optical bench design. The first scientific flight of the full payload is scheduled for the Fall of 2002. Full details of the payload and its capabilities will be presented together with data from various mirror-module tests. If available data from the first flight will also be presented.

Ramsey, B.↗

Development of Constellation-X Optics Technologies at MSFC

One of the major technological challenges for the Constellation X-ray Mission is the development of light-weight, high-resolution, grazing-incidence optics. NASA's Marshall Space Flight Center is developing and evaluating candidate technologies, based upon full-shell replication off precision mandrels. Here we report on recent progress in meeting the weight and imaging-performance requirements, using very thin, high-strength electroformed nickel alloys. In addition, we briefly describe MSFC's optics fabrication, metrology, and x-ray test facilities.

ODell, S. L.↗

The CHANDRA X-Ray Observatory: Thermal Design, Verification, and Early Orbit Experience

The CHANDRA X-ray Observatory (formerly AXAF), one of NASA's "Great Observatories" was launched aboard the Shuttle in July 1999. CHANDRA comprises a grazing-incidence X-ray telescope of unprecedented focal-length, collecting area and angular resolution -- better than two orders of magnitude improvement in imaging performance over any previous soft X-ray (0.1-10 keV) mission. Two focal-plane instruments, one with a 150 K passively-cooled detector, provide celestial X-ray images and spectra. Thermal control of CHANDRA includes active systems for the telescope mirror and environment and the optical bench, and largely passive systems for the focal plans instruments. Performance testing of these thermal control systems required 1-1/2 years at increasing levels of integration, culminating in thermal-balance testing of the fully-configured observatory during the summer of 1998. This paper outlines details of thermal design tradeoffs and methods for both the Observatory and the two focal-plane instruments, the thermal verification philosophy of the Chandra program (what to test and at what level), and summarizes the results of the instrument, optical system and observatory testing.

Boyd, David A.↗

First Images from HERO: A Hard-X-Ray Focusing Telescope

We are developing a balloon-borne hard-x-ray telescope that utilizes grazing incidence optics. Termed HERO, for High-Energy Replicated Optics, the instrument will provide unprecented sensitivity in the hard-x-ray region and will achieve milliCrab-level sensitivity in a typical 3-hour balloon-flight observation and 50 microCrab sensitivity on ultra-long-duration flights. A recent proof-of-concept flight, featuring a small number of mirror shells captured the first focused hard-x-ray images of galactic x-ray sources. Full details of the payload, its expected future performance and its recent measurements are provided.

Ramsey, Brian D.↗

Calibration of a Vertical-Scan Long Trace Profiler at MSFC

The long trace profiler (LTP) is the instrument of a choice for the surface figure measurement of grazing incidence mirrors. The modification of conventional LTP, the vertical-scan LTP, capable of measuring the surface figure of replicated shell mirrors is now in operation at Marshall Space Flight Center. Sources of systematic error for vertical-scan LTP are discussed. Calibration method using a test flat mirror and results of measurements are presented.

Gubarev, Mikhail↗

Relationship between Jovian Hectometric Attenuation Lanes And Io Volcanic Activity

Within the Galileo plasma wave instrument data a narrow (in frequency) attenuation band is seen in the hectometric (HOM) emission that varies in frequency with system III longitude. This attenuation lane is believed to be the result of near-grazing incidence or coherent scattering of radio emission near the outer edge of the Io torus, i.e., when the ray path is nearly tangent to an L shell containing the Io flux tube. Such a process should, therefore, be enhanced when the Io volcanic activity is increased and the Io flux tube has enhanced density. We have performed a systematic study of the existing Galileo radio emission data in an effort to determine the phenomenology and frequency of occurrence of the attenuation lanes and the association, if any, with published volcanic activity of Io. Our results indicate that the attenuation lanes are present almost all of the time but are enhanced on occasion. The best examples of attenuation lanes occur when Galileo is within approximately 65 R(sub J) of Jupiter and thus are probably more apparent because of the increased signal-to-noise ratio of the radio receivers. The lack of continuous monitoring of Io activity and the lack of known activity on the anti-Earthward side of Io are problematic and make detailed correlation with radio emission very difficult at this time. Nevertheless, if the data are displayed for periods when the spacecraft is within 65 R(sub J) (i.e., for each perijove pass), then the highest-contrast lanes occur on most passes when the Io volcanic activity is also high for that pass. These results support our current understanding of attenuation lane formation and suggest that future efforts can be made to better understand the interaction of HOM emission with the Io flux tube.

Menietti, J. D.↗

A Focal Plane Stellar X-Ray Polarimeter for SXG

The Stellar X-Ray Polarimeter (SXRP) is the only X-ray polarimeter designed to view astrophysical sources that is currently scheduled to be flown. The SXRP is one of eight astronomical X-ray instruments that intended to be flown at the focal plane of the two SODART large-area metal-foil grazing-incidence X-ray telescopes on the Russian Spectrum-Roentgen-Gamma (SRG) mission. The engineering model of the SXRP was delivered to Russia in February 1994. Construction of the flight model (FM) is complete. The SXRP-FM is currently in storage at the Smithsonian Astrophysical Observatory and will be delivered when required.

Kaaret, P.↗

A Focal Plane Stellar X-Ray Polarimeter for SXG

The Stellar X-Ray Polarimeter (SXRP) is the only X-ray polarimeter designed to view astrophysical sources that is currently scheduled to be flown. The SXRP is one of eight astronomical X-ray instruments intended to be flown at the focal plane of the two SODART large-area metal-foil grazing-incidence X-ray telescopes on the Russian Spectrum-Roentgen-Gamma (SRI) mission. The engineering model of the SXRP was delivered to Russia in February 1994. Construction of the flight model (FM) is complete. The SXRP-FM is currently in storage at SAO.

Kaaret, P.↗

Development of High Resolution Mirrors and Cd-Zn-Te Detectors for Hard X-ray Astronomy

We describe the fabrication and implementation of a high-resolution conical, grazing- incidence, hard X-ray (20-70 keV) telescope. When flown aboard stratospheric balloons, these mirrors are used to image cosmic sources such as supernovae, neutron stars, and quasars. The fabrication process involves generating super-polished mandrels, mirror shell electroforming, and mirror testing. The cylindrical mandrels consist of two conical segments; each segment is approximately 305 mm long. These mandrels are first, precision ground to within approx. 1.0 micron straightness along each conical segment and then lapped and polished to less than 0.5 micron straightness. Each mandrel segment is the super-polished to an average surface roughness of approx. 3.25 angstrom rms. By mirror shell replication, this combination of good figure and low surface roughness has enabled us to achieve 15 arcsec, confirmed by X-ray measurements in the Marshall Space Flight Center 102 meter test facility. To image the focused X-rays requires a focal plane detector with appropriate spatial resolution. For 15 arcsec optics of 6 meter focal length, this resolution must be around 200 microns. In addition, the detector must have a high efficiency, relatively high energy resolution, and low background. We are currently developing Cadmium-Zinc-Telluride fine-pixel detectors for this purpose. The detectors under study consist of a 16x16 pixel array with a pixel pitch of 300 microns and are 1 mm and 2 mm thick. At 60 keV, the measured energy resolution is around 2%.

Ramsey, Brian D.↗

A Focal Plane Stellar X-Ray Polarimeter for SXG

This report covers progress on a grant for the Stellar X-Ray Polarimeter (SXRP). SXRP is the only X-ray polarimeter designed to view astrophysical sources that is currently scheduled to be flown. The SXRP is one of eight astronomical X-ray instruments that intended to be flown at the focal plane of the two SODART large-area metal-foil grazing-incidence X-ray telescopes on the Russian Spectrum-Roentgen-Gamma (SRG) mission.

Christensen, Larry↗

Equal-Curvature X-Ray Telescopes

We introduce a new type of x-ray telescope design; an Equal-Curvature telescope. We simply add a second order axial sag to the base grazing incidence cone-cone telescope. The radius of curvature of the sag terms is the same on the primary surface and on the secondary surface. The design is optimized so that the on-axis image spot at the focal plane is minimized. The on-axis RMS (root mean square) spot diameter of two studied telescopes is less than 0.2 arc-seconds. The off-axis performance is comparable to equivalent Wolter type 1 telescopes.

Saha, Timo T.↗

Proof Test Diagrams for a Lithia-Alumina-Silica Glass-Ceramic

The glass-ceramic (Zerodur, Schott Glaswerke, Mainz, Germany) contains 70% to 78% by weight crystalline phase of high-quartz structure with a mean crystal size of 50-55 nm. The vitreous phase has a positive thermal expansion coefficient which is practically balanced by the negative coefficient of the crystalline phase. This results in a material which can maintain longitudinal stability during thermal cycling. This was one of the reasons for its choice as the material for the grazing incidence mirrors for the Chandra X-Ray Facility. Brittle materials such as glass and glass-ceramics which exhibit slow crack growth and subsequent fast fracture to failure exhibit a time dependence in strength. The decrease in strength for a constant applied load is known as static fatigue. In many cases, environment plays a major role in the material lifetime. It has been shown for silicate glasses that crack velocity will increase as the amount of water vapor in the environment surface finish and rate of loading. A rough surface finish leads to a lower tensile strength than for an optically polished surface. The strength of glass is observed in general to increase with increasing load rate. This phenomena is known as dynamic fatigue. This was observed for Zerodur by Tucker and Gent and Tucker in previous dynamic fatigue studies, in which lifetimes were obtained. All of the above named factors need to be considered when glass is to be used in load bearing applications.

Tucker, Dennis S.↗

Figure Measurements of High-Energy-X-Ray Replicated Optics

We are developing grazing incidence x-ray optics for a balloon-borne hard-x-ray telescope (HERO). The HERO mirror shells are fabricated using electroform-nickel replication off super-polished cylindrical mandrels. One of the sources for mirror resolution error is departure of the shell figure from prescription. We have modified a Vertical-scan Long Trace Profilometer (VLTP) in order to measure the figure of the inner surface of the HERO mirror shells for diameters as small as 76 mm. Mirror alignment method and sources for systematic errors will be discussed. Comparison of figure metrology of the mandrel and the shells will be presented together with results from x-ray tests.

Gubarev, Mikhail↗

Equal-Curvature X-ray Telescope Designs for Constellation-X Mission

We study grazing incidence Equal-Curvature telescope designs for the Constellation-X mission. These telescopes have nearly spherical axial surfaces. The telescopes are designed so that the axial curvature is the same on the primary and secondary. The optical performance of these telescopes is for all practical purposes identical to the equivalent Wolter telescopes.

Saha, Timo T.↗