Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gamma detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

The Probing In-Situ With Neutron and Gamma Rays (PING) Instrument for Planetary Composition Measurements

The Probing In situ with Neutrons and Gamma rays (PING) instrument (formerly named PNG-GRAND) [I] experiment is an innovative application of the active neutron-gamma ray technology successfully used in oil field well logging and mineral exploration on Earth over many decades. The objective of our active neutron-gamma ray technology program at NASA Goddard Space Flight Center (NASA/GSFC) is to bring PING to the point where it can be flown on a variety of surface lander or rover missions to the Moon, Mars, Venus, asteroids, comets and the satellites of the outer planets and measure their bulk surface and subsurface elemental composition without the need to drill into the surface. Gamma-Ray Spectrometers (GRS) have been incorporated into numerous orbital planetary science missions. While orbital measurements can map a planet, they have low spatial and elemental sensitivity due to the low surface gamma ray emission rates reSUlting from using cosmic rays as an excitation source, PING overcomes this limitation in situ by incorporating a powerful neutron excitation source that permits significantly higher elemental sensitivity elemental composition measurements. PING combines a 14 MeV deuterium-tritium Pulsed Neutron Generator (PNG) with a gamma ray spectrometer and two neutron detectors to produce a landed instrument that can determine the elemental composition of a planet down to 30 - 50 cm below the planet's surface, The penetrating nature of .5 - 10 MeV gamma rays and 14 MeV neutrons allows such sub-surface composition measurements to be made without the need to drill into or otherwise disturb the planetary surface, thus greatly simplifying the lander design, We are cun'ently testing a PING prototype at a unique outdoor neutron instrumentation test facility at NASA/GSFC that provides two large (1.8 m x 1.8 m x ,9 m) granite and basalt test formations placed outdoors in an empty field, Since an independent trace elemental analysis has been performed on both these Columbia River basalt and Concord Gray granite materials, these large samples present two known standards with which to compare PING's experimentally measured elemental composition results, We will present both gamma ray and neutron experimental results from PING measurements of the granite and basalt test formations in various layering configurations and compare the results to the known composition.

Parsons, A.↗

First Year PIDDP Report on gamma-ray and x-ray spectroscopy: X-ray remote sensing and in situ spectroscopy for planetary exploration missions and gamma-ray remote sensing and in situ spectroscopy for planetary exploration missions

Detectors that will be used for planetary missions must have their responses calibrated in a reproducible manner. In addition, it is important to characterize a detector system at uneven portions of its life cycle, for example after exposure to different amounts of radiation. A calibration and response characterization facility has been constructed at Schlumberger-Doll Research for all types of gamma- and x-ray detectors that may be used for planetary measurement. This facility is currently being tested. Initial use is expected for the MARS 94 detectors. The facility will then also be available for calibrating other detectors as well as arrays of detectors such as the NEAR detector with its central Nal(TI) crystal surrounded with a large BGO crystal. Cadmium telluride detectors are investigated for applications in space explorations. These detectors show an energy resolution of 5 keV for the 122 keV 57Co line. Earlier reported polarization effects are not observed. The detectors can be used at temperatures up to 100 C, although with reduced energy resolution. The thickness of standard detectors is limited to 2 mm. These detectors become fully efficient at bias voltages above 200 V. Initial results for a 1 cm thick detector show that the quality of the material is inferior to the thinner standard detectors and hole trapping affects the pulse height. A detailed characterization of the detector is in progress. Prototypes of photomultipliers based on a Channel Electron Multiplier (CEM) are being built to study their performance. Such photomultipliers promise better timing characteristics and a higher dynamic range while being more compact and of lower in weight.

Mahdavi, M.↗

Evidence for ionization damage in mid-wave infrared nBn detectors

The effects of 63 MeV proton and 60Co gamma irradiation on the operation of 4.3 μm cutoff nBn photodetectors are demonstrated separately, and both are shown to yield a total ionizing dose (TID) effect. The effect is shown here in an InAsSbBi nBn detector and has been observed in other bulk alloy nBn detectors, and is unusual as it is notably absent in superlattice nBn detectors. The non-antireflection coated detectors exhibit a pre-radiation quantum efficiency of 17% at 3.3 μm wavelength and a dark current density of 50 μA/cm2, or roughly 300× the Rule 07 expectation, at their ideal operating voltage of −0.4 V bias at 150 K. Step-wise proton irradiation and in situ measurement indicate that the dark current increases to about 400× Rule 07 at the highest proton dose level of 150 krad(Si) (9.10 × 1011 p+/cm2), while the quantum efficiency is degraded at a relatively faster rate than the majority of analogous detectors characterized by our lab. Both the photocurrent and dark current are also shown to exhibit a turn-on voltage magnitude reduction of 100 mV following either gamma or proton irradiation, a trend which is attributable to negative trapped charge at the barrier interface (TID effect). This theory is further supported by an observed capacitance density magnitude reduction with dose and affirmed with Silvaco TCAD simulations. Following both proton exposure and subsequent anneal and gamma exposure and subsequent anneal; dark current, photocurrent, and CV all approach their pre-radiation baseline values.

Physics↗

Reassessment of PHDS Fulcrum40h High Purity Germanium (HPGe) Detector System Performance

This report presents a comprehensive evaluation of the updated PHDS Fulcrum40h High Purity Germanium (HPGe) detector system, benchmarking its performance, usability, and software capabilities against the current National Nuclear Security Administration (NNSA) Nuclear Emergency Support Team (NEST) HPGe Detector System Requirements Document. Systematic measurements were conducted using a single Fulcrum40h detector to assess key parameters including gamma efficiency and resolution, neutron detection efficiency, gamma pulse-pileup response, and gamma-to-neutron crosstalk. The Fulcrum40h system, acquired in August 2022, has undergone recent updates by PHDS to address deficiencies identified following the initial NEST requirements release. The results provide critical insights into the detector’s operational capabilities and compliance with NNSA NEST standards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Is the Narrow E-Peak Distribution of Gamma-Ray Bursts Real?

Over the performance period of the research grant, the authors conducted a study of the role that the detector response plays in the detection of gamma-ray bursts. The goal of the study was to determine whether the fact that the gamma-ray bursts observed by the BATSE instrument on the Compton Gamma-ray Observatory are characterized by approximately the same characteristic energy is a consequence of the instrument's characteristics, or whether the distribution is a physical attribute of gamma-ray bursts. The authors succeeded in showing that instrumental effects are mild, and that the observed characteristic energy is a physical attribute of bursts. In the course of this research, the authors ported the computer code for calculating the BATSE detector response matrices to the Sun Solaris platform, and created a version of the code that runs under any platform that supports a Fortran 77 compiler with DEC extensions. This code has already been used by other investigators to analyze BATSE data. The authors constructed a Monte Carlo simulation of the BATSE burst trigger, with which they determined the efficiency of detecting a burst as a function of characteristic burst spectral energy. The results were then applied to BATSE observations to determine the physical model for the distribution of burst characteristic energies.

Brainerd, Jerome J.↗

Dipole analysis on EGRET data of extragalactic gamma ray background radiation

A dipole analysis on the EGRET (Energetic Gamma-Ray Experimental Telescope) data seems to be one of the numerous subjects that can be investigated for the extragalactic gamma ray background radiation. By the end of the first one and half years after launch, the all-sky survey program of GRO (Gamma Ray Observatory) will be completed. The EGRET detector will cover the full sky area fairly well by that time. A set of gamma ray data suitable for dipole moment calculations will be available. Furthermore, there now exist in the literature several dipole anisotropy results calculated for optical and infrared observations on the distribution of galaxies in the full sky. The results of dipole moment analysis from gamma ray observation can be compared with those at other wavebands, and hopefully some deeper understanding can be gained on the large scale structure of the Universe.

Lin, Ying-Chi↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

A cosmic and solar X-ray and gamma-ray instrument for a scout launch

An overview is presented for a set of simple and robust X-ray and gamma ray instruments which have both cosmic and solar objectives. The primary solar scientific objective is the study of the beaming of energetic electrons and ions in solar flares. The instrument will measure spectra and polarization of flare emissions up to 10 MeV. At X-ray energies both the directly emitted flux and the reflected albedo flux will be measured with a complement of six X-ray sensors. Each of these detectors will have a different high Z filter selected to optimize both the energy resolution and high rate capabilities in the energy band 10 to 300 keV. At energies greater than 100 keV seven 7.6 x 7.6 cm NaI and a set of 30 concentric plastic scattering detectors will record the spectra and polarization of electron bremsstrahlung and nuclear gamma rays. All of the components of the instrument are in existence and have passed flight tests for earlier space missions. The instrument will use a spinning solar oriented Scout spacecraft. The NaI detectors will act as a self-modulating gamma ray detector for cosmic sources in a broad angular band which lies at 90 degrees to the Sun-Earth vector and hence will scan the entire sky in 6 months.

Forrest, D. J.↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the interpretation of gamma-ray burst continua and possible cyclotron absorption lines

It is pointed out that most gamma-ray bursts have spectra that are fit by an optically thin thermal bremsstrahlung shape. The small emitting volume implied by the observation of spectral features identified as cyclotron absorption lines from a 10 to the 12th Gauss field is shown to prevent thermal bremsstrahlung from providing sufficient luminosities to account for the observed fluxes unless the optical depth to Compton scattering is large. It is also demonstrated that complicated detector response functions can introduce artifacts that mimic absorption features below 60 keV unless the absolute gain of the detector is established and correctly applied in analysis. Comparing the continuum as observed by the Berkeley/Los Alamos ISEE-3 gamma-ray detector with the continuum observed by the Konus (Mazets et al. 1981) experiments, a lack of agreement is found, suggesting that the gain of one of these experiments may be incorrect.

Fenimore, E. E.↗

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AMS / BARC Joint Survey Addendum Technical Report

This report details the data analysis results from data collected during the September-October 2019 joint survey series between the Department of Energy (DOE) National Nuclear Security Administration (NNSA) Aerial Measuring System (AMS) asset, and the Government of India’s Department of Atomic Energy (DAE) Bhabha Atomic Research Centre (BARC). This joint survey series took place at the Nevada National Security Site (NNSS), areas of public land in Southern Nevada, and at the DOE Office of Legacy Management (LM) Large Area Calibration Pads (LACP) at the Grand Junction Regional Airport in Grand Junction, CO. The data detailed in this report were gathered at the LACP. More details regarding the setup of these surveys and personnel involvement can be found in the AMS / BARC Joint Survey Summary Report. The data from the LACP collected by AMS are consistent with past data collection campaigns at the LACP. The AMS Bell 412 (B412) helicopter, equipped with both the standard AMS thallium-doped sodium iodide (NaI(Tl)) 2"x4"x16" 12-detector system and a subset of the BARC Aerial Gamma Spectroscopy System (AGSS) consisting of two independent 3"x3"cylindrical NaI(Tl) detectors, measured each of the five calibration pads for a minimum of 10 minutes. After the helicopter measurements, a pressurized ion chamber (PIC) was used to directly measure radiation exposure rates on each of the pads for a period 5 minutes. The geophysical calibration procedure published by the International Atomic Energy Agency (IAEA) (Erdi-Krausz et al. 2003) was used to determine the spectral stripping sensitivity matrix for naturally occurring radiological material (NORM). The sensitivity matrix is consistent with the AMS long term average. Additionally, the PIC data was used to calibrate the AMS system for exposure rate. The results of the exposure rate analysis are also consistent with AMS long-term averages.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A 200-MeV pi(+) induced nucleon removal from 24Mg

Nuclear gamma rays in coincidence with outgoing pions and/or protons following single nucleon removal from Mg24 by 200 MeV pi(+) were detected with Ge(Li) detectors. Differential cross sections are reported for gamma rays from the first excited mirror states of Na23 to Mg23 in coincidence with positive pions and/or protons detected in particle telescopes at 30, 60, 90, 120 and 150 deg; angle integrated absolute cross sections and cross section ratios sigma (Mg23/sigma (Na23) are calculated. These results are compared with the predictions of the one step quasifree (OSQF), the intranuclear cascade (INC), and the nucleon charge exchange (NCX) reaction models. The OSQF and the INC calculations generally agree with the experimental results, while the NCX calculations are in disagreement.

Joyce, D.↗

In situ monitoring of the stopped muon flux at Mu2e

The specific object of Mu2e search is the neutrino-less coherent $\mu^-\rightarrow e^-$ conversion in the field of an aluminum nucleus and the signal is a monoenergetic electron of energy $ \approx 104.97$ MeV. This process is forbidden in the Standard Model but allowed in many of its extensions: with minimal changes to include neutrino masses and oscillation, the Branching Ratio of this process, or the similarly interesting $\mu\rightarrow e \gamma$ decay, is expected to be of the order of $\mathcal{O}(10^{-54})$. Values like these are below any currently achievable experimental sensitivity, and the observation of a signal would be unambiguous evidence of New Physics. The upper limit on the muon conversion was set by SINDRUM II at $7\times10^{-13}$ (90\% C.L.) and the goal of the Mu2e collaboration is an improvement of 4 order of magnitudes.\\ The Mu2e experiment can be conceptually divided into three stages: interaction of the primary proton pulse with the tungsten target a nd production of $\pi$ and $\mu$; collection and transport of the produced particles down to the aluminum stopping target; interaction with the stopping target and measurement of the output particles. The measurement of the stopped muon flux is of cardinal importance for the normalization of the Mu2e results. The baseline design includes two detectors developed to measure this flux, counting $\gamma$ emitted by the muonic atoms: HPGe and LaBr$_3$(Ce). The studies performed by the Mu2e Collaboration show that these two systems can be reliably used to determine the overall normalization.\\ The number of stopped muons is proportional to the number of protons on target, which itself depends on the extraction system for the proton beam. The Mu2e beam delivery system will use a resonant extraction to create the proton pulses and this method is characterized by intensity fluctuations on the time scale of milliseconds. These fluctuations, aside from the proportional fluctuation of t he number of muons, have a non-trivial impact on the overall! performance of the apparatus. For example, higher intensity proton bunches translate into higher veto rates by the Cosmic Rays Veto system, which is triggered by secondary particles generated by the proton interaction. Another example is the effect of the instantaneous luminosity on the reconstruction efficiency: higher intensity translates into higher detector occupancy, which in turn reduces the reconstruction efficiency.\\ The two cited detectors encounter limitations when trying to monitor the flux at the millisecond timescales: HPGe is by construction a slow detector while the rate of emission of the $\gamma (1809\textrm{ keV})$ the LaBr$_3$(Ce) will measure is too low. As of today, no system allows to monitor these fluctuations and the goal of this Thesis is to try filling this gap. The method we developed to monitor the fluctuations of the stopped muon flux, and by extension, the fluctuation in the proton pulses intensity is based on counting the number of muons capt ured in the stopping target by counting the number of protons produced in the process of the nuclear muon capture. This is one of the possible processes a stopped muon can undergo and it can lead to the ejection of charged particles.\\ The reconstruction algorithms were developed by the Mu2e collaboration with the explicit (and sometimes implicit) aim to reconstruct tracks of electrons in an energy range of a conversion electron. The protons we are interested in behave quite differently from these electrons and the cardinal task of this study has been to tailor the reconstruction routines to these particles. This has been done by analyzing simulated events consisting of a single proton to optimize the procedure and understand the features of these tracks. A major difference with respect to the electrons is the non-relativistic nature of $100\div300$ MeV$/c$ protons: accounting for the low velocity is both a challenge and a unique signature of the tracks.\\ The use of a pulse d beam and the need to allow produced $\pi$ to decay and $\m! u$ to int! eract in the stopping target forces the definition of a Mu2e \textit{event}: an event is comprised by everything which happens in a $1.7\ \mu$s window between the incidence two consecutive proton pulses. This means that the reconstruction will be performed in an environment crowded by many different particles. The next step of this study has been to estimate the performance of the method in a fully-fledged Mu2e simulated event and to study what kind of selections would improve it.\\ Our results are satisfactory since the number of reconstructed protons is significant (few per event), and show that a monitor on the timescale of milliseconds is indeed possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗