Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Theoretical and experimental analysis of the modulated phase grating X-ray interferometer

X-ray grating interferometry allows for the simultaneous acquisition of attenuation, differential-phase contrast, and dark-field images, resulting from X-ray attenuation, refraction, and small-angle scattering, respectively. The modulated phase grating (MPG) interferometer is a recently developed grating interferometry system capable of generating a directly resolvable interference pattern using a relatively large period grating envelope function that is sampled at a pitch that is small enough that X-ray spatial coherence can be achieved by using a microfocus X-ray source or G0 grating. We present the theory of the MPG interferometry system for a 2-dimensional staggered grating, derived using Fourier optics, and we compare the theoretical predictions with experiments we have performed with a microfocus X-ray system at Pennington Biomedical Research Center, LSU. The theoretical and experimental fringe visibility is evaluated as a function of grating-to-detector distance. Additionally, quantitative experiments are performed with porous carbon and alumina compounds, and the mean normalized dark-field signal is compared with independent porosimetry measurements. Qualitative analysis of attenuation and dark-field images of a dried anchovy are shown.

47 OTHER INSTRUMENTATION↗

Non-Destructive Monitoring of Charge-Discharge Cycles on Lithium Ion Batteries using 7 Li Stray-Field Imaging

Magnetic resonance imaging provides a noninvasive method for in situ monitoring of electrochemical processes involved in charge/discharge cycling of batteries. Determining how the electrochemical processes become irreversible, ultimately resulting in degraded battery performance, will aid in developing new battery materials and designing better batteries. Here we introduce the use of an alternative in situ diagnostic tool to monitor the electrochemical processes. Utilizing a very large field-gradient in the fringe field of a magnet, stray-field-imaging (STRAFI) technique significantly improves the image resolution. These STRAFI images enable the real time monitoring of the electrodes at a micron level. It is demonstrated by two prototype half-cells, graphite ∥Li and LiFePO 4 ∥ Li, that the high-resolution 7 Li STRAFI profiles allow one to visualize in situ Li-ions transfer between the electrodes during charge/discharge cyclings as well as the formation and changes of irreversible microstructures of the Li components, and particularly reveal a non-uniform Li-ion distribution in the graphite.

25 ENERGY STORAGE↗

Correlating Elastic Properties and Molecular Organization of an Ionic Organic Nanostructure

Mechanical and structural properties of ionically self-assembled nanostructures of meso-tetra(4-sulfonatophenyl)porphyrin (TSPP) and meso-tetra(4-pyridyl)porphyrin (TPyP) are presented. This is the first time that elastic modulus of an ionic porphyrin nanostructure has been reported. X-ray photoelectron spectroscopy (XPS), UV-visible spectra, and elemental analysis all support a stoichiometric 1 : 1 TSPP to TPyP composition. Atomic force microscopy (AFM) revealed that the porphyrin nanostructure is composed of stacked ribbons about 20 nm tall, 70 nm wide, and several microns in length. High resolution transmission electron microscopy (HRTEM) images showed clear lattice fringes 1.5 ± 0.2 nm in width aligned along the length of the nanorod. Selected area electron diffraction (SAED) and powder X-ray diffraction patterns of TSPP:TPyP are consistent with an orthorhombic system and space group Imm2 with lattice parameters a ¼ 26.71 °A, b ¼ 20.16 °A, and c ¼ 8.61 °A. Crystallographic data is consistent with an arrangement of alternating face-to-face TSPP and TPyP molecules forming ordered columns along the length of the nanorods. The structural integrity of the solid is attributed to combined noncovalent interactions that include ionic, hydrogen bonding, and p–p interactions. The values of Young’s modulus obtained for the crystalline TSPP:TPyP nanorods averaged 6.5 ± 1.3 GPa. This modulus is comparable to those reported for covalently bonded flexible polymeric systems. The robust bonding character of the TSPP:TPyP nanostructures combined with their mechanical properties makes them excellent candidates for flexible optoelectronic devices.

36 MATERIALS SCIENCE↗

SYMBA: An end-to-end VLBI synthetic data generation pipeline

Realistic synthetic observations of theoretical source models are essential for our understanding of real observational data. In using synthetic data, one can verify the extent to which source parameters can be recovered and evaluate how various data corruption effects can be calibrated. These studies are the most important when proposing observations of new sources, in the characterization of the capabilities of new or upgraded instruments, and when verifying model-based theoretical predictions in a direct comparison with observational data. We present the SYnthetic Measurement creator for long Baseline Arrays (SYMBA), a novel synthetic data generation pipeline for Very Long Baseline Interferometry (VLBI) observations. SYMBA takes into account several realistic atmospheric, instrumental, and calibration effects. Here, we used SYMBA to create synthetic observations for the Event Horizon Telescope (EHT), a millimetre VLBI array, which has recently captured the first image of a black hole shadow. After testing SYMBA with simple source and corruption models, we study the importance of including all corruption and calibration effects, compared to the addition of thermal noise only. Using synthetic data based on two example general relativistic magnetohydrodynamics (GRMHD) model images of M 87, we performed case studies to assess the image quality that can be obtained with the current and future EHT array for different weather conditions. Our synthetic observations show that the effects of atmospheric and instrumental corruptions on the measured visibilities are significant. Despite these effects, we demonstrate how the overall structure of our GRMHD source models can be recovered robustly with the EHT2017 array after performing calibration steps, which include fringe fitting, a priori amplitude and network calibration, and self-calibration. With the planned addition of new stations to the EHT array in the coming years, images could be reconstructed with higher angular resolution and dynamic range. In our case study, these improvements allowed for a distinction between a thermal and a non-thermal GRMHD model based on salient features in reconstructed images.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanoscopy of Surface-Induced van der Waals-Zeeman Transitions

van der Waals transitions among magnetic sub-levels of a metastable rare gas atom passing near a surface immersed in a magnetic field, are described. Related transition amplitudes are calculated using both the sudden and the Landau-Zener approximations. Experimental data for Ne*({sup 3}P{sub 2}) atoms traversing a copper grating are presented. For a pair of surfaces (e.g. the opposite edges of a slit) and a sufficiently large coherence width, Fresnel's biprism interference fringes are obtained. From this interference pattern, detailed information about the transition amplitude at a sub-nanometric scale can be derived. The effect of gravity on this pattern is examined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Design of the MsAa-4 Moessbauer Spectrometer

An entirely new Moessbauer spectrometer MsAa-4 is currently being under design and construction. New features as compared to the basic features of the previous generation MsAa-3 spectrometer could be summarized as follows. Completely digital processing of the {gamma}-ray detector signal beyond the Gaussian shape filter/amplifier is to be implemented. The spectrometer is going to be able to accommodate external multiple detector heads. Up to 128 {gamma}-ray spectra in 16384 channels of 32-bit each and up to 512 Moessbauer spectra in 4096 channels of 32-bit each could be collected simultaneously, provided the proper external multiple detector head is used. The count-rate per single detector is limited to about 10{sup 5} counts per second in total. Improved precision of the reference function from 12-bit to 16-bit is to be provided. The reference function is stored in 8192 channels per a complete cycle. Addition of the random noise to the reference corner prism of the Michelson-Morley calibration interferometer is to be introduced to avoid spurious fringes due to the phase lock-up. An integrated universal temperature controller being able to use a variety of the temperature sensors is to be interconnected properly with the spectrometer. The spectrometer is now a stand-alone network device as it is equipped with the Ethernet connection to the outside world. Fast and high precision digital oscilloscope is to be incorporated to the spectrometer as the intrinsic unit. This oscilloscope could monitor signals at various crucial points of the internal spectrometer electronics. Modular design and use of the strict standards allows easy reconfiguration for other applications than Moessbauer spectroscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision high voltage divider and its application to electron beam ion traps

A high precision high voltage divider has been developed for the electron beam ion trap in Shanghai. The uncertainty caused by the temperature coefficient of resistance (TCR) and the voltage coefficient of resistance has been studied in detail and was minimized to the level of ppm (10{sup -6}) range. Once the TCR was matched between the resistors, the precision of the dividing ratio finally reached the ppm range also. We measured the delay of the divider caused by the capacitor introduced to minimize voltage ripple to be 2.35 ms. Finally we applied the divider to an experiment to measure resonant energies for some dielectronic recombination processes for highly charged xenon ions. The final energies include corrections for both space charge and fringe field effects are mostly under 0.03%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Current-voltage relation for a field ionizing He beam detector

Emerging interest in utilizing the transverse coherence properties of thermal energy atomic and molecular beams motivates the development of ionization detectors with near unit detection efficiency and adequate spatial resolution to resolve interference fringes of submicron dimension. We demonstrate that a field ionization tip coupled to a charged particle detector meets these requirements. We have systematically studied the current-voltage relationship for field ionization of helium using tungsten tips in diffuse gas and in a supersonic helium beam. For all 16 tips used in this study, the dependence of ion current on voltage for tips of fixed radius was found to differ from that for tips held at constant surface electric field. A scaling analysis is presented to explain this difference. Ion current increased on average to the 2.8 power of voltage for a tip at fixed field and approximately fifth power of voltage for fixed radius for a liquid nitrogen cooled tip in room temperature helium gas. For the helium beam, ion current increased as 2.2 power of voltage with constant surface field. The capture region of the tips was found to be up to 0.1 {mu}m{sup 2} for diffuse gas and 0.02 {mu}m{sup 2} in the beam. Velocity dependence and orientation of tip to beam were also studied.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High resolution laser induced fluorescence Doppler velocimetry utilizing saturated absorption spectroscopy

A high resolution laser induced fluorescence (LIF) system has been developed to measure the flow velocity field of neutral particles in an electron-cyclotron-resonance argon plasma. The flow velocity has been determined by the Doppler shift of the LIF spectrum, which is proportional to the velocity distribution function. Very high accuracy in velocity determination has been achieved by installing a saturated absorption spectroscopy unit into the LIF system, where the absolute value and scale of laser wavelength are determined by using the Lamb dip and the fringes of a Fabry-Perot interferometer. The minimum detectable flow velocity of a newly developed LIF system is {+-}2 m/s, and this performance remains unchanged in a long-time experiment. From the radial measurements of LIF spectra of argon metastable atoms, it is found that there exists an inward flow of neutral particles associated with neutral depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of enhanced cathode electron emission on Hall thruster operation

Interesting discharge phenomena are observed that have to do with the interaction between the magnetized Hall thruster plasma and the neutralizing cathode. The steady-state parameters of a highly ionized thruster discharge are strongly influenced by the electron supply from the cathode. The enhancement of the cathode electron emission above its self-sustained level affects the discharge current and leads to a dramatic reduction in the plasma divergence and a suppression of large amplitude, low frequency discharge current oscillations usually related to an ionization instability. These effects correlate strongly with the reduction in the voltage drop in the region with the fringing magnetic field between the thruster channel and the cathode. The measured changes in the plasma properties suggest that the electron emission affects the electron cross-field transport in the thruster discharge. These trends are generalized for Hall thrusters of various configurations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strain evolution in Si substrate due to implantation of MeV ion observed by extremely asymmetric x-ray diffraction

We studied the strain introduced in a Si(111) substrate due to MeV ion implantation using extremely asymmetric x-ray diffraction and measured the rocking curves of asymmetrical 113 diffraction for the Si substrates implanted with a 1.5 MeV Au{sup 2+} ion at fluence values of 1x10{sup 13}, 5x10{sup 13}, and 1x10{sup 14}/cm{sup 2}. The measured curves consisted of a bulk peak and accompanying subpeak with an interference fringe. The positional relationship of the bulk peak to the subpeak and the intensity variation of those peaks with respect to the wavelengths of the x rays indicated that crystal lattices near the surface were strained; the lattice spacing of surface normal (111) planes near the surface was larger than that of the bulk. Detailed strain profiles along the depth direction were successfully estimated using a curve-fitting method based on Darwin's dynamical diffraction theory. Comparing the shapes of resultant strain profiles, we found that a strain evolution rapidly occurred within a depth of approx300 nm at fluence values between 1x10{sup 13} and 5x10{sup 13}/cm{sup 2}. This indicates that formation of the complex defects progressed near the surface when the fluence value went beyond a critical value between 1x10{sup 13} and 5x10{sup 13}/cm{sup 2} and the defects brought a large strain to the substrate.

36 MATERIALS SCIENCE↗

Internal frequency conversion extreme ultraviolet interferometer using mutual coherence properties of two high-order-harmonic sources

We report on an innovative two-dimensional imaging extreme ultraviolet (XUV) interferometer operating at 32 nm based on the mutual coherence of two laser high order harmonics (HOH) sources, separately generated in gas. We give the first evidence that the two mutually coherent HOH sources can be produced in two independent spatially separated gas jets, allowing for probing centimeter-sized objects. A magnification factor of 10 leads to a micron resolution associated with a subpicosecond temporal resolution. Single shot interferograms with a fringe visibility better than 30% are routinely produced. As a test of the XUV interferometer, we measure a maximum electronic density of 3x10{sup 20} cm{sup -3} 1.1 ns after the creation of a plasma on aluminum target.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hard x-ray phase contrast imaging of black lipid membranes

We report hard x-ray phase contrast imaging of black lipid membranes, freely suspended over a micromachined aperture in an aqueous solution. Biomolecular and organic substances can thus be probed in hydrated environments by parallel beam propagation imaging, using coherent multi-kilo-electronvolt x-ray radiation. The width of the thinning film can be resolved from analysis of the intensity fringes in the Fresnel diffraction regime down to about 200 nm. The thinning process, in which solvent is expelled from the space in between two opposing monolayers, is monitored, and the domain walls between coexisting domains of swollen and thinned membrane patches are characterized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of ion beam extraction and transport from an electron cyclotron resonance ion source

We have started an experimental and theoretical program to better understand the extraction and transport of intense multiply charged ion beams from an electron cyclotron resonance ion source (ECRIS). In this paper we present the first results of this program concerning a simple, monocomponent He{sup +} beam extracted from an ECRIS. We have calculated the ion trajectories starting from the ECRIS plasma electrode up to the image plane of the analyzing magnet taking into account space-charge effects and fringe fields. The initial phase-space distribution of the He{sup +} beam at the extraction aperture has been calculated with a particle-in-cell code. To check the simulations we have measured beam profiles with a viewing screen both before and after the analyzing magnet. In addition also measurements with a pepperpot emittance meter located behind the analyzing magnet have been performed. We find good agreement between these measurements and simulations showing that (i) there is a significant compensation of the space charge and that (ii) our analyzing magnet causes a severe increase in effective beam emittance.

43 PARTICLE ACCELERATORS↗

Ramsey-type spectroscopy in the XUV spectral region

We report an experimental and theoretical investigation of Ramsey-type spectroscopy with high-order harmonic generation applied to autoionizing states of Krypton. The ionization yield, detected by an ion-mass spectrometer, shows the characteristic quantum interference pattern. The behaviour of the fringe contrast was interpreted on the basis of a simple analytic model, which reproduces the experimental data without any free parameter.

74 ATOMIC AND MOLECULAR PHYSICS↗

Differential interferometry for measurement of density fluctuations and fluctuation-induced transport (invited)

Differential interferometry employs two parallel laser beams with a small spatial offset (less than beam width) and frequency difference (1-2 MHz) using common optics and a single mixer for a heterodyne detection. The differential approach allows measurement of the electron density gradient, its fluctuations, as well as the equilibrium density distribution. This novel interferometry technique is immune to fringe skip errors and is particularly useful in harsh plasma environments. Accurate calibration of the beam spatial offset, accomplished by use of a rotating dielectric wedge, is required to enable broad application of this approach. Differential interferometry has been successfully used on the Madison Symmetric Torus reversed-field pinch plasma to directly measure fluctuation-induced transport along with equilibrium density profile evolution during pellet injection. In addition, by combining differential and conventional interferometry, both linear and nonlinear terms of the electron density fluctuation energy equation can be determined, thereby allowing quantitative investigation of the origin of the density fluctuations. The concept, calibration, and application of differential interferometry are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of thickness, refractive index, and spectral scattering of an inhomogeneous thin film with rough interfaces

The magnitude of spectral transmittance and reflectance is affected by the presence of inhomogeneity and interfacial roughness. Therefore, the methods, based on the magnitude of spectral transmittance and reflectance, are not adequate for the determination of thickness and optical constants of films with inhomogeneity and interfacial roughness. The present article proposes a method for the determination of thickness and refractive index using only the positions of the interference fringes in spectral transmittance and reflectance at two different angles of incidence. The proposed method is verified through numerical simulations, which result in <1% error for the film thickness. The complete parametrical dependence of spectral transmittance and reflectance of inhomogeneous film with rough interfaces on a substrate have been worked out for the film on transparent and opaque substrates, respectively. The spectrum envelopes have been solved simultaneously and the mathematical formulae are given for the determination of spectral scattering due to inhomogeneity and interfacial roughness for both transmittance and reflectance cases.

36 MATERIALS SCIENCE↗