Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “focal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A combined Kirkpatrick-Baez mirror and multilayer lens for sub-10 nm x-ray focusing

We have used a combined optical system of a high gain elliptic Kirkpatrick-Baez mirror system (KB) and a multilayer Laue lens (MLL) positioned in the focal plane of the KB for hard x-rays nano-focusing. The two-step focusing scheme is based on a high acceptance and high gain elliptical mirror with moderate focal length and a MLL with ultra-short focal length. Importantly, fabrication constraints, i.e. in mirror polishing and bending, as well as MLL deposition can be significantly relaxed, since (a) the mirror focus in the range of 200-500 nm is sufficient, and (b) the number of layers of the MLL can be correspondingly small. First demonstrations of this setup at the coherence beamline of the PETRA III storage ring yield a highly divergent far-field diffraction pattern, from which the autocorrelation function of the near-field intensity distribution was obtained. The results show that the approach is well suited to reach smallest spot sizes in the sub-10nm range at high flux.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and performance evaluation of an electromagnetic-type shock wave generator for lipolysis

This study aims at the design and development of electromagnetic-type intermittent shock wave generation in a liquid. The shock wave generated is focused at a focal point through an acoustic lens. This hardware device mainly consists of a full-wave bridge rectifier, 6 capacitors, a spark gap, and a flat coil. A metal disk is mounted in a liquid-filled tube and is placed in close proximity to the flat coil. Due to the repulsive force existing between the coil and disk shock waves are generated, while an eddy current is induced in the metal disk. Some components and materials associated with the device are also described. By increasing the capacitance content to enhance electric energy level, a highly focused pressure can be achieved at the focal point through an acoustic lens in order to lyse fat tissue. Focused pressures were measured at the focal point and its vicinity for different operation voltages. The designed shock wave generator with an energy intensity of 0.0016 mJ/mm{sup 2} (at 4 kV) and 2000 firings or higher energy intensities with 1000 firings is found to be able to disrupt pig fat tissue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Subwavelength light focusing with a single slit lens based on the spatial multiplexing of chirped surface gratings

A lens consisting of a subwavelength slit engraved into a metal film and surrounded by periodic surface gratings and spatial multiplexing chirped surface gratings (SMCSGs) for focusing light is proposed. The focal length of the lens can be accurately designed and tuned by controlling the periods of the local gratings of the SMCSGs. Simulation results show that a subwavelength beam spot can be produced by the lens at a distance of several times the incident wavelength from the slit and the difference between the simulated and designed focal lengths can be reduced to below 3% of the designed focal length.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonlinear effects in ultrasound fields of diagnostic-type transducers used for kidney stone propulsion: Characterization in water

Newer imaging and therapeutic ultrasound technologies require higher in situ pressure levels compared to conventional diagnostic values. One example is the recently developed use of focused ultrasonic radiation force to move kidney stones and residual fragments out of the urinary collecting system. A commercial diagnostic 2.3 MHz C5-2 array probe is used to deliver the acoustic pushing pulses. The probe comprises 128 elements equally spaced at the 55 mm long convex cylindrical surface with 38 mm radius of curvature. The efficacy of the treatment can be increased by using higher intensity at the focus to provide stronger pushing force; however, nonlinear acoustic saturation can be a limiting factor. In this work nonlinear propagation effects were analyzed for the C5-2 transducer using a combined measurement and modeling approach. Simulations were based on the 3D Westervelt equation; the boundary condition was set to match the focal geometry of the beam as measured at a low power output. Focal waveforms simulated for increased output power levels were compared with the fiber-optic hydrophone measurements and were found in good agreement. It was shown that saturation effects do limit the acoustic pressure in the focal region of the transducer. This work has application to standard diagnostic probes and imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating embedded in water

We report the nonlinear focusing of ultrasonic waves by an axisymmetric diffraction grating immersed in water. In the linear regime, the system presents high focal gain (32 dB), with a narrow beam-width and intense side lobes as it is common in focusing by Fresnel-like lenses. Activating the nonlinearity of the host medium by using high amplitude incident waves, the focusing properties of the lens dramatically change. Theoretical predictions show that the focal gain of the system extraordinary increases in the strongly nonlinear regime (Mach number of 6.1 × 10{sup −4}). Particularly, the harmonic generation is locally activated at the focal spot, and the second harmonic beam is characterized by strongly reduced side-lobes and an excellent beam profile as experiments show in agreement with theory. The results can motivate applications in medical therapy or second harmonic imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New development of laser ion source for highly charged ion beam production at Institute of Modern Physics (invited)

A laser ion source based on Nd:YAG laser has been being studied at the Institute of Modern Physics for the production of high intensity high charge state heavy ion beams in the past ten years, for possible applications both in a future accelerator complex and in heavy ion cancer therapy facilities. Based on the previous results for the production of multiple-charged ions from a wide range of heavy elements with a 3 J/8 ns Nd:YAG laser [Zhao et al., Rev. Sci. Instrum. 85, 02B910 (2014)], higher laser energy and intensity in the focal spot are necessary for the production of highly charged ions from the elements heavier than aluminum. Therefore, the laser ion source was upgraded with a new Nd:YAG laser, the maximum energy of which is 8 J and the pulse duration can be adjusted from 8 to 18 ns. Since then, the charge state distributions of ions from various elements generated by the 8 J Nd:YAG laser were investigated for different experimental conditions, such as laser energy, pulse duration, power density in the focal spot, and incidence angle. It was shown that the incidence angle is one of the most important parameters for the production of highly charged ions. The capability of producing highly charged ions from the elements lighter than silver was demonstrated with the incidence angle of 10° and laser power density of 8 × 10{sup 13} W cm{sup −2} in the focal spot, which makes a laser ion source complementary to the superconducting electron cyclotron resonance ion source for the future accelerator complex especially in terms of the ion beam production from some refractory elements. Nevertheless, great efforts with regard to the extraction of intense ion beams, modification of the ion beam pulse duration, and reliability of the ion source still need to be made for practical applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Breakdown simulations in a focused microwave beam within the simplified model

The simplified model is proposed to simulate numerically air breakdown in a focused microwave beam. The model is 1D from the mathematical point of view, but it takes into account the spatial non-uniformity of microwave field amplitude along the beam axis. The simulations are completed for different frequencies and different focal lengths of microwave beams. The results demonstrate complicated regimes of the breakdown evolution which represents a series of repeated ionization waves. These waves start at the focal point and propagate towards incident microwave radiation. The ionization wave parameters vary during propagation. At relatively low frequencies, the propagation regime of subsequent waves can also change qualitatively. Each next ionization wave is less pronounced than the previous one, and the breakdown evolution approaches the steady state with relatively small plasma density. The ionization wave parameters are sensitive to the weak source of external ionization, but the steady state is independent on such a source. As the beam focal length decreases, the stationary plasma density increases and the onset of the steady state occurs faster.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction

Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration ($z_R ≈$⁠ 5 μ m) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (⁠$z_R ≈$ 80 μ m) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New adaptive optics control strategy for petawatt-class laser chains

A new generation of ultra-high intensity femtosecond petawatt- and above-class lasers requires new approaches to wavefront corrections. New challenges for adaptive optics consist in overcoming the constraints of potentially bigger diameters, larger amplitude aberrations, faster optics, higher risk of damaging optical components and faster and easier maintenance. Here we present a new technology of a mechanical deformable mirror, which has a large stroke, high temporal stability, low hysteresis, no print-through effect, easy, safe and fast maintenance and an operating frequency up to 10 Hz. We propose the full correction of the final focal spot in the target chamber by a combination of a standard adaptive optics system, a simple focal plane camera and a phase retrieval correction process. We test the reliability of the correction system in terms of intensity variation and wavefront stability. We further verify correction robustness of the method on a large spectral bandwidth and finally perform a focal spot correction on a terawatt laser system in both low and high-power regimes. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Confinement of electrons in the focus of the dipole wave

Based on the numerical modelling of the electron dynamics in the focal region of a dipole wave, we have found the confinement time of electrons in the region of the strongest electric field in a wide (up to 200 PW) power range. By comparing confinement times of particles and the spatial structures of their escape, we have determined the regimes of ponderomotive escape and radiation-dominated escape corresponding to normal and anomalous radiative trapping, as well as the threshold powers of these regimes. It is shown that in the regimes of ponderomotive escape, the confinement time decreases with increasing power and stabilises at the level of one third of the wave period with the particles leaving the focal region predominantly across the electric field. In the radiation-dominated regime, the confinement time, on the contrary, increases with increasing power, the rate of transverse particles’ escape decreases, and the particles leave the focal region in the form of compact beams. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication of large dual-polarized multichroic TES bolometer arrays for CMB measurements with the SPT-3G camera

This paper presents the procedures used by Argonne National Laboratory to fabricate large arrays of multichroic transition-edge sensor (TES) bolometers for cosmic microwave background (CMB) measurements. These detectors will be assembled into the focal plane for the SPT-3G camera, the third generation CMB camera to be installed in the South Pole Telescope. The complete SPT-3G camera will have approximately 2690 pixels, for a total of 16,140 TES bolometric detectors. Each pixel is comprised of a broad-band sinuous antenna coupled to a Nb microstrip line. In-line filters are used to define the different band-passes before the millimeter-wavelength signal is fed to the respective Ti/Au TES bolometers. There are six TES bolometer detectors per pixel, which allow for measurements of three band-passes (95 GHz, 150 GHz and 220 GHz) and two polarizations. The steps involved in the monolithic fabrication of these detector arrays are presented here in detail. Patterns are defined using a combination of stepper and contact lithography. The misalignment between layers is kept below 200 nm. The overall fabrication involves a total of 16 processes, including reactive and magnetron sputtering, reactive ion etching, inductively coupled plasma etching and chemical etching.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution velocimetry in energetic tidal currents using a convergent-beam acoustic Doppler profiler

An array of convergent acoustic Doppler velocimeters has been developed and tested for the high resolution measurement of three-dimensional tidal flow velocities in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use diverging acoustic beams emanating from a single instrument. This is achieved using converging acoustic beams with a sample volume at the focal point of 0.03 m 3 . The array is also able to simultaneously measure three-dimensional velocity components in a profile throughout the water column, and as such is referred to herein as a converging-beam acoustic Doppler profiler (CADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational Alstom 1MW DeepGen-IV Tidal Turbine. This proof-of-concept paper outlines system configuration and comparison to measurements provided by co-installed reference instrumentation. Comparison of CADP to standard ADP velocity measurements reveals a mean difference of 8 mm/s, standard deviation of 18 mm/s, and order-of-magnitude reduction in realizable length-scale. CADP focal point measurements compared to a proximal single-beam reference show peak cross-correlation coefficient of 0.96 over 4.0 s averaging period and a 47% reduction in Doppler noise. The dual functionality of the CADP as a profiling instrument with a high resolution focal point make this configuration a unique and valuable advancement in underwater velocimetry enabling improved turbulence, resource and structural loading quantification and validation of numerical simulations. Alternative modes of operation have been implemented including noise-reducing bi-static sampling. Since waves are simultaneously measured it is expected that derivatives of this system will be a powerful tool in wave-current interaction studies.

47 OTHER INSTRUMENTATION↗

Remote detection of radioactive material using a short-pulse CO 2 laser

Detection of radioactive material at distances greater than the radiated particle range is an important goal with applications in areas such as national defense and disaster response. Here, we demonstrate avalanche-breakdown-based remote detection of a 3.6 mCi α-particle source at a standoff distance of 10 m, using 70 ps, long-wave infrared (λ = 9.2 µm) CO 2 laser pulses. This is ∼10 times longer than our previous results using a mid-IR laser. The primary detection method is direct backscatter from microplasmas generated in the laser focal volume. The backscatter signal is amplified as it propagates back through the CO 2 laser chain, enhancing sensitivity by >100 times. Here we also characterize breakdown plasmas with fluorescence imaging, and present a simple model to estimate backscattered signals as a function of the seed density profile in the laser focal volume. All of this is achieved with a relatively long-drive laser focal geometry (f/200) that is readily scalable to >100 m.

43 PARTICLE ACCELERATORS↗

Implications of asymmetric beam geometry for convergent acoustic Doppler profilers

The focus of this research is to develop a measurement instrument to characterize complex flows at spatial and temporal resolutions pertinent to understanding hydrodynamic loads in zones of fluid-structure interaction. Foundational work has demonstrated that flow velocities can be measured at a fixed focal point using a convergent array of acoustic Doppler profiling (C-ADP) instruments. As an extension of this concept, the following approach describes an application of the technology to facilitate 3D velocity measurements at a dynamically adjustable focal point location. Furthermore, the ability to dynamically control the focal point location in real-time allows the instrument to survey velocities within a three-dimensional velocity field. The resulting configuration targets a combination of measurement fidelity and control that has not been achieved by existing remote flow measurement instrumentation in the marine environment.

Harding, Samuel F.↗

Land-use legacies and present fire regimes interact to mediate herbivory by altering the neighboring plant community

Past and present human activities, such as historic agriculture and fire suppression, are widespread and can create depauperate plant communities. Although many studies show that herbivory on focal plants depends on the density of herbivores or the composition of the surrounding plant community, it is unclear whether anthropogenic changes to plant communities alter herbivory. We tested the hypothesis that human activities that alter the plant community lead to subsequent changes in herbivory. At 20 sites distributed across 80 300 hectares, we conducted a field experiment that manipulated insect herbivore access (full exclosures and pseudo-exclosures) to four focal plant species in longleaf pine woodlands with diff erent land-use histories (post-agricultural sites or non-agricultural sites) and degrees of fi re frequency (frequent and infrequent). Plant cover, particularly herbaceous cover, was lower in post-agricultural and fi re suppressed woodlands. Density of the dominant insect herbivore at our site (grasshoppers) was positively related to plant cover. Herbivore access reduced biomass of the palatable forb Solidago odora in frequently burned post-agricultural sites and in infrequently burned non-agricultural woodlands and increased mortality of another forb (Pityopsis graminifolia ), but did not aff ect two other less palatable species ( Schizachyrium scoparium and Tephrosia virginiana ). Herbivory on S. odora exhibited a hump-shaped response to plant cover, with low herbivory at low and high levels of plant cover. Herbivore density had a weak negative effect on herbivory. These findings suggest that changes in plant cover related to past and present human activities can modify damage rates on focal S. odora plants by altering grasshopper foraging behavior rather than by altering local grasshopper density. The resulting changes in herbivory may have the potential to limit natural recovery or restoration eff orts by reducing the establishment or performance of palatable plant species.

60 APPLIED LIFE SCIENCES↗

A Hyperchromatic Lens for Recording Time-Resolved Phenomena

Current methods of recording multiple-frame images at short time scales are limited by electro-optic tube physics and radiometry. A new all-optical methodology has been developed for the capture of a high number of quasi-continuous effective frames of 2-D data at very short time scales (from less than 10–12 to more than 10–8 seconds), with improvement over existing framing camera technology in terms of short recording windows and effective number of frames. The methodology combines active illumination in which wavelength is dependent upon time and spatial position to encode temporal phenomena onto wavelength; a hyperchromatic lens to map wavelength onto axial position, and a recording technology, such as holography or plenoptic imaging, to capture the resultant focal stack in both spatial (imaging) and longitudinal (temporal) axes. The novel hyperchromatic lens we designed incorporates a combination of diffractive and refractive components to maximally separate focal position as a function of wavelength, resulting in a 45 mm focal stack with nearly constant magnification for just 5 nm of illumination bandwidth. The fabricated lens assembly was qualified as meeting design requirements and images with the expected magnification at nearly the diffraction limit across the spectral range. This paper will focus on hyperchromatic lens design.

hyperchromat, time-resolved imaging, plenoptic ima↗

Machine learning control of an elliptically bent hard x-ray mirror

This article showcases the high-resolution control of an elliptically bent hard X-ray mirror optics at the Advanced Photon Source. The mirror uses a compact laminar flexure bending mechanism to achieve elliptical shapes covering a large range of focal distances. An array of capacitive sensors are used as a surface profiler for in-situ monitoring of the mirror shape. Machine learning and control techniques were used to change the mirror shape and focus the incident X-ray at predefined focal planes. The mirror surface shape error can be controlled to be within 40 nm rms with high repeatability. This technique gives the capability to focus incident X-ray beam within a range of focal distances corresponding to shape deformation range of a mirror optics. This work would be beneficial for controlling similar adaptive optics for multiple adaptive optics systems.

adaptive optics↗

Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging

Purpose: This work applies a cascaded systems model for cone-beam CT imaging performance to the design and optimization of a system for musculoskeletal extremity imaging. The model provides a quantitative guide to the selection of system geometry, source and detector components, acquisition techniques, and reconstruction parameters. Methods: The model is based on cascaded systems analysis of the 3D noise-power spectrum (NPS) and noise-equivalent quanta (NEQ) combined with factors of system geometry (magnification, focal spot size, and scatter-to-primary ratio) and anatomical background clutter. The model was extended to task-based analysis of detectability index (d') for tasks ranging in contrast and frequency content, and d' was computed as a function of system magnification, detector pixel size, focal spot size, kVp, dose, electronic noise, voxel size, and reconstruction filter to examine trade-offs and optima among such factors in multivariate analysis. The model was tested quantitatively versus the measured NPS and qualitatively in cadaver images as a function of kVp, dose, pixel size, and reconstruction filter under conditions corresponding to the proposed scanner. Results: The analysis quantified trade-offs among factors of spatial resolution, noise, and dose. System magnification (M) was a critical design parameter with strong effect on spatial resolution, dose, and x-ray scatter, and a fairly robust optimum was identified at M {approx} 1.3 for the imaging tasks considered. The results suggested kVp selection in the range of {approx}65-90 kVp, the lower end (65 kVp) maximizing subject contrast and the upper end maximizing NEQ (90 kVp). The analysis quantified fairly intuitive results--e.g., {approx}0.1-0.2 mm pixel size (and a sharp reconstruction filter) optimal for high-frequency tasks (bone detail) compared to {approx}0.4 mm pixel size (and a smooth reconstruction filter) for low-frequency (soft-tissue) tasks. This result suggests a specific protocol for 1 x 1 (full-resolution) projection data acquisition followed by full-resolution reconstruction with a sharp filter for high-frequency tasks along with 2 x 2 binning reconstruction with a smooth filter for low-frequency tasks. The analysis guided selection of specific source and detector components implemented on the proposed scanner. The analysis also quantified the potential benefits and points of diminishing return in focal spot size, reduced electronic noise, finer detector pixels, and low-dose limits of detectability. Theoretical results agreed quantitatively with the measured NPS and qualitatively with evaluation of cadaver images by a musculoskeletal radiologist. Conclusions: A fairly comprehensive model for 3D imaging performance in cone-beam CT combines factors of quantum noise, system geometry, anatomical background, and imaging task. The analysis provided a valuable, quantitative guide to design, optimization, and technique selection for a musculoskeletal extremities imaging system under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗